메뉴 건너뛰기




Volumn 105, Issue 6, 2007, Pages 1585-1591

Programming pressure support ventilation in pediatric patients in ambulatory surgery with a laryngeal mask airway

Author keywords

[No Author keywords available]

Indexed keywords

FENTANYL;

EID: 36549011332     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ane.0000287674.64086.f1     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 0036261801 scopus 로고    scopus 로고
    • Pressure support compared with controlled mechanical ventilation in experimental lung injury
    • Dembinski R, Max M, Bensberg R, Rossaint R, Kuhlen R. Pressure support compared with controlled mechanical ventilation in experimental lung injury. Anesth Analg 2002;94:1570-6
    • (2002) Anesth Analg , vol.94 , pp. 1570-1576
    • Dembinski, R.1    Max, M.2    Bensberg, R.3    Rossaint, R.4    Kuhlen, R.5
  • 4
    • 0035346690 scopus 로고    scopus 로고
    • Differences in respiratory parameters during continuous positive airway pressure and pressure support ventilation in infants and children
    • Hoshi K, Ejima Y, Hasegawa R, Saitoh K, Satoh S, Matsukawa S. Differences in respiratory parameters during continuous positive airway pressure and pressure support ventilation in infants and children. Tohoku J Exp Med 2001;194:45-54
    • (2001) Tohoku J Exp Med , vol.194 , pp. 45-54
    • Hoshi, K.1    Ejima, Y.2    Hasegawa, R.3    Saitoh, K.4    Satoh, S.5    Matsukawa, S.6
  • 5
    • 0030770909 scopus 로고    scopus 로고
    • Pressure support ventilation augments spontaneous breathing with improved thoracoabdominal synchrony in neonates with congenital heart disease
    • Tokioka H, Nagano O, Ohta Y, Hirakawa M. Pressure support ventilation augments spontaneous breathing with improved thoracoabdominal synchrony in neonates with congenital heart disease. Anesth Analg 1997;85:789-93
    • (1997) Anesth Analg , vol.85 , pp. 789-793
    • Tokioka, H.1    Nagano, O.2    Ohta, Y.3    Hirakawa, M.4
  • 6
    • 0033889194 scopus 로고    scopus 로고
    • Reduction in tracheal lumen due to endotracheal intubation and its calculated clinical significance
    • Bock KR, Silver P, Rom M, Sagy M. Reduction in tracheal lumen due to endotracheal intubation and its calculated clinical significance. Chest 2000;118:468-72
    • (2000) Chest , vol.118 , pp. 468-472
    • Bock, K.R.1    Silver, P.2    Rom, M.3    Sagy, M.4
  • 7
    • 0035161013 scopus 로고    scopus 로고
    • The effect of breath termination criterion on breathing patterns and the work of breathing during pressure support ventilation
    • Tokioka H, Tanaka T, Ishizu T, Fukushima T, Iwaki T, Nakamura Y, Kosogabe Y. The effect of breath termination criterion on breathing patterns and the work of breathing during pressure support ventilation. Anesth Analg 2001;92:161-5
    • (2001) Anesth Analg , vol.92 , pp. 161-165
    • Tokioka, H.1    Tanaka, T.2    Ishizu, T.3    Fukushima, T.4    Iwaki, T.5    Nakamura, Y.6    Kosogabe, Y.7
  • 8
    • 4644310659 scopus 로고    scopus 로고
    • Continuous positive airway pressure versus noninvasive pressure support ventilation to treat atelectasis after cardiac surgery
    • Pasquina P, Merlani P, Granier JM, Ricou B. Continuous positive airway pressure versus noninvasive pressure support ventilation to treat atelectasis after cardiac surgery. Anesth Analg 2004;99:1001-8
    • (2004) Anesth Analg , vol.99 , pp. 1001-1008
    • Pasquina, P.1    Merlani, P.2    Granier, J.M.3    Ricou, B.4
  • 9
    • 0027193717 scopus 로고
    • The effectiveness of pressure support ventilation for mechanical ventilatory support in children
    • Tokioka H, Kinjo M, Hirakawa M. The effectiveness of pressure support ventilation for mechanical ventilatory support in children. Anesthesiology 1993;78:880-4
    • (1993) Anesthesiology , vol.78 , pp. 880-884
    • Tokioka, H.1    Kinjo, M.2    Hirakawa, M.3
  • 10
    • 28844509281 scopus 로고    scopus 로고
    • Use of the ProSeal laryngeal mask airway for pressure-controlled ventilation with and without positive end-expiratory pressure in paediatric patients: A randomized, controlled study
    • Goldmann K, Roettger C, Wulf H. Use of the ProSeal laryngeal mask airway for pressure-controlled ventilation with and without positive end-expiratory pressure in paediatric patients: a randomized, controlled study. Br J Anaesth 2005;95:831-4
    • (2005) Br J Anaesth , vol.95 , pp. 831-834
    • Goldmann, K.1    Roettger, C.2    Wulf, H.3
  • 11
    • 0035209852 scopus 로고    scopus 로고
    • The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children
    • Main E, Castle R, Stocks J, James I, Hatch D. The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children. Intensive Care Med 2001;27:1788-97
    • (2001) Intensive Care Med , vol.27 , pp. 1788-1797
    • Main, E.1    Castle, R.2    Stocks, J.3    James, I.4    Hatch, D.5
  • 12
