메뉴 건너뛰기




Volumn 20, Issue 5, 2002, Pages 223-229

Two-dimensional magnetic resonance digital subtraction angiography using array spatial sensitivity encoding techniques in the assessment of intracranial hemodynamics

Author keywords

Intracranial hemodynamics; Magnetic resonance angiography; Sensitivity encoding; Temporal resolution

Indexed keywords

GADOLINIUM CHELATE;

EID: 0036761389     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (23)
  • 1
    • 0033860019 scopus 로고    scopus 로고
    • MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas
    • Aoki S, Yoshikawa T, Hori M, et al. MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas. AJR Am J Roentgenol, 175: 451-453, 2000.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 451-453
    • Aoki, S.1    Yoshikawa, T.2    Hori, M.3
  • 2
    • 0034036713 scopus 로고    scopus 로고
    • Time-resolved two-dimensional thick-slice magnetic resonance digital subtraction angiography in assessing brain tumors
    • Yoshikawa T, Aoki S, Hori M, et al. Time-resolved twodimensional thick-slice magnetic resonance digital subtraction angiography in assessing brain tumors. Eur Radiol, 10: 736-744, 2000.
    • (2000) Eur Radiol , vol.10 , pp. 736-744
    • Yoshikawa, T.1    Aoki, S.2    Hori, M.3
  • 3
    • 0034115128 scopus 로고    scopus 로고
    • MR digital subtraction angiography of cerebral arteriovenous malformations
    • Tsuchiya K, Katase S, Yoshino A, et al. MR digital subtraction angiography of cerebral arteriovenous malformations. AJNR Am J Neuroradiol, 21: 707-711, 2000.
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 707-711
    • Tsuchiya, K.1    Katase, S.2    Yoshino, A.3
  • 4
    • 0033739296 scopus 로고    scopus 로고
    • Brain arteriovenous malformations: Assessment with dynamic MR digital subtraction angiography
    • Griffiths PD, Hoggard N, Warren DJ, et al. Brain arteriovenous malformations: Assessment with dynamic MR digital subtraction angiography. AJNR Am J Neuroradiol, 21: 1892-1899, 2000.
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1892-1899
    • Griffiths, P.D.1    Hoggard, N.2    Warren, D.J.3
  • 5
    • 0027477055 scopus 로고
    • 3D TOF MR angiography of cerebral arteriovenous malformations after radiosurgery
    • Kauczor HU, Engenhart R, Layer G, et al. 3D TOF MR angiography of cerebral arteriovenous malformations after radiosurgery. J Comput Assist Tomogr, 17: 184-190, 1993.
    • (1993) J Comput Assist Tomogr , vol.17 , pp. 184-190
    • Kauczor, H.U.1    Engenhart, R.2    Layer, G.3
  • 6
    • 0029121852 scopus 로고
    • Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation
    • Wilcock DJ, Jaspan T, Worthington BS. Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol, 50: 526-532, 1995.
    • (1995) Clin Radiol , vol.50 , pp. 526-532
    • Wilcock, D.J.1    Jaspan, T.2    Worthington, B.S.3
  • 7
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • Prince MR. Gadolinium-enhanced MR aortography. Radiology, 191: 155-164, 1994.
    • (1994) Radiology , vol.191 , pp. 155-164
    • Prince, M.R.1
  • 9
    • 0033812663 scopus 로고    scopus 로고
    • Description of parallel imaging in MRI using multiple coils
    • Wang Y. Description of parallel imaging in MRI using multiple coils. Magn Reson Med, 44: 495-499, 2000.
    • (2000) Magn Reson Med , vol.44 , pp. 495-499
    • Wang, Y.1
  • 10
    • 0033959571 scopus 로고    scopus 로고
    • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme
    • Weiger M, Pruessmann KP, Boesiger P. Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme. Magn Reson Med, 43: 177-184, 2000.
    • (2000) Magn Reson Med , vol.43 , pp. 177-184
    • Weiger, M.1    Pruessmann, K.P.2    Boesiger, P.3
  • 13
    • 0033530420 scopus 로고    scopus 로고
    • Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: A prospective study
    • Bendszus M, Koltzenburg M, Burger R, et al. Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: A prospective study. Lancet, 354: 1594-1597, 1999.
    • (1999) Lancet , vol.354 , pp. 1594-1597
    • Bendszus, M.1    Koltzenburg, M.2    Burger, R.3
  • 14
    • 0024318207 scopus 로고
    • Intracranial circulation: Preliminary clinical results with threedimensional (volume) MR angiography
    • Masaryk TJ, Modic MT, Ross JS, et al. Intracranial circulation: Preliminary clinical results with threedimensional (volume) MR angiography. Radiology, 171: 793-799, 1989.
    • (1989) Radiology , vol.171 , pp. 793-799
    • Masaryk, T.J.1    Modic, M.T.2    Ross, J.S.3
  • 15
