메뉴 건너뛰기




Volumn , Issue 14, 2008, Pages 2111-2114

The use of diethylaminosulfur trifluoride (DAST) for fluorination in a continuous-flow microreactor

Author keywords

DAST; Flow chemistry; Fluorination; Immobilized reagents; Microreactor

Indexed keywords

CALCIUM CARBONATE; DIETHYLAMINOSULFUR TRIFLUORIDE; FLUORIDE; UNCLASSIFIED DRUG;

EID: 51149088558     PISSN: 09365214     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1078026     Document Type: Article
Times cited : (78)

References (54)
  • 5
    • 0004060819 scopus 로고
    • Chemistry of Organic Fluorine Compounds II
    • American Chemical Society: Washington DC
    • (e) Lang, R. W. In Chemistry of Organic Fluorine Compounds II, Vol. 187; ACS Monograph, American Chemical Society: Washington DC, 1995, 1143.
    • (1995) ACS Monograph , vol.187 , pp. 1143
    • Lang, R.W.1
  • 14
  • 30
    • 0003428180 scopus 로고    scopus 로고
    • Ehrfield, W, Hessel, V, Löwe, H, Eds, Wiley-VCH: Weinheim
    • (x) Microreactors: New Technology for Modern Chemistry; Ehrfield, W.; Hessel, V.; Löwe, H., Eds.; Wiley-VCH: Weinheim, 2000.
    • (2000) Microreactors: New Technology for Modern Chemistry
  • 35
    • 0000420715 scopus 로고
    • John Wiley and Sons: New York
    • (c) Hudlicky, M. In Organic Reactions, Vol. 35; John Wiley and Sons: New York, 1988, 513.
    • (1988) Organic Reactions , vol.35 , pp. 513
    • Hudlicky, M.1
  • 48
    • 51149111242 scopus 로고    scopus 로고
    • Vapourtec R2+/R4 units are available from Vapourtec Ltd, Place Farm, Ingham, Suffolk, IP31 1NQ, UK. Website: http://www.vapourtec.co.uk. See also http://leyitc.ch.cam.ac.uk/equipment.html for images of the equipment.
    • Vapourtec R2+/R4 units are available from Vapourtec Ltd, Place Farm, Ingham, Suffolk, IP31 1NQ, UK. Website: http://www.vapourtec.co.uk. See also http://leyitc.ch.cam.ac.uk/equipment.html for images of the equipment.
  • 49
    • 51149105547 scopus 로고    scopus 로고
    • Commercially available Omnifit® glass chromatography columns with adjustable height-end pieces(plunger). Typically, the polymer-supported reagent is placed in an appropriately sized Omnifit® column, usually 10 mm bore by 150 mm length, or shorter and the plungers are adjusted to relevant bed heights and the polymer swelled/washed with solvent. Website: http://www.omnifit.com.
    • Commercially available Omnifit® glass chromatography columns with adjustable height-end pieces(plunger). Typically, the polymer-supported reagent is placed in an appropriately sized Omnifit® column, usually 10 mm bore by 150 mm length, or shorter and the plungers are adjusted to relevant bed heights and the polymer swelled/washed with solvent. Website: http://www.omnifit.com.
  • 50
    • 51149104425 scopus 로고    scopus 로고
    • Available from Macherey-Nagel GmbH & Co. Dueren, Germany
    • Available from Macherey-Nagel GmbH & Co. Dueren, Germany.
  • 52
    • 51149086440 scopus 로고    scopus 로고
    • Oxazoline synthesis in the total synthesis of (-)-hennoxazole A: Ley, S. V. unpublished results.
    • Oxazoline synthesis in the total synthesis of (-)-hennoxazole A: Ley, S. V. unpublished results.