메뉴 건너뛰기




Volumn 48, Issue 5, 1999, Pages 712-718

The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement

Author keywords

Explanted; Surface topography; Total hip arthroplasty; Wear

Indexed keywords

BIOMATERIALS; BONE; FUNCTIONAL ASSESSMENT; JOINTS (ANATOMY); MATHEMATICAL MODELS; SURFACE TOPOGRAPHY; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 0032818125     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(1999)48:5<712::AID-JBM17>3.0.CO;2-R     Document Type: Article
Times cited : (45)

References (31)
  • 1
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total hip replacements
    • Wang A, Sun DC, Stark C, Dumbleton JH. Wear mechanisms of UHMWPE in total hip replacements. Wear 1995;181-183:241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 2
    • 0028129938 scopus 로고
    • Current concepts review: Ultrahigh molecular weight polyethylene
    • Li S, Burstein AH. Current concepts review: ultrahigh molecular weight polyethylene. J Bone Joint Surg 1994;76A:1080-1090.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 1080-1090
    • Li, S.1    Burstein, A.H.2
  • 3
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty: Polyethylene wear debris and the concept of effective joint space
    • Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty: Polyethylene wear debris and the concept of effective joint space. J Bone Joint Surg 1992;74A: 849-863.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 5
    • 0025052402 scopus 로고
    • Macrophages stimulate bone resorption when they phagocytose particles
    • Murray DW, Rushton N. Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg 1990; 728:988-992.
    • (1990) J Bone Joint Surg , vol.728 , pp. 988-992
    • Murray, D.W.1    Rushton, N.2
  • 6
    • 0028448404 scopus 로고
    • Frictional characterisation of explanted charnley hip prostheses
    • Hall RM, Unsworth A, Wroblewski BM, Burgess IC. Frictional characterisation of explanted charnley hip prostheses. Wear 1994;175:159-166.
    • (1994) Wear , vol.175 , pp. 159-166
    • Hall, R.M.1    Unsworth, A.2    Wroblewski, B.M.3    Burgess, I.C.4
  • 8
    • 0000386737 scopus 로고
    • Influence of counterface topography on the wear of UHMWPE under wet or dry conditions
    • Dowson D, Diab M, Gillis B, Atkinson J. Influence of counterface topography on the wear of UHMWPE under wet or dry conditions. Am Chem Soc 1985:171-187.
    • (1985) Am Chem Soc , pp. 171-187
    • Dowson, D.1    Diab, M.2    Gillis, B.3    Atkinson, J.4
  • 9
    • 0022615189 scopus 로고
    • The effect of the surface finish of alumina and stainless steel on the wear rate of UHMWPE
    • Weightman B, Light D. The effect of the surface finish of alumina and stainless steel on the wear rate of UHMWPE. Biomater 1986;7:20-24.
    • (1986) Biomater , vol.7 , pp. 20-24
    • Weightman, B.1    Light, D.2
  • 10
    • 0020100045 scopus 로고
    • Exploratory investigations on the structure dependence of the wear resistance of polyethylene
    • Rose RM, Cimino WR, Ellis E, Crugnola AN. Exploratory investigations on the structure dependence of the wear resistance of polyethylene. Wear 1982;77:89-104.
    • (1982) Wear , vol.77 , pp. 89-104
    • Rose, R.M.1    Cimino, W.R.2    Ellis, E.3    Crugnola, A.N.4
  • 12
    • 0031256146 scopus 로고    scopus 로고
    • The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets
    • Hall RM, Siney P, Unsworth A, Wroblewski BM. The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets. Med Eng Phys 1997;19:711-719.
    • (1997) Med Eng Phys , vol.19 , pp. 711-719
    • Hall, R.M.1    Siney, P.2    Unsworth, A.3    Wroblewski, B.M.4
  • 13
    • 0028671654 scopus 로고
    • Assessment of titanium alloy on polyethylene bearing surfaces in retrieved uncemented total hip replacements
    • Drabu KJ, Michaud RJ, McCullagh PJ J, Brummit K, Smith RA. Assessment of titanium alloy on polyethylene bearing surfaces in retrieved uncemented total hip replacements. Proc Inst Mech Engrs Part H 1994;208:91-95.
    • (1994) Proc Inst Mech Engrs Part H , vol.208 , pp. 91-95
    • Drabu, K.J.1    Michaud, R.J.2    McCullagh, P.J.J.3    Brummit, K.4    Smith, R.A.5
  • 15
    • 0028006356 scopus 로고
    • An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous and cemented femoral components
