메뉴 건너뛰기




Volumn 8, Issue 4, 2003, Pages 491-499

Validation of acetabular cup wear volume based on direct and two-dimensional measurements: Hip simulator analysis

Author keywords

Fluid displacement method; Hip simulator; Total hip arthroplasty; Volumetric wear

Indexed keywords

ACCURACY; ACETABULUM; ARTICLE; CALCULATION; CORRELATION ANALYSIS; GRAVIMETRY; IMPLANT; MODEL; SIMULATION; TOTAL HIP PROSTHESIS; VALIDATION PROCESS; VOLUMETRY;

EID: 0042476688     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-003-0674-2     Document Type: Article
Times cited : (22)

References (30)
  • 1
    • 0022108298 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III. The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors
    • Atkinson JR, Dowson D, Isaac JH, et al. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III. The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors. Wear 1985;104:225-44.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Isaac, J.H.3
  • 2
    • 0030635259 scopus 로고    scopus 로고
    • Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound
    • Berzins A, Sumner DR, Galante JO. Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound. J Biomed Mater Res 1998;39:120-9.
    • (1998) J Biomed Mater Res , vol.39 , pp. 120-129
    • Berzins, A.1    Sumner, D.R.2    Galante, J.O.3
  • 4
    • 0014457406 scopus 로고
    • The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip
    • Charnley J, Kamangar A, Longfield MD. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng 1969;7:31-9.
    • (1969) Med Biol Eng , vol.7 , pp. 31-39
    • Charnley, J.1    Kamangar, A.2    Longfield, M.D.3
  • 5
    • 0016823891 scopus 로고
    • Rate of wear in total hip replacement
    • Charnley J, Halley DK. Rate of wear in total hip replacement. Clin Orthop 1975;112:170-9.
    • (1975) Clin Orthop , vol.112 , pp. 170-179
    • Charnley, J.1    Halley, D.K.2
  • 7
    • 0030625737 scopus 로고    scopus 로고
    • Charnley wear model for validation of hip simulators-ball diameter versus polytetrafluoroethylene and polyethylene wear
    • Clarke IC, Good VD, Anissian L, et al. Charnley wear model for validation of hip simulators-ball diameter versus polytetrafluoroethylene and polyethylene wear. Proc Inst Mech Eng 1997;211: 25-36.
    • (1997) Proc Inst Mech Eng , vol.211 , pp. 25-36
    • Clarke, I.C.1    Good, V.D.2    Anissian, L.3
  • 8
    • 0031616211 scopus 로고    scopus 로고
    • The estimation of acetabular cup wear volume from two-dimensional measurements: A comprehensive analysis
    • Derbyshire B. The estimation of acetabular cup wear volume from two-dimensional measurements: a comprehensive analysis. Proc Inst Mech Eng 1998;212:281-91.
    • (1998) Proc Inst Mech Eng , vol.212 , pp. 281-291
    • Derbyshire, B.1
  • 9
    • 0028880699 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application
    • Devane PA, Bourne RB, Rorabeck CH, et al. Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. Clin Orthop 1995;319:317-26.
    • (1995) Clin Orthop , vol.319 , pp. 317-326
    • Devane, P.A.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 10
    • 0027579519 scopus 로고
    • An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups
    • Dowson D, Jobbins B, Seyed-Harraf A. An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups. Wear 1993;162-164:880-9.
    • (1993) Wear , vol.162-164 , pp. 880-889
    • Dowson, D.1    Jobbins, B.2    Seyed-Harraf, A.3
  • 11
    • 0030560772 scopus 로고    scopus 로고
    • Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model
    • Good VD, Clarke IC, Anissian L. Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model. J Biomed Mater Res 1996;33:275-83.
    • (1996) J Biomed Mater Res , vol.33 , pp. 275-283
    • Good, V.D.1    Clarke, I.C.2    Anissian, L.3
  • 12
    • 0033859530 scopus 로고    scopus 로고
    • Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: A dose-response study of protein concentration
    • Good VD, Clarke IC, Gustafson GA, et al. Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: a dose-response study of protein concentration. Acta Orthop Scand 2000;71:365-9.
    • (2000) Acta Orthop Scand , vol.71 , pp. 365-369
    • Good, V.D.1    Clarke, I.C.2    Gustafson, G.A.3
  • 13
    • 0029421292 scopus 로고
    • Measurement of wear in retrieved acetabular sockets
    • Hall RM, Unsworth A, Craig PS, et al. Measurement of wear in retrieved acetabular sockets. Proc Inst Mech Eng 1995;209:233-42.
    • (1995) Proc Inst Mech Eng , vol.209 , pp. 233-242
    • Hall, R.M.1    Unsworth, A.2    Craig, P.S.3
  • 14
    • 0030331546 scopus 로고    scopus 로고
    • Wear in retrieved Charnley acetabular sockets
    • Hall RM, Unsworth A, Siney P, et al. Wear in retrieved Charnley acetabular sockets. Proc Inst Mech Eng 1996;210:197-207.
    • (1996) Proc Inst Mech Eng , vol.210 , pp. 197-207
    • Hall, R.M.1    Unsworth, A.2    Siney, P.3
  • 15
    • 0032314915 scopus 로고    scopus 로고
    • The association between rates of wear in retrieved acetabular components and the radius of the femoral head
    • Hall RM, Siney P, Unsworth A, et al. The association between rates of wear in retrieved acetabular components and the radius of the femoral head. Proc Inst Mech Eng 1998;212:321-6.
    • (1998) Proc Inst Mech Eng , vol.212 , pp. 321-326
    • Hall, R.M.1    Siney, P.2    Unsworth, A.3
  • 16
    • 0031735284 scopus 로고    scopus 로고
