메뉴 건너뛰기




Volumn 4, Issue 1, 2007, Pages

A new approach towards a minimal invasive retina implant

Author keywords

[No Author keywords available]

Indexed keywords

DISEASES; ELECTRODES; IMPLANTS (SURGICAL); NEURONS; PATIENT TREATMENT; VISION;

EID: 33847632184     PISSN: 17412560     EISSN: 17412552     Source Type: Journal    
DOI: 10.1088/1741-2560/4/1/S05     Document Type: Article
Times cited : (42)

References (91)
  • 1
    • 0035180957 scopus 로고    scopus 로고
    • Electrical stimulation of the visual system: From empirical approaches to the development of visual implants
    • Uhlig C E, Taneri S, Benner F P and Gerding H 2001 Electrical stimulation of the visual system: from empirical approaches to the development of visual implants Ophthalmologe 98 1089-96
    • (2001) Ophthalmologe , vol.98 , pp. 1089-1096
    • Uhlig, C.E.1    Taneri, S.2    Benner, F.P.3    Gerding, H.4
  • 2
    • 57149118074 scopus 로고
    • Où ĺon rend compte de quelques tentatives que ĺon a faites pour guérir plusieurs maladies par l'électricité
    • LeRoy C 1755 Où ĺon rend compte de quelques tentatives que ĺon a faites pour guérir plusieurs maladies par l'électricité Hist. Acad. R. Sci. (Paris), Mém. Math. Phys. 1755 87-9
    • (1755) Hist. Acad. R. Sci. (Paris), Mém. Math. Phys. , vol.1755 , pp. 87-89
    • Leroy, C.1
  • 3
    • 0001032743 scopus 로고
    • De viribus electricitatis in motu musculary, commentaries
    • Galvani L 1791 De viribus electricitatis in motu musculary, commentaries De Bononiensi Sci. Artium Inst. atque Acad. 7 363-418
    • (1791) De Bononiensi Sci. Artium Inst. Atque Acad. , vol.7 , pp. 363-418
    • Galvani, L.1
  • 4
    • 0003004564 scopus 로고
    • Visual responses to cortical stimulation in the blind
    • Button J and Puttnam T 1962 Visual responses to cortical stimulation in the blind J. Iowa St. Med. Soc. 52 17-21
    • (1962) J. Iowa St. Med. Soc. , vol.52 , pp. 17-21
    • Button, J.1    Puttnam, T.2
  • 5
    • 0016296648 scopus 로고
    • Implanted stimulators of the visual cortex as visual prosthetic devices
    • Brindley G S and Rushton D 1974 Implanted stimulators of the visual cortex as visual prosthetic devices Trans. Am. Acad. Ophthalmol. Otolaryngol. 78 741-5
    • (1974) Trans. Am. Acad. Ophthalmol. Otolaryngol. , vol.78 , pp. 741-745
    • Brindley, G.S.1    Rushton, D.2
  • 6
    • 33847659734 scopus 로고
    • Tassicker G E 1956 US patent Specification 2760483
    • (1956)
    • Tassiker, G.E.1
  • 7
    • 0842327585 scopus 로고
    • Preliminary report on a retinal stimulator
    • Tassicker G E 1656 Preliminary report on a retinal stimulator Br. J. Physiol. Opt. 13 102-5
    • (1656) Br. J. Physiol. Opt. , vol.13 , pp. 102-105
    • Tassiker, G.E.1
  • 8
    • 77049208323 scopus 로고
    • The site of electrical excitation of the human eye
    • Brindley G S 1962 The site of electrical excitation of the human eye J. Physiol. 127 189-200
    • (1962) J. Physiol. , vol.127 , pp. 189-200
    • Brindley, G.S.1
  • 10
    • 0017357135 scopus 로고
