Stripe Wear Rates in Alumina THR - Comparison of Microseparation Simulator Study with Retrieved Implants

Author keywords

Alumina; Ceramic; Microseparation; Retrieval; Simulator; THR; Wear

Indexed keywords

ALUMINA; BIOMATERIALS; BIOMEDICAL ENGINEERING; COMPUTER SIMULATION; IMPLANTS (SURGICAL); KINEMATICS; LOADS (FORCES); WEAR OF MATERIALS;

EID: 2442507670     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.20033     Document Type: Article
Times cited : (57)

References (14)
  • 1
    • 0015319816 scopus 로고
    • Arthroplastie totale de hanche par prothese en alumine frittee
    • Boutin P. Arthroplastie totale de hanche par prothese en alumine frittee. Rev Chirol Orthop 1972;58:229-246.
    • (1972) Rev Chirol Orthop , vol.58 , pp. 229-246
    • Boutin, P.1
  • 2
    • 0032881955 scopus 로고    scopus 로고
    • Examination of alumina ceramic components from Mittelmeier total hip arthroplasties
    • Nevelos J, Ingham E, Doyle C, Fisher J, Nevelos AB. Examination of alumina ceramic components from Mittelmeier total hip arthroplasties. J Biomater 1999;20:1833-1840.
    • (1999) J Biomater , vol.20 , pp. 1833-1840
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Fisher, J.4    Nevelos, A.B.5
  • 3
    • 0035114433 scopus 로고    scopus 로고
    • The influence of acetabular cup angle on the wear of BIOLOX Forte alumina ceramic bearing couples in a hip joint simulator
    • Nevelos J, Ingham E, Doyle C, Nevelos AB, Fisher J. The influence of acetabular cup angle on the wear of BIOLOX Forte alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001;12:141-144.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 141-144
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 5
    • 0020252111 scopus 로고
    • Wear of alumina-ceramic hip joint: Some clinical and tribological aspects
    • Plitz W, Hoss HV. Wear of alumina-ceramic hip joint: Some clinical and tribological aspects. Biomaterials 1982;1980:187-196.
    • (1982) Biomaterials , vol.1980 , pp. 187-196
    • Plitz, W.1    Hoss, H.V.2
  • 6
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of alumina-alumina hip joints during simulator testing produces clinically relevant wear rates
    • Nevelos J, Ingham E, Doyle C, Streicher R, Nevelos A, Walters W, Fisher J. Microseparation of alumina-alumina hip joints during simulator testing produces clinically relevant wear rates. J Arthroplasty 2000;15:793-795.
    • (2000) J Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Streicher, R.4    Nevelos, A.5    Walters, W.6    Fisher, J.7
  • 7
    • 0035680629 scopus 로고    scopus 로고
    • Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
    • Stewart T, Tipper J, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001;12: 1053-1056.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 1053-1056
    • Stewart, T.1    Tipper, J.2    Streicher, R.3    Ingham, E.4    Fisher, J.5
  • 9
    • 0026768743 scopus 로고
    • Long-term effects of alumina components in total hip prosthesis
    • Dorlot J. Long-term effects of alumina components in total hip prosthesis. Clin Orthop Relat Res 1992;282:47-52.
    • (1992) Clin Orthop Relat Res , vol.282 , pp. 47-52
    • Dorlot, J.1
  • 14
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G et al. Hip contact forces and gait patterns from routine activities. J Biomech 2001;34:859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.