-
1
-
-
0024273739
-
Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients
-
Shoemaker WC, Appel PL, Kram HB, et al. Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest 1988; 94:1176-1186.
-
(1988)
Chest
, vol.94
, pp. 1176-1186
-
-
Shoemaker, W.C.1
Appel, P.L.2
Kram, H.B.3
-
2
-
-
0027427633
-
A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients
-
Boyd O, Grounds RM, Bennett ED. A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 1993; 270:2699-2707.
-
(1993)
JAMA
, vol.270
, pp. 2699-2707
-
-
Boyd, O.1
Grounds, R.M.2
Bennett, E.D.3
-
3
-
-
0033599760
-
Reducing the risk of major elective surgery: Randomised controlled trial of preoperative optimisation of oxygen delivery
-
Wilson J, Woods I, Fawcett J, et al. Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery. BMJ 1999; 318:1099-1103.
-
(1999)
BMJ
, vol.318
, pp. 1099-1103
-
-
Wilson, J.1
Woods, I.2
Fawcett, J.3
-
4
-
-
34247550916
-
Prospective, randomized trial comparing fluids and dobutamine optimization of oxygen delivery in high-risk surgical patients ISRCTN42445141
-
Lobo SM, Lobo FR, Polachini CA, et al. Prospective, randomized trial comparing fluids and dobutamine optimization of oxygen delivery in high-risk surgical patients ISRCTN42445141. Crit Care Med 2006; 10:R72.
-
(2006)
Crit Care Med
, vol.10
-
-
Lobo, S.M.1
Lobo, F.R.2
Polachini, C.A.3
-
5
-
-
0036342470
-
Meta-analysis of hemodynamic optimization in high-risk patients
-
Kern JW, Shoemaker WC. Meta-analysis of hemodynamic optimization in high-risk patients. Crit Care Med 2002; 30:1686-1692.
-
(2002)
Crit Care Med
, vol.30
, pp. 1686-1692
-
-
Kern, J.W.1
Shoemaker, W.C.2
-
6
-
-
0030843904
-
Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
-
Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 1997; 315:909-912.
-
(1997)
BMJ
, vol.315
, pp. 909-912
-
-
Sinclair, S.1
James, S.2
Singer, M.3
-
7
-
-
0036792321
-
Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery
-
Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 2002; 97:820-826.
-
(2002)
Anesthesiology
, vol.97
, pp. 820-826
-
-
Gan, T.J.1
Soppitt, A.2
Maroof, M.3
-
8
-
-
33748419499
-
Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection
-
Noblett SE, Snowden CP, Shenton BK, Horgan AF. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg 2006; 93:1069-1076.
-
(2006)
Br J Surg
, vol.93
, pp. 1069-1076
-
-
Noblett, S.E.1
Snowden, C.P.2
Shenton, B.K.3
Horgan, A.F.4
-
9
-
-
34347222567
-
Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France
-
27-28 April
-
Antonelli M, Levy M, Andrews PJ, et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006. Intensive Care Med 2007; 33:575-590. This consensus conference is the first to address the evidence behind cardiac output monitoring in shock.
-
(2006)
Intensive Care Med 2007; 33:575-590. This consensus conference is the first to address the evidence behind cardiac output monitoring in shock
-
-
Antonelli, M.1
Levy, M.2
Andrews, P.J.3
-
10
-
-
26944486636
-
Noninvasive techniques for measurements of cardiac output
-
Cholley BP, Payen D. Noninvasive techniques for measurements of cardiac output. Curr Opin Crit Care 2005; 11:424-429.
-
(2005)
Curr Opin Crit Care
, vol.11
, pp. 424-429
-
-
Cholley, B.P.1
Payen, D.2
-
11
-
-
2942564478
-
Equipment review: An appraisal of the LiDCO plus method of measuring cardiac output
-
Pearse RM, Ikram K, Barry J. Equipment review: an appraisal of the LiDCO plus method of measuring cardiac output. Crit Care 2004; 8:190-195.
-
(2004)
Crit Care
, vol.8
, pp. 190-195
-
-
Pearse, R.M.1
Ikram, K.2
Barry, J.3
-
12
-
-
0033503137
-
A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride
-
Jonas MM, Kelly FE, Linton RA, et al. A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride. J Clin Monit Comput 1999; 15:525-528.
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 525-528
-
-
Jonas, M.M.1
Kelly, F.E.2
Linton, R.A.3
-
13
-
-
0030832772
-
Lithium dilution cardiac output measurement: A comparison with thermodilution
-
Linton R, Band D, O'Brien T, et al. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med 1997; 25:1796-1800.
-
(1997)
Crit Care Med
, vol.25
, pp. 1796-1800
-
-
Linton, R.1
Band, D.2
O'Brien, T.3
-
14
-
-
0033934008
-
Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses
-
Linton RA, Young LE, Marlin DJ, et al. Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses. Am J Vet Res 2000; 61:731-737.