    • The electrical stimulation of the retina by indwelling electrodes
    • Dawson W W and Radtke N D 1977 The electrical stimulation of the retina by indwelling electrodes Invest. Ophthalmol. Vis. Sci. 16 249-52
    • (1977) Invest. Ophthalmol. Vis. Sci. , vol.16 , pp. 249-252
    • Dawson, W.W.1    Radtke, N.D.2
  • 12
    • 33847644665 scopus 로고
    • Visual sensation produced by electrical stimulation of the retinal surface in patients with end-stage retinitis pigmentosa
    • Humayun M S, Probst R H, Hickingbotham D, de Juan E and Dagnelie G 1993 Visual sensation produced by electrical stimulation of the retinal surface in patients with end-stage retinitis pigmentosa Invest. Ophthalmol. Vis. Sci. 34 S:659
    • (1993) Invest. Ophthalmol. Vis. Sci. , vol.34 , pp. 659
    • Humayun, M.S.1    Probst, R.H.2    Hickingbotham, D.3    De Juan, E.4    Dagnelie, G.5
  • 14
    • 0030826554 scopus 로고    scopus 로고
    • Learning retina implants with epiretinal contacts
    • Eckmiller R 1997 Learning retina implants with epiretinal contacts Ophthalmic Res. 29 281-9
    • (1997) Ophthalmic Res. , vol.29 , pp. 281-289
    • Eckmiller, R.1
  • 15
    • 9844238701 scopus 로고    scopus 로고
    • The development of subretinal microphotodiodes for replacement of degenerated photoreceptors
    • Zrenner E et al 1997 The development of subretinal microphotodiodes for replacement of degenerated photoreceptors Ophthalmic Res. 29 269-80
    • (1997) Ophthalmic Res. , vol.29 , pp. 269-280
    • Zrenner, E.1    Al, E.2
  • 16
    • 0030151086 scopus 로고    scopus 로고
    • Ocular implants for the blind
    • Wyatt J and Rizzo J 1996 Ocular implants for the blind IEEE Spectr. 33 47-53
    • (1996) IEEE Spectr. , vol.33 , Issue.5 , pp. 47-53
    • Wyatt, J.1    Rizzo, J.2
  • 17
    • 3042885534 scopus 로고    scopus 로고
    • Prospect for a visual prosthesis
    • Rizzo J F and Wyatt J 1997 Prospect for a visual prosthesis Neuroscientist 3 251-62
    • (1997) Neuroscientist , vol.3 , pp. 251-262
    • Rizzo, J.F.1    Wyatt, J.2
  • 21
    • 22044451448 scopus 로고    scopus 로고
    • A method and technical equipment for an acute human trial to evaluate retina implant technology
    • Hornig R et al 2005 A method and technical equipment for an acute human trial to evaluate retina implant technology J. Neural. Eng. 2 S129-34
    • (2005) J. Neural. Eng. , vol.2 , Issue.1
    • Hornig, R.1    Al, E.2
  • 22
    • 26444450974 scopus 로고    scopus 로고
    • Epiretinal visual prosthesis
    • Walter P and Mokwa W 2005 Epiretinal visual prosthesis Ophthalmologe 102 933-40
    • (2005) Ophthalmologe , vol.102 , pp. 933-940
    • Walter, P.1    Mokwa, W.2
  • 23
    • 0030906537 scopus 로고    scopus 로고
    • Subretinal electrical stimulation of the rabbit retina
    • Chow A Y and Chow V Y 1997 Subretinal electrical stimulation of the rabbit retina Neurosci. Lett. 225 13-6
    • (1997) Neurosci. Lett. , vol.225 , Issue.1 , pp. 13-16
    • Chow, A.Y.1    Chow, V.Y.2
  • 25
    • 0037039812 scopus 로고    scopus 로고
    • Will retina implants restore vision?