    • 0029937898 scopus 로고    scopus 로고
    • Breathhold ultrafast three-dimensional gadolinium enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries
    • Holland GA, Dougherty A, Carpenter JP, et al. Breathhold ultrafast three-dimensional gadolinium enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries. AJR Am J Roentgenol, 166: 971-981, 1996.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 971-981
    • Holland, G.A.1    Dougherty, A.2    Carpenter, J.P.3
  • 16
    • 0030945180 scopus 로고    scopus 로고
    • Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta
    • Prince MR, Chenevert TL, Foo TK, et al. Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta. Radiology, 203: 109-114, 1997.
    • (1997) Radiology , vol.203 , pp. 109-114
    • Prince, M.R.1    Chenevert, T.L.2    Foo, T.K.3
  • 17
    • 0031828885 scopus 로고    scopus 로고
    • Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: Preliminary study of comparison with unenhanced 2D and 3D time-offlight MR angiography
    • Willig DS, Turski PA, Frayne R, et al. Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: Preliminary study of comparison with unenhanced 2D and 3D time-offlight MR angiography. Radiology, 208: 447-451, 1998.
    • (1998) Radiology , vol.208 , pp. 447-451
    • Willig, D.S.1    Turski, P.A.2    Frayne, R.3
  • 18
    • 0031667219 scopus 로고    scopus 로고
    • Carotid artery stenosis, occlusion, and pseudo-occlusion: First-pass, gadolinium-enhanced, three-dimensional MR angiography-preliminary study
    • Remonda L, Heid O, Schrogh G. Carotid artery stenosis, occlusion, and pseudo-occlusion: First-pass, gadoliniumenhanced, three-dimensional MR angiography-preliminary study. Radiology, 209: 95-102, 1998.
    • (1998) Radiology , vol.209 , pp. 95-102
    • Remonda, L.1    Heid, O.2    Schrogh, G.3
  • 19
    • 0031906598 scopus 로고    scopus 로고
    • Extracranial atherosclerotic carotid artery disease: Evaluation of nonbreath-hold three-dimensional gadolinium-enhanced MR angiography
    • Slosman F, Stolpen AH, Lexa FJ, et al. Extracranial atherosclerotic carotid artery disease: Evaluation of nonbreath-hold three-dimensional gadolinium-enhanced MR angiography. AJR Am J Roentgenol, 170: 489-495, 1998.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 489-495
    • Slosman, F.1    Stolpen, A.H.2    Lexa, F.J.3
  • 20
    • 0031725522 scopus 로고    scopus 로고
    • Three-dimensional high-resolution dynamic contrast-enhanced MR angiography of the pelvis and lower extremities with use of a phased array coil and subtraction: Diagnostic accuracy
    • Yamashita Y, Mitsuzaki K, Ogata I, et al. Three-dimensional high-resolution dynamic contrast-enhanced MR angiography of the pelvis and lower extremities with use of a phased array coil and subtraction: Diagnostic accuracy. J Magn Reson Imaging, 8: 1066-1072, 1998.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1066-1072
    • Yamashita, Y.1    Mitsuzaki, K.2    Ogata, I.3
  • 21
    • 0031806088 scopus 로고    scopus 로고
    • Contrast-enhanced 3D MRA with centric ordering in k space: A preliminary clinical experience in imaging the abdominal aorta and renal and peripheral arterial vasculature
    • Shetty AN, Bis KG, Vrachliotis TG, et al. Contrast-enhanced 3D MRA with centric ordering in k space: A preliminary clinical experience in imaging the abdominal aorta and renal and peripheral arterial vasculature. J Magn Reson Imaging, 8: 603-615, 1998.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 603-615
    • Shetty, A.N.1    Bis, K.G.2    Vrachliotis, T.G.3
  • 22
    • 0031814822 scopus 로고    scopus 로고
    • Arterial phase carotid and vertebral artery imaging in 3D contrast-enhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order
    • Wilman AH, Riederer SJ, Huston J IH, et al. Arterial phase carotid and vertebral artery imaging in 3D contrastenhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order. Magn Reson Med, 40: 24-35, 1998.
    • (1998) Magn Reson Med , vol.40 , pp. 24-35
    • Wilman, A.H.1    Riederer, S.J.2    Huston, J.I.H.3
  • 23
    • 0030739513 scopus 로고    scopus 로고
    • Contrast-enhanced magnetic resonance angiography. Theory, technique and practical application
    • Stehling MK, Niedermeyer M, Laub G. Contrast-enhanced magnetic resonance angiography. Theory, technique and practical application. Radiologe, 37: 501-507, 1997.
    • (1997) Radiologe , vol.37 , pp. 501-507
    • Stehling, M.K.1    Niedermeyer, M.2    Laub, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.