1
-
-
0026605414
-
Mechanism and clinical significance of wear debris-induced osteolysis
-
Amstuz HC, Camphell P, Kossovsky N, Clarke IC: Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop 276:7-18, 1992.
-
(1992)
Clin Orthop
, vol.276
, pp. 7-18
-
-
Amstuz, H.C.1
Camphell, P.2
Kossovsky, N.3
Clarke, I.C.4
-
2
-
-
0028006356
-
An indirect comparison of third-body wear in retrieved hydroxypatite-coated, porous, and cemented femoral components
-
Bauer TW, Taylor SK, Jiaing M, Medemdorp SV: An indirect comparison of third-body wear in retrieved hydroxypatite-coated, porous, and cemented femoral components. Clin Orthop 298:11-18, 1994.
-
(1994)
Clin Orthop
, vol.298
, pp. 11-18
-
-
Bauer, T.W.1
Taylor, S.K.2
Jiaing, M.3
Medemdorp, S.V.4
-
3
-
-
0028121039
-
Complications, with hydroxyapatite particulate separation in total bip replacement
-
Bloehaum RD, Beeks D, Dorr LD, et al: Complications, with hydroxyapatite particulate separation in total bip replacement. Clin Orthop 298: 19-26, 1994.
-
(1994)
Clin Orthop
, vol.298
, pp. 19-26
-
-
Bloehaum, R.D.1
Beeks, D.2
Dorr, L.D.3
-
4
-
-
0027530301
-
Osteolysis from a pressfit hydroxyapatite implant: A case study
-
Bloebaum RD, Dupont JA: Osteolysis from a pressfit hydroxyapatite implant: A case study. J Arthroplasly 8:195-202, 1993.
-
(1993)
J Arthroplasly
, vol.8
, pp. 195-202
-
-
Bloebaum, R.D.1
Dupont, J.A.2
-
5
-
-
0007734491
-
Third-body microscopic particulate in clinically retrieved polyethylene inserts
-
Bloebaum RD, Zou L, Dunn HK, Hofman AA: Third-body microscopic particulate in clinically retrieved polyethylene inserts. Trans Orthop Res Soc 20:776, 1995.
-
(1995)
Trans Orthop Res Soc
, vol.20
, pp. 776
-
-
Bloebaum, R.D.1
Zou, L.2
Dunn, H.K.3
Hofman, A.A.4
-
7
-
-
0009885833
-
Mechanically assited corrosion of modular hip prosthesis components in mixed and similar metal combintions
-
Buckley CA, Gilbert RM, Sumner DR. et al: Mechanically assited corrosion of modular hip prosthesis components in mixed and similar metal combintions. Trans, Soc Biomater 15:58, 1992.
-
(1992)
Trans, Soc Biomater
, vol.15
, pp. 58
-
-
Buckley, C.A.1
Gilbert, R.M.2
Sumner, D.R.3
-
8
-
-
0016505650
-
The histology of loosening between acrylic cement and bone: Proceedings and reports of universities, colleges, councils and associations
-
Charnley J: The histology of loosening between acrylic cement and bone: Proceedings and reports of universities, colleges, councils and associations. J Bone Joint Surg 376:245, 1975.
-
(1975)
J Bone Joint Surg
, vol.376
, pp. 245
-
-
Charnley, J.1
-
9
-
-
0002646338
-
Low Friction Arthroplasty of the Hip
-
New York. Springer
-
Charnley J: Low Friction Arthroplasty of the Hip. Theory and Practice. New York. Springer 330-331, 1979.
-
(1979)
Theory and Practice
, pp. 330-331
-
-
Charnley, J.1
-
10
-
-
0000499524
-
Interface Failure Dynamics: Osteoclastic and Macrophagic Bone Loss
-
Paul JP, Barbenel JC, Courtney JM, Kennedi RM (eds). New York, Adam Hilger
-
Clarke I, Campbell P: Interface Failure Dynamics: Osteoclastic and Macrophagic Bone Loss. In Paul JP, Barbenel JC, Courtney JM, Kennedi RM (eds). 25 Years Progress in Bioengineering. New York, Adam Hilger 104-115, 1989.
-
(1989)
25 Years Progress in Bioengineering
, pp. 104-115
-
-
Clarke, I.1
Campbell, P.2
-
11
-
-
0028054956
-
Wear and corrosion of modular interfaces in total hip replacements
-
Cook SD, Barrack RL, Baffes GC, et al: Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop 298:80-88, 1994.