    • Zrenner E 2002 Will retina implants restore vision? Science 295 2213
    • (2002) Science , vol.295 , Issue.5557 , pp. 1022
    • Zrenner, E.1
  • 28
    • 22044458583 scopus 로고    scopus 로고
    • Design of a high-resolution optoelectronic retinal prosthesis
    • Palanker D, Vankov A, Huie P and Baccus S 2005 Design of a high-resolution optoelectronic retinal prosthesis J. Neural Eng. 2 S105-20
    • (2005) J. Neural Eng. , vol.2 , Issue.1
    • Palanker, D.1    Vankov, A.2    Huie, P.3    Baccus, S.4
  • 29
    • 1842582778 scopus 로고    scopus 로고
    • The artificial silicon retina microchip for the treatment of vision loss form retinitis pigmentosa
    • Chow A Y, Chow V Y, Packo K H, Pollack J S, Peyman G A and Schuchard R 2005 The artificial silicon retina microchip for the treatment of vision loss form retinitis pigmentosa Arch. Ophthalmol. 123 460-9
    • (2005) Arch. Ophthalmol. , vol.123 , pp. 460-469
    • Chow, A.Y.1    Chow, V.Y.2    Packo, K.H.3    Pollack, J.S.4    Peyman, G.A.5    Schuchard, R.6
  • 32
    • 2542443698 scopus 로고    scopus 로고
    • Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes
    • Sakaguchi H et al 2004 Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes Japan. J. Ophthalmol. 48 256-61
    • (2004) Japan. J. Ophthalmol. , vol.48 , Issue.3 , pp. 256-261
    • Sakaguchi, H.1    Al, E.2
  • 34
    • 27644492795 scopus 로고    scopus 로고
    • Feasibility of extraocular stimulation for a retinal prosthesis
    • Chowdhury V, Morley J W and Coroneo M T 2005 Feasibility of extraocular stimulation for a retinal prosthesis Can. J. Ophthalmol. 40 563-72
    • (2005) Can. J. Ophthalmol. , vol.40 , pp. 563-572
    • Chowdhury, V.1    Morley, J.W.2    Coroneo, M.T.3
  • 35
    • 27844599777 scopus 로고    scopus 로고
    • Stimulation of the retina with a multielectrode extraocular visual prosthesis
    • Chowdhury V, Morley J W and Coroneo M T 2005 Stimulation of the retina with a multielectrode extraocular visual prosthesis ANZ J. Surg. 75 697-704
    • (2005) ANZ J. Surg. , vol.75 , Issue.8 , pp. 697-704
    • Chowdhury, V.1    Morley, J.W.2    Coroneo, M.T.3
  • 36
    • 22944486651 scopus 로고    scopus 로고
    • Evaluation of exraocular electrodes for a retinal prosthesis using evoked potentials in cat visual cortex
    • Chowdhury V, Morley J W and Coroneo M T 2005 Evaluation of exraocular electrodes for a retinal prosthesis using evoked potentials in cat visual cortex J. Clin. Neurosci. 12 574-9
    • (2005) J. Clin. Neurosci. , vol.12 , Issue.5 , pp. 574-579
    • Chowdhury, V.1    Morley, J.W.2    Coroneo, M.T.3
  • 37
    • 0031625024 scopus 로고    scopus 로고
    • A computational study on an electrode array in a hybrid retinal implant
    • Yagi T and Watanabe M 1998 A computational study on an electrode array in a hybrid retinal implant Proc. 1998 Int. Joint Conf. Neural Networks pp 780-3
    • (1998) Proc. 1998 Int. Joint Conf. Neural Networks , pp. 780-783
    • Yagi, T.1    Watanabe, M.2
  • 38
    • 0038598030 scopus 로고    scopus 로고
    • Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
    • Humayun M S et al 2003 Visual perception in a blind subject with a chronic microelectronic retinal prosthesis Vis. Res. 43 2573-81
    • (2003) Vis. Res. , vol.43 , Issue.24 , pp. 2573-2581
    • Humayun, M.S.1    Al, E.2
  • 44
    • 0029964253 scopus 로고    scopus 로고
    • Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex
    • Schmidt E M, Bak M J, Hambrecht F T, Kufta C V, O'Rourke D K and Vallabhanath P 1996 Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex Brain 119 507-22
    • (1996) Brain , vol.119 , Issue.2 , pp. 507-522
    • Schmidt, E.M.1    Bak, M.J.2    Hambrecht, F.T.3    Kufta, C.V.4    O'Rourke, D.K.5    Vallabhanath, P.6
