-
1
-
-
0019426538
-
The hemodynamic effect of rapid fTluid infusion in critically ill patients
-
Calvin JE, Driedger AA, Sibbald WJ. The hemodynamic effect of rapid fTluid infusion in critically ill patients. Surgery 1981; 90: 61-76.
-
(1981)
Surgery
, vol.90
, pp. 61-76
-
-
Calvin, J.E.1
Driedger, A.A.2
Sibbald, W.J.3
-
2
-
-
0033924592
-
Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
-
Michard F, Boussat S, Chemla D et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162: 134-8.
-
(2000)
Am J Respir Crit Care Med
, vol.162
, pp. 134-138
-
-
Michard, F.1
Boussat, S.2
Chemla, D.3
-
3
-
-
0031029099
-
Elastic energy as an index of right ventricular filling
-
Squara P, Journois D, Estagnasie P et al. Elastic energy as an index of right ventricular filling. Chest 1997; 111: 351-8.
-
(1997)
Chest
, vol.111
, pp. 351-358
-
-
Squara, P.1
Journois, D.2
Estagnasie, P.3
-
4
-
-
0032437998
-
Systolic pressure variation as a guide to fluid therapy in patients with sepsisinduced hypotension
-
Tavernier B, Makhotine O, Lebuffe G et al. Systolic pressure variation as a guide to fluid therapy in patients with sepsisinduced hypotension. Anesthesiology 1998; 89: 1313-21.
-
(1998)
Anesthesiology
, vol.89
, pp. 1313-1321
-
-
Tavernier, B.1
Makhotine, O.2
Lebuffe, G.3
-
5
-
-
19944404764
-
Pulse pressure and stroke Volume variations during severe haemorrhage in ventilated dogs
-
Berkenstadt H, Friedman Z, Preisman S et al. Pulse pressure and stroke Volume variations during severe haemorrhage in ventilated dogs. Br J Anaesth 2005; 94: 721-6.
-
(2005)
Br J Anaesth
, vol.94
, pp. 721-726
-
-
Berkenstadt, H.1
Friedman, Z.2
Preisman, S.3
-
6
-
-
23744504093
-
Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
-
Hofer CK, Muller SM, Furrer L et al. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005; 128: 848-54.
-
(2005)
Chest
, vol.128
, pp. 848-854
-
-
Hofer, C.K.1
Muller, S.M.2
Furrer, L.3
-
7
-
-
0036219991
-
Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
-
Reuter DA, Felbinger TW, Schmidt C et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28: 392-8.
-
(2002)
Intensive Care Med
, vol.28
, pp. 392-398
-
-
Reuter, D.A.1
Felbinger, T.W.2
Schmidt, C.3
-
8
-
-
0035080242
-
Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
-
Berkenstadt H, Margalit N, Hadani M et al. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001; 92: 984-9.
-
(2001)
Anesth Analg
, vol.92
, pp. 984-989
-
-
Berkenstadt, H.1
Margalit, N.2
Hadani, M.3
-
9
-
-
28844464011
-
Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators
-
Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth 2005; 95: 746-55.
-
(2005)
Br J Anaesth
, vol.95
, pp. 746-755
-
-
Preisman, S.1
Kogan, S.2
Berkenstadt, H.3
Perel, A.4
-
10
-
-
0024343884
-
The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs
-
Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 1989; 15: 368-71.
-
(1989)
Intensive Care Med
, vol.15
, pp. 368-371
-
-
Szold, A.1
Pizov, R.2
Segal, E.3
Perel, A.4
-
11
-
-
17444414557
-
Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume
-
De Backer D, Heenen S, Piagnerelli M et al. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005; 31: 517-23.
-
(2005)
Intensive Care Med
, vol.31
, pp. 517-523
-
-
De Backer, D.1
Heenen, S.2
Piagnerelli, M.3
-
12
-
-
0036152801
-
Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
-
Godje O, Hoke K, Goetz AE et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 2002; 30: 52-8.