-
(1994)
Clin Orthop
, vol.298
, pp. 80-88
-
-
Cook, S.D.1
Barrack, R.L.2
Baffes, G.C.3
-
12
-
-
0027155027
-
Torsional resistance and wear of a modular sleeve-stem hip system
-
Cook SD, Mauley MT, Kester MA, Dong NG: Torsional resistance and wear of a modular sleeve-stem hip system. Clin Mater 12:153-158, 1993.
-
(1993)
Clin Mater
, vol.12
, pp. 153-158
-
-
Cook, S.D.1
Mauley, M.T.2
Kester, M.A.3
Dong, N.G.4
-
13
-
-
0025679122
-
Histologic, biochemical and ion analysis of tissue and fluids retrieved during total hip arihroplasty
-
Dorr LD, Bloebaum R, Emmanual J, Meldrum R: Histologic, biochemical and ion analysis of tissue and fluids retrieved during total hip arihroplasty. Clin Orthop 261:82-95, 1990.
-
(1990)
Clin Orthop
, vol.261
, pp. 82-95
-
-
Dorr, L.D.1
Bloebaum, R.2
Emmanual, J.3
Meldrum, R.4
-
14
-
-
0028846588
-
Natural history of bone response to hydroxyapatitecoated hip prostheses implanted in humans
-
Frayssinet P, Hardy D, Hanker JS, Giammara BL: Natural history of bone response to hydroxyapatitecoated hip prostheses implanted in humans. Cells Mater 5:125-138, 1995.
-
(1995)
Cells Mater
, vol.5
, pp. 125-138
-
-
Frayssinet, P.1
Hardy, D.2
Hanker, J.S.3
Giammara, B.L.4
-
15
-
-
0026594536
-
The first 32 years of total hip arthroplasty. One surgeon's perspective
-
Harris WH: The first 32 years of total hip arthroplasty. One surgeon's perspective. Clin Orthop 274:6-11, 1992.
-
(1992)
Clin Orthop
, vol.274
, pp. 6-11
-
-
Harris, W.H.1
-
16
-
-
0028325196
-
Osteolysis and particle disease in hip replacement
-
Harris WH: Osteolysis and particle disease in hip replacement. Acta Orthop Scand 65:113-123, 1994.
-
(1994)
Acta Orthop Scand
, vol.65
, pp. 113-123
-
-
Harris, W.H.1
-
17
-
-
0000858076
-
The role of small polyethylene wear particles in inducing the release of mediators known to stimulate bone resorption
-
Howie D, Rogers S, Haynes D, Pearcy M: The role of small polyethylene wear particles in inducing the release of mediators known to stimulate bone resorption. Trans Orthop Res Soc 19:201-234, 1994.
-
(1994)
Trans Orthop Res Soc
, vol.19
, pp. 201-234
-
-
Howie, D.1
Rogers, S.2
Haynes, D.3
Pearcy, M.4
-
18
-
-
0025325377
-
Resurfacing hip arthroplasty. Classification of loosening and the role of prosthesis wear particles
-
Howie DW, Cornish BL, Vernon-Roberts B: Resurfacing hip arthroplasty. Classification of loosening and the role of prosthesis wear particles. Clin Orthop 255:144-159, 1990.
-
(1990)
Clin Orthop
, vol.255
, pp. 144-159
-
-
Howie, D.W.1
Cornish, B.L.2
Vernon-Roberts, B.3
-
19
-
-
0023677786
-
The synovial response to intraarticular cobalt-chrome wear particles
-
Howie DW, Vernon-Roberts B: The synovial response to intraarticular cobalt-chrome wear particles. Clin Orthop 232:244-254, 1988.
-
(1988)
Clin Orthop
, vol.232
, pp. 244-254
-
-
Howie, D.W.1
Vernon-Roberts, B.2
-
20
-
-
0023860303
-
A rat model of resorption of bone at the cement-bone interlace in the presence ol polyethylene wear panicles
-
Howie DW, Vernon-Roberts B, Oakeshott R, Man-they B: A rat model of resorption of bone at the cement-bone interlace in the presence ol polyethylene wear panicles, J Bone Joint Surg 70A:257-263, 1988.