  • 45
    • 0032947055 scopus 로고    scopus 로고
    • A neuronal interface for a cortical vision prosthesis
    • Norman R A, Maynard E M, Rousche P J and Rousche D J 1999 A neuronal interface for a cortical vision prosthesis Vis. Res. 39 2577-87
    • (1999) Vis. Res. , vol.39 , Issue.15 , pp. 2577-2587
    • Norman, R.A.1    Maynard, E.M.2    Rousche, P.J.3    Rousche, D.J.4
  • 48
    • 23844461520 scopus 로고    scopus 로고
    • Implantation of stimulation electrodes in the subretinal space to demonstrate cortical responses in Yucatan minipig in the course of visual prosthesis development
    • Sachs H G, Gekeler F, Schwahn H, Jakob W, Kohler M, Schulmeyer F, Marienhagen J, Brunner U and Framme C 2005 Implantation of stimulation electrodes in the subretinal space to demonstrate cortical responses in Yucatan minipig in the course of visual prosthesis development Eur. J. Ophthalmol. 15 493-9
    • (2005) Eur. J. Ophthalmol. , vol.15 , pp. 493-499
    • Sachs, H.G.1    Gekeler, F.2    Schwahn, H.3    Jakob, W.4    Kohler, M.5    Schulmeyer, F.6    Marienhagen, J.7    Brunner, U.8    Framme, C.9
  • 51
    • 0026460822 scopus 로고
    • Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa
    • Stone J L, Barlow W E, Humayun M S, de Juan E and Milam A H 1992 Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa Arch. Ophthalmol. 110 1634-9
    • (1992) Arch. Ophthalmol. , vol.110 , pp. 1634-1639
    • Stone, J.L.1    Barlow, W.E.2    Humayun, M.S.3    De Juan, E.4    Milam, A.H.5
  • 52
    • 0030940097 scopus 로고    scopus 로고
    • Preservation of the inner retina in retinitis pigmentosa
    • Santos A et al 1997 Preservation of the inner retina in retinitis pigmentosa Arch. Ophthalmol. 115 511-5
    • (1997) Arch. Ophthalmol. , vol.115 , pp. 511-515
    • Santos, A.1    Al, E.2
  • 53
    • 0032952549 scopus 로고    scopus 로고
    • Morphometric analysis of the extracellular retina from post-mortem eyes with retinits pigmentosa
    • Humayun M S et al 1999 Morphometric analysis of the extracellular retina from post-mortem eyes with retinits pigmentosa Invest. Ophthalmol. Vis. Sci. 40 143-8
    • (1999) Invest. Ophthalmol. Vis. Sci. , vol.40 , pp. 143-148
    • Humayun, M.S.1    Al, E.2
  • 55
    • 0036672499 scopus 로고    scopus 로고
    • Morphometric analysis of the macula in eyes with geographic atrophy due to age-related macular degeneration
    • Kim S Y, Sadda S, Humayun M S, de Juan E, Melia B M and Green W R 2002 Morphometric analysis of the macula in eyes with geographic atrophy due to age-related macular degeneration Retina 22 464-70
    • (2002) Retina , vol.22 , Issue.4 , pp. 464-470
    • Kim, S.Y.1    Sadda, S.2    Humayun, M.S.3    De Juan, E.4    Melia, B.M.5    Green, W.R.6
  • 56
    • 0036671377 scopus 로고    scopus 로고
    • Morphometric analysis of the macula in eyes with disciform age-related macular degeneration
    • Kim S Y et al 2002 Morphometric analysis of the macula in eyes with disciform age-related macular degeneration Retina 22 471-7
    • (2002) Retina , vol.22 , Issue.4 , pp. 471-477
    • Kim, S.Y.1    Al, E.2
  • 61
    • 0345445897 scopus 로고    scopus 로고
    • Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials
    • Rizzo J F, Wyatt J, Loewenstein J, Kelly S and Shire D 2003 Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials Invest. Ophthalmol. Vis. Sci. 44 5362-9
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , Issue.12 , pp. 5362-5369
    • Rizzo, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 62
    • 0345014794 scopus 로고    scopus 로고
    • Methods and perceptual threshold for short-term electrical stimulation of human retina with microelectrode arrays
