메뉴 건너뛰기




Volumn 50, Issue 1, 2003, Pages 214-219

Simple analytic variable density spiral design

Author keywords

Variable density spirals; Weighted k space sampling

Indexed keywords

ANALYTIC SOLUTION; CARDIAC IMAGING; COMPUTATIONAL POWER; DESIGN PROCESS; K-SPACE SAMPLING; MR SPECTROSCOPIC IMAGING; SPIRAL TRAJECTORIES; VARIABLE DENSITY;

EID: 0038262030     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10493     Document Type: Article
Times cited : (89)

References (15)
  • 1
    • 0029088782 scopus 로고
    • Magnetic resonance fluoroscopy using spirals with variable sampling densities
    • Spielman DM, Pauly JM, Meyer CH. Magnetic resonance fluoroscopy using spirals with variable sampling densities. Magn Reson Med 1995; 34:388-394.
    • (1995) Magn Reson Med , vol.34 , pp. 388-394
    • Spielman, D.M.1    Pauly, J.M.2    Meyer, C.H.3
  • 2
    • 0031003249 scopus 로고    scopus 로고
    • Reduction of motion artifacts in cine MRI using variable-density spiral trajectories
    • Liao JR, Pauly JM, Brosnan TJ, Pelc NJ. Reduction of motion artifacts in cine MRI using variable-density spiral trajectories. Magn Reson Med 1997;37:569-575.
    • (1997) Magn Reson Med , vol.37 , pp. 569-575
    • Liao, J.R.1    Pauly, J.M.2    Brosnan, T.J.3    Pelc, N.J.4
  • 4
    • 0034007629 scopus 로고    scopus 로고
    • Reduced aliasing artifacts using variable-density k-space sampling trajectories
    • Tsai CM, Nishimura DG. Reduced aliasing artifacts using variable-density k-space sampling trajectories. Magn Reson Med 2000;43:452-458.
    • (2000) Magn Reson Med , vol.43 , pp. 452-458
    • Tsai, C.M.1    Nishimura, D.G.2
  • 5
    • 0038620122 scopus 로고    scopus 로고
    • Fast imaging using variable-density spiral trajectories with multi-coil receivers
    • Honolulu
    • Lee JH, Nishimura DG. Fast imaging using variable-density spiral trajectories with multi-coil receivers. In: Proc 10th Scientific Meeting ISMRM, Honolulu, 2002. p 2397.
    • (2002) Proc 10th Scientific Meeting ISMRM , pp. 2397
    • Lee, J.H.1    Nishimura, D.G.2
  • 6
    • 0001119952 scopus 로고
    • High-resolution magnetic resonance spectra from a selective region defined with pulsed field gradients
    • Marcei TH, Brooker HR. High-resolution magnetic resonance spectra from a selective region defined with pulsed field gradients. J Magn Reson 1984;57:157-163.
    • (1984) J Magn Reson , vol.57 , pp. 157-163
    • Marcei, T.H.1    Brooker, H.R.2
  • 9
    • 0032818760 scopus 로고    scopus 로고
    • Simple analytic spiral k-space algorithm
    • Glover GH. Simple analytic spiral k-space algorithm. Magn Reson Med 1999;42:412-415.
    • (1999) Magn Reson Med , vol.42 , pp. 412-415
    • Glover, G.H.1
  • 10
    • 33846926585 scopus 로고
    • Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity
    • Hardy CJ, Cline HE. Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity. J Appl Phys 1989;66:1513-1516.
    • (1989) J Appl Phys , vol.66 , pp. 1513-1516
    • Hardy, C.J.1    Cline, H.E.2
  • 12
    • 0031932352 scopus 로고    scopus 로고
    • Self-navigated spiral fMRI: Interleaved versus single-shot
    • Glover GH, Lai S, Self-navigated spiral fMRI: interleaved versus single-shot. Magn Reson Med 1998;39:361-368.
    • (1998) Magn Reson Med , vol.39 , pp. 361-368
    • Glover, G.H.1    Lai, S.2
  • 13
    • 0035180446 scopus 로고    scopus 로고
    • Design of a logarithmic k-space spiral trajectory
    • Cline HE, Zong X, Gai N. Design of a logarithmic k-space spiral trajectory. Magn Reson Med 2001;46:1130-1135.
    • (2001) Magn Reson Med , vol.46 , pp. 1130-1135
    • Cline, H.E.1    Zong, X.2    Gai, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.