MOSFET sensitivity dependence on integrated dose from high-energy photon beams

Author keywords

Dose response; MOSFET; Radiation measurement

Indexed keywords

DOSIMETRY; LOGIC DESIGN; MOSFET DEVICES; PHOTONS;

EID: 37549071493     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2815626     Document Type: Article
Times cited : (12)

References (21)
  • 1
    • 0021234892 scopus 로고
    • Radiation dosimetry with MOS sensors
    • 0094-2405
    • I. Thomson, R. E. Thomas, and L. P. Berndt, " Radiation dosimetry with MOS sensors., " Radiat. Prot. Dosim. 6, 121-124 (1984). 0094-2405
    • (1984) Radiat. Prot. Dosim. , vol.6 , pp. 121-124
    • Thomson, I.1    Thomas, R.E.2    Berndt, L.P.3
  • 2
    • 0028213977 scopus 로고    scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • 0094-2405 10.1118/1.597314
    • M. Soubra, J. E. Cygler, and G. Mackay, " Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter., " Med. Phys. 0094-2405 10.1118/1.597314 21, 567-572 (1999).
    • (1999) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.E.2    MacKay, G.3
  • 5
    • 1642393118 scopus 로고    scopus 로고
    • Characteristics and performance of a micro-MOSFET: An "imageable" dosimeter for image guided radiotherapy
    • 0094-2405 10.1118/1.1649532
    • C. G. Rowbottom and D. A. Jaffray, " Characteristics and performance of a micro-MOSFET: An "imageable" dosimeter for image guided radiotherapy., " Med. Phys. 0094-2405 10.1118/1.1649532 31, 609-615 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 609-615
    • Rowbottom, C.G.1    Jaffray, D.A.2
  • 6
    • 0031899494 scopus 로고    scopus 로고
    • Calibration of a MOSFET detection system for 6 MV in vivo dosimetry
    • 0360-3016
    • P. Scalchi and P. Francescon, " Calibration of a MOSFET detection system for 6 MV in vivo dosimetry., " Int. J. Radiat. Oncol. Biol. Phys. 40, 987-993 (1998). 0360-3016
    • (1998) Int. J. Radiat. Oncol. Biol. Phys. , vol.40 , pp. 987-993
    • Scalchi, P.1    Francescon, P.2
  • 7
    • 0033013459 scopus 로고    scopus 로고
    • Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology
    • 0007-1285
    • D. J. Peet and M. D. Pryor, " Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology., " Br. J. Radiol. 72, 562-568 (1999). 0007-1285
    • (1999) Br. J. Radiol. , vol.72 , pp. 562-568
    • Peet, D.J.1    Pryor, M.D.2
  • 8
    • 0033853810 scopus 로고    scopus 로고
    • Measurement of radiotherapy x-ray skin dose on a chest wall phantom
    • 0094-2405 10.1118/1.599035
    • K. Y. Quach, J. Marales, M. J. Butson, A. B. Rosenfeld, and P. E. Metcalfe, " Measurement of radiotherapy x-ray skin dose on a chest wall phantom., " Med. Phys. 0094-2405 10.1118/1.599035 27, 1676-1680 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1676-1680
    • Quach, K.Y.1    Marales, J.2    Butson, M.J.3    Rosenfeld, A.B.4    Metcalfe, P.E.5
  • 9
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • 0094-2405 10.1118/1.1481520
    • C. F. Chuang, L. J. Verhey, and P. Xia, " Investigation of the use of MOSFET for clinical IMRT dosimetric verification., " Med. Phys. 0094-2405 10.1118/1.1481520 29, 1109-1115 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 10
    • 0036390047 scopus 로고    scopus 로고
    • MOSFET dosimetry on modern radiation oncology modalities
    • 0144-8420
    • A. B. Rosenfeld, " MOSFET dosimetry on modern radiation oncology modalities., " Radiat. Prot. Dosimetry 101, 393-398 (2002). 0144-8420
    • (2002) Radiat. Prot. Dosimetry , vol.101 , pp. 393-398
    • Rosenfeld, A.B.1
  • 11
    • 4544233994 scopus 로고    scopus 로고
    • Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy
    • 0031-9155 10.1088/0031-9155/49/17/014
    • R. Ramaseshan, K. S. Kohli, T. J. Zhang, T. Lam, B. Norlinger, A. Hallil, and M. Islam, " Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/17/014 49, 4031-4048 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4031-4048
    • Ramaseshan, R.1    Kohli, K.S.2    Zhang, T.J.3    Lam, T.4    Norlinger, B.5    Hallil, A.6    Islam, M.7
