메뉴 건너뛰기




Volumn 15, Issue 3, 2004, Pages 207-219

Fast patient workup in acute stroke using parallel imaging

Author keywords

GRAPPA; Ischemia; Parallel imaging; SENSE; SMASH; Stroke

Indexed keywords

ARTICLE; BLEEDING; COMPUTER ASSISTED TOMOGRAPHY; FIBRINOLYTIC THERAPY; GENERALIZED AUTOCALIBRATING PARTIALLY PARALLEL ACQUISITION; HUMAN; IMAGE QUALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICAL RESOLUTION; PARALLEL IMAGING; PRIORITY JOURNAL; SENSITIVITY ENCODING; SIMULTANEOUS ACQUISITION OF SPATIAL HARMONICS; SPATIAL RESOLUTION; STROKE; TECHNIQUE; TEMPORAL RESOLUTION;

EID: 4444245958     PISSN: 08993459     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rmr.0000132790.61835.f7     Document Type: Article
Times cited : (4)

References (71)
  • 2
    • 0032952809 scopus 로고    scopus 로고
    • Stroke incidence and survival among middle-aged adults: 9-Year follow-up of the Atherosclerosis Risk in Communities (ARIC) cohort
    • Rosamond WD, Folsom AR, Chambless LE, et al. Stroke incidence and survival among middle-aged adults: 9-year follow-up of the Atherosclerosis Risk in Communities (ARIC) cohort. Stroke. 1999;30:736-743.
    • (1999) Stroke , vol.30 , pp. 736-743
    • Rosamond, W.D.1    Folsom, A.R.2    Chambless, L.E.3
  • 3
    • 0032707568 scopus 로고    scopus 로고
    • Incidence rates of first-ever ischemic stroke subtypes among blacks: A population-based study
    • Woo D, Gebel J, Miller R, et al. Incidence rates of first-ever ischemic stroke subtypes among blacks: a population-based study. Stroke. 1999;30:2517-2522.
    • (1999) Stroke , vol.30 , pp. 2517-2522
    • Woo, D.1    Gebel, J.2    Miller, R.3
  • 4
    • 4444263883 scopus 로고    scopus 로고
    • MMWR. 2001;50:7.
    • (2001) MMWR , vol.50 , pp. 7
  • 6
    • 0034855790 scopus 로고    scopus 로고
    • Thrombolytic therapy for ischemic stroke: A review. 1. Intravenous thrombolysis
    • Schellinger PD, Fiebach JB, Mohr A, et al. Thrombolytic therapy for ischemic stroke: a review. 1. Intravenous thrombolysis. Crit Care Med. 2001;29:1812-1818.
    • (2001) Crit Care Med , vol.29 , pp. 1812-1818
    • Schellinger, P.D.1    Fiebach, J.B.2    Mohr, A.3
  • 7
    • 0034840614 scopus 로고    scopus 로고
    • Thrombolytic therapy for ischemic stroke: A review. I1. Intra-arterial thrombolysis, vertebrobasilar stroke, phase IV trials, and stroke imaging
    • Schellinger PD, Fiebach JB, Mohr A, et al. Thrombolytic therapy for ischemic stroke: a review. I1. Intra-arterial thrombolysis, vertebrobasilar stroke, phase IV trials, and stroke imaging. Crit Care Med. 2001;29:1819-1825.
    • (2001) Crit Care Med , vol.29 , pp. 1819-1825
    • Schellinger, P.D.1    Fiebach, J.B.2    Mohr, A.3
  • 8
    • 0032744573 scopus 로고    scopus 로고
    • Thrombolysis in acute ischemic stroke: Controlled trials and clinical experience
    • Hacke W, Brott T, Caplan L, et al. Thrombolysis in acute ischemic stroke: controlled trials and clinical experience. Neurology. 1999;53(suppl):3-14.