-
(2002)
Crit Care Med
, vol.30
, pp. 52-58
-
-
Godje, O.1
Hoke, K.2
Goetz, A.E.3
-
13
-
-
0027195184
-
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
-
Wesseling KH, Jansen JR, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 1993; 74: 2566-73.
-
(1993)
J Appl Physiol
, vol.74
, pp. 2566-2573
-
-
Wesseling, K.H.1
Jansen, J.R.2
Settels, J.J.3
Schreuder, J.J.4
-
14
-
-
0034027184
-
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
-
Sakka SG, Ruhl CC, Pfeiffer UJ et al. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med 2000; 26: 180-7.
-
(2000)
Intensive Care Med
, vol.26
, pp. 180-187
-
-
Sakka, S.G.1
Ruhl, C.C.2
Pfeiffer, U.J.3
-
15
-
-
0037407062
-
Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
-
Wiesenack C, Prasser C, Rodig G, Keyl C. Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients. Anesth Analg 2003; 96: 1254-7.
-
(2003)
Anesth Analg
, vol.96
, pp. 1254-1257
-
-
Wiesenack, C.1
Prasser, C.2
Rodig, G.3
Keyl, C.4
-
16
-
-
0141453423
-
Influence of tidal volume on stroke volume variation. Does it really matter?
-
Michard F, Teboul JL, Richard C. Influence of tidal volume on stroke volume variation. Does it really matter? Intensive Care Med 2003; 29: 1613.
-
(2003)
Intensive Care Med
, vol.29
, pp. 1613
-
-
Michard, F.1
Teboul, J.L.2
Richard, C.3
-
17
-
-
0037352554
-
Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
-
Reuter DA, Bayerlein J, Goepfert MS et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 2003; 29: 476-80.
-
(2003)
Intensive Care Med
, vol.29
, pp. 476-480
-
-
Reuter, D.A.1
Bayerlein, J.2
Goepfert, M.S.3
-
19
-
-
14844348178
-
Assessing fluid responsiveness during open chest conditions
-
Reuter DA, Goepfert MS, Goresch T et al. Assessing fluid responsiveness during open chest conditions. Br J Anaesth 2005; 94: 318-23.
-
(2005)
Br J Anaesth
, vol.94
, pp. 318-323
-
-
Reuter, D.A.1
Goepfert, M.S.2
Goresch, T.3
-
20
-
-
0037906107
-
-
Reuter DA, Kirchner A, Felbinger TWet al. Usefulness of left ventricular stroke variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003; 31: 1399-404.
-
Reuter DA, Kirchner A, Felbinger TWet al. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003; 31: 1399-404.
-
-
-
-
21
-
-
33748934573
-
Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation
-
Perner A, Faber T. Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. Acta Anaesthesiol Scand 2006; 50: 1068-73.
-
(2006)
Acta Anaesthesiol Scand
, vol.50
, pp. 1068-1073
-
-
Perner, A.1
Faber, T.2
-
22
-
-
9244234395
-
A comparison of changes in cardiac preload variables during graded hypovolemia and hypervolemia in mechanically ventilated dogs
-
table of contents
-
Fujita Y, Yamamoto T, Sano I et al. A comparison of changes in cardiac preload variables during graded hypovolemia and hypervolemia in mechanically ventilated dogs. Anesth Analg 2004; 99: 1780-6, table of contents.
-
(2004)
Anesth Analg
, vol.99
, pp. 1780-1786
-
-
Fujita, Y.1
Yamamoto, T.2
Sano, I.3
-
23
-
-
29844448951
-
Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model
-
Bajorat J, Hofmockel R, Vagts DA et al. Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 2006; 23: 23-30.
-
(2006)
Eur J Anaesthesiol
, vol.23
, pp. 23-30
-
-
Bajorat, J.1
Hofmockel, R.2
Vagts, D.A.3
|