메뉴 건너뛰기




Volumn 36, Issue 5, 1996, Pages 715-725

High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis

Author keywords

cerebral blood flow (CBF); dynamic magnetic resonance imaging (MRI); nonparametric deconvolution; susceptibility contrast

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; BLOOD; ESTIMATION; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; PIXELS; SINGULAR VALUE DECOMPOSITION; TRACERS;

EID: 0029907308     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910360510     Document Type: Article
Times cited : (1351)

References (33)
  • 1
    • 84944487954 scopus 로고
    • Researches un the circulation time in organs and on the influences which affect it. Parts I-III
    • G. N. Stewart, Researches un the circulation time in organs and on the influences which affect it. Parts I-III. J. Physiol. (London) 15, 1 (1894).
    • (1894) J. Physiol. (London) , vol.15 , pp. 1
    • Stewart, G.N.1
  • 2
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • P. Meier, K. L. Zierler, On the theory of the indicator-dilution method for measurement of blood flow and volume. Appl. Physiol 6, 731-744 (1954).
    • (1954) Appl. Physiol , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 3
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography
    • L. Axel, Cerebral blood flow determination by rapid-sequence computed tomography. Radiology 137, 679-686 (1980).
    • (1980) Radiology , vol.137 , pp. 679-686
    • Axel, L.1
  • 6
    • 0026048876 scopus 로고
    • Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects
    • G. T. Gobbel, C. E. Cann, J. R. Fike, Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects. Stroke 22, 768-771 (1991).
    • (1991) Stroke , vol.22 , pp. 768-771
    • Gobbel, G.T.1    Cann, C.E.2    Fike, J.R.3
  • 7
    • 0028061727 scopus 로고
    • A deconvolution method for evaluating indicator-dilution curves
    • G. T. Gobbel, J. R. Fike, A deconvolution method for evaluating indicator-dilution curves. Phys. Med. Biol. 39, 1833-1854 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1833-1854
    • Gobbel, G.T.1    Fike, J.R.2
  • 8
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • K. A. Rempp, G. Brix, F. Wenz, C. R. Becker, F. Guckel, W. J. Lorenz, Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 193, 637-641 (1994).
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Guckel, F.5    Lorenz, W.J.6
  • 10
    • 0021687090 scopus 로고
    • Cerebral transit of an intravascular tracer may allow measurement of regional blood volume but not regional flow
    • N. A. Lassen, Cerebral transit of an intravascular tracer may allow measurement of regional blood volume but not regional flow. J. Cereb. Blood Flow Metabol. 4, 633-634 (1984).
    • (1984) J. Cereb. Blood Flow Metabol. , vol.4 , pp. 633-634
    • Lassen, N.A.1
  • 12
    • 0027481892 scopus 로고
    • Pitfalls in MR measurements of tissue blood flow with intravascular tracers: Which mean transit time?
    • R. M. Weisskoff, D. Chesler, J. L. Boxerman, B. R. Rosen, Pitfalls in MR measurements of tissue blood flow with intravascular tracers: which mean transit time? Magn. Reson. Med. 29, 553-559 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 553-559
    • Weisskoff, R.M.1    Chesler, D.2    Boxerman, J.L.3    Rosen, B.R.4
  • 13
    • 0001055912 scopus 로고
    • Cerebral haematocrit in normal man
    • O. A. Larsen, N. A. Lassen, Cerebral haematocrit in normal man. J. Appl. Physiol. 19(4), 571-574 (1964).
    • (1964) J. Appl. Physiol. , vol.19 , Issue.4 , pp. 571-574
    • Larsen, O.A.1    Lassen, N.A.2
  • 18
    • 0014107711 scopus 로고
    • A steady-state transfer function analysis of portions of the circulatory system using indicator dilution techniques
    • C. M. Coulam, H. R. Warner, H. W. Marshall, J. B. Bassingthwaighte, A steady-state transfer function analysis of portions of the circulatory system using indicator dilution techniques. Comput. Biomed. Res. 1, 124-138 (1967).
    • (1967) Comput. Biomed. Res. , vol.1 , pp. 124-138
    • Coulam, C.M.1    Warner, H.R.2    Marshall, H.W.3    Bassingthwaighte, J.B.4
  • 19
    • 0013970673 scopus 로고
    • A Transfer function analysis of coronary and renal circulation calculated from upstream and downstream indicator-dilution curves
