메뉴 건너뛰기




Volumn 26, Issue 3, 2008, Pages 741-757

Monitoring the Critically Ill Emergency Department Patient

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; CENTRAL VENOUS PRESSURE; CRITICALLY ILL PATIENT; EMERGENCY WARD; HEART OUTPUT; HUMAN; INTENSIVE CARE; LUNG VENTILATION; PATIENT MONITORING; PRIORITY JOURNAL; PULSE OXIMETRY; REVIEW; TISSUE PERFUSION;

EID: 48949118924     PISSN: 07338627     EISSN: 07338627     Source Type: Journal    
DOI: 10.1016/j.emc.2008.06.001     Document Type: Review
Times cited : (11)

References (69)
  • 2
    • 0037865658 scopus 로고    scopus 로고
    • Respiratory monitoring tools in the intensive care unit
    • Caples S.M., and Hubmayr R.D. Respiratory monitoring tools in the intensive care unit. Curr Opin Crit Care 9 3 (2003) 230-235
    • (2003) Curr Opin Crit Care , vol.9 , Issue.3 , pp. 230-235
    • Caples, S.M.1    Hubmayr, R.D.2
  • 3
    • 0035089903 scopus 로고    scopus 로고
    • Noninvasive monitoring of oxygen and carbon dioxide
    • Soubani A.O. Noninvasive monitoring of oxygen and carbon dioxide. Am J Emerg Med 19 2 (2001) 141-146
    • (2001) Am J Emerg Med , vol.19 , Issue.2 , pp. 141-146
    • Soubani, A.O.1
  • 4
    • 0036140221 scopus 로고    scopus 로고
    • When pulse oximetry monitoring of the critically ill is not enough
    • Keogh B.F. When pulse oximetry monitoring of the critically ill is not enough. Anesth Analg 94 Suppl 1 (2002) S96-S99
    • (2002) Anesth Analg , vol.94 , Issue.SUPPL. 1
    • Keogh, B.F.1
  • 6
    • 48949114098 scopus 로고    scopus 로고
    • Bedside monitoring of pulmonary function
    • Fink M.P. (Ed), Elsevier, Philadelphia
    • Kallet R.H., and Tang J.F. Bedside monitoring of pulmonary function. In: Fink M.P. (Ed). Textbook of critical care. 5th edition (2005), Elsevier, Philadelphia 445-461
    • (2005) Textbook of critical care. 5th edition , pp. 445-461
    • Kallet, R.H.1    Tang, J.F.2
  • 7
    • 0026068835 scopus 로고
    • A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion
    • Clayton D.G., Webb R.K., Ralston A.C., et al. A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion. Anaesthesia 46 1 (1991) 3-10
    • (1991) Anaesthesia , vol.46 , Issue.1 , pp. 3-10
    • Clayton, D.G.1    Webb, R.K.2    Ralston, A.C.3
  • 8
    • 0026315091 scopus 로고
    • The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy
    • Ibanez J., Velasco J., and Raurich J.M. The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy. Intensive Care Med 17 8 (1991) 484-486
    • (1991) Intensive Care Med , vol.17 , Issue.8 , pp. 484-486
    • Ibanez, J.1    Velasco, J.2    Raurich, J.M.3
  • 9
    • 0023031885 scopus 로고
    • Effects of intravenously administered dyes on pulse oximetry readings
    • Scheller M.S., Unger R.J., and Kelner M.J. Effects of intravenously administered dyes on pulse oximetry readings. Anesthesiology 65 5 (1986) 550-552
    • (1986) Anesthesiology , vol.65 , Issue.5 , pp. 550-552
    • Scheller, M.S.1    Unger, R.J.2    Kelner, M.J.3
  • 10
    • 0028291282 scopus 로고
    • Pulse oximetry is accurate in acute anemia from hemorrhage
    • Jay G.D., Hughes L., and Renzi F.P. Pulse oximetry is accurate in acute anemia from hemorrhage. Ann Emerg Med 24 1 (1994) 32-35
    • (1994) Ann Emerg Med , vol.24 , Issue.1 , pp. 32-35
    • Jay, G.D.1    Hughes, L.2    Renzi, F.P.3
  • 11
    • 0029792696 scopus 로고    scopus 로고
    • Monitoring during mechanical ventilation
    • Jubran A., and Tobin M.J. Monitoring during mechanical ventilation. Clin Chest Med 17 3 (1996) 453-473
    • (1996) Clin Chest Med , vol.17 , Issue.3 , pp. 453-473
    • Jubran, A.1    Tobin, M.J.2
  • 12
    • 33745790755 scopus 로고    scopus 로고
    • End-tidal carbon dioxide monitoring: a VITAL sign worth watching
