-
1
-
-
0003028797
-
Animal selections in orthopaedic research
-
An YH, Friedman RJ, editors. Boca Raton, FL: CRC Press
-
An YH, Friedman RJ. Animal selections in orthopaedic research. In: An YH, Friedman RJ, editors. Animal models in orthopaedic research. Boca Raton, FL: CRC Press; 1998. p 39-57.
-
(1998)
Animal Models in Orthopaedic Research
, pp. 39-57
-
-
An, Y.H.1
Friedman, R.J.2
-
2
-
-
0032486508
-
Comparison of human, primate, and canine femora: Implications for biomaterials testing in total hip replacement
-
Kuo TY, Skedros JG, Bloebaum RD. Comparison of human, primate, and canine femora: implications for biomaterials testing in total hip replacement. J Biomed Mater Res 1998;40:475-489.
-
(1998)
J Biomed Mater Res
, vol.40
, pp. 475-489
-
-
Kuo, T.Y.1
Skedros, J.G.2
Bloebaum, R.D.3
-
3
-
-
0027657468
-
Comparison of human and canine external femoral morphologies in the context of total hip replacement
-
Bloebaum RD, Ota DT, Skedros JG, Mantas JP. Comparison of human and canine external femoral morphologies in the context of total hip replacement. J Biomed Mater Res 1993;27:1149-1159.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 1149-1159
-
-
Bloebaum, R.D.1
Ota, D.T.2
Skedros, J.G.3
Mantas, J.P.4
-
5
-
-
0027575120
-
Determination of loading parameters in the canine hip in vivo
-
Page AE, Allan C, Jasty M, Harrigan TP, Bragdon CR, Harris WH. Determination of loading parameters in the canine hip in vivo. J Biomech 1993;26:571-579.
-
(1993)
J Biomech
, vol.26
, pp. 571-579
-
-
Page, A.E.1
Allan, C.2
Jasty, M.3
Harrigan, T.P.4
Bragdon, C.R.5
Harris, W.H.6
-
6
-
-
0023869835
-
Telemetric force measurements across the hip after total hip arthroplasty
-
Davy DT, Kotzar GM, Brown RH, Heiple KG, Goldberg VM, Heiple KG Jr, Berilla J, Burstein AH. Telemetric force measurements across the hip after total hip arthroplasty. J Bone Joint Surg Am 1988;70A:45-50.
-
(1988)
J Bone Joint Surg Am
, vol.70 A
, pp. 45-50
-
-
Davy, D.T.1
Kotzar, G.M.2
Brown, R.H.3
Heiple, K.G.4
Goldberg, V.M.5
Heiple Jr., K.G.6
Berilla, J.7
Burstein, A.H.8
-
7
-
-
0013868551
-
Normal gait of the dog: An electrogoniometric study
-
Adrian MJ, Roy WE, Karpovich PV. Normal gait of the dog: An electrogoniometric study. Am J Vet Res 1966;27:90-95.
-
(1966)
Am J Vet Res
, vol.27
, pp. 90-95
-
-
Adrian, M.J.1
Roy, W.E.2
Karpovich, P.V.3
-
9
-
-
0033610520
-
Longevity of British breeds of dog and its relationships with sex, size, cardiovascular variables and disease
-
Michell, AR. Longevity of British breeds of dog and its relationships with sex, size, cardiovascular variables and disease. Vet Rec 1999;145:625-629.
-
(1999)
Vet Rec
, vol.145
, pp. 625-629
-
-
Michell, A.R.1
-
10
-
-
0002506538
-
Biomechanics of artificial joints: The hip
-
Mow VC, Hayes WC, editors. Philadelphia: Lippincott-Raven
-
Huiskes R, Verdonschot N. Biomechanics of artificial joints: the hip. In: Mow VC, Hayes WC, editors. Basic orthopaedic biomechanics (2nd ed.). Philadelphia: Lippincott-Raven; 1997. p 395-460.
-
(1997)
Basic Orthopaedic Biomechanics (2nd Ed.)