    • C. M. Coulam, H. R. Warner, E. H. Wood, J. B. Bassingthwaighte, A Transfer function analysis of coronary and renal circulation calculated from upstream and downstream indicator-dilution curves. Circ. Res. 19, 879-890 (1966).
    • (1966) Circ. Res. , vol.19 , pp. 879-890
    • Coulam, C.M.1    Warner, H.R.2    Wood, E.H.3    Bassingthwaighte, J.B.4
  • 20
    • 0019850140 scopus 로고
    • System parameter identification in transport models using the fast Fourier transform (FFT)
    • C. I. I. I. Wall, H. S. Borovetz, J. J. Murphy, R. L. Hardesty, System parameter identification in transport models using the fast Fourier transform (FFT). Comput. Biomed. Res. 14, 570-581 (1981).
    • (1981) Comput. Biomed. Res. , vol.14 , pp. 570-581
    • Wall, C.I.I.I.1    Borovetz, H.S.2    Murphy, J.J.3    Hardesty, R.L.4
  • 21
    • 0014934541 scopus 로고
    • Blood flow and diffusion through mammalian organs
    • J. B. Bassingthwaighte, Blood flow and diffusion through mammalian organs. Science 167, 1347-1353 (1970).
    • (1970) Science , vol.167 , pp. 1347-1353
    • Bassingthwaighte, J.B.1
  • 24
    • 0021076216 scopus 로고
    • Model-free deconvolution techniques for estimating vascular transport functions
    • T. A. Bronikowski, C. A. Dawson, J. H. Linehan, Model-free deconvolution techniques for estimating vascular transport functions. Int. J. Biomed. Comput. 14, 411-429 (1983).
    • (1983) Int. J. Biomed. Comput. , vol.14 , pp. 411-429
    • Bronikowski, T.A.1    Dawson, C.A.2    Linehan, J.H.3
  • 25
    • 0023870552 scopus 로고
    • Thermal recovery after passage of the pulmonary circulation of the pulmonary circulation assessed by deconvolution
    • J. Bock, P. Deuflhard, A. Hoeft, H. Korb, H.-G. Wolpers, J. Steinman, G. Hellige, Thermal recovery after passage of the pulmonary circulation of the pulmonary circulation assessed by deconvolution. J. Appl. Physiol 64, 1210-1216 (1988).
    • (1988) J. Appl. Physiol , vol.64 , pp. 1210-1216
    • Bock, J.1    Deuflhard, P.2    Hoeft, A.3    Korb, H.4    Wolpers, H.-G.5    Steinman, J.6    Hellige, G.7
  • 26
    • 0023120065 scopus 로고
    • Reliable and efficient deconvolution technique based on total linear least squares for calculating the renal retention function
    • S. Van Huffel, J. Vandewalle, M. C. De Roo, J. L. Willems, Reliable and efficient deconvolution technique based on total linear least squares for calculating the renal retention function. Med. Biol. Eng. Comput. 25, 26-33 (1987).
    • (1987) Med. Biol. Eng. Comput. , vol.25 , pp. 26-33
    • Van Huffel, S.1    Vandewalle, J.2    De Roo, M.C.3    Willems, J.L.4
  • 29
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: Theory and experiment
    • R. M. Weisskoff, C. S. Zuo, J. L. Boxerman, B. R. Rosen BR, Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn. Reson. Med. 31, 601-610 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 30
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • C. R. Fisel, J. L. Ackerman, R. B. Buxton, L. Garrido, J. W. Belliveau, B. R. B. R. Rosen, T. J. Brady, MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn. Reson. Med. 17, 348-356 (1991).
    • (1991) Magn. Reson. Med. , vol.17 , pp. 348-356
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, B.R.B.R.6    Brady, T.J.7
  • 31
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results
    • L. Østergaard, A. G. Sorensen, K. K. Kwong, R. M. Weisskoff, C. Gyldensted, B. R. Rosen. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results. Magn. Reson. Med. 36, 726-736 (1996).
    • (1996) Magn. Reson. Med. , vol.36 , pp. 726-736
    • Østergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3    Weisskoff, R.M.4    Gyldensted, C.5    Rosen, B.R.6
  • 33
    • 0026438833 scopus 로고
    • Computationally efficient algorithms for convection-permeation-diffusion models for blood-tissue exchange
    • J. B. Bassingthwaighte, I. S.J Chan, C. Y. Wang, Computationally efficient algorithms for convection-permeation-diffusion models for blood-tissue exchange. Ann. Biomed. Eng. 20, 687-725 (1992).
    • (1992) Ann. Biomed. Eng. , vol.20 , pp. 687-725
    • Bassingthwaighte, J.B.1    Chan, I.S.J.2    Wang, C.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.