    • (1999) Neurology , vol.53 , Issue.SUPPL. , pp. 3-14
    • Hacke, W.1    Brott, T.2    Caplan, L.3
  • 9
    • 0034480640 scopus 로고    scopus 로고
    • European Stroke Initiative (EUSI) recommendations for stroke management: The European Stroke Initiative Writing Committee
    • Hacke W, Kaste M, Skyhoj Olsen T, et al. European Stroke Initiative (EUSI) recommendations for stroke management: the European Stroke Initiative Writing Committee. Eur J Neurol. 2000;7:607-623.
    • (2000) Eur J Neurol , vol.7 , pp. 607-623
    • Hacke, W.1    Kaste, M.2    Skyhoj Olsen, T.3
  • 10
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke
    • National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. Tissue plasminogen activator for acute ischemic stroke. N Engl J Med. 1995;333:1581-1587.
    • (1995) N Engl J Med , vol.333 , pp. 1581-1587
  • 11
    • 0030045726 scopus 로고    scopus 로고
    • The effect of multiple neuroimaging studies on classification, treatment, and outcome of acute ischemic stroke
    • Salerno SM, Landry FJ, Schick JD, et al. The effect of multiple neuroimaging studies on classification, treatment, and outcome of acute ischemic stroke. Ann Intern Med. 1996;124:21-26.
    • (1996) Ann Intern Med , vol.124 , pp. 21-26
    • Salerno, S.M.1    Landry, F.J.2    Schick, J.D.3
  • 12
    • 0025767305 scopus 로고
    • Diagnosis of acute cerebral infarction: Comparison of CT and MRI
    • Bryan RN, Levy LM, Whitlow WD, et al. Diagnosis of acute cerebral infarction: comparison of CT and MRI. AJNR Am J Neuroradiol. 1991;12:611-620.
    • (1991) AJNR Am J Neuroradiol , vol.12 , pp. 611-620
    • Bryan, R.N.1    Levy, L.M.2    Whitlow, W.D.3
  • 13
    • 0020064292 scopus 로고
    • CT findings within 24 hours after cerebral infarction: CT findings within 24 hours after cerebral infarction
    • Wall S, Brant-Zawadzki M, Jeffrey R, et al. CT findings within 24 hours after cerebral infarction: CT findings within 24 hours after cerebral infarction. AJR Am J Roentgenol. 1982;138:307-311.
    • (1982) AJR Am J Roentgenol , vol.138 , pp. 307-311
    • Wall, S.1    Brant-Zawadzki, M.2    Jeffrey, R.3
  • 14
    • 0026609565 scopus 로고
    • The impact of magnetic resonance imaging on the management of acute ischemic stroke
    • Shuaib A, Lee D, Pelz D, et al. The impact of magnetic resonance imaging on the management of acute ischemic stroke. Neurology. 1992;42:816-818.
    • (1992) Neurology , vol.42 , pp. 816-818
    • Shuaib, A.1    Lee, D.2    Pelz, D.3
  • 15
    • 0028940416 scopus 로고
    • Magnetic resonance versus computed tomographic imaging in acute stroke
    • Mohr JP, Biller J, Hilal SK, et al. Magnetic resonance versus computed tomographic imaging in acute stroke. Stroke. 1995;26:807-812.
    • (1995) Stroke , vol.26 , pp. 807-812
    • Mohr, J.P.1    Biller, J.2    Hilal, S.K.3
  • 16
    • 0030042325 scopus 로고    scopus 로고
    • Prognostic value of the hyperdense middle cerebral artery sign and stroke scale score before ultra-early thrombolytic therapy
    • Tomsick T, Brott T, Barsan W, et al. Prognostic value of the hyperdense middle cerebral artery sign and stroke scale score before ultra-early thrombolytic therapy. AJNR Am JNeuroradiol. 1996;17:79-85.
    • (1996) AJNR Am JNeuroradiol , vol.17 , pp. 79-85
    • Tomsick, T.1    Brott, T.2    Barsan, W.3
  • 17
    • 0030030576 scopus 로고    scopus 로고
    • Detectability of cerebral hemisphere ischaemic infarcts by CT within 6 h of stroke
    • von Kummer R, Nolte PN, Schnittger H, et al. Detectability of cerebral hemisphere ischaemic infarcts by CT within 6 h of stroke. Neuroradiology. 1996;38:31-33.