    • Observations on the direction of wear in Charnley sockets retrieved at revision
    • Hall RM, Siney P, Wroblewski BM. Observations on the direction of wear in Charnley sockets retrieved at revision. J Bone Joint Surg Br 1998;80:1067-72.
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 1067-1072
    • Hall, R.M.1    Siney, P.2    Wroblewski, B.M.3
  • 17
    • 0012962157 scopus 로고
    • Polyethylene wear in total hip arthroplasty: Volumetric wear measurement of retrieved acetabular components
    • Hashimoto Y, Bauer TW, Jiang M, et al. Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components. Presented at the 41th Annual Meeting Orthopaedic Research Society, 1995, p 116-20.
    • (1995) 41th Annual Meeting Orthopaedic Research Society , pp. 116-120
    • Hashimoto, Y.1    Bauer, T.W.2    Jiang, M.3
  • 18
    • 0033047781 scopus 로고    scopus 로고
    • Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: Effect of starting resin and forming method
    • James SP, Lee KR, Beauregard GP, et al. Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: effect of starting resin and forming method. J Biomed Mater Res 1999;48:374-84.
    • (1999) J Biomed Mater Res , vol.48 , pp. 374-384
    • James, S.P.1    Lee, K.R.2    Beauregard, G.P.3
  • 19
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty: An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
    • Jasty M, Goetz DD, Bragdon CR, et al. Wear of polyethylene acetabular components in total hip arthroplasty: an analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg Am 1997;79:349-58.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 349-358
    • Jasty, M.1    Goetz, D.D.2    Bragdon, C.R.3
  • 20
    • 0027407506 scopus 로고
    • In vivo wear of polyethylene acetabular components
    • Kabo JM, Gebhard JS, Loren G, et al. In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 1993;75: 254-8.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 254-258
    • Kabo, J.M.1    Gebhard, J.S.2    Loren, G.3
  • 21
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 1990;72:518-28.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 22
    • 0032143429 scopus 로고    scopus 로고
    • The effects of polyethylene cup thickness on wear of total hip prostheses
    • Oonishi H, Iwaki H, Kin N, et al. The effects of polyethylene cup thickness on wear of total hip prostheses. J Mater Sci 1998;9:475-8.
    • (1998) J Mater Sci , vol.9 , pp. 475-478
    • Oonishi, H.1    Iwaki, H.2    Kin, N.3
  • 23
    • 0035069544 scopus 로고    scopus 로고
    • Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literature
    • Oparaugo PC, Clarke IC, Malchau H, et al. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature. Acta Orthop Scand 2001;72:22-8.
    • (2001) Acta Orthop Scand , vol.72 , pp. 22-28
    • Oparaugo, P.C.1    Clarke, I.C.2    Malchau, H.3
  • 24
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • Paul JP. Forces transmitted by joints in the human body. Proc Inst Mech Eng 1967;181:8-15.
    • (1967) Proc Inst Mech Eng , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 25
    • 0030923843 scopus 로고    scopus 로고
    • Digital edge-detection measurement of polyethylene wear after total hip arthroplasty
    • Shaver SM, Brown TD, Hillis SL, et al. Digital edge-detection measurement of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 1997;79:690-700.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 690-700
    • Shaver, S.M.1    Brown, T.D.2    Hillis, S.L.3
  • 26
    • 0033029624 scopus 로고    scopus 로고
    • Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    • Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop 1999;363:135-50.
    • (1999) Clin Orthop , vol.363 , pp. 135-150
    • Sochart, D.H.1
  • 27
    • 0029794815 scopus 로고    scopus 로고
    • Wear of polyethylene cups in total hip arthroplasty: A study of specimens retrieved post mortem
    • Sychterz CJ, Moon KH, Hashimoto Y, et al. Wear of polyethylene cups in total hip arthroplasty: a study of specimens retrieved post mortem. J Bone Joint Surg Am 1996;78:1193-200.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1193-1200
    • Sychterz, C.J.1    Moon, K.H.2    Hashimoto, Y.3
  • 28
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low-friction arthroplasty
    • Wroblewski BM. Direction and rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg Br 1985;67:757-61.
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 757-761
    • Wroblewski, B.M.1
  • 29
    • 0030666239 scopus 로고    scopus 로고
    • Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups
    • Yamaguchi M, Bauer TW, Hashimoto Y. Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups. J Bone Joint Surg Am 1997;79:1539-44.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1539-1544
    • Yamaguchi, M.1    Bauer, T.W.2    Hashimoto, Y.3
  • 30
    • 0033197866 scopus 로고    scopus 로고
    • Polyethylene wear vector in vivo: A three-dimensional analysis using retrieved acetabular components and radiographs
    • Yamaguchi M, Hashimoto Y, Akisue T, et al. Polyethylene wear vector in vivo: a three-dimensional analysis using retrieved acetabular components and radiographs. J Orthop Res 1999;17: 695-702.
    • (1999) J Orthop Res , vol.17 , pp. 695-702
    • Yamaguchi, M.1    Hashimoto, Y.2    Akisue, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.