-
1
-
-
0025179228
-
Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
-
Dumesnil J.G., Honos G.N., Lemieux M., and Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol. 16 (1990) 637-643
-
(1990)
J Am Coll Cardiol.
, vol.16
, pp. 637-643
-
-
Dumesnil, J.G.1
Honos, G.N.2
Lemieux, M.3
Beauchemin, J.4
-
2
-
-
0026438436
-
Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients
-
Dumesnil J.G., and Yoganathan A.P. Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardiothorac Surg 6 Suppl I (1992) S34-S38
-
(1992)
Eur J Cardiothorac Surg
, vol.6
, Issue.SUPPL. I
-
-
Dumesnil, J.G.1
Yoganathan, A.P.2
-
3
-
-
0034619384
-
Prosthesis-patient mismatch affects survival following aortic valve replacement
-
III-5-9
-
Rao V., Jamieson W.R.E., Ivanov J., Armstrong S., and David T.E. Prosthesis-patient mismatch affects survival following aortic valve replacement. Circulation 102 Suppl III (2000) III-5-9
-
(2000)
Circulation
, vol.102
, Issue.SUPPL. III
-
-
Rao, V.1
Jamieson, W.R.E.2
Ivanov, J.3
Armstrong, S.4
David, T.E.5
-
4
-
-
0036146208
-
Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up
-
Milano A.D., De C.M., Mecozzi G., D'Alfonso A., Scioti G., Nardi C., et al. Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up. Ann Thorac Surg 73 (2002) 37-43
-
(2002)
Ann Thorac Surg
, vol.73
, pp. 37-43
-
-
Milano, A.D.1
De, C.M.2
Mecozzi, G.3
D'Alfonso, A.4
Scioti, G.5
Nardi, C.6
-
5
-
-
0042859863
-
Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement
-
Blais C., Dumesnil J.G., Baillot R., Simard S., Doyle D., and Pibarot P. Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108 (2003) 983-988
-
(2003)
Circulation
, vol.108
, pp. 983-988
-
-
Blais, C.1
Dumesnil, J.G.2
Baillot, R.3
Simard, S.4
Doyle, D.5
Pibarot, P.6
-
6
-
-
10744233320
-
Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves
-
Ruel M., Rubens F.D., Masters R.G., Pipe A.L., Bedard P., Hendry P.J., et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves. J Thorac Cardiovasc Surg 127 (2004) 149-159
-
(2004)
J Thorac Cardiovasc Surg
, vol.127
, pp. 149-159
-
-
Ruel, M.1
Rubens, F.D.2
Masters, R.G.3
Pipe, A.L.4
Bedard, P.5
Hendry, P.J.6
-
7
-
-
13244251182
-
Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement
-
Tasca G., Brunelli F., Cirillo M., DallaTomba M., Mhagna Z., Troise G., et al. Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement. Ann Thorac Surg 79 (2005) 505-510
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 505-510
-
-
Tasca, G.1
Brunelli, F.2
Cirillo, M.3
DallaTomba, M.4
Mhagna, Z.5
Troise, G.6
-
8
-
-
33644858444
-
Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
-
Tasca G., Mhagna Z., Perotti S., Centurini P.B., Sabatini T., Amaducci A., et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 113 (2006) 570-576
-
(2006)
Circulation
, vol.113
, pp. 570-576
-
-
Tasca, G.1
Mhagna, Z.2
Perotti, S.3
Centurini, P.B.4
Sabatini, T.5
Amaducci, A.6
-
9
-
-
33747199079
-
Long-term outcomes after valve replacement for low-gradient aortic stenosis: impact of prosthesis-patient mismatch
-
Kulik A., Burwash I.G., Kapila V., Mesana T.G., and Ruel M. Long-term outcomes after valve replacement for low-gradient aortic stenosis: impact of prosthesis-patient mismatch. Circulation 114 Suppl 1 (2006) I5553-I5558
-
(2006)
Circulation
, vol.114
, Issue.SUPPL. 1
-
-
Kulik, A.1
Burwash, I.G.2
Kapila, V.3
Mesana, T.G.4
Ruel, M.5
-
10
-
-
33646205280
-
Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression
-
Ruel M., Al-Faleh H., Kulik A., Chan K.L., Mesana T.G., and Burwash I.G. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression. J Thorac Cardiovasc Surg 131 (2006) 1036-1044
-
(2006)
J Thorac Cardiovasc Surg
, vol.131
, pp. 1036-1044
-
-
Ruel, M.1
Al-Faleh, H.2
Kulik, A.3
Chan, K.L.4
Mesana, T.G.5
Burwash, I.G.6
-
11
-
-
33644870470
-
Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude medical mechanical prostheses in the aortic position
-