    • (1996) Neuroradiology , vol.38 , pp. 31-33
    • Von Kummer, R.1    Nolte, P.N.2    Schnittger, H.3
  • 19
    • 0031683610 scopus 로고    scopus 로고
    • Effect of training in reading CT scans on patient selection for ECASS 11
    • von Kummer R. Effect of training in reading CT scans on patient selection for ECASS 11. Neurology. 1998;51(suppl):50-52.
    • (1998) Neurology , vol.51 , Issue.SUPPL. , pp. 50-52
    • Von Kummer, R.1
  • 20
    • 0032557132 scopus 로고    scopus 로고
    • Cranial computed tomography interpretation in acute stroke: Physician accuracy in determining eligibility for thrombolytic therapy
    • Schriger DL, Kalafut M, Starkman S, et al. Cranial computed tomography interpretation in acute stroke: physician accuracy in determining eligibility for thrombolytic therapy. JAMA. 1998;279:1293-1297.
    • (1998) JAMA , vol.279 , pp. 1293-1297
    • Schriger, D.L.1    Kalafut, M.2    Starkman, S.3
  • 21
    • 0037380249 scopus 로고    scopus 로고
    • Reversal of perfusion and diffusion abnormalities after intravenous thrombolysis for a lacunar infarction
    • Chalela JA, Ezzeddine M, Latour L, et al. Reversal of perfusion and diffusion abnormalities after intravenous thrombolysis for a lacunar infarction. J Neuroimaging. 2003;13:152-154.
    • (2003) J Neuroimaging , vol.13 , pp. 152-154
    • Chalela, J.A.1    Ezzeddine, M.2    Latour, L.3
  • 22
    • 1542349034 scopus 로고    scopus 로고
    • Early magnetic resonance imaging findings in patients receiving tissue plasminogen activator predict outcome: Insights into the pathophysiology of acute stroke in the thrombolysis era
    • Chalela JA, Kang D, Luby M, et al. Early magnetic resonance imaging findings in patients receiving tissue plasminogen activator predict outcome: insights into the pathophysiology of acute stroke in the thrombolysis era. Ann Neurol. 2004;55:105-112.
    • (2004) Ann Neurol , vol.55 , pp. 105-112
    • Chalela, J.A.1    Kang, D.2    Luby, M.3
  • 23
    • 0030049425 scopus 로고    scopus 로고
    • Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: A preliminary analysis
    • Warach S, Dashe JF, Edelman RR. Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: a preliminary analysis. J Cereb Blood Flow Metab. 1996;16:53-59.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 53-59
    • Warach, S.1    Dashe, J.F.2    Edelman, R.R.3
  • 24
    • 0029050323 scopus 로고
    • Intravenous thrombolysis with recombinant tissue plasminogen activator for acute hemispheric stroke: The European Cooperative Acute Stroke Study (ECASS)
    • Hacke W, Kaste M, Fieschi C, et al. Intravenous thrombolysis with recombinant tissue plasminogen activator for acute hemispheric stroke: the European Cooperative Acute Stroke Study (ECASS). JAMA. 1995;274:1017-1025.
    • (1995) JAMA , vol.274 , pp. 1017-1025
    • Hacke, W.1    Kaste, M.2    Fieschi, C.3
  • 25
    • 0032541845 scopus 로고    scopus 로고
    • Randomised double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischaemic stroke (ECASS II): Second European-Australasian Acute Stroke Study Investigators
    • Hacke W, Kaste M, Fieschi C, et al. Randomised double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischaemic stroke (ECASS II): Second European-Australasian Acute Stroke Study Investigators. Lancet. 1998;352:1245-1251.