    • Rizzo J F, Wyatt J, Loewenstein J, Kelly S and Shire D 2003 Methods and perceptual threshold for short-term electrical stimulation of human retina with microelectrode arrays Invest. Ophthalmol. Vis. Sci. 44 5355-61
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , Issue.12 , pp. 5355-5361
    • Rizzo, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 65
    • 33746919949 scopus 로고    scopus 로고
    • Thresholds for activation of rabbit ganglion cells with a subretinal electrode
    • Jensen R J and Rizzo J F 2006 Thresholds for activation of rabbit ganglion cells with a subretinal electrode Exp. Eye Res. 83 367-73
    • (2006) Exp. Eye Res. , vol.83 , Issue.2 , pp. 367-373
    • Jensen, R.J.1    Rizzo, J.F.2
  • 66
    • 33644988038 scopus 로고    scopus 로고
    • Sites of neuronal excitation by epiretinal electrical stimulation
    • Schiefer M A and Grill W M 2006 Sites of neuronal excitation by epiretinal electrical stimulation IEEE Trans. Neural Syst. Rehabil. Eng. 14 5-13
    • (2006) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.14 , Issue.1 , pp. 5-13
    • Schiefer, M.A.1    Grill, W.M.2
  • 67
    • 33744937327 scopus 로고    scopus 로고
    • In vivo electrical stimulation of rabbit retina: Effect of stimulus duration and electrical field orientation
    • Shah H A, Montezuma S R and Rizzo J F 2006 In vivo electrical stimulation of rabbit retina: effect of stimulus duration and electrical field orientation Exp. Eye Res. 83 247-54
    • (2006) Exp. Eye Res. , vol.83 , Issue.2 , pp. 247-254
    • Shah, H.A.1    Montezuma, S.R.2    Rizzo, J.F.3
  • 68
    • 33747343240 scopus 로고    scopus 로고
    • Visual resolution with retinal implants estimated from recordings in cat visual cortex
    • Eckhorn R et al 2006 Visual resolution with retinal implants estimated from recordings in cat visual cortex Vis. Res. 46 2657-90
    • (2006) Vis. Res. , vol.46 , Issue.17 , pp. 2675-2690
    • Eckhorn, R.1    Al, E.2
  • 69
    • 22044450476 scopus 로고    scopus 로고
    • Long-term stimulation by active epiretinal implants in normal and RCD1 dogs
    • Guven D et al 2005 Long-term stimulation by active epiretinal implants in normal and RCD1 dogs J. Neural. Eng. 2 S65-73
    • (2005) J. Neural. Eng. , vol.2 , Issue.1
    • Guven, D.1    Al, E.2
  • 71
    • 33645417029 scopus 로고    scopus 로고
    • Paragraph text reading using a pixelized prosthetic vision stimulator: Parameter dependence and task learning in free-viewing conditions
    • Dagnelie G, Barnett D, Humayun M S and Thompson R W 2006 Paragraph text reading using a pixelized prosthetic vision stimulator: parameter dependence and task learning in free-viewing conditions Invest. Ophthalmol. Vis. Sci. 47 1241-50
    • (2006) Invest. Ophthalmol. Vis. Sci. , vol.47 , Issue.3 , pp. 1241-1250
    • Dagnelie, G.1    Barnett, D.2    Humayun, M.S.3    Thompson, R.W.4
  • 73
    • 0032859932 scopus 로고    scopus 로고
    • Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs
    • Majii A, Humayun M S, Weiland J D, Suzuki S, D'Anna S A and de Juan E 1999 Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs Invest. Ophthalmol. Vis. Sci. 40 2073-81
    • (1999) Invest. Ophthalmol. Vis. Sci. , vol.40 , pp. 2073-2081
    • Majii, A.1    Humayun, M.S.2    Weiland, J.D.3    Suzuki, S.4    D'Anna, S.A.5    De Juan, E.6
  • 75
    • 0842289408 scopus 로고    scopus 로고
    • Surgical approaches to retinal prosthesis implantation
    • Husain D and Loewenstein J I 2004 Surgical approaches to retinal prosthesis implantation Int. Ophthalmol. Clin. 44 105-11
    • (2004) Int. Ophthalmol. Clin. , vol.44 , Issue.1 , pp. 105-111
    • Husain, D.1    Loewenstein, J.I.2
  • 76
    • 31044443749 scopus 로고    scopus 로고
    • Implantation and testing of subretinal film electrodes in domestic pigs