    • Bauer TW, Taylor SK, Jiang M, Medendorp SV. An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous and cemented femoral components. Clin Ortho Rel Res 1994;298:11-18.
    • (1994) Clin Ortho Rel Res , vol.298 , pp. 11-18
    • Bauer, T.W.1    Taylor, S.K.2    Jiang, M.3    Medendorp, S.V.4
  • 16
    • 0031003077 scopus 로고    scopus 로고
    • Femoral component wear in retrieved hip prostheses
    • Kusaba A, Kuroki Y. Femoral component wear in retrieved hip prostheses. J Bone Joint Surg 1997;79B:331-336.
    • (1997) J Bone Joint Surg , vol.79 B , pp. 331-336
    • Kusaba, A.1    Kuroki, Y.2
  • 17
    • 0027030731 scopus 로고
    • Quality of the surface finish of the head of the femoral component and the wear rate of the socket in long-term results of the charnley low-friction arthroplasty
    • Wroblewski BM, McCullagh PJ, Siney PD. Quality of the surface finish of the head of the femoral component and the wear rate of the socket in long-term results of the charnley low-friction arthroplasty. Proc Inst Mech Engrs Part H 1992; 206:181-183.
    • (1992) Proc Inst Mech Engrs Part H , vol.206 , pp. 181-183
    • Wroblewski, B.M.1    McCullagh, P.J.2    Siney, P.D.3
  • 19
    • 0022108298 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints III: The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors
    • Atkinson JR, Dowson D, Isaac JH, Wroblewski BM. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints III: The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors. Wear 1985;104:225-244.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Isaac, J.H.3    Wroblewski, B.M.4
  • 20
    • 0028534424 scopus 로고
    • Comprehensive study of parameters for characterising three-dimensional surface topography III: Parameters for characterising amplitude and some functional properties
    • Dong WP, Sullivan PJ, Stout KJ. Comprehensive study of parameters for characterising three-dimensional surface topography III: Parameters for characterising amplitude and some functional properties. Wear 1994;178:29-43.
    • (1994) Wear , vol.178 , pp. 29-43
    • Dong, W.P.1    Sullivan, P.J.2    Stout, K.J.3
  • 21
    • 0028382678 scopus 로고
    • Application of 3D topography to bioengineering
    • Stout KJ, Blunt LA. Application of 3D topography to bioengineering. Int J Mach Manufac 1995;35:219-229.
    • (1995) Int J Mach Manufac , vol.35 , pp. 219-229
    • Stout, K.J.1    Blunt, L.A.2
  • 22
    • 0032108310 scopus 로고    scopus 로고
    • Surface topography of retrieved acetabular liners: Proposal of a novel wear mechanism
    • Elfick AP, Hall RM, Pinder IM, Unsworth A. Surface topography of retrieved acetabular liners: proposal of a novel wear mechanism. J Mat SCi Let 17:1085-1088.
    • J Mat Sci Let , vol.17 , pp. 1085-1088
    • Elfick, A.P.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 25
    • 0022108299 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total hip joints I: Charnely prostheses with polytetrafluoroethylene acetabular cups
    • Dowson D, Wallbridge NC. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total hip joints I: Charnely prostheses with polytetrafluoroethylene acetabular cups. Wear 1985;104:203-215.
    • (1985) Wear , vol.104 , pp. 203-215
    • Dowson, D.1    Wallbridge, N.C.2
  • 26
    • 0020317686 scopus 로고
    • The walking activity of patients with artificial joints
    • Wallbridge NC, Dowson D. The walking activity of patients with artificial joints. Eng Med 1982;11:95-96.
    • (1982) Eng Med , vol.11 , pp. 95-96
    • Wallbridge, N.C.1    Dowson, D.2
  • 28
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg 1996;78B:280-285.
    • (1996) J Bone Joint Surg , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 29
    • 0344477135 scopus 로고    scopus 로고
    • Wear of ultra-high molecular weight polyethylene acetabular cups against CoCrMo and zirconia femoral heads in a hip joint simulator measured using gravimetric and volumetric techniques
    • to appear
    • Smith SL, Unsworth A. Wear of ultra-high molecular weight polyethylene acetabular cups against CoCrMo and zirconia femoral heads in a hip joint simulator measured using gravimetric and volumetric techniques. Proc Inst Mech Engrs Part H, to appear.
    • Proc Inst Mech Engrs Part H
    • Smith, S.L.1    Unsworth, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.