    • (1998) Lancet , vol.352 , pp. 1245-1251
    • Hacke, W.1    Kaste, M.2    Fieschi, C.3
  • 26
    • 0029940733 scopus 로고    scopus 로고
    • Hyperacute stroke: Evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MRI
    • Sorensen AG, Buonanno FS, Gonzalez RG, et al. Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MRI. Radiology. 1996;199:391-401.
    • (1996) Radiology , vol.199 , pp. 391-401
    • Sorensen, A.G.1    Buonanno, F.S.2    Gonzalez, R.G.3
  • 27
    • 0031924087 scopus 로고    scopus 로고
    • Correlation of perfusion- and diffusion-weighted MRI with NIHSS score in acute (6.5 hour) ischemic stroke
    • Tong DC, Yenari MA, Albers GW, et al. Correlation of perfusion- and diffusion-weighted MRI with NIHSS score in acute (6.5 hour) ischemic stroke. Neurology. 1998;50:864-870.
    • (1998) Neurology , vol.50 , pp. 864-870
    • Tong, D.C.1    Yenari, M.A.2    Albers, G.W.3
  • 28
    • 0031752417 scopus 로고    scopus 로고
    • Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI
    • Barber PA, Darby DG, Desmond PM, et al. Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI. Neurology. 1998;51:418-426.
    • (1998) Neurology , vol.51 , pp. 418-426
    • Barber, P.A.1    Darby, D.G.2    Desmond, P.M.3
  • 29
    • 0032952199 scopus 로고    scopus 로고
    • A standardized MRI stroke protocol: Comparison with CT in hyperacute intracerebral hemorrhage
    • Schellinger PD, Jansen O, Fiebach JB, et al. A standardized MRI stroke protocol: comparison with CT in hyperacute intracerebral hemorrhage. Stroke. 1999;30:765-768.
    • (1999) Stroke , vol.30 , pp. 765-768
    • Schellinger, P.D.1    Jansen, O.2    Fiebach, J.B.3
  • 30
    • 0034050684 scopus 로고    scopus 로고
    • Diffusion-weighted MRI as an evolving standard of care in acute stroke
    • Hacke W, Warach S. Diffusion-weighted MRI as an evolving standard of care in acute stroke. Neurology. 2000;54:1548-1549.
    • (2000) Neurology , vol.54 , pp. 1548-1549
    • Hacke, W.1    Warach, S.2
  • 31
    • 0036130711 scopus 로고    scopus 로고
    • Detection of hyperacute subarachnoid hemorrhage of the brain by using magnetic resonance imaging
    • Wiesmann M, Mayer TE, Yousry I, et al. Detection of hyperacute subarachnoid hemorrhage of the brain by using magnetic resonance imaging. J Neurosurg. 2002;96:684-689.
    • (2002) J Neurosurg , vol.96 , pp. 684-689
    • Wiesmann, M.1    Mayer, T.E.2    Yousry, I.3
  • 32
    • 1342346881 scopus 로고    scopus 로고
    • MR1 in acute subarachnoid haemorrhage: Findings with a standardised stroke protocol
    • Fiebach JB, Schellinger PD, Geletneky K, et al. MR1 in acute subarachnoid haemorrhage: findings with a standardised stroke protocol. Neuroradiology. 2004;46:44-48.
    • (2004) Neuroradiology , vol.46 , pp. 44-48
    • Fiebach, J.B.1    Schellinger, P.D.2    Geletneky, K.3
  • 33
    • 0030476369 scopus 로고    scopus 로고
    • Detection of hyperacute primary intraparenchymal hemorrhage by magnetic resonance imaging
    • Patel MR, Edelman RR, Warach S. Detection of hyperacute primary intraparenchymal hemorrhage by magnetic resonance imaging. Stroke. 1996;27:2321-2324.
    • (1996) Stroke , vol.27 , pp. 2321-2324
    • Patel, M.R.1    Edelman, R.R.2    Warach, S.3
  • 34
    • 0032472015 scopus 로고    scopus 로고
    • Clinical experience with diffusion-weighted MR in patients with acute stroke
    • Lovblad KO, Laubach HJ, Baird AE, et al. Clinical experience with diffusion-weighted MR in patients with acute stroke. AJNR Am J Neuroradiol. 1998;19:1061-1066.