-
(2000)
Am J Vet Res
, vol.61
, pp. 731-737
-
-
Linton, R.A.1
Young, L.E.2
Marlin, D.J.3
-
15
-
-
0033787516
-
Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
-
Linton RA, Jonas MM, Tibby SM, et al. Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit. Intensive Care Med 2000; 26:1507-1511.
-
(2000)
Intensive Care Med
, vol.26
, pp. 1507-1511
-
-
Linton, R.A.1
Jonas, M.M.2
Tibby, S.M.3
-
16
-
-
38849093827
-
Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs. lithium dilution technique
-
Costa MG, Della Rocca G, Chiarandini P, et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2007; 34:257-263.
-
(2007)
Intensive Care Med
, vol.34
, pp. 257-263
-
-
Costa, M.G.1
Della Rocca, G.2
Chiarandini, P.3
-
17
-
-
34250893209
-
Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs
-
Cooper ES, Muir WW. Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs. Crit Care Med 2007; 35:1724-1729.
-
(2007)
Crit Care Med
, vol.35
, pp. 1724-1729
-
-
Cooper, E.S.1
Muir, W.W.2
-
18
-
-
41549163951
-
A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
-
Cecconi M, Fawcett J, Grounds RM, Rhodes A. A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008; 8:3.
-
(2008)
BMC Anesthesiol
, vol.8
, pp. 3
-
-
Cecconi, M.1
Fawcett, J.2
Grounds, R.M.3
Rhodes, A.4
-
19
-
-
33845321475
-
Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial ISRCTN38797445
-
Pearse R, Dawson D, Fawcett J, et al. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial ISRCTN38797445. Crit Care 2005; 9:R687-R693.
-
(2005)
Crit Care
, vol.9
-
-
Pearse, R.1
Dawson, D.2
Fawcett, J.3
-
20
-
-
43449108082
-
-
PULSION Medical Systems AG, Munich, Germany. PiCCO
-
PULSION Medical Systems AG, Munich, Germany. PiCCO.
-
-
-
-
21
-
-
38549151697
-
Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
-
Hamzaoui O, Monnet X, Richard C, et al. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008; 36:434-440.
-
(2008)
Crit Care Med
, vol.36
, pp. 434-440
-
-
Hamzaoui, O.1
Monnet, X.2
Richard, C.3
-
22
-
-
43449105705
-
-
Salukhe T, Wyncoll D. Volumetric haemodynamic monitoring and continuous pulse contour analysis - an untapped resource for coronary and high dependency care units? Br J Cardiol (Acute Interv Cardiol) 2002; 9:AIC20-AIC25.
-
Salukhe T, Wyncoll D. Volumetric haemodynamic monitoring and continuous pulse contour analysis - an untapped resource for coronary and high dependency care units? Br J Cardiol (Acute Interv Cardiol) 2002; 9:AIC20-AIC25.
-
-
-
-
23
-
-
0142149221
-
Cardiac output monitoring: Aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation
-
Della Rocca G, Costa MG, Coccia C, et al. Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 2003; 50:707-711.
-
(2003)
Can J Anaesth
, vol.50
, pp. 707-711
-
-
Della Rocca, G.1
Costa, M.G.2
Coccia, C.3
-
24
-
-
0036198399
-
Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
-
Della Rocca G, Costa MG, Pompei L, et al. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002; 88:350-356.
-
(2002)
Br J Anaesth
, vol.88
, pp. 350-356
-
-
Della Rocca, G.1
Costa, M.G.2
Pompei, L.3
-
25
-
-
0036172926
-
Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients
-
Sakka SG, Reinhart K, Wegscheider K, Meier-Hellmann A. Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients. Chest 2002; 121:559-565.
-
(2002)
Chest
, vol.121
, pp. 559-565
-
-
Sakka, S.G.1
Reinhart, K.2
Wegscheider, K.3
Meier-Hellmann, A.4
-
26
-
-
33846786705
-
Pulmonary artery catheter versus pulse contour analysis: A prospective epidemiological study
-
This paper showed no difference in outcome between PiCCO and PAFC guided therapy. However, the PiCCO patients received more intravenous fluids and required a longer duration of mechanical ventilation
-
Uchino S, Bellomo R, Morimatsu H, et al. Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study. Crit Care 2006; 10:R174. This paper showed no difference in outcome between PiCCO and PAFC guided therapy. However, the PiCCO patients received more intravenous fluids and required a longer duration of mechanical ventilation.
-
(2006)
Crit Care
, vol.10
-
-
Uchino, S.1
Bellomo, R.2
Morimatsu, H.3
-
27
-
-
33846323221
-
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
-
Goepfert MS, Reuter DA, Akyol D, et al. Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007; 33:96-103.
-
(2007)
Intensive Care Med
, vol.33
, pp. 96-103
-
-
Goepfert, M.S.1
Reuter, D.A.2
Akyol, D.3
-
28
-
-
43449130184
-
-
Edwards Lifesciences. Edwards Vigileo monitor. http://www.edwards.com/ products/mininvasive/vigileo.htm.
-
Edwards Vigileo monitor
-
-
-
29
-
-
43449092665
-
-
Edwards Lifesciences. Edwards Flotrac sensor. http://www.edwards.com/ products/mininvasive/flotracsensor.htm.
