-
1
-
-
0000482902
-
Use of helium as a new therapeutic gas
-
Barach AL. Use of helium as a new therapeutic gas. Proc Soc Biol Med 1934; 32 (Dec): 462-464
-
(1934)
Proc Soc Biol Med
, vol.32
, Issue.DEC
, pp. 462-464
-
-
Barach, A.L.1
-
2
-
-
0028948922
-
Heliox therapy in acute severe asthma
-
See also Editorial Comment by Madison IM,Twin RS, 597-598
-
Kass JE, Castriotta RJ. Heliox therapy in acute severe asthma. Chest 1995; 107: 757-760. See also Editorial Comment by Madison IM,Twin RS, 597-598
-
(1995)
Chest
, vol.107
, pp. 757-760
-
-
Kass, J.E.1
Castriotta, R.J.2
-
3
-
-
0028795425
-
Heliox improves pulsus paradoxus and peak expiratory flow in nonintubated patients with severe asthma
-
Feb
-
Manthous CA, Hall JB, Caputo MA et al. Heliox improves pulsus paradoxus and peak expiratory flow in nonintubated patients with severe asthma. Am J Respir Crit Care Med 1995 (Feb); 151 (2 Pt 1): 310-314
-
(1995)
Am J Respir Crit Care Med
, vol.151
, Issue.2 PART 1
, pp. 310-314
-
-
Manthous, C.A.1
Hall, J.B.2
Caputo, M.A.3
-
4
-
-
0025130061
-
Helium-oxygen mixtures in intubated patients with status asthmaticus and respiratory acidosis
-
Sep
-
Gluck EH, Onorato DJ, Castriotta R. Helium-oxygen mixtures in intubated patients with status asthmaticus and respiratory acidosis. Chest 1990 (Sep); 98 (3): 693698
-
(1990)
Chest
, vol.98
, Issue.3
, pp. 693698
-
-
Gluck, E.H.1
Onorato, D.J.2
Castriotta, R.3
-
5
-
-
0029968004
-
Heli-NO: Enhanced gas exchange with nitric oxide in helium
-
Petros AJ, Tulloh RMR, Wheatley E. Heli-NO: Enhanced gas exchange with nitric oxide in helium. Anesth Analg 1996; 83: 888-889 (Letter)
-
(1996)
Anesth Analg
, vol.83
, pp. 888-889
-
-
Petros, A.J.1
Tulloh, R.M.R.2
Wheatley, E.3
-
6
-
-
0023444447
-
A modified Pitot tube for the accurate measurement of tidal volume in children
-
Nov
-
Wolf AR, Volgyesi GA. A modified Pitot tube for the accurate measurement of tidal volume in children. Anesthesiology 1987 (Nov); 67 (5): 775-778
-
(1987)
Anesthesiology
, vol.67
, Issue.5
, pp. 775-778
-
-
Wolf, A.R.1
Volgyesi, G.A.2
-
7
-
-
0028577331
-
Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise
-
Porszasz J, Barstow TJ, Wasserman K. Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise. J Appl Physiol 1994; 77 (6): 2659-2665
-
(1994)
J Appl Physiol
, vol.77
, Issue.6
, pp. 2659-2665
-
-
Porszasz, J.1
Barstow, T.J.2
Wasserman, K.3
-
8
-
-
0027377991
-
A novel sensor for routine continuous spirometry of intubated patients
-
Meriläinen P, Hänninen H, Tuomaala L. A novel sensor for routine continuous spirometry of intubated patients. J Clin Monit 1993; 9: 374-380
-
(1993)
J Clin Monit
, vol.9
, pp. 374-380
-
-
Meriläinen, P.1
Hänninen, H.2
Tuomaala, L.3
-
10
-
-
0016915232
-
Viskositäts- Und Dichteschwankungen von natürlichen Atemgasen und von Helium-SauerstofF-StickstofF-Gemischen in Abhängigkeit von Temperatur und Gaszusammensetzung
-
Prestele K, Franetzki M, Meerlender G. Viskositäts- und Dichteschwankungen von natürlichen Atemgasen und von Helium-SauerstofF-StickstofF-Gemischen in Abhängigkeit von Temperatur und Gaszusammensetzung. Respiration 1976; 33:150-162
-
(1976)
Respiration
, vol.33
, pp. 150-162
-
-
Prestele, K.1
Franetzki, M.2
Meerlender, G.3
-
11
-
-
0019957179
-
Measurement of gas viscosity with a Fleisch pneumotachograph
-
Johns DP, Preto JJ, Streeton JA. Measurement of gas viscosity with a Fleisch pneumotachograph. J Appl Physiol 1982; 53 (1): 290-293
-
(1982)
J Appl Physiol
, vol.53
, Issue.1
, pp. 290-293
-
-
Johns, D.P.1
Preto, J.J.2
Streeton, J.A.3
-
12
-
-
44349129408
-
The theory and applications of the exchange of inert gas at the lungs and the tissues
-
Kety SS. The theory and applications of the exchange of inert gas at the lungs and the tissues. Pharmacol Rev 1951; 3: 1-41
-
(1951)
Pharmacol Rev
, vol.3
, pp. 1-41
-
-
Kety, S.S.1
|