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 1061-1066
    • Lovblad, K.O.1    Laubach, H.J.2    Baird, A.E.3
  • 36
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med. 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 37
    • 0035075155 scopus 로고    scopus 로고
    • Predicting tissue outcome in acute human cerebral ischemia using combined diffusion- and perfusion-weighted MRI
    • Wu O, Koroshetz WJ, Ostergaard L, et al. Predicting tissue outcome in acute human cerebral ischemia using combined diffusion- and perfusion-weighted MRI. Stroke. 2001;32:933-942.
    • (2001) Stroke , vol.32 , pp. 933-942
    • Wu, O.1    Koroshetz, W.J.2    Ostergaard, L.3
  • 39
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med. 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 40
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 41
    • 0032997647 scopus 로고    scopus 로고
    • Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH)
    • Griswold MA, Jakob PM, Chen Q, et al. Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med. 1999;41:1236-1245.
    • (1999) Magn Reson Med , vol.41 , pp. 1236-1245
    • Griswold, M.A.1    Jakob, P.M.2    Chen, Q.3
  • 42
    • 0034850918 scopus 로고    scopus 로고
    • Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE)
    • Bammer R, Keeling SL, Augustin M, et al. Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med. 2001;46:548-554.
    • (2001) Magn Reson Med , vol.46 , pp. 548-554
    • Bammer, R.1    Keeling, S.L.2    Augustin, M.3
  • 43
    • 0942297923 scopus 로고    scopus 로고
    • Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0 T
    • Willinek WA, Gieseke J, von Falkenhausen M, et al. Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0 T. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2004;176:21-26.
    • (2004) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.176 , pp. 21-26
    • Willinek, W.A.1    Gieseke, J.2    Von Falkenhausen, M.3
  • 44
    • 0036761389 scopus 로고    scopus 로고
    • Two-dimensional magnetic resonance digital subtraction angiography using array spatial sensitivity encoding techniques in the assessment of intracranial hemodynamics
    • Mori H, Aoki S, Masumoto T, et al. Two-dimensional magnetic resonance digital subtraction angiography using array spatial sensitivity encoding techniques in the assessment of intracranial hemodynamics. Radiat Med. 2002;20:223-229.
    • (2002) Radiat Med , vol.20 , pp. 223-229
    • Mori, H.1    Aoki, S.2    Masumoto, T.3
  • 45
    • 0036150228 scopus 로고    scopus 로고
    • Two-dimensional SENSE for faster three-dimensional MRI
    • Weiger M, Pruessmann KP, Boesiger P. Two-dimensional SENSE for faster three-dimensional MRI. MAGMA. 2002;14:10-19.
    • (2002) MAGMA , vol.14 , pp. 10-19
    • Weiger, M.1    Pruessmann, K.P.2    Boesiger, P.3
  • 46
    • 0034080073 scopus 로고    scopus 로고
    • Simultaneous quantitative cerebral perfusion and Gd-DTPA extravasation measurement with dual-echo dynamic susceptibility contrast MRI
    • Vonken EP, van Osch MJ, Bakker CJ, et al. Simultaneous quantitative cerebral perfusion and Gd-DTPA extravasation measurement with dual-echo dynamic susceptibility contrast MRI. Magn Reson Med. 2000;43:820-827.
    • (2000) Magn Reson Med , vol.43 , pp. 820-827
    • Vonken, E.P.1    Van Osch, M.J.2    Bakker, C.J.3
  • 47
    • 0034821090 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE)
    • Golay X, Brown SJ, Itoh R, et al. Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE). AJNR Am J Neuroradiol. 2001;22:1615-1619.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1615-1619
    • Golay, X.1    Brown, S.J.2    Itoh, R.3
  • 48
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: I. Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: I. Mathematical approach and statistical analysis. Magn Reson Med. 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3
  • 49
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: II. Experimental comparison and preliminary results
    • Ostergaard L, Sorensen AG, Kwong KK, et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: II. Experimental comparison and preliminary results. Magn Reson Med. 1996;36:726-736.