Mohty D., Malouf J.F., Girard S.E., Schaff H.V., Grill D.E., Enriquez-Sarano M.E., et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude medical mechanical prostheses in the aortic position. Circulation 113 (2006) 420-426
-
(2006)
Circulation
, vol.113
, pp. 420-426
-
-
Mohty, D.1
Malouf, J.F.2
Girard, S.E.3
Schaff, H.V.4
Grill, D.E.5
Enriquez-Sarano, M.E.6
-
12
-
-
33745044871
-
Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement
-
Walther T., Rastan A., Falk V., Lehmann S., Garbade J., Funkat A.K., et al. Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur J Cardiothorac Surg 30 (2006) 15-19
-
(2006)
Eur J Cardiothorac Surg
, vol.30
, pp. 15-19
-
-
Walther, T.1
Rastan, A.2
Falk, V.3
Lehmann, S.4
Garbade, J.5
Funkat, A.K.6
-
13
-
-
0019454724
-
Valve prosthesis-patient mismatch. A long-term sequela
-
Rahimtoola S.H., and Murphy E. Valve prosthesis-patient mismatch. A long-term sequela. Br Heart J 45 (1981) 331-335
-
(1981)
Br Heart J
, vol.45
, pp. 331-335
-
-
Rahimtoola, S.H.1
Murphy, E.2
-
14
-
-
0025341168
-
Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography
-
Dumesnil J.G., Honos G.N., Lemieux M., and Beauchemin J. Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography. Am J Cardiol 65 (1990) 1443-1448
-
(1990)
Am J Cardiol
, vol.65
, pp. 1443-1448
-
-
Dumesnil, J.G.1
Honos, G.N.2
Lemieux, M.3
Beauchemin, J.4
-
15
-
-
15944386365
-
Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement
-
Li M., Dumesnil J.G., Mathieu P., and Pibarot P. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement. J Am Coll Cardiol 45 (2005) 1034-1040
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1034-1040
-
-
Li, M.1
Dumesnil, J.G.2
Mathieu, P.3
Pibarot, P.4
-
16
-
-
34249085123
-
The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement
-
Lam B.K., Chan V., Hendry P., Ruel M., Masters R., Bédard P., et al. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. J Thorac Cardiovasc Surg 133 (2007) 1464-1473
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, pp. 1464-1473
-
-
Lam, B.K.1
Chan, V.2
Hendry, P.3
Ruel, M.4
Masters, R.5
Bédard, P.6
-
17
-
-
0033819953
-
Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
-
Pibarot P., and Dumesnil J.G. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 36 (2000) 1131-1141
-
(2000)
J Am Coll Cardiol
, vol.36
, pp. 1131-1141
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
18
-
-
33746393625
-
Prosthesis-patient mismatch: definition, clinical impact, and prevention
-
Pibarot P., and Dumesnil J.G. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart 92 (2006) 1022-1029
-
(2006)
Heart
, vol.92
, pp. 1022-1029
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
19
-
-
0033231145
-
Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve. Comparison of stentless versus stented bioprostheses
-
Pibarot P., Dumesnil J.G., Jobin J., Cartier P., Honos G., and Durand L.G. Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve. Comparison of stentless versus stented bioprostheses. J Am Coll Cardiol 34 (1999) 1609-1617
-
(1999)
J Am Coll Cardiol
, vol.34
, pp. 1609-1617
-
-
Pibarot, P.1
Dumesnil, J.G.2
Jobin, J.3
Cartier, P.4
Honos, G.5
Durand, L.G.6
-
20
-
-
0035004531
-
Patient-prosthesis mismatch can be predicted at the time of operation
-
Pibarot P., Dumesnil J.G., Cartier P.C., Métras J., and Lemieux M. Patient-prosthesis mismatch can be predicted at the time of operation. Ann Thorac Surg 71 Suppl 5 (2001) S265-S268
-
(2001)
Ann Thorac Surg
, vol.71
, Issue.SUPPL. 5
-
-
Pibarot, P.1
Dumesnil, J.G.2
Cartier, P.C.3
Métras, J.4
Lemieux, M.5
-
21
-
-
34147132312
-
Impact of prosthesis-patient mismatch on survival after mitral valve replacement
-
Magne J., Mathieu P., Dumesnil J.G., Tanné D., Dagenais F., Doyle D., et al. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation 115 (2007) 1336-1338
-
(2007)
Circulation
, vol.115
, pp. 1336-1338
-
-
Magne, J.1
Mathieu, P.2
Dumesnil, J.G.3
Tanné, D.4
Dagenais, F.5
Doyle, D.6
-
22
-
-
0034087385
-
Aortic valve replacement: is valve size important?