-
(1988)
J Bone Joint Surg
, vol.70 A
, pp. 257-263
-
-
Howie, D.W.1
Vernon-Roberts, B.2
Oakeshott, R.3
Man-they, B.4
-
23
-
-
0029147350
-
Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement
-
Maloney WJ, Smith RL, Schmalzried TP. et al: Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. J Bone Joint Surg 77A:1301-1310, 1995.
-
(1995)
J Bone Joint Surg
, vol.77 A
, pp. 1301-1310
-
-
Maloney, W.J.1
Smith, R.L.2
Schmalzried, T.P.3
-
24
-
-
0028057541
-
Wear debris. An environmental issue in total joint replacement
-
Manley MT. Serekian P: Wear debris. An environmental issue in total joint replacement. Clin Orthop 298:137-146, 1994.
-
(1994)
Clin Orthop
, vol.298
, pp. 137-146
-
-
Manley, M.T.1
Serekian, P.2
-
25
-
-
0028943652
-
Distinguishing wear and creep in clinically retrieved polyethylene inserts
-
McDonald MD, Bloebaum RD: Distinguishing wear and creep in clinically retrieved polyethylene inserts. J Biomed Mater Res 29:1-7, 1995.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 1-7
-
-
McDonald, M.D.1
Bloebaum, R.D.2
-
26
-
-
0027703603
-
Metal ion concentrations in retrieved polyethylene total hip inserts and implications for artifactually high readings in tissue
-
Meldrum RD, Bloebaum RD, Dorr LD: Metal ion concentrations in retrieved polyethylene total hip inserts and implications for artifactually high readings in tissue. J Biomed Mater Res 27: 1349-1355, 1993.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 1349-1355
-
-
Meldrum, R.D.1
Bloebaum, R.D.2
Dorr, L.D.3
-
27
-
-
0030003674
-
Analysisof lymph nodes for polyethylene particles in patients who have had primary joint replacements
-
Shea KG, Bloebaum RD, Avent JM. et al: Analysisof lymph nodes for polyethylene particles in patients who have had primary joint replacements. J Bone Joint Surg 78A:497-504, 1996.
-
(1996)
J Bone Joint Surg
, vol.78 A
, pp. 497-504
-
-
Shea, K.G.1
Bloebaum, R.D.2
Avent, J.M.3
-
28
-
-
0030087829
-
Inability of energy dispersive x-ray analysis to identify particulate polyethylene
-
Shea KG, Lundeen GA, Bachus KN. et al: Inability of energy dispersive x-ray analysis to identify particulate polyethylene. J Biomed Mater Res 30:175-180, 1996.
-
(1996)
J Biomed Mater Res
, vol.30
, pp. 175-180
-
-
Shea, K.G.1
Lundeen, G.A.2
Bachus, K.N.3
-
29
-
-
0027404161
-
The meaning of graylevels in backscattered electron images of bone
-
Skedros JG, Bloebaum RD, Bachus KN, Boyce TM: The meaning of graylevels in backscattered electron images of bone. J Biomed Mater Res 27:47-56, 1993.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 47-56
-
-
Skedros, J.G.1
Bloebaum, R.D.2
Bachus, K.N.3
Boyce, T.M.4
-
30
-
-
0027398456
-
Influence of mineral content and composition on graylevels in backscattered electron images of bone
-
Skedros JG, Bloebaum RD, Bachus KN, et al: Influence of mineral content and composition on graylevels in backscattered electron images of bone. J Biomed Mater Res 27:57-64, 1993.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 57-64
-
-
Skedros, J.G.1
Bloebaum, R.D.2
Bachus, K.N.3
-
31
-
-
0029027099
-
Effect of polyethylene quality on wear in total knee arthropl;asty
-
Tanner MG, Whiteside LA, White SE: Effect of polyethylene quality on wear in total knee arthropl;asty. Clin Orthop 317:83-88, 1995.
-
(1995)
Clin Orthop
, vol.317
, pp. 83-88
-
-
Tanner, M.G.1
Whiteside, L.A.2
White, S.E.3
-
32
-
-
0017462028
-
Reactions of the articular capsule to wear products of artificial joint prostheses
-
Willert H-G, Semlitsch M: Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 11:157-164, 1997.
-
(1997)
J Biomed Mater Res
, vol.11
, pp. 157-164
-
-
Willert, H.-G.1
Semlitsch, M.2
|