Volumn 3, Issue 4, 2004, Pages 309-324

Detectors for digital mammography

Author keywords

[No Author keywords available]

Indexed keywords

BREAST; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST SENSITIVITY; DIGITAL RADIOGRAPHY; DISPLAY SYSTEM; ELECTRONICS; ENERGY ABSORPTION; GEOMETRY; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGING SYSTEM; MAMMOGRAPHY; MATHEMATICAL ANALYSIS; QUANTUM MECHANICS; RADIATION DOSE; RADIATION ENERGY; RADIATION EXPOSURE; RADIOLOGICAL PARAMETERS; REVIEW; SIGNAL NOISE RATIO; X RAY; X RAY FILM;

EID: 4143098087     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.1177/153303460400300401     Document Type: Review
Times cited : (22)

References (44)
  • 1
    • 58149413803 scopus 로고
    • Ed. Way. K. Academic Press
    • Storm, E. and Isreal, H. I. Nuclear Data Tables, Vol. A7. pp. 565-681. Ed. Way. K. Academic Press (1970).
    • (1970) Nuclear Data Tables , vol.A7 , pp. 565-681
    • Storm, E.1    Isreal, H.I.2
  • 2
    • 0034767933 scopus 로고    scopus 로고
    • Parallel cascades: New ways to describe noise transfer in medical imaging systems
    • Yao, J. and Cunningham, I. A. Parallel Cascades: New Ways to Describe Noise Transfer in Medical Imaging Systems. Med. Phys. 28, 2020-2038 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2020-2038
    • Yao, J.1    Cunningham, I.A.2
  • 3
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • Que, W. and Rowlands, J. A. X-ray Imaging Using Amorphous Selenium: Inherent Spatial Resolution. Med. Phys. 22, 365-374 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 4
    • 0028917934 scopus 로고
    • X-ray imaging with amorphous selenium: Detective quantum efficiency of photoconductive receptors for digital mammography
    • Fahrig, R., Rowlands, J. A., and Yaffe, M. J. X-ray Imaging with Amorphous Selenium: Detective Quantum Efficiency of Photoconductive Receptors for Digital Mammography. Med. Phys. 22, 153-160 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 153-160
    • Fahrig, R.1    Rowlands, J.A.2    Yaffe, M.J.3
  • 5
    • 0017066097 scopus 로고
    • The line spread function and modulation transfer function of a computed tomographic scanner
    • Judy, P. F. The Line Spread Function and Modulation Transfer Function of a Computed Tomographic Scanner. Med. Phys. 3, 233-236 (1976).
    • (1976) Med. Phys. , vol.3 , pp. 233-236
    • Judy, P.F.1
  • 6
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei, E., Flynn, M. J., and Reimann, D. A. A Method for Measuring the Presampled MTF of Digital Radiographic Systems Using an Edge Test Device. Med. Phys. 25, 102-113 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 7
    • 0015667930 scopus 로고
    • Absorption and noise in X-ray phosphors
    • Swank, R. K. Absorption and Noise in X-ray Phosphors. J. Appl. Phys. 44, 4199-4203 (1973).
    • (1973) J. Appl. Phys. , vol.44 , pp. 4199-4203
    • Swank, R.K.1
  • 9
    • 0042376256 scopus 로고    scopus 로고
    • Standardization of NPS measurement: Interim report of AAPM TGI6
    • Maidment, A. D. A., Albert, M., Bunch, P. C., and Cunningham, I. A. Standardization of NPS Measurement: Interim Report of AAPM TGI6. Proc. SPIE 5030, 523-532 (2003).
    • (2003) Proc. SPIE , vol.5030 , pp. 523-532
    • Maidment, A.D.A.1    Albert, M.2    Bunch, P.C.3    Cunningham, I.A.4
  • 12
    • 58749103831 scopus 로고    scopus 로고
    • Degradation of the detective quantum efficiency due to a non-unity fill factor
    • Cunningham, I. A. Degradation of the Detective Quantum Efficiency Due to a Non-unity Fill Factor. Proc SPIE 3032, 22-31 (1997).