    • xi
    • Zwerneman K. End-tidal carbon dioxide monitoring: a VITAL sign worth watching. Crit Care Nurs Clin North Am 18 2 (2006) 217-225 xi
    • (2006) Crit Care Nurs Clin North Am , vol.18 , Issue.2 , pp. 217-225
    • Zwerneman, K.1
  • 13
    • 0033853383 scopus 로고    scopus 로고
    • Carbon dioxide kinetics and capnography during critical care
    • Anderson C.T., and Breen P.H. Carbon dioxide kinetics and capnography during critical care. Crit Care 4 4 (2000) 207-215
    • (2000) Crit Care , vol.4 , Issue.4 , pp. 207-215
    • Anderson, C.T.1    Breen, P.H.2
  • 14
    • 48949114096 scopus 로고    scopus 로고
    • Critical care monitoring in the emergency department
    • Myers C. Critical care monitoring in the emergency department. Emergency Medicine Practice 9 7 (2007)
    • (2007) Emergency Medicine Practice , vol.9 , Issue.7
    • Myers, C.1
  • 15
    • 33751021087 scopus 로고    scopus 로고
    • Practical issues of hemodynamic monitoring at the bedside
    • Polanco P.M., and Pinsky M.R. Practical issues of hemodynamic monitoring at the bedside. Surg Clin North Am 86 6 (2006) 1431-1456
    • (2006) Surg Clin North Am , vol.86 , Issue.6 , pp. 1431-1456
    • Polanco, P.M.1    Pinsky, M.R.2
  • 18
    • 33645312386 scopus 로고    scopus 로고
    • Comparison of oscillometric and intraarterial systolic and diastolic blood pressures in lean, overweight, and obese patients
    • Umana E., Ahmed W., Fraley M.A., et al. Comparison of oscillometric and intraarterial systolic and diastolic blood pressures in lean, overweight, and obese patients. Angiology 57 1 (2006) 41-45
    • (2006) Angiology , vol.57 , Issue.1 , pp. 41-45
    • Umana, E.1    Ahmed, W.2    Fraley, M.A.3
  • 19
    • 34447568391 scopus 로고    scopus 로고
    • Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
    • Araghi A., Bander J.J., and Guzman J.A. Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?. Crit Care 10 2 (2006) R64
    • (2006) Crit Care , vol.10 , Issue.2
    • Araghi, A.1    Bander, J.J.2    Guzman, J.A.3
  • 20
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • Bur A., Hirschl M.M., Herkner H., et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit Care Med 28 2 (2000) 371-376
    • (2000) Crit Care Med , vol.28 , Issue.2 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3
  • 21
    • 0038027192 scopus 로고    scopus 로고
    • Diagnosis and monitoring of hemorrhagic shock during the initial resuscitation of multiple trauma patients: a review
    • Wilson M., Davis D.P., and Coimbra R. Diagnosis and monitoring of hemorrhagic shock during the initial resuscitation of multiple trauma patients: a review. J Emerg Med 24 4 (2003) 413-422
    • (2003) J Emerg Med , vol.24 , Issue.4 , pp. 413-422
    • Wilson, M.1    Davis, D.P.2    Coimbra, R.3
  • 22
    • 0019523842 scopus 로고
    • Direct blood pressure measurement-dynamic response requirements
    • Gardner R.M. Direct blood pressure measurement-dynamic response requirements. Anesthesiology 54 3 (1981) 227-236
    • (1981) Anesthesiology , vol.54 , Issue.3 , pp. 227-236
    • Gardner, R.M.1
  • 23
    • 0024546095 scopus 로고
    • Reliability of blood pressure recordings
    • Ellestad M.H. Reliability of blood pressure recordings. Am J Cardiol 63 13 (1989) 983-985
    • (1989) Am J Cardiol , vol.63 , Issue.13 , pp. 983-985
    • Ellestad, M.H.1
  • 24
    • 0346363156 scopus 로고    scopus 로고
    • Hemodynamic monitoring in the intensive care unit
    • Pinsky M.R. Hemodynamic monitoring in the intensive care unit. Clin Chest Med 24 4 (2003) 549-560
    • (2003) Clin Chest Med , vol.24 , Issue.4 , pp. 549-560
    • Pinsky, M.R.1
  • 25
    • 0036087258 scopus 로고    scopus 로고
    • Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine
    • Scheer B., Perel A., and Pfeiffer U.J. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 6 3 (2002) 199-204
    • (2002) Crit Care , vol.6 , Issue.3 , pp. 199-204
    • Scheer, B.1    Perel, A.2    Pfeiffer, U.J.3
  • 26
    • 3843116717 scopus 로고    scopus 로고
    • Arterial cannulation: a critical review
    • Cousins T.R., and O'Donnell J.M. Arterial cannulation: a critical review. AANA J 72 4 (2004) 267-271
    • (2004) AANA J , vol.72 , Issue.4 , pp. 267-271
    • Cousins, T.R.1    O'Donnell, J.M.2
  • 27
    • 0036550528 scopus 로고    scopus 로고
    • Monitoring arterial blood pressure: what you may not know
    • 66-70 [73 passim]
    • McGhee B.H., and Bridges E.J. Monitoring arterial blood pressure: what you may not know. Crit Care Nurse 22 2 (2002) 60-64 66-70 [73 passim]
    • (2002) Crit Care Nurse , vol.22 , Issue.2 , pp. 60-64
    • McGhee, B.H.1    Bridges, E.J.2
  • 29
    • 31744438011 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • Pinsky M.R., and Payen D. Functional hemodynamic monitoring. Crit Care 9 6 (2005) 566-572
    • (2005) Crit Care , vol.9 , Issue.6 , pp. 566-572
    • Pinsky, M.R.1    Payen, D.2
  • 30
    • 0028275095 scopus 로고
    • Elevation of systemic oxygen delivery in the treatment of critically ill patients
    • Hayes M.A., Timmins A.C., Yau E.H., et al. Elevation of systemic oxygen delivery in the treatment of critically ill patients. N Engl J Med 330 24 (1994) 1717-1722
    • (1994) N Engl J Med , vol.330 , Issue.24 , pp. 1717-1722
    • Hayes, M.A.1    Timmins, A.C.2    Yau, E.H.3
  • 31
    • 34249728911 scopus 로고    scopus 로고
    • At the threshold of noninvasive functional hemodynamic monitoring
    • Pinsky M.R. At the threshold of noninvasive functional hemodynamic monitoring. Anesthesiology 106 6 (2007) 1084-1085
    • (2007) Anesthesiology , vol.106 , Issue.6 , pp. 1084-1085
    • Pinsky, M.R.1
  • 32
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • Michard F., and Teboul J.L. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121 6 (2002) 2000-2008
    • (2002) Chest , vol.121 , Issue.6 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 33
    • 0242637019 scopus 로고    scopus 로고
    • The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients
    • Perel A. The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients. Anaesthesist 52 11 (2003) 1003-1004
    • (2003) Anaesthesist , vol.52 , Issue.11 , pp. 1003-1004
    • Perel, A.1
  • 34
    • 4444225425 scopus 로고    scopus 로고
    • Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
    • Hollenberg S.M., Ahrens T.S., Annane D., et al. Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update. Crit Care Med 32 (2004) 1928-1948
    • (2004) Crit Care Med , vol.32 , pp. 1928-1948
    • Hollenberg, S.M.1    Ahrens, T.S.2    Annane, D.3
  • 35
    • 33748103692 scopus 로고    scopus 로고
    • Central venous pressure: a useful but not so simple measurement
    • Magder S. Central venous pressure: a useful but not so simple measurement. Crit Care Med 34 8 (2006) 2224-2227
    • (2006) Crit Care Med , vol.34 , Issue.8 , pp. 2224-2227
    • Magder, S.1
  • 36
    • 33646567765 scopus 로고    scopus 로고
    • Fluid challenge revisited
    • Vincent J.L., and Weil M.H. Fluid challenge revisited. Crit Care Med 34 5 (2006) 1333-1337
    • (2006) Crit Care Med , vol.34 , Issue.5 , pp. 1333-1337
    • Vincent, J.L.1    Weil, M.H.2
  • 37
    • 0037865718 scopus 로고    scopus 로고
    • Cardiovascular monitoring tools: use and misuse
    • Bellomo R., and Uchino S. Cardiovascular monitoring tools: use and misuse. Curr Opin Crit Care 9 3 (2003) 225-229
    • (2003) Curr Opin Crit Care , vol.9 , Issue.3 , pp. 225-229
    • Bellomo, R.1    Uchino, S.2
  • 38
    • 34347222567 scopus 로고    scopus 로고
    • Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006
    • Antonelli M., Levy M., Andrews P.J., et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006. Intensive Care Med 33 4 (2007) 575-590
    • (2007) Intensive Care Med , vol.33 , Issue.4 , pp. 575-590
    • Antonelli, M.1    Levy, M.2    Andrews, P.J.3
  • 39
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F., Boussat S., Chemla D., et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162 1 (2000) 134-138
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.1 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3
  • 40
    • 37549025018 scopus 로고    scopus 로고
    • Hemodynamic evaluation and monitoring in the ICU
    • Pinsky M.R. Hemodynamic evaluation and monitoring in the ICU. Chest 132 6 (2007) 2020-2029
    • (2007) Chest , vol.132 , Issue.6 , pp. 2020-2029
    • Pinsky, M.R.1
  • 41
    • 0034762654 scopus 로고    scopus 로고
    • The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP
    • Magder S., Lagonidis D., and Erice F. The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP. J Crit Care 16 3 (2001) 108-114
    • (2001) J Crit Care , vol.16 , Issue.3 , pp. 108-114
    • Magder, S.1    Lagonidis, D.2    Erice, F.3
  • 42
    • 34247334256 scopus 로고    scopus 로고
    • Bedside echocardiography in the assessment of the critically ill
    • Beaulieu Y. Bedside echocardiography in the assessment of the critically ill. Crit Care Med 35 Suppl 5 (2007) S235-S249
    • (2007) Crit Care Med , vol.35 , Issue.SUPPL. 5
    • Beaulieu, Y.1
  • 43
    • 20144377685 scopus 로고    scopus 로고
    • Year in review in intensive care medicine, 2004. II. Brain injury, hemodynamic monitoring and treatment, pulmonary embolism, gastrointestinal tract, and renal failure
    • Andrews P., Azoulay E., Antonelli M., et al. Year in review in intensive care medicine, 2004. II. Brain injury, hemodynamic monitoring and treatment, pulmonary embolism, gastrointestinal tract, and renal failure. Intensive Care Med 31 2 (2005) 177-188
    • (2005) Intensive Care Med , vol.31 , Issue.2 , pp. 177-188
    • Andrews, P.1    Azoulay, E.2    Antonelli, M.3
  • 44
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • Feissel M., Michard F., Faller J.P., et al. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 30 9 (2004) 1834-1837
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3
  • 45
    • 0029947642 scopus 로고    scopus 로고
    • Lactic acidosis during sepsis is related to increased pyruvate production, not deficits in tissue oxygen availability
    • Gore D.C., Jahoor F., Hibbert J.M., et al. Lactic acidosis during sepsis is related to increased pyruvate production, not deficits in tissue oxygen availability. Ann Surg 224 1 (1996) 97-102
    • (1996) Ann Surg , vol.224 , Issue.1 , pp. 97-102
    • Gore, D.C.1    Jahoor, F.2    Hibbert, J.M.3
  • 46
    • 0022443686 scopus 로고
    • Effect of sepsis on activity of pyruvate dehydrogenase complex in skeletal muscle and liver
    • Vary T.C., Siegel J.H., Nakatani T., et al. Effect of sepsis on activity of pyruvate dehydrogenase complex in skeletal muscle and liver. Am J Physiol 250 6 Pt 1 (1986) E634-E640
    • (1986) Am J Physiol , vol.250 , Issue.6 PART 1
    • Vary, T.C.1    Siegel, J.H.2    Nakatani, T.3
  • 47
    • 0035688766 scopus 로고    scopus 로고
    • Prolonged lactate clearance is associated with increased mortality in the surgical intensive care unit
    • McNelis J., Marini C.P., Jurkiewicz A., et al. Prolonged lactate clearance is associated with increased mortality in the surgical intensive care unit. Am J Surg 182 5 (2001) 481-485
    • (2001) Am J Surg , vol.182 , Issue.5 , pp. 481-485
    • McNelis, J.1    Marini, C.P.2    Jurkiewicz, A.3
  • 48
    • 0027453585 scopus 로고