, pp. 395-460
-
-
Huiskes, R.1
Verdonschot, N.2
-
11
-
-
84995132569
-
A clinical study of canine total hip arthroplasty
-
Lewis RH, Jones JP Jr. A clinical study of canine total hip arthroplasty. Vet Surg 1980;9:20-23.
-
(1980)
Vet Surg
, vol.9
, pp. 20-23
-
-
Lewis, R.H.1
Jones Jr., J.P.2
-
12
-
-
84995163147
-
Total hip prosthesis for revision of unsuccessful excision arthroplasty
-
Gofton N, Sumner-Smith G. Total hip prosthesis for revision of unsuccessful excision arthroplasty. Vet Surg 1982;11:134-139.
-
(1982)
Vet Surg
, vol.11
, pp. 134-139
-
-
Gofton, N.1
Sumner-Smith, G.2
-
13
-
-
0021104437
-
A five-year study of 221 total hip replacements in the dog
-
Olmstead ML, Hohn RB, Turner TM. A five-year study of 221 total hip replacements in the dog. J Am Vet Med Assoc 1983; 183:191-194.
-
(1983)
J Am Vet Med Assoc
, vol.183
, pp. 191-194
-
-
Olmstead, M.L.1
Hohn, R.B.2
Turner, T.M.3
-
16
-
-
0001774094
-
A modified technique for canine total hip replacement
-
Paul HA, Bargar WL. A modified technique for canine total hip replacement. J Am Anim Hosp Assoc 1987;23:13-18.
-
(1987)
J Am Anim Hosp Assoc
, vol.23
, pp. 13-18
-
-
Paul, H.A.1
Bargar, W.L.2
-
17
-
-
0028857630
-
The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris
-
Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clin Orthop Relat Res 1995;311:21-39.
-
(1995)
Clin Orthop Relat Res
, vol.311
, pp. 21-39
-
-
Bobyn, J.D.1
Jacobs, J.J.2
Tanzer, M.3
Urban, R.M.4
Aribindi, R.5
Sumner, D.R.6
Turner, T.M.7
Brooks, C.E.8
-
18
-
-
0023415324
-
The effect of proximally and fully porous-coated canine hip stem design on bone modeling
-
Bobyn JD, Pilliar RM, Binnington AG, Szivek JA. The effect of proximally and fully porous-coated canine hip stem design on bone modeling. J Orthop Res 1987;5:393-408.
-
(1987)
J Orthop Res
, vol.5
, pp. 393-408
-
-
Bobyn, J.D.1
Pilliar, R.M.2
Binnington, A.G.3
Szivek, J.A.4
-
19
-
-
0028825376
-
Aseptic loosening in uncemented total hip arthroplasty in a canine model
-
Dowd JE, Schwendeman LJ, Macaulay W, Doyle JS, Shanbhag AS, Wilson S, Herndon JH, Rubash HE. Aseptic loosening in uncemented total hip arthroplasty in a canine model. Clin Orthop Relat Res 1995;319:106-121.
-
(1995)
Clin Orthop Relat Res
, vol.319
, pp. 106-121
-
-
Dowd, J.E.1
Schwendeman, L.J.2
Macaulay, W.3
Doyle, J.S.4
Shanbhag, A.S.5
Wilson, S.6
Herndon, J.H.7
Rubash, H.E.8
-
20
-
-
0028308244
-
A study of micromotion and appositional bone growth to a canine madreporic-surfaced femoral component
-
Finkelstein JA, Anderson GI, Waddell JP, Richards RR, Hearn TC, Schemitsh E. A study of micromotion and appositional bone growth to a canine madreporic-surfaced femoral component. J Arthroplasty 1994;9:317-324.