    • (1997) Proc. SPIE , vol.3032 , pp. 22-31
    • Cunningham, I.A.1
  • 13
    • 0031439126 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency
    • Zhao, W. and Rowlands, J. A. Digital Radiology Using Active Matrix Readout of Amorphous Selenium: Theoretical Analysis of Detective Quantum Efficiency. Med. Phys. 24, 1819-1833 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1819-1833
    • Zhao, W.1    Rowlands, J.A.2
  • 14
    • 0032594449 scopus 로고    scopus 로고
    • Optimization of the presampling modulation transfer function of flat-panel detectors for digital radiology
    • Rowlands, J. A. and Ji, W. G. Optimization of the Presampling Modulation Transfer Function of Flat-panel Detectors for Digital Radiology. Proc. SPIE 3659, 66-75 (1999).
    • (1999) Proc. SPIE , vol.3659 , pp. 66-75
    • Rowlands, J.A.1    Ji, W.G.2
  • 15
    • 0033749173 scopus 로고    scopus 로고
    • Direct-conversion flat-panel X-ray imaging: Reduction of noise by presampling filtration
    • Rowlands, J. A., Ji, W. G., Zhao, W., and Lee, D. L. Direct-conversion Flat-panel X-ray Imaging: Reduction of Noise by Presampling Filtration. Proc. SPIE 3977, 446-455 (2000).
    • (2000) Proc. SPIE , vol.3977 , pp. 446-455
    • Rowlands, J.A.1    Ji, W.G.2    Zhao, W.3    Lee, D.L.4
  • 16
    • 0034871963 scopus 로고    scopus 로고
    • What does DQE say about lesion detectability in digital radiography?
    • Pineda, A. R. and Barren, H. H. What Does DQE Say About Lesion Detectability in Digital Radiography? Proc. SPIE 4320, 561-569 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 561-569
    • Pineda, A.R.1    Barren, H.H.2
  • 18
    • 0041374313 scopus 로고    scopus 로고
    • Performance of advanced a-si/CsI-based flat panel X-ray detectors for mammography
    • Albagli, D., Hudspeth, H., Possin, G., Lee, J., Granfors, P, and Giambattista, B. Performance of Advanced a-si/CsI-based Flat Panel X-ray Detectors for Mammography. Proc. SPIE 5030, 553-563 (2003).
    • (2003) Proc. SPIE , vol.5030 , pp. 553-563
    • Albagli, D.1    Hudspeth, H.2    Possin, G.3    Lee, J.4    Granfors, P.5    Giambattista, B.6
  • 19
  • 20
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • Rowlands, J. A. The Physics of Computed Radiography. Phys. Med. Biol. 47, R123-R166 (2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Rowlands, J.A.1
  • 21
    • 0033731305 scopus 로고    scopus 로고
    • Improvement of image quality in CR mammography by detection of emissions from dual sides of an imaging plate
    • Arakawa, S., Yasuda, H., Kohda, K., and Suzuki, T. Improvement of Image Quality in CR Mammography by Detection of Emissions From Dual Sides of an Imaging Plate. Proc. SPIE. 590-600 (2000).
    • (2000) Proc. SPIE. , pp. 590-600
    • Arakawa, S.1    Yasuda, H.2    Kohda, K.3    Suzuki, T.4
  • 23
    • 0034874464 scopus 로고    scopus 로고
    • Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography
    • Zhao, W., Ji, W. G., Rowlands, J. A., and Debrie, A. Investigation of Imaging Performance of Amorphous Selenium Flat-panel Detectors for Digital Mammography. Proc. SPIE 4320, 536-546 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 536-546
    • Zhao, W.1    Ji, W.G.2    Rowlands, J.A.3    Debrie, A.4
  • 24
    • 0036033208 scopus 로고    scopus 로고
    • Characterization of a full field digital mammography detector based on direct X-ray conversion in selenium
    • Yorker, J. G., Jeromin, L. S., Lee, D. L. Y., Palecki, E. F., Golden, K. P., and Jing, Z. Characterization of a Full Field Digital Mammography Detector Based on Direct X-ray Conversion in Selenium. Proc. SPIE 4682, 21-29 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 21-29