    • Lactate clearance and survival following injury
    • [discussion: 588-9]
    • Abramson D., Scalea T.M., Hitchcock R., et al. Lactate clearance and survival following injury. J Trauma 35 4 (1993) 584-588 [discussion: 588-9]
    • (1993) J Trauma , vol.35 , Issue.4 , pp. 584-588
    • Abramson, D.1    Scalea, T.M.2    Hitchcock, R.3
  • 49
    • 0028801267 scopus 로고
    • Correlation of serial blood lactate levels to organ failure and mortality after trauma
    • Manikis P., Jankowski S., Zhang H., et al. Correlation of serial blood lactate levels to organ failure and mortality after trauma. Am J Emerg Med 13 6 (1995) 619-622
    • (1995) Am J Emerg Med , vol.13 , Issue.6 , pp. 619-622
    • Manikis, P.1    Jankowski, S.2    Zhang, H.3
  • 50
    • 0036125696 scopus 로고    scopus 로고
    • Serum lactate, not base deficit, rapidly predicts survival after major burns
    • Jeng J.C., Jablonski K., Bridgeman A., et al. Serum lactate, not base deficit, rapidly predicts survival after major burns. Burns 28 2 (2002) 161-166
    • (2002) Burns , vol.28 , Issue.2 , pp. 161-166
    • Jeng, J.C.1    Jablonski, K.2    Bridgeman, A.3
  • 51
    • 0037408227 scopus 로고    scopus 로고
    • Serum lactate and base deficit as predictors of mortality and morbidity
    • Husain F.A., Martin M.J., Mullenix P.S., et al. Serum lactate and base deficit as predictors of mortality and morbidity. Am J Surg 185 5 (2003) 485-491
    • (2003) Am J Surg , vol.185 , Issue.5 , pp. 485-491
    • Husain, F.A.1    Martin, M.J.2    Mullenix, P.S.3
  • 52
    • 33748082980 scopus 로고    scopus 로고
    • Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate
    • Middleton P., Kelly A.M., Brown J., et al. Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate. Emerg Med J 23 8 (2006) 622-624
    • (2006) Emerg Med J , vol.23 , Issue.8 , pp. 622-624
    • Middleton, P.1    Kelly, A.M.2    Brown, J.3
  • 54
    • 0032807347 scopus 로고    scopus 로고
    • Sublingual capnometry: a new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock
    • Weil M.H., Nakagawa Y., Tang W., et al. Sublingual capnometry: a new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock. Crit Care Med 27 7 (1999) 1225-1229
    • (1999) Crit Care Med , vol.27 , Issue.7 , pp. 1225-1229
    • Weil, M.H.1    Nakagawa, Y.2    Tang, W.3
  • 55
    • 0037351579 scopus 로고    scopus 로고
    • Sublingual capnometry versus traditional markers of tissue oxygenation in critically ill patients
    • Marik P.E., and Bankov A. Sublingual capnometry versus traditional markers of tissue oxygenation in critically ill patients. Crit Care Med 31 3 (2003) 818-822
    • (2003) Crit Care Med , vol.31 , Issue.3 , pp. 818-822
    • Marik, P.E.1    Bankov, A.2
  • 56
    • 0034831025 scopus 로고    scopus 로고
    • Sublingual capnography: a clinical validation study
    • Marik P.E. Sublingual capnography: a clinical validation study. Chest 120 3 (2001) 923-927
    • (2001) Chest , vol.120 , Issue.3 , pp. 923-927
    • Marik, P.E.1
  • 57
    • 26444447577 scopus 로고    scopus 로고
    • Noninvasive monitoring of peripheral perfusion
    • Lima A., and Bakker J. Noninvasive monitoring of peripheral perfusion. Intensive Care Med 31 10 (2005) 1316-1326
    • (2005) Intensive Care Med , vol.31 , Issue.10 , pp. 1316-1326
    • Lima, A.1    Bakker, J.2
  • 58
    • 0033623843 scopus 로고    scopus 로고
    • Transcutaneous oxygen and CO2 as early warning of tissue hypoxia and hemodynamic shock in critically ill emergency patients
    • Tatevossian R.G., Wo C.C., Velmahos G.C., et al. Transcutaneous oxygen and CO2 as early warning of tissue hypoxia and hemodynamic shock in critically ill emergency patients. Crit Care Med 28 7 (2000) 2248-2253
    • (2000) Crit Care Med , vol.28 , Issue.7 , pp. 2248-2253