  • 13
    • 33749392945 scopus 로고    scopus 로고
    • Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and C 60 o
    • 0094-2405 10.1118/1.2349301
    • M. C. Lavallee, L. Gringas, and L. Beaulieu, " Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and C 60 o., " Med. Phys. 0094-2405 10.1118/1.2349301 33, 3683-3689 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 3683-3689
    • Lavallee, M.C.1    Gringas, L.2    Beaulieu, L.3
  • 14
    • 4644311758 scopus 로고    scopus 로고
    • Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
    • 0094-2405 10.1118/1.1785452
    • N. Jornet, P. Carrasco, D. Jurado, A. Ruiz, T. Eudaldo, and M. Ribas, " Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams., " Med. Phys. 0094-2405 10.1118/1.1785452 31, 2534-2542 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2534-2542
    • Jornet, N.1    Carrasco, P.2    Jurado, D.3    Ruiz, A.4    Eudaldo, T.5    Ribas, M.6
  • 15
    • 0038107834 scopus 로고    scopus 로고
    • Total ionizing dose effects in MOS oxides and devices
    • 0018-9499 10.1109/TNS.2003.812927
    • T. R. Oldham and F. B. McLean, " Total ionizing dose effects in MOS oxides and devices., " IEEE Trans. Nucl. Sci. 0018-9499 10.1109/TNS.2003.812927 50, 483-499 (2003).
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 483-499
    • Oldham, T.R.1    McLean, F.B.2
  • 16
    • 0028062816 scopus 로고
    • A miniature MOSFET radiation dosimeter probe
    • 0094-2405 10.1118/1.597214
    • D. J. Gladstone, X. Q. Lu, J. L. Humm, H. F. Bowman, and L. M. Chin, " A miniature MOSFET radiation dosimeter probe., " Med. Phys. 0094-2405 10.1118/1.597214 21, 1721-1728 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1721-1728
    • Gladstone, D.J.1    Lu, X.Q.2    Humm, J.L.3    Bowman, H.F.4    Chin, L.M.5
  • 17
    • 3442897997 scopus 로고    scopus 로고
    • Effects of temperature variation on MOSFET dosimetry
    • 0031-9155 10.1088/0031-9155/49/13/N02
    • T. Cheung, M. J. Butson, and P. K. N. Yu, " Effects of temperature variation on MOSFET dosimetry., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/13/N02 49, N191-N196 (2004).
    • (2004) Phys. Med. Biol. , vol.49
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 18
    • 0038107810 scopus 로고    scopus 로고
    • A review of the 40-year history of the NSREC's dosimetry and facilities session (1963-2003)
    • 0018-9499
    • W. Beezhold and D. E. Beutler, " A review of the 40-year history of the NSREC's dosimetry and facilities session (1963-2003)., " IEEE Trans. Nucl. Sci. 50, 635-652 (2003). 0018-9499
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 635-652
    • Beezhold, W.1    Beutler, D.E.2
  • 19
    • 0025762578 scopus 로고
    • Automated data collection and analysis system for MOSFET radiation detectors
    • 0094-2405 10.1118/1.596731
    • D. J. Gladstone and L. M. Chin, " Automated data collection and analysis system for MOSFET radiation detectors., " Med. Phys. 0094-2405 10.1118/1.596731 18, 542-548 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 542-548
    • Gladstone, D.J.1    Chin, L.M.2
  • 20
    • 67649723937 scopus 로고
    • The relationship between Co and 10 keV X-ray damage in MOS devices
    • 0018-9499
    • J. M. Benedetto and H. E. Boesch, " The relationship between Co and 10 keV X-ray damage in MOS devices., " IEEE Trans. Nucl. Sci. 33, 1318-1323 (1986). 0018-9499
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , pp. 1318-1323
    • Benedetto, J.M.1    Boesch, H.E.2
  • 21
    • 0038447119 scopus 로고    scopus 로고
    • Radiation effects and hardening of MOS technology: Devices and circuits
    • 0018-9499 10.1109/TNS.2003.812928
    • H. L. Hughes and J. M. Benedetto, " Radiation effects and hardening of MOS technology: Devices and circuits., " IEEE Trans. Nucl. Sci. 0018-9499 10.1109/TNS.2003.812928 50, 500-521 (2003).
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 500-521
    • Hughes, H.L.1    Benedetto, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.