    • (1996) Magn Reson Med , vol.36 , pp. 726-736
    • Ostergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3
  • 50
    • 0038640489 scopus 로고    scopus 로고
    • Atherosclerotic disease distribution in carotid and vertebrobasilar arteries: Clinical experience in 100 patients undergoing fluoro-triggered three-dimensional Gd-MRA
    • Ersoy H, Watts R, Sanelli P, et al. Atherosclerotic disease distribution in carotid and vertebrobasilar arteries: clinical experience in 100 patients undergoing fluoro-triggered three-dimensional Gd-MRA. J Magn Reson Imaging. 2003;17:545-558.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 545-558
    • Ersoy, H.1    Watts, R.2    Sanelli, P.3
  • 51
    • 0036278068 scopus 로고    scopus 로고
    • High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography
    • Wutke R, Lang W, Fellner C, et al. High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography. Stroke. 2002;33:1522-1529.
    • (2002) Stroke , vol.33 , pp. 1522-1529
    • Wutke, R.1    Lang, W.2    Fellner, C.3
  • 52
    • 0034088266 scopus 로고    scopus 로고
    • Physiologic variations in dural venous sinus flow on phase-contrast MRI
    • Mehta NR, Jones L, Kraut MA, et al. Physiologic variations in dural venous sinus flow on phase-contrast MRI. AJR Am J Roentgenol. 2000;175:221-225.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 221-225
    • Mehta, N.R.1    Jones, L.2    Kraut, M.A.3
  • 53
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M, Chan FP, Alley MT, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging. 2003;17:499-506.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3
  • 54
    • 0242322611 scopus 로고    scopus 로고
    • Accuracy and reproducibility in phase contrast imaging using SENSE
    • Thunberg P, Karlsson M, Wigstrom L. Accuracy and reproducibility in phase contrast imaging using SENSE. Magn Reson Med. 2003;50:1061-1068.
    • (2003) Magn Reson Med , vol.50 , pp. 1061-1068
    • Thunberg, P.1    Karlsson, M.2    Wigstrom, L.3
  • 55
    • 0025298010 scopus 로고
    • Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • Farzaneh F, Riederer SJ, Pelc NJ. Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn Reson Med. 1990;14:123-139.
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 56
    • 0029866438 scopus 로고    scopus 로고
    • Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    • Butts K, de Crespigny A, Pauly JM, et al. Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes. Magn Reson Med. 1996;35:763-770.
    • (1996) Magn Reson Med , vol.35 , pp. 763-770
    • Butts, K.1    De Crespigny, A.2    Pauly, J.M.3
  • 57
    • 0028145655 scopus 로고
    • Phase errors in multi-shot echo planar imaging
    • Feinberg DA, Oshio K. Phase errors in multi-shot echo planar imaging. Magn Reson Med. 1994;32:535-539.
    • (1994) Magn Reson Med , vol.32 , pp. 535-539
    • Feinberg, D.A.1    Oshio, K.2
  • 58
    • 0030705198 scopus 로고    scopus 로고
    • Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke
    • Butts K, Pauly J, de Crespigny A, et al. Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke. Magn Reson Med. 1997;38:741-749.
    • (1997) Magn Reson Med , vol.38 , pp. 741-749
    • Butts, K.1    Pauly, J.2    De Crespigny, A.3
  • 59
    • 0028030441 scopus 로고
    • Analysis and correction of motion artifacts in diffusion weighted imaging
    • Anderson AW, Gore JC. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med. 1994;32:379-387.
    • (1994) Magn Reson Med , vol.32 , pp. 379-387
    • Anderson, A.W.1    Gore, J.C.2
  • 60
    • 0033922197 scopus 로고    scopus 로고
    • Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging
    • Atkinson D, Porter DA, Hill DL, et al. Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging. Magn Reson Med. 2000;44:101-109.