-
(1994)
J Arthroplasty
, vol.9
, pp. 317-324
-
-
Finkelstein, J.A.1
Anderson, G.I.2
Waddell, J.P.3
Richards, R.R.4
Hearn, T.C.5
Schemitsh, E.6
-
21
-
-
0027362304
-
Functional osseointegration of hydroxyapatite-coated implants in a weight-bearing canine model
-
Maistrelli GL, Mahomed N, Fornasier V, Antonelli L, Li Y, Binnington A. Functional osseointegration of hydroxyapatite-coated implants in a weight-bearing canine model. J Arthroplasty 1993;8:549-554.
-
(1993)
J Arthroplasty
, vol.8
, pp. 549-554
-
-
Maistrelli, G.L.1
Mahomed, N.2
Fornasier, V.3
Antonelli, L.4
Li, Y.5
Binnington, A.6
-
23
-
-
12444277445
-
Comparative peri-implant femoral bone remodeling with isoelastic and hypoelastic noncemented canine hip prostheses
-
Harvey EJ, Bobyn JD, Stackpool GJ, Tanzer M. Comparative peri-implant femoral bone remodeling with isoelastic and hypoelastic noncemented canine hip prostheses. Trans Orthop Res Soc 1997;22:307.
-
(1997)
Trans Orthop Res Soc
, vol.22
, pp. 307
-
-
Harvey, E.J.1
Bobyn, J.D.2
Stackpool, G.J.3
Tanzer, M.4
-
24
-
-
0030222088
-
Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis
-
Walenciak MT, Zimmerman MC, Harten RD, Ricci JL, Stamer DT. Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis. J Biomed Mater Res 1996;31:465-474.
-
(1996)
J Biomed Mater Res
, vol.31
, pp. 465-474
-
-
Walenciak, M.T.1
Zimmerman, M.C.2
Harten, R.D.3
Ricci, J.L.4
Stamer, D.T.5
-
25
-
-
0024954244
-
Biomechanical and histologic investigation of cemented total hip arthroplasties: A study of autopsy-retrieved femurs after in vivo cycling
-
Maloney WJ, Jasty M, Burke DW, O'Connor DO, Zalenski EB, Bragdon C, Harris WH. Biomechanical and histologic investigation of cemented total hip arthroplasties: A study of autopsy-retrieved femurs after in vivo cycling. Clin Orthop Relat Res 1989;249:129-140.
-
(1989)
Clin Orthop Relat Res
, vol.249
, pp. 129-140
-
-
Maloney, W.J.1
Jasty, M.2
Burke, D.W.3
O'Connor, D.O.4
Zalenski, E.B.5
Bragdon, C.6
Harris, W.H.7
-
26
-
-
0030903723
-
Wear of polyethylene acetabular components in total hip arthroplasty: An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
-
Jasty M, Goetz DD, Bragdon CR, Lee KR, Hanson AE, Elder JR, Harris WH. Wear of polyethylene acetabular components in total hip arthroplasty: an analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg Am 1997;79A:349-358.
-
(1997)
J Bone Joint Surg Am
, vol.79 A
, pp. 349-358
-
-
Jasty, M.1
Goetz, D.D.2
Bragdon, C.R.3
Lee, K.R.4
Hanson, A.E.5
Elder, J.R.6
Harris, W.H.7
-
27
-
-
0025784682
-
The initiation of failure in cemented femoral components of hip arthroplasties
-
Jasty M, Maloney WJ, Bragdon CR, O'Connor DO, Haire T, Harris WH. The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg Br 1991;73B: 551-558.
-
(1991)
J Bone Joint Surg Br
, vol.73 B
, pp. 551-558
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
O'Connor, D.O.4
Haire, T.5
Harris, W.H.6
-
28
-
-
0027521055
-
Autopsy studies of the bone-cement interface in well-fixed cemented total hip arthroplasties
-
Schmalzried TP, Maloney WJ, Jasty M, Kwong LM, Harris WH. Autopsy studies of the bone-cement interface in well-fixed cemented total hip arthroplasties. J Arthroplasty 1993;8: 179-188.