    • Tatevossian, R.G.1    Wo, C.C.2    Velmahos, G.C.3
  • 59
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
    • Harvey S., Harrison D.A., Singer M., et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 366 9484 (2005) 472-477
    • (2005) Lancet , vol.366 , Issue.9484 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 60
    • 26044460566 scopus 로고    scopus 로고
    • Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial
    • Binanay C., Califf R.M., Hasselblad V., et al. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA 294 13 (2005) 1625-1633
    • (2005) JAMA , vol.294 , Issue.13 , pp. 1625-1633
    • Binanay, C.1    Califf, R.M.2    Hasselblad, V.3
  • 61
    • 0035908639 scopus 로고    scopus 로고
    • Right heart catheterization and cardiac complications in patients undergoing noncardiac surgery: an observational study
    • Polanczyk C.A., Rohde L.E., Goldman L., et al. Right heart catheterization and cardiac complications in patients undergoing noncardiac surgery: an observational study. JAMA 286 3 (2001) 309-314
    • (2001) JAMA , vol.286 , Issue.3 , pp. 309-314
    • Polanczyk, C.A.1    Rohde, L.E.2    Goldman, L.3
  • 62
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham J.D., Hull R.D., Brant R.F., et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 348 1 (2003) 5-14
    • (2003) N Engl J Med , vol.348 , Issue.1 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 63
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial
    • Richard C., Warszawski J., Anguel N., et al. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290 20 (2003) 2713-2720
    • (2003) JAMA , vol.290 , Issue.20 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3
  • 64
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors Jr. A.F., Speroff T., Dawson N.V., et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276 11 (1996) 889-897
    • (1996) JAMA , vol.276 , Issue.11 , pp. 889-897
    • Connors Jr., A.F.1    Speroff, T.2    Dawson, N.V.3
  • 65
    • 26044478155 scopus 로고    scopus 로고
    • Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials
    • Shah M.R., Hasselblad V., Stevenson L.W., et al. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 294 13 (2005) 1664-1670
    • (2005) JAMA , vol.294 , Issue.13 , pp. 1664-1670
    • Shah, M.R.1    Hasselblad, V.2    Stevenson, L.W.3
  • 66
    • 0036800276 scopus 로고    scopus 로고
    • Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology
    • Chaney J.C., and Derdak S. Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med 30 10 (2002) 2338-2345
    • (2002) Crit Care Med , vol.30 , Issue.10 , pp. 2338-2345
    • Chaney, J.C.1    Derdak, S.2
  • 67
    • 11144335979 scopus 로고    scopus 로고
    • The validity of trans-esophageal doppler ultrasonography as a measure of cardiac output in critically ill adults
    • Dark P.M., and Singer M. The validity of trans-esophageal doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med 30 11 (2004) 2060-2066
    • (2004) Intensive Care Med , vol.30 , Issue.11 , pp. 2060-2066
    • Dark, P.M.1    Singer, M.2
  • 68
    • 0036273775 scopus 로고    scopus 로고
    • Use of echocardiography for hemodynamic monitoring
    • Brown J.M. Use of echocardiography for hemodynamic monitoring. Crit Care Med 30 6 (2002) 1361-1364
    • (2002) Crit Care Med , vol.30 , Issue.6 , pp. 1361-1364
    • Brown, J.M.1
  • 69
    • 33845317902 scopus 로고    scopus 로고
    • Transoesophageal echocardiography in critical care
    • Huttemann E. Transoesophageal echocardiography in critical care. Minerva Anestesiol 72 11 (2006) 891-913
    • (2006) Minerva Anestesiol , vol.72 , Issue.11 , pp. 891-913
    • Huttemann, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.