    • 19444364711 scopus 로고    scopus 로고
    • Pressure support ventilation combined with volume guarantee versus synchronized intermittent mandatory ventilation: A pilot crossover trial in premature infants in their weaning phase
    • Abd El-Moneim ES, Fuerste HO, Krueger M, Elmagd AA, Brandis M, Schulte-Moenting J, Hentschel R. Pressure support ventilation combined with volume guarantee versus synchronized intermittent mandatory ventilation: a pilot crossover trial in premature infants in their weaning phase. Pediatr Crit Care Med 2005;6:286-92
    • (2005) Pediatr Crit Care Med , vol.6 , pp. 286-292
    • Abd El-Moneim, E.S.1    Fuerste, H.O.2    Krueger, M.3    Elmagd, A.A.4    Brandis, M.5    Schulte-Moenting, J.6    Hentschel, R.7
  • 13
    • 0029680666 scopus 로고    scopus 로고
    • Pressure support ventilation increases cardiac output in neonates and infants
    • Gullberg N, Winberg P, Sellden H. Pressure support ventilation increases cardiac output in neonates and infants. Paediatr Anaesth 1996;6:311-15
    • (1996) Paediatr Anaesth , vol.6 , pp. 311-315
    • Gullberg, N.1    Winberg, P.2    Sellden, H.3
  • 14
    • 0034130434 scopus 로고    scopus 로고
    • Pressure support ventilation versus continuous positive airway pressure with the laryngeal mask airway: A randomized crossover study of anesthetized adult patients
    • Brimacombe J, Keller C, Hormann C. Pressure support ventilation versus continuous positive airway pressure with the laryngeal mask airway: a randomized crossover study of anesthetized adult patients. Anesthesiology 2000;92:1621-3
    • (2000) Anesthesiology , vol.92 , pp. 1621-1623
    • Brimacombe, J.1    Keller, C.2    Hormann, C.3
  • 16
    • 0033708735 scopus 로고    scopus 로고
    • Work of breathing during spontaneous ventilation in anesthetized children: A comparative study among the face mask, laryngeal mask airway and endotracheal tube
    • Keidan I, Fine GF, Kagawa T, Schneck FX, Motoyama EK. Work of breathing during spontaneous ventilation in anesthetized children: a comparative study among the face mask, laryngeal mask airway and endotracheal tube. Anesth Analg 2000;91:1381-8
    • (2000) Anesth Analg , vol.91 , pp. 1381-1388
    • Keidan, I.1    Fine, G.F.2    Kagawa, T.3    Schneck, F.X.4    Motoyama, E.K.5
  • 17
    • 12844266081 scopus 로고    scopus 로고
    • Pressure support ventilation versus continuous positive airway pressure ventilation with the ProSeal laryngeal mask airway: A randomized crossover study of anesthetized pediatric patients
    • von Goedecke A, Brimacombe J, Hormann C, Jeske HC, Kleinsasser A, Keller C. Pressure support ventilation versus continuous positive airway pressure ventilation with the ProSeal laryngeal mask airway: a randomized crossover study of anesthetized pediatric patients. Anesth Analg 2005;100:357-60
    • (2005) Anesth Analg , vol.100 , pp. 357-360
    • von Goedecke, A.1    Brimacombe, J.2    Hormann, C.3    Jeske, H.C.4    Kleinsasser, A.5    Keller, C.6
  • 18
    • 33750439453 scopus 로고    scopus 로고
    • Performance characteristics of five new anesthesia ventilators and four intensive care ventilators in pressure-support mode: A comparative bench study
    • Jaber S, Tassaux D, Sebbane M, Pouzeratte Y, Battisti A, Capdevila X, Eledjam JJ, Jolliet P. Performance characteristics of five new anesthesia ventilators and four intensive care ventilators in pressure-support mode: a comparative bench study. Anesthesiology 2006;105:872-3
    • (2006) Anesthesiology , vol.105 , pp. 872-873
    • Jaber, S.1    Tassaux, D.2    Sebbane, M.3    Pouzeratte, Y.4    Battisti, A.5    Capdevila, X.6    Eledjam, J.J.7    Jolliet, P.8
  • 20
    • 0027377991 scopus 로고
    • A novel sensor for routine continuous spirometry of intubated patients
    • Merilainen P, Hanninen H, Tuomaala L. A novel sensor for routine continuous spirometry of intubated patients. J Clin Monit 1993;9:374-80
    • (1993) J Clin Monit , vol.9 , pp. 374-380
    • Merilainen, P.1    Hanninen, H.2    Tuomaala, L.3
  • 21
    • 14944340992 scopus 로고    scopus 로고
    • The ProSeal laryngeal mask airway in children
    • Lopez-Gil M, Brimacombe J. The ProSeal laryngeal mask airway in children. Paediatr Anaesth 2005;15:229-34
    • (2005) Paediatr Anaesth , vol.15 , pp. 229-234
    • Lopez-Gil, M.1    Brimacombe, J.2
  • 24
    • 0031872646 scopus 로고    scopus 로고
    • A comparison of the respiratory effects of sevoflurane and halothane in infants and young children
    • Brown K, Aun C, Stocks J, Jackson E, Mackersie A, Hatch D. A comparison of the respiratory effects of sevoflurane and halothane in infants and young children. Anesthesiology 1998;89:86-92
    • (1998) Anesthesiology , vol.89 , pp. 86-92
    • Brown, K.1    Aun, C.2    Stocks, J.3    Jackson, E.4    Mackersie, A.5    Hatch, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.