-
(1993)
J Arthroplasty
, vol.8
, pp. 179-188
-
-
Schmalzried, T.P.1
Maloney, W.J.2
Jasty, M.3
Kwong, L.M.4
Harris, W.H.5
-
29
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
-
Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O'Connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH. The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy. Clin Orthop Relat Res 1992;274:60-78.
-
(1992)
Clin Orthop Relat Res
, vol.274
, pp. 60-78
-
-
Schmalzried, T.P.1
Kwong, L.M.2
Jasty, M.3
Sedlacek, R.C.4
Haire, T.C.5
O'Connor, D.O.6
Bragdon, C.R.7
Kabo, J.M.8
Malcolm, A.J.9
Harris, W.H.10
-
30
-
-
0031226596
-
Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 Cases in 10 dogs (1991-1995)
-
Edwards MR, Egger EL, Schwarz PD. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995). J Am Vet Med Assoc 1997;211: 580-586.
-
(1997)
J Am Vet Med Assoc
, vol.211
, pp. 580-586
-
-
Edwards, M.R.1
Egger, E.L.2
Schwarz, P.D.3
-
31
-
-
0035041707
-
A comparison of canine and human UHMWPE acetabular component wear
-
Skurla CT, James SP. A comparison of canine and human UHMWPE acetabular component wear. Biomed Sci Instrum 2001;37:245-250.
-
(2001)
Biomed Sci Instrum
, vol.37
, pp. 245-250
-
-
Skurla, C.T.1
James, S.P.2
-
33
-
-
0005074953
-
A new method of volumetric quantification of retrieved polyethylene components
-
Biggs S, Bragdon CR, Sedlacek R, Lee K, Jasty M, Estok D, Harris WH. A new method of volumetric quantification of retrieved polyethylene components. Trans Orthop Res Soc 1996;21:470.
-
(1996)
Trans Orthop Res Soc
, vol.21
, pp. 470
-
-
Biggs, S.1
Bragdon, C.R.2
Sedlacek, R.3
Lee, K.4
Jasty, M.5
Estok, D.6
Harris, W.H.7
-
34
-
-
0033047781
-
Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: Effect of starting resin and forming method
-
James SP, Lee KR, Beauregard GP, Rentfrow ED, McLaughlin JR. Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: effect of starting resin and forming method. J Biomed Mater Res Appl Biomater 1999;48:374-384.
-
(1999)
J Biomed Mater Res Appl Biomater
, vol.48
, pp. 374-384
-
-
James, S.P.1
Lee, K.R.2
Beauregard, G.P.3
Rentfrow, E.D.4
McLaughlin, J.R.5
-
35
-
-
0029794815
-
Wear of polyethylene cups in total hip arthroplasty: A study of specimens retrieved post mortem
-
Sychterz CJ, Moon KH, Hashimoto Y, Terefenko KM, Engh CA Jr, Bauer TW. Wear of polyethylene cups in total hip arthroplasty: A study of specimens retrieved post mortem. J Bone Joint Surg Am 1996;78A:1193-1200.
-
(1996)
J Bone Joint Surg Am
, vol.78 A
, pp. 1193-1200
-
-
Sychterz, C.J.1
Moon, K.H.2
Hashimoto, Y.3
Terefenko, K.M.4
Engh Jr., C.A.5
Bauer, T.W.6
-
36
-
-
0020826593
-
Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
-
Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses. J Biomed Mater Res 1983;17:829-842.
-
(1983)
J Biomed Mater Res
, vol.17
, pp. 829-842
-
-
Hood, R.W.1
Wright, T.M.2
Burstein, A.H.3
-
37
-
-
0026527293
-
Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
-
Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br 1992;74B:9-17.
-
(1992)
J Bone Joint Surg Br
, vol.74 B
, pp. 9-17
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
38
-
-
0026589837
-
Wear of polyethylene in total joint replacements: Observations from retrieved PCA knee implants
-
Wright TM, Rimnac CM, Stulberg SD, Mintz L, Tsao AK, Klein RW, McCrae C. Wear of polyethylene in total joint replacements: Observations from retrieved PCA knee implants. Clin Orthop Relat Res 1992;276:126-134.