-
Medalion B., Blackstone E.H., Lytle B.W., White J., Arnold J.H., and Cosgrove D.M. Aortic valve replacement: is valve size important?. J Thorac Cardiovasc Surg. 119 (2000) 963-974
-
(2000)
J Thorac Cardiovasc Surg.
, vol.119
, pp. 963-974
-
-
Medalion, B.1
Blackstone, E.H.2
Lytle, B.W.3
White, J.4
Arnold, J.H.5
Cosgrove, D.M.6
-
23
-
-
0141742218
-
Prosthesis size and long-term survival after aortic valve replacement
-
Blackstone E.H., Cosgrove D.M., Jamieson W.R., Birkmeyer N.J., Lemmer Jr. J.H., Miller D.C., et al. Prosthesis size and long-term survival after aortic valve replacement. J Thorac Cardiovasc Surg 126 3 (2003) 783-793
-
(2003)
J Thorac Cardiovasc Surg
, vol.126
, Issue.3
, pp. 783-793
-
-
Blackstone, E.H.1
Cosgrove, D.M.2
Jamieson, W.R.3
Birkmeyer, N.J.4
Lemmer Jr., J.H.5
Miller, D.C.6
-
24
-
-
21044431634
-
Impact of prosthesis-patient size on functional recovery after aortic valve replacement
-
Koch C.G., Khandwala F., Estafanous F.G., Loop F.D., and Blackstone E.H. Impact of prosthesis-patient size on functional recovery after aortic valve replacement. Circulation 111 (2005) 3221-3229
-
(2005)
Circulation
, vol.111
, pp. 3221-3229
-
-
Koch, C.G.1
Khandwala, F.2
Estafanous, F.G.3
Loop, F.D.4
Blackstone, E.H.5
-
25
-
-
34249081193
-
Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method
-
Dec 12 [Epub ahead of print].
-
Bleiziffer S., Eichinger W.B., Hettich I., Guenzinger R., Ruzicka D., Bauernschmitt R., et al. Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method. Heart (2006) Dec 12 [Epub ahead of print].
-
(2006)
Heart
-
-
Bleiziffer, S.1
Eichinger, W.B.2
Hettich, I.3
Guenzinger, R.4
Ruzicka, D.5
Bauernschmitt, R.6
-
26
-
-
0034619521
-
Impact of atrioventricular compliance on pulmonary artery pressure in mitral stenosis: an exercise echocardiographic study
-
Schwammenthal E., Vered Z., Agranat O., Kaplinsky E., Rabinowitz B., and Feinberg M.S. Impact of atrioventricular compliance on pulmonary artery pressure in mitral stenosis: an exercise echocardiographic study. Circulation 102 (2000) 2378-2384
-
(2000)
Circulation
, vol.102
, pp. 2378-2384
-
-
Schwammenthal, E.1
Vered, Z.2
Agranat, O.3
Kaplinsky, E.4
Rabinowitz, B.5
Feinberg, M.S.6
-
27
-
-
0029115783
-
Doppler echocardiographic assessment with the continuity equation of St. Jude medical mechanical prostheses in the mitral valve position
-
Bitar J.N., Lechin M.E., Salazar G., and Zoghbi W.A. Doppler echocardiographic assessment with the continuity equation of St. Jude medical mechanical prostheses in the mitral valve position. Am J Cardiol 76 (1995) 287-293
-
(1995)
Am J Cardiol
, vol.76
, pp. 287-293
-
-
Bitar, J.N.1
Lechin, M.E.2
Salazar, G.3
Zoghbi, W.A.4
-
28
-
-
1442300132
-
Late results after mitral valve replacement with bileaflet mechanical prosthesis in children: evaluation of prosthesis-patient mismatch
-
Masuda M., Kado H., Tatewaki H., Shiokawa Y., and Yasui H. Late results after mitral valve replacement with bileaflet mechanical prosthesis in children: evaluation of prosthesis-patient mismatch. Ann Thorac Surg 77 (2004) 913-917
-
(2004)
Ann Thorac Surg
, vol.77
, pp. 913-917
-
-
Masuda, M.1
Kado, H.2
Tatewaki, H.3
Shiokawa, Y.4
Yasui, H.5
-
29
-
-
0036306087
-
Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch
-
Castro L.J., Arcidi J.M.J., Fisher A.L., and Gaudiani V.A. Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch. Ann Thorac Surg 74 (2002) 31-36
-
(2002)
Ann Thorac Surg
, vol.74
, pp. 31-36
-
-
Castro, L.J.1
Arcidi, J.M.J.2
Fisher, A.L.3
Gaudiani, V.A.4
|