    • (2000) Magn Reson Med , vol.44 , pp. 101-109
    • Atkinson, D.1    Porter, D.A.2    Hill, D.L.3
  • 61
    • 0033045518 scopus 로고    scopus 로고
    • Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    • Bammer R, Stollberger R, Augustin M, et al. Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system. Radiology. 1999;211:799-806.
    • (1999) Radiology , vol.211 , pp. 799-806
    • Bammer, R.1    Stollberger, R.2    Augustin, M.3
  • 62
    • 4444244441 scopus 로고    scopus 로고
    • Susceptibility contrast perfusion imaging using sensitivity encoding
    • Honolulu, HI
    • Reishofer G, Ropele S, Fazekas F, et al. Susceptibility contrast perfusion imaging using sensitivity encoding. 10th Annual Meeting ISMRM, Honolulu, HI. 2002.
    • (2002) 10th Annual Meeting ISMRM
    • Reishofer, G.1    Ropele, S.2    Fazekas, F.3
  • 63
    • 0034491759 scopus 로고    scopus 로고
    • Analysis of input functions from different arterial branches with gamma variate functions and cluster analysis for quantitative blood volume measurements
    • Rausch M, Scheffler K, Rudin M, et al. Analysis of input functions from different arterial branches with gamma variate functions and cluster analysis for quantitative blood volume measurements. Magn Reson Imaging. 2000;18:1235-1243.
    • (2000) Magn Reson Imaging , vol.18 , pp. 1235-1243
    • Rausch, M.1    Scheffler, K.2    Rudin, M.3
  • 64
    • 0031932352 scopus 로고    scopus 로고
    • Self-navigated spiral fMRI: Interleaved versus single-shot
    • Glover GH, Lai S. Self-navigated spiral fMRI: interleaved versus single-shot. Magn Reson Med. 1998;39:361-368.
    • (1998) Magn Reson Med , vol.39 , pp. 361-368
    • Glover, G.H.1    Lai, S.2
  • 65
    • 0036135369 scopus 로고    scopus 로고
    • Multishot diffusion-weighted FSE using PROPELLER MRI
    • Pipe JG, Farthing VG, Forbes KP. Multishot diffusion-weighted FSE using PROPELLER MRI. Magn Reson Med. 2002;47:42-52.
    • (2002) Magn Reson Med , vol.47 , pp. 42-52
    • Pipe, J.G.1    Farthing, V.G.2    Forbes, K.P.3
  • 66
    • 0042092052 scopus 로고    scopus 로고
    • Nonlinear phase correction for navigated diffusion imaging
    • Miller KL, Pauly JM. Nonlinear phase correction for navigated diffusion imaging. Magn Reson Med. 2003;50:343-353.
    • (2003) Magn Reson Med , vol.50 , pp. 343-353
    • Miller, K.L.1    Pauly, J.M.2
  • 67
  • 68
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, et al. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med. 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3
  • 69
    • 0036290659 scopus 로고    scopus 로고
    • Diffusion tensor imaging using single-shot SENSE-EPI
    • Bammer R, Auer M, Keeling SL, et al. Diffusion tensor imaging using single-shot SENSE-EPI. Magn Reson Med. 2002;48:128-136.
    • (2002) Magn Reson Med , vol.48 , pp. 128-136
    • Bammer, R.1    Auer, M.2    Keeling, S.L.3
  • 70
    • 0032814969 scopus 로고    scopus 로고
    • Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI
    • Vonken EJ, van Osch MJ, Bakker CJ, et al. Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI. J Magn Reson Imaging. 1999;10:109-117.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 109-117
    • Vonken, E.J.1    Van Osch, M.J.2    Bakker, C.J.3
  • 71
    • 14744286793 scopus 로고    scopus 로고
    • The use of Parallel Imaging with PROPELLER DWI
    • Toronto, Canada
    • Pipe J. The use of Parallel Imaging with PROPELLER DWI. 11th Annual Meeting ISMRM, Toronto, Canada. 2002:66.
    • (2002) 11th Annual Meeting ISMRM , pp. 66
    • Pipe, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.