메뉴 건너뛰기




Volumn 32, Issue 11, 2006, Pages 1031-1043

Rotary NiTi Instrument Fracture and its Consequences

Author keywords

Fracture; instrument design; instrumentation protocols; rotary nickel titanium instruments

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 33750008122     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2006.06.008     Document Type: Article
Times cited : (410)

References (174)
  • 1
    • 14644391417 scopus 로고    scopus 로고
    • Procedural accidents
    • Walton R., and Torabinejad M. (Eds), W.B. Saunders Company, Philadelphia
    • Torabinejad M., and Lemon R.R. Procedural accidents. In: Walton R., and Torabinejad M. (Eds). Principles and practice of endodontics (2002), W.B. Saunders Company, Philadelphia 310-330
    • (2002) Principles and practice of endodontics , pp. 310-330
    • Torabinejad, M.1    Lemon, R.R.2
  • 2
    • 0035409020 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after prolonged clinical use
    • Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 34 (2001) 386-389
    • (2001) Int Endod J , vol.34 , pp. 386-389
    • Gambarini, G.1
  • 3
    • 0014797447 scopus 로고
    • Relationship of broken root canal instruments to endodontic case prognosis: a clinical investigation
    • Crump M.C., and Natkin E. Relationship of broken root canal instruments to endodontic case prognosis: a clinical investigation. J Am Dent Assoc 80 (1970) 1341-1347
    • (1970) J Am Dent Assoc , vol.80 , pp. 1341-1347
    • Crump, M.C.1    Natkin, E.2
  • 4
    • 0347416962 scopus 로고    scopus 로고
    • Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo
    • Al-Fouzan K.S. Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo. Int Endod J 36 (2003) 864-867
    • (2003) Int Endod J , vol.36 , pp. 864-867
    • Al-Fouzan, K.S.1
  • 5
    • 2442680167 scopus 로고    scopus 로고
    • K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars
    • Ankrum M.T., Hartwell G.R., and Truitt J.E. K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars. J Endod 30 (2004) 234-237
    • (2004) J Endod , vol.30 , pp. 234-237
    • Ankrum, M.T.1    Hartwell, G.R.2    Truitt, J.E.3
  • 6
    • 1942439132 scopus 로고    scopus 로고
    • Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists
    • Parashos P., and Messer H.H. Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists. Int Endod J 37 (2004) 249-259
    • (2004) Int Endod J , vol.37 , pp. 249-259
    • Parashos, P.1    Messer, H.H.2
