메뉴 건너뛰기




Volumn 14, Issue 6, 1998, Pages 425-431

Evaluation of a Pitot type spirometer in helium/oxygen mixtures

Author keywords

Gas density; Helium; Measurement; Oxygen; Tidal volume; Venturimeter

Indexed keywords

BINARY MIXTURES; DENSITY MEASUREMENT (SPECIFIC GRAVITY); HELIUM; MATHEMATICAL MODELS; OXYGEN; REGRESSION ANALYSIS; VOLUME MEASUREMENT;

EID: 0032147885     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009978816071     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0000482902 scopus 로고
    • Use of helium as a new therapeutic gas
    • Barach AL. Use of helium as a new therapeutic gas. Proc Soc Biol Med 1934; 32 (Dec): 462-464
    • (1934) Proc Soc Biol Med , vol.32 , Issue.DEC , pp. 462-464
    • Barach, A.L.1
  • 2
    • 0028948922 scopus 로고
    • Heliox therapy in acute severe asthma
    • See also Editorial Comment by Madison IM,Twin RS, 597-598
    • Kass JE, Castriotta RJ. Heliox therapy in acute severe asthma. Chest 1995; 107: 757-760. See also Editorial Comment by Madison IM,Twin RS, 597-598
    • (1995) Chest , vol.107 , pp. 757-760
    • Kass, J.E.1    Castriotta, R.J.2
  • 3
    • 0028795425 scopus 로고
    • Heliox improves pulsus paradoxus and peak expiratory flow in nonintubated patients with severe asthma
    • Feb
    • Manthous CA, Hall JB, Caputo MA et al. Heliox improves pulsus paradoxus and peak expiratory flow in nonintubated patients with severe asthma. Am J Respir Crit Care Med 1995 (Feb); 151 (2 Pt 1): 310-314
    • (1995) Am J Respir Crit Care Med , vol.151 , Issue.2 PART 1 , pp. 310-314
    • Manthous, C.A.1    Hall, J.B.2    Caputo, M.A.3
  • 4
    • 0025130061 scopus 로고
    • Helium-oxygen mixtures in intubated patients with status asthmaticus and respiratory acidosis
    • Sep
    • Gluck EH, Onorato DJ, Castriotta R. Helium-oxygen mixtures in intubated patients with status asthmaticus and respiratory acidosis. Chest 1990 (Sep); 98 (3): 693698
    • (1990) Chest , vol.98 , Issue.3 , pp. 693698
    • Gluck, E.H.1    Onorato, D.J.2    Castriotta, R.3
  • 5
    • 0029968004 scopus 로고    scopus 로고
    • Heli-NO: Enhanced gas exchange with nitric oxide in helium
    • Petros AJ, Tulloh RMR, Wheatley E. Heli-NO: Enhanced gas exchange with nitric oxide in helium. Anesth Analg 1996; 83: 888-889 (Letter)
    • (1996) Anesth Analg , vol.83 , pp. 888-889
    • Petros, A.J.1    Tulloh, R.M.R.2    Wheatley, E.3
  • 6
    • 0023444447 scopus 로고
    • A modified Pitot tube for the accurate measurement of tidal volume in children
    • Nov
    • Wolf AR, Volgyesi GA. A modified Pitot tube for the accurate measurement of tidal volume in children. Anesthesiology 1987 (Nov); 67 (5): 775-778
    • (1987) Anesthesiology , vol.67 , Issue.5 , pp. 775-778
    • Wolf, A.R.1    Volgyesi, G.A.2
  • 7
    • 0028577331 scopus 로고
    • Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise
    • Porszasz J, Barstow TJ, Wasserman K. Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise. J Appl Physiol 1994; 77 (6): 2659-2665
    • (1994) J Appl Physiol , vol.77 , Issue.6 , pp. 2659-2665
    • Porszasz, J.1    Barstow, T.J.2    Wasserman, K.3
  • 8
    • 0027377991 scopus 로고
    • A novel sensor for routine continuous spirometry of intubated patients
    • Meriläinen P, Hänninen H, Tuomaala L. A novel sensor for routine continuous spirometry of intubated patients. J Clin Monit 1993; 9: 374-380
    • (1993) J Clin Monit , vol.9 , pp. 374-380
    • Meriläinen, P.1    Hänninen, H.2    Tuomaala, L.3
  • 10
    • 0016915232 scopus 로고
    • Viskositäts- Und Dichteschwankungen von natürlichen Atemgasen und von Helium-SauerstofF-StickstofF-Gemischen in Abhängigkeit von Temperatur und Gaszusammensetzung
    • Prestele K, Franetzki M, Meerlender G. Viskositäts- und Dichteschwankungen von natürlichen Atemgasen und von Helium-SauerstofF-StickstofF-Gemischen in Abhängigkeit von Temperatur und Gaszusammensetzung. Respiration 1976; 33:150-162
    • (1976) Respiration , vol.33 , pp. 150-162
    • Prestele, K.1    Franetzki, M.2    Meerlender, G.3
  • 11
    • 0019957179 scopus 로고
    • Measurement of gas viscosity with a Fleisch pneumotachograph
    • Johns DP, Preto JJ, Streeton JA. Measurement of gas viscosity with a Fleisch pneumotachograph. J Appl Physiol 1982; 53 (1): 290-293
    • (1982) J Appl Physiol , vol.53 , Issue.1 , pp. 290-293
    • Johns, D.P.1    Preto, J.J.2    Streeton, J.A.3
  • 12
    • 44349129408 scopus 로고
    • The theory and applications of the exchange of inert gas at the lungs and the tissues
    • Kety SS. The theory and applications of the exchange of inert gas at the lungs and the tissues. Pharmacol Rev 1951; 3: 1-41
    • (1951) Pharmacol Rev , vol.3 , pp. 1-41
    • Kety, S.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.