    • Yorker, J.G.1    Jeromin, L.S.2    Lee, D.L.Y.3    Palecki, E.F.4    Golden, K.P.5    Jing, Z.6
  • 28
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on X-ray energy weighting in mammography
    • Cahn, R. N., Cederstrom, B., Danielsson, M., Hall, A., Lundqvist, M., and Nygren, D. Detective Quantum Efficiency Dependence on X-ray Energy Weighting in Mammography. Med. Phys. 26, 2680-2683 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 32
    • 0032403949 scopus 로고    scopus 로고
    • Thin-film transistor array technology for high-performance direct-conversion X-ray sensors
    • Boer, W. D., Aggas, S., Byun, Y. H., Gu, T., Zhong, J. Q., Thomsen, S. V., Jeromin, L. S., and Lee, D. L. Thin-film Transistor Array Technology for High-performance Direct-conversion X-ray Sensors. Proc. SPIE 3336, 520-528 (1998).
    • (1998) Proc. SPIE , vol.3336 , pp. 520-528
    • Boer, W.D.1    Aggas, S.2    Byun, Y.H.3    Gu, T.4    Zhong, J.Q.5    Thomsen, S.V.6    Jeromin, L.S.7    Lee, D.L.8
  • 33
    • 0141629469 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced digital subtraction mammography: Feasibility
    • Lewin, J. M., Isaacs, P. K., Vance, V., and Larke, F. J. Dual-energy Contrast-enhanced Digital Subtraction Mammography: Feasibility. Radiology 229, 261-268 (2003).
    • (2003) Radiology , vol.229 , pp. 261-268
    • Lewin, J.M.1    Isaacs, P.K.2    Vance, V.3    Larke, F.J.4
  • 34
    • 0038715562 scopus 로고    scopus 로고
    • Dual-energy digital mammography: Calibration and inverse-mapping techniques to estimate calcification thickness and glandular-tissue ratio
    • Kappadath, S. C. and Shaw, C. C. Dual-energy Digital Mammography: Calibration and Inverse-mapping Techniques to Estimate Calcification Thickness and Glandular-tissue Ratio. Med Phys 30, 1110-1117 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1110-1117
    • Kappadath, S.C.1    Shaw, C.C.2
  • 35
    • 0036188826 scopus 로고    scopus 로고
    • Computer-aided diagnosis in radiology
    • Giger, M. L. Computer-aided Diagnosis in Radiology. Acad. Radiol. 9, 1 (2002).
    • (2002) Acad. Radiol. , vol.9 , pp. 1
    • Giger, M.L.1
  • 42
    • 0037342983 scopus 로고    scopus 로고
    • A volumetric method for estimation of breast density on digitized screen-film mammograms
    • Pawluczyk, O., Augustine, B. J., Yaffe, M. J., Rico, D., Yang, J., Mawdsley, G. E., and Boyd, N. F. A Volumetric Method for Estimation of Breast Density on Digitized Screen-film Mammograms. Med Phys 30, 352-364 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 352-364
    • Pawluczyk, O.1    Augustine, B.J.2    Yaffe, M.J.3    Rico, D.4    Yang, J.5    Mawdsley, G.E.6    Boyd, N.F.7
  • 43
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story spatio-temporal response characteristics of an indirect-detection flat-panel imager
    • Siewerdsen, J. H. and Jaffray, D. A. A Ghost Story: Spatio-temporal Response Characteristics of an Indirect-detection Flat-panel Imager. Med Phys 26, 1624-1641 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1624-1641
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 44
    • 0036033452 scopus 로고    scopus 로고
    • Investigation of lag and ghosting in amorphous selenium flat-panel X-ray detectors
    • Zhao, W, DeCrescenzo, G., and Rowlands, J. A. Investigation of Lag and Ghosting in Amorphous Selenium Flat-panel X-ray Detectors. Proc. SPIE 4682, 9-20 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 9-20
    • Zhao, W.1    DeCrescenzo, G.2    Rowlands, J.A.3