-
(1992)
Clin Orthop Relat Res
, vol.276
, pp. 126-134
-
-
Wright, T.M.1
Rimnac, C.M.2
Stulberg, S.D.3
Mintz, L.4
Tsao, A.K.5
Klein, R.W.6
McCrae, C.7
-
39
-
-
18244405619
-
-
[dissertation]. Troy, NY: Rensselaer Polytechnic Institute
-
Radford DW. Shape instabilities in composites [dissertation]. Troy, NY: Rensselaer Polytechnic Institute; 1987.
-
(1987)
Shape Instabilities in Composites
-
-
Radford, D.W.1
-
41
-
-
9744249200
-
Assessing the dog as a model for human total hip replacement: Analysis of 38 postmortem retrieved canine cemented femoral components
-
Forthcoming
-
Skurla CP, Pluhar GE, Frankel DJ, Egger EL, James SP. Assessing the dog as a model for human total hip replacement: Analysis of 38 postmortem retrieved canine cemented femoral components. J Bone Joint Surg Br Forthcoming.
-
J Bone Joint Surg Br
-
-
Skurla, C.P.1
Pluhar, G.E.2
Frankel, D.J.3
Egger, E.L.4
James, S.P.5
-
43
-
-
0023070060
-
Acetabular lucent lines and mechanical stress in total hip arthroplasty
-
Goodman SB, Carter DR. Acetabular lucent lines and mechanical stress in total hip arthroplasty. J Arthroplasty 1987;2:219-224.
-
(1987)
J Arthroplasty
, vol.2
, pp. 219-224
-
-
Goodman, S.B.1
Carter, D.R.2
-
44
-
-
0024992920
-
Total hip and total knee replacement (first of two parts)
-
Harris WH, Sledge CB. Total hip and total knee replacement (first of two parts). New Eng J Med 1990;323:725-731.
-
(1990)
New Eng J Med
, vol.323
, pp. 725-731
-
-
Harris, W.H.1
Sledge, C.B.2
-
45
-
-
0030671410
-
Total hip arthroplasty in the young adult
-
Callaghan JJ, Forest EE, Sporer SM, Goetz DD, Johnston RC. Total hip arthroplasty in the young adult. Clin Orthop Relat Res 1997;344:257-262.
-
(1997)
Clin Orthop Relat Res
, vol.344
, pp. 257-262
-
-
Callaghan, J.J.1
Forest, E.E.2
Sporer, S.M.3
Goetz, D.D.4
Johnston, R.C.5
-
46
-
-
0027764408
-
Results of primary total hip arthroplasty in young patients
-
Callaghan JJ. Results of primary total hip arthroplasty in young patients. J Bone Joint Surg Am 1993;75A:1728-1734.
-
(1993)
J Bone Joint Surg Am
, vol.75 A
, pp. 1728-1734
-
-
Callaghan, J.J.1
-
47
-
-
2342534047
-
Long-term wear damage analysis of 38 postmortem retrieved canine total hip replacements
-
Skurla CP, James SP, Pluhar, GE. Long-term wear damage analysis of 38 postmortem retrieved canine total hip replacements. Trans Orthop Res Soc 2003;28:2.
-
(2003)
Trans Orthop Res Soc
, vol.28
, pp. 2
-
-
Skurla, C.P.1
James, S.P.2
Pluhar, G.E.3
-
48
-
-
2342478746
-
A novel method for assessing mechanical stability of acetabular components: Results from 38 postmortem retrieved canine implants
-
Skurla CP, James SP, Wheeler DL, Pluhar GE. A novel method for assessing mechanical stability of acetabular components: results from 38 postmortem retrieved canine implants. Trans Orthop Res Soc 2003;28:1361.
-
(2003)
Trans Orthop Res Soc
, vol.28
, pp. 1361
-
-
Skurla, C.P.1
James, S.P.2
Wheeler, D.L.3
Pluhar, G.E.4
|