    • Schanze T, Sachs H G, Wiesenack C, Brunner U and Sailer H 2006 Implantation and testing of subretinal film electrodes in domestic pigs Exp. Eye Res. 82 1156-7
    • (2006) Exp. Eye Res. , vol.82 , Issue.2 , pp. 332-1157
    • Schanze, T.1    Sachs, H.G.2    Wiesenack, C.3    Brunner, U.4    Sailer, H.5
  • 77
    • 22044450029 scopus 로고    scopus 로고
    • Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development
    • Sachs H G, Schanze T, Brunner U, Sailer H and Wiesenack C 2005 Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development J. Neural Eng. 2 S57-64
    • (2005) J. Neural Eng. , vol.2 , Issue.1
    • Sachs, H.G.1    Schanze, T.2    Brunner, U.3    Sailer, H.4    Wiesenack, C.5
  • 80
    • 33847669848 scopus 로고    scopus 로고
    • Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
    • Gerding H, Benner F P and Taneri S 2007 Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit J. Neural Eng. 4 S38-49
    • (2007) J. Neural Eng. , vol.4
    • Gerding, H.1    Benner, F.P.2    Taneri, S.3
  • 81
    • 33847632608 scopus 로고    scopus 로고
    • Büchele Rodrigues E 2003 Retina implant project: chronic implantation of active epiretinal implants Doctoral Thesis Medical Faculty, University of Marburg
    • (2003) Doctoral Thesis
    • Büchele Rodrigues, E.1
  • 82
    • 0038779549 scopus 로고    scopus 로고
    • Retinal detachment and phthisis bulbi after implantation of an iris prosthetic system
    • Taneri S and Gerding H 2003 Retinal detachment and phthisis bulbi after implantation of an iris prosthetic system J. Cataract Refract. Surg. 29 1034-8
    • (2003) J. Cataract Refract. Surg. , vol.29 , Issue.5 , pp. 1034-1038
    • Taneri, S.1    Gerding, H.2
  • 83
    • 22044432277 scopus 로고    scopus 로고
    • Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit
    • Yamauchi Y, Franco L M, Jackson D J, Naber J F, Ziv R O, Rizzo J F, Kaplan H J and Enzmann V 2005 Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit J. Neural Eng. 2 S48-56
    • (2005) J. Neural Eng. , vol.2 , Issue.1
    • Yamauchi, Y.1    Franco, L.M.2    Jackson, D.J.3    Naber, J.F.4    Ziv, R.O.5    Rizzo, J.F.6    Kaplan, H.J.7    Enzmann, V.8
  • 84
    • 0000278932 scopus 로고    scopus 로고
    • The retina implant-project: In vitro and in vivo testing of different tack types for intraocular fixation of retina implants
    • Taneri S, Bollmann F P, Uhlig C, Thelen U and Gerding H 1999 The retina implant-project: in vitro and in vivo testing of different tack types for intraocular fixation of retina implants Invest. Ophthalmol. Vis. Sci. 40 733
    • (1999) Invest. Ophthalmol. Vis. Sci. , vol.40 , pp. 733
    • Taneri, S.1    Bollmann, F.P.2    Uhlig, C.3    Thelen, U.4    Gerding, H.5
  • 85
    • 0035527841 scopus 로고    scopus 로고
    • Successful long-term evaluation of intraocular titanium tacks for the mechanical stabilization of posterior segment ocular implants
    • Gerding H, Taneri S, Benner F P, Reichelt R, Thelen U and Uhlig C E 2001 Successful long-term evaluation of intraocular titanium tacks for the mechanical stabilization of posterior segment ocular implants Mater.wiss. Werkst.tech. 32 903-12
    • (2001) Mater.wiss. Werkst.tech. , vol.32 , Issue.12 , pp. 903-912
    • Gerding, H.1    Taneri, S.2    Benner, F.P.3    Reichelt, R.4    Thelen, U.5    Uhlig, C.E.6
  • 87
    • 22044457718 scopus 로고    scopus 로고
    • Tunable retina encoders for retina implants: Why and how
    • Eckmiller R, Neumann D and Baruth O 2005 Tunable retina encoders for retina implants: why and how J. Neural Eng. 2 S91-104
    • (2005) J. Neural Eng. , vol.2 , Issue.1 , pp. 91-104
    • Eckmiller, R.1    Neumann, D.2    Baruth, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.