-
Edwards Flotrac sensor
-
-
-
30
-
-
34247551188
-
Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
-
Sander M, Spies CD, Grubitzsch H, et al. Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006; 10:R164.
-
(2006)
Crit Care
, vol.10
-
-
Sander, M.1
Spies, C.D.2
Grubitzsch, H.3
-
31
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15:85-91.
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 85-91
-
-
Critchley, L.A.1
Critchley, J.A.2
-
32
-
-
34548329959
-
-
Al-Subaie N, Bennett D. Year in review 2006: Critical Care Cardiology. Crit Care 2007; 11:225.
-
Al-Subaie N, Bennett D. Year in review 2006: Critical Care Cardiology. Crit Care 2007; 11:225.
-
-
-
-
33
-
-
33846894301
-
A pilot assessment of the FloTrac(TM) cardiac output monitoring system
-
Opdam HI, Wan L, Bellomo R. A pilot assessment of the FloTrac(TM) cardiac output monitoring system. Intensive Care Med 2007; 33:344-349.
-
(2007)
Intensive Care Med
, vol.33
, pp. 344-349
-
-
Opdam, H.I.1
Wan, L.2
Bellomo, R.3
-
34
-
-
33847753396
-
Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
-
Mayer J, Boldt J, Schollhorn T, et al. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007; 98:176-182.
-
(2007)
Br J Anaesth
, vol.98
, pp. 176-182
-
-
Mayer, J.1
Boldt, J.2
Schollhorn, T.3
-
35
-
-
34548655920
-
Continuous cardiac output measurement: Arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass
-
Lorsomradee S, Lorsomradee SR, Cromheecke S, De Hert SG. Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass. Anaesthesia 2007; 62:979-983.
-
(2007)
Anaesthesia
, vol.62
, pp. 979-983
-
-
Lorsomradee, S.1
Lorsomradee, S.R.2
Cromheecke, S.3
De Hert, S.G.4
-
36
-
-
34648831355
-
Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform
-
Lorsomradee S, Lorsomradee S, Cromheecke S, De Hert SG. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth 2007; 21:636-643.
-
(2007)
J Cardiothorac Vasc Anesth
, vol.21
, pp. 636-643
-
-
Lorsomradee, S.1
Lorsomradee, S.2
Cromheecke, S.3
De Hert, S.G.4
-
37
-
-
34548254794
-
Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
-
This paper studied the use of noncalibrated cardiac output monitoring in septic patients
-
Sakka SG, Kozieras J, Thuemer O, van Hout N. Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007; 99:337-342. This paper studied the use of noncalibrated cardiac output monitoring in septic patients.
-
(2007)
Br J Anaesth
, vol.99
, pp. 337-342
-
-
Sakka, S.G.1
Kozieras, J.2
Thuemer, O.3
van Hout, N.4
-
38
-
-
36549031653
-
Validation of a continuous, arterial pressure-based cardiac output measurement: A multicenter, prospective clinical trial
-
This study found that Vigileo derived cardiac output monitoring is comparable to PAFC continuous cardiac output monitoring
-
McGee WT, Horswell JL, Calderon J, et al. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. Crit Care 2007; 11:R105. This study found that Vigileo derived cardiac output monitoring is comparable to PAFC continuous cardiac output monitoring.
-
(2007)
Crit Care
, vol.11
-
-
McGee, W.T.1
Horswell, J.L.2
Calderon, J.3
-
39
-
-
0036385496
-
Lack of agreement between thermodilution and fick cardiac output in critically ill patients
-
Dhingra VK, Fenwick JC, Walley KR, et al. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Chest 2002; 122:990-997.
-
(2002)
Chest
, vol.122
, pp. 990-997
-
-
Dhingra, V.K.1
Fenwick, J.C.2
Walley, K.R.3
-
40
-
-
34548266524
-
Clinical evaluation of the FloTrac/ Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
-
This study compared both calibrated and noncalibrated cardiac output monitoring with PAFC derived monitoring
-
Button D, Weibel L, Reuthebuch O, et al. Clinical evaluation of the FloTrac/ Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007; 99:329-336. This study compared both calibrated and noncalibrated cardiac output monitoring with PAFC derived monitoring.
-
(2007)
Br J Anaesth
, vol.99
, pp. 329-336
-
-
Button, D.1
Weibel, L.2
Reuthebuch, O.3
-
41
-
-
34547699294
-
Validation of a new arterial pulse contour-based cardiac output device
-
de Waal EE, Kalkman CJ, Rex S, Buhre WF. Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007; 35:1904-1909.
-
(2007)
Crit Care Med
, vol.35
, pp. 1904-1909
-
-
de Waal, E.E.1
Kalkman, C.J.2
Rex, S.3
Buhre, W.F.4
-
42
-
-
34648816655
-
Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
-
Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld AB. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth 2007; 21:632-635.
-
(2007)
J Cardiothorac Vasc Anesth
, vol.21
, pp. 632-635
-
-
Breukers, R.M.1
Sepehrkhouy, S.2
Spiegelenberg, S.R.3
Groeneveld, A.B.4
|