-
2
-
-
0034803312
-
Phase transformation of a zirconia ceramic head after total hip arthroplasty
-
Haraguchi K, Sugano N, Nishii T, Miki H, Oka K, Yoshikawa H. Phase transformation of a zirconia ceramic head after total hip arthroplasty. J Bone Joint Surg Br 2001;83:996-1000.
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 996-1000
-
-
Haraguchi, K.1
Sugano, N.2
Nishii, T.3
Miki, H.4
Oka, K.5
Yoshikawa, H.6
-
3
-
-
0008291401
-
Friction and wear characteristics of sliding pairs of bioceramics and polyethylene: Influence of aging on tribological behaviour of tetragonal zirconia polycrystals
-
Murakami T, Ohtsuki N. Friction and wear characteristics of sliding pairs of bioceramics and polyethylene: Influence of aging on tribological behaviour of tetragonal zirconia polycrystals. Bioceramics 1992;5:365-372.
-
(1992)
Bioceramics
, vol.5
, pp. 365-372
-
-
Murakami, T.1
Ohtsuki, N.2
-
5
-
-
0013510565
-
Alumina vs. zirconium oxide: A comparative wear test
-
Sudanese A, Toni A, Cattaneo GL, Ciaroni D, Greggi T, Dallari D, Galli G, Giunti A. Alumina vs. zirconium oxide: A comparative wear test. In Bioceramics: Proceedings of First International Bioceramic Symposium; 1988. pp 237-240.
-
(1988)
Bioceramics: Proceedings of First International Bioceramic Symposium
, pp. 237-240
-
-
Sudanese, A.1
Toni, A.2
Cattaneo, G.L.3
Ciaroni, D.4
Greggi, T.5
Dallari, D.6
Galli, G.7
Giunti, A.8
-
6
-
-
0030298085
-
Wear characteristics of sliding pairs of zirconia (Y-TZP) for endoprostheses
-
Willmann G, Fruh HJ, Pfaff HG. Wear characteristics of sliding pairs of zirconia (Y-TZP) for endoprostheses. Biomaterials 1996;17:2157-2162.
-
(1996)
Biomaterials
, vol.17
, pp. 2157-2162
-
-
Willmann, G.1
Fruh, H.J.2
Pfaff, H.G.3
-
7
-
-
0041419860
-
Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
-
Hasegawa M, Sudo A, Hirata H, Uchida A. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 2003;18:658-661.
-
(2003)
J Arthroplasty
, vol.18
, pp. 658-661
-
-
Hasegawa, M.1
Sudo, A.2
Hirata, H.3
Uchida, A.4
-
8
-
-
0037247039
-
Retrieval of ceramic wear couples in total hip arthroplasty
-
Willmann G, Schikora N, Pitto RP. Retrieval of ceramic wear couples in total hip arthroplasty. Bioceramics 15 2003;240: 813-815.
-
(2003)
Bioceramics
, vol.15
, Issue.240
, pp. 813-815
-
-
Willmann, G.1
Schikora, N.2
Pitto, R.P.3
-
9
-
-
0035226418
-
-
Smith RL, Unsworth A. An in vitro wear study of alumina-alumina total hip prostheses. Proc Inst Mech Eng 2001;215: 443-446.
-
Smith RL, Unsworth A. An in vitro wear study of alumina-alumina total hip prostheses. Proc Inst Mech Eng 2001;215: 443-446.
-
-
-
-
10
-
-
0033252313
-
A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator
-
Smith SL, Unsworth A. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Proc Inst Mech Eng [H] 1999;213:475-483.
-
(1999)
Proc Inst Mech Eng [H]
, vol.213
, pp. 475-483
-
-
Smith, S.L.1
Unsworth, A.2
-
11
-
-
0141535277
-
Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. J Arthroplasty 2003;18:726-734.
-
(2003)
J Arthroplasty
, vol.18
, pp. 726-734
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
12
-
-
0035680629
-
Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
-
Stewart T, Tipper J, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001;12:1053-1056.
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.2
Streicher, R.3
Ingham, E.4
Fisher, J.5
-
13
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Nevelos J, Ingham E, Doyle C, Streicher R, Nevelos A, Walter W, Fisher J. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 2000;15: 793-795.
-
(2000)
J Arthroplasty
, vol.15
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
Fisher, J.7
-
14
-
-
2442507670
-
Stripe wear rates in alumina THR - Comparison of microseparation simulator study with retrieved implants
-
Manaka M, Clarke IC, Yamamoto K, Shishido T, Gustafson A, Imakiire A. Stripe wear rates in alumina THR - Comparison of microseparation simulator study with retrieved implants. J Biomed Mater Res B Appl Biomater 2004;69:149-157.
-
(2004)
J Biomed Mater Res B Appl Biomater
, vol.69
, pp. 149-157
-
-
Manaka, M.1
Clarke, I.C.2
Yamamoto, K.3
Shishido, T.4
Gustafson, A.5
Imakiire, A.6
-
15
-
-
0742305043
-
Application of a new in situ 3D laser scanner to study the scale effect on the rock joint surface roughness
-
Fardin N, Feng Q, Stephansson O. Application of a new in situ 3D laser scanner to study the scale effect on the rock joint surface roughness. Int J Rock Mech Min Sci 2004;41: 329-335.
-
(2004)
Int J Rock Mech Min Sci
, vol.41
, pp. 329-335
-
-
Fardin, N.1
Feng, Q.2
Stephansson, O.3
-
16
-
-
0242551668
-
3D acquisition and quantitative measurements of anatomical parts by optical scanning and image reconstruction from unorganized range data
-
Tognola G, Parazzini M, Ravazzani P, Grandori F, Svelto C. 3D acquisition and quantitative measurements of anatomical parts by optical scanning and image reconstruction from unorganized range data. IEEE Trans Instrum Meas 2003;52:1665-1673.
-
(2003)
IEEE Trans Instrum Meas
, vol.52
, pp. 1665-1673
-
-
Tognola, G.1
Parazzini, M.2
Ravazzani, P.3
Grandori, F.4
Svelto, C.5
-
17
-
-
0036819842
-
Three-dimensional modelling of statues: The Minerva of Arezzo
-
Fontana R, Greco M, Materazzi M, Pampaloni E, Pezzati L, Rocchini C, Scopigno R. Three-dimensional modelling of statues: The Minerva of Arezzo. J Cult Heritage 2002;3:325-331.
-
(2002)
J Cult Heritage
, vol.3
, pp. 325-331
-
-
Fontana, R.1
Greco, M.2
Materazzi, M.3
Pampaloni, E.4
Pezzati, L.5
Rocchini, C.6
Scopigno, R.7
-
18
-
-
1642443424
-
-
Dey TK, Goswami S. Tight cocone: A water-tight surface reconstructor. J Comput Inf Sci Eng 2003;4:302-307.
-
Dey TK, Goswami S. Tight cocone: A water-tight surface reconstructor. J Comput Inf Sci Eng 2003;4:302-307.
-
-
-
-
20
-
-
0042476688
-
Validation of acetabular cup wear volume based on direct and two-dimensional measurements: Hip simulator analysis
-
Mizoue T, Yamamoto K, Masaoka T, Imakiire A, Akagi M, Clarke I. Validation of acetabular cup wear volume based on direct and two-dimensional measurements: Hip simulator analysis. J Orthop Sci 2003;8:491-499.
-
(2003)
J Orthop Sci
, vol.8
, pp. 491-499
-
-
Mizoue, T.1
Yamamoto, K.2
Masaoka, T.3
Imakiire, A.4
Akagi, M.5
Clarke, I.6
-
21
-
-
0036316748
-
Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
-
Bragdon CR, Malchau H, Yuan X, Perinchief R, Karrholm J, Borlin N, Estok D, Harris WH. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res 2002;20:688-695.
-
(2002)
J Orthop Res
, vol.20
, pp. 688-695
-
-
Bragdon, C.R.1
Malchau, H.2
Yuan, X.3
Perinchief, R.4
Karrholm, J.5
Borlin, N.6
Estok, D.7
Harris, W.H.8
-
22
-
-
0037241660
-
Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation
-
Williams S, Butterfield M, Stewart T, Ingham E, Stone M, Fisher J. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Proc Inst Mech Eng [H] 2003;217:147-153.
-
(2003)
Proc Inst Mech Eng [H]
, vol.217
, pp. 147-153
-
-
Williams, S.1
Butterfield, M.2
Stewart, T.3
Ingham, E.4
Stone, M.5
Fisher, J.6
-
23
-
-
0037333117
-
Retrieval study of uncemented metal-metal hip prosthesis revised for early loosening
-
Reinisch G, Judmann KP, Lhotka C, Lintner F, Zweymuller KA. Retrieval study of uncemented metal-metal hip prosthesis revised for early loosening. Biomaterials 2003;24:1081-1091.
-
(2003)
Biomaterials
, vol.24
, pp. 1081-1091
-
-
Reinisch, G.1
Judmann, K.P.2
Lhotka, C.3
Lintner, F.4
Zweymuller, K.A.5
-
24
-
-
0034953264
-
Quantitative evaluation of the prosthetic head damage induced by microscopic third-body particles in total hip replacement
-
Raimondi MT, Vena P, Pietrabissa R. Quantitative evaluation of the prosthetic head damage induced by microscopic third-body particles in total hip replacement. J Biomed Mater Res 2001;58:436-448.
-
(2001)
J Biomed Mater Res
, vol.58
, pp. 436-448
-
-
Raimondi, M.T.1
Vena, P.2
Pietrabissa, R.3
-
25
-
-
0032818125
-
The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacements
-
Elfick APD, Hall RM, Pinder IM, Unsworth A. The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacements. Appl Biomater 1999;48:712-718.
-
(1999)
Appl Biomater
, vol.48
, pp. 712-718
-
-
Elfick, A.P.D.1
Hall, R.M.2
Pinder, I.M.3
Unsworth, A.4
-
26
-
-
0035482023
-
Morphological assessment of in vivo wear of orthopaedic implants using multiscalar wavelets
-
Jiang XQ, Blunt L. Morphological assessment of in vivo wear of orthopaedic implants using multiscalar wavelets. Wear 2001;250: 217-221.
-
(2001)
Wear
, vol.250
, pp. 217-221
-
-
Jiang, X.Q.1
Blunt, L.2
-
27
-
-
0031008419
-
Analysis of particles in acetabular components from patients with osteolysis
-
Bloebaum RD, Zou L, Bachus KN, Shea KG, Hofmann AA, Dunn HK. Analysis of particles in acetabular components from patients with osteolysis. Clin Orthop Relat Res 1997;338: 109-118.
-
(1997)
Clin Orthop Relat Res
, vol.338
, pp. 109-118
-
-
Bloebaum, R.D.1
Zou, L.2
Bachus, K.N.3
Shea, K.G.4
Hofmann, A.A.5
Dunn, H.K.6
-
28
-
-
0034121393
-
Elemental and morphological identification of third-body particulate and calcium stearate inclusions in polyethylene components
-
Willie BM, Shea JE, Bloebaum RD, Hofmann AA. Elemental and morphological identification of third-body particulate and calcium stearate inclusions in polyethylene components. J Biomed Mater Res 2000;53:137-142.
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 137-142
-
-
Willie, B.M.1
Shea, J.E.2
Bloebaum, R.D.3
Hofmann, A.A.4
-
29
-
-
0031816246
-
In vitro, in vivo, and tissue retrieval studies on particulate debris
-
Goodman SB, Lind M, Song Y, Smith RL. In vitro, in vivo, and tissue retrieval studies on particulate debris. Clin Orthop 1998;352:25-34.
-
(1998)
Clin Orthop
, vol.352
, pp. 25-34
-
-
Goodman, S.B.1
Lind, M.2
Song, Y.3
Smith, R.L.4
-
30
-
-
0029120016
-
Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
-
Maloney WJ, Smith RL. Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris. J Bone Joint Surg Am 1995;77:1448-1461.
-
(1995)
J Bone Joint Surg Am
, vol.77
, pp. 1448-1461
-
-
Maloney, W.J.1
Smith, R.L.2
-
31
-
-
0027770802
-
Histology of porous-coated acetabular components - 25 Cementless cups retrieved after arthroplasty
-
Sumner DR, Jasty M, Jacobs JJ, Urban RM, Bragdon CR, Harris WH, Galante JO. Histology of porous-coated acetabular components - 25 Cementless cups retrieved after arthroplasty. Acta Orthop Scand 1993;64:619-626.
-
(1993)
Acta Orthop Scand
, vol.64
, pp. 619-626
-
-
Sumner, D.R.1
Jasty, M.2
Jacobs, J.J.3
Urban, R.M.4
Bragdon, C.R.5
Harris, W.H.6
Galante, J.O.7
-
32
-
-
0028076113
-
Etiology of osteolysis around porous-coated cementless total hip arthoplasties
-
Jasty M, Bragdon C, Jiranek W, Chandler H, Maloney W, Harris WH. Etiology of osteolysis around porous-coated cementless total hip arthoplasties. Clin Orthop 1994;308:111-126.
-
(1994)
Clin Orthop
, vol.308
, pp. 111-126
-
-
Jasty, M.1
Bragdon, C.2
Jiranek, W.3
Chandler, H.4
Maloney, W.5
Harris, W.H.6
-
33
-
-
0027296132
-
Particulate metallic debris in cemented total hip arthroplasty
-
Salvati EA, Betts F, Doty SB. Particulate metallic debris in cemented total hip arthroplasty. Clin Orthop 1993;293:160-173.
-
(1993)
Clin Orthop
, vol.293
, pp. 160-173
-
-
Salvati, E.A.1
Betts, F.2
Doty, S.B.3
-
34
-
-
0027426230
-
The response to particulate debris
-
Howie AW, Haynes DR, Rogers SD, McGee MA, Pearcey MJ. The response to particulate debris. Orthop Clin North Am 1993; 24:571-581.
-
(1993)
Orthop Clin North Am
, vol.24
, pp. 571-581
-
-
Howie, A.W.1
Haynes, D.R.2
Rogers, S.D.3
McGee, M.A.4
Pearcey, M.J.5
-
35
-
-
0031105323
-
Polyethylene wear in total hip and knee arthoplasties
-
Lewis G. Polyethylene wear in total hip and knee arthoplasties. J Biomed Mater Res 1997;38:55-75.
-
(1997)
J Biomed Mater Res
, vol.38
, pp. 55-75
-
-
Lewis, G.1
-
36
-
-
0028836831
-
The origin of submicron polyethylene wear debris in total hip arthroplasty
-
McKellop HA, Campbell P, Park SH, Schmalzried TP, Grigoris P, Amstutz HC, Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop 1995;311:3-20.
-
(1995)
Clin Orthop
, vol.311
, pp. 3-20
-
-
McKellop, H.A.1
Campbell, P.2
Park, S.H.3
Schmalzried, T.P.4
Grigoris, P.5
Amstutz, H.C.6
Sarmiento, A.7
-
37
-
-
0031686833
-
Commentary: The multifactorial nature of polyethylene wear in vivo
-
Schmalzried TP, Dorey FJ, McKellop H. Commentary: The multifactorial nature of polyethylene wear in vivo. J Bone Joint Surg Am 1998;80:1234-1243
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 1234-1243
-
-
Schmalzried, T.P.1
Dorey, F.J.2
McKellop, H.3
-
39
-
-
19944371380
-
The effect of counterface roughness on the wear of UHMWPE for rectangular wear paths
-
Turell ME, Friedlaender GE, Wang A, Thornhill TS, Bellare A. The effect of counterface roughness on the wear of UHMWPE for rectangular wear paths. Wear 2005;259:984-991.
-
(2005)
Wear
, vol.259
, pp. 984-991
-
-
Turell, M.E.1
Friedlaender, G.E.2
Wang, A.3
Thornhill, T.S.4
Bellare, A.5
-
40
-
-
0031686498
-
Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups
-
Wang A, Polineni VK, Stark C, Dumbleton JH. Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups. J Arthroplasty 1998;13: 615-620.
-
(1998)
J Arthroplasty
, vol.13
, pp. 615-620
-
-
Wang, A.1
Polineni, V.K.2
Stark, C.3
Dumbleton, J.H.4
-
41
-
-
0032924283
-
Analysis of prosthetic femoral heads retrieved at autopsy
-
Sychterz CJ, Engh CA, Swope SW, McNulty DE, Engh CA. Analysis of prosthetic femoral heads retrieved at autopsy. Clin Orthop 1999;358:223-234.
-
(1999)
Clin Orthop
, vol.358
, pp. 223-234
-
-
Sychterz, C.J.1
Engh, C.A.2
Swope, S.W.3
McNulty, D.E.4
Engh, C.A.5
-
42
-
-
0029421937
-
The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene
-
Fisher J, Firkins P, Reeves E, Hailey J, Isaac G. The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene. Proc Inst Mech Eng [H] 1995;209: 263-264.
-
(1995)
Proc Inst Mech Eng [H]
, vol.209
, pp. 263-264
-
-
Fisher, J.1
Firkins, P.2
Reeves, E.3
Hailey, J.4
Isaac, G.5
-
43
-
-
0348136065
-
Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond
-
Shishido T, Clarke IC, Williams P, Boehler M, Asano T, Shoji H, Masaoka T, Yamamotto K, Imakiire A. Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond. J Biomed Mater Res B Appl Biomater 2003;67: 638-647.
-
(2003)
J Biomed Mater Res B Appl Biomater
, vol.67
, pp. 638-647
-
-
Shishido, T.1
Clarke, I.C.2
Williams, P.3
Boehler, M.4
Asano, T.5
Shoji, H.6
Masaoka, T.7
Yamamotto, K.8
Imakiire, A.9
-
44
-
-
18244382552
-
Assessing the dog as a model for human total hip replacement: Analysis of 38 postmortem-retrieved canine cemented acetabular components
-
Skurla CP, James SP. Assessing the dog as a model for human total hip replacement: Analysis of 38 postmortem-retrieved canine cemented acetabular components. J Biomed Mater Res B Appl Biomater 2005;73:260-270.
-
(2005)
J Biomed Mater Res B Appl Biomater
, vol.73
, pp. 260-270
-
-
Skurla, C.P.1
James, S.P.2
-
45
-
-
0037532344
-
Validation of volumetric and linear wear-measurement in UHMWPE cups - A hip simulator analysis
-
Masaoka T, Clarke IC, Yamamoto K, Tamura J, Williams PA, Good VD, Shoji H, Atsuhiro I. Validation of volumetric and linear wear-measurement in UHMWPE cups - A hip simulator analysis. Wear 2003;254:391-398.
-
(2003)
Wear
, vol.254
, pp. 391-398
-
-
Masaoka, T.1
Clarke, I.C.2
Yamamoto, K.3
Tamura, J.4
Williams, P.A.5
Good, V.D.6
Shoji, H.7
Atsuhiro, I.8
-
46
-
-
0035667566
-
Physicochemical and biomechanical examination of surfaces of retrieved polyethylene heads from total hip prostheses with rotating polyethylene head system
-
Katayama K, Maezawa H, Uesato N, Sasada T. Physicochemical and biomechanical examination of surfaces of retrieved polyethylene heads from total hip prostheses with rotating polyethylene head system. J Orthop Sci 2001;6:503-509.
-
(2001)
J Orthop Sci
, vol.6
, pp. 503-509
-
-
Katayama, K.1
Maezawa, H.2
Uesato, N.3
Sasada, T.4
-
47
-
-
0035053741
-
Influence of polyethylene and femoral head surface quality on wear: A retrieval study
-
Haraguchi K, Sugano N, Nishii T, Sakai T, Yoshikawa H, Ohzono K. Influence of polyethylene and femoral head surface quality on wear: A retrieval study. Int Orthop 2001;25: 29-34.
-
(2001)
Int Orthop
, vol.25
, pp. 29-34
-
-
Haraguchi, K.1
Sugano, N.2
Nishii, T.3
Sakai, T.4
Yoshikawa, H.5
Ohzono, K.6
-
48
-
-
0035280295
-
A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
-
Wang A. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear 2001;248: 38-47.
-
(2001)
Wear
, vol.248
, pp. 38-47
-
-
Wang, A.1
-
49
-
-
0035482516
-
Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator
-
Tipper JL, Firkins PJ, Besong AA, Barbour PSM, Nevelos J, Stone MH, Ingham E, Fisher J. Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear 2001;250: 120-128.
-
(2001)
Wear
, vol.250
, pp. 120-128
-
-
Tipper, J.L.1
Firkins, P.J.2
Besong, A.A.3
Barbour, P.S.M.4
Nevelos, J.5
Stone, M.H.6
Ingham, E.7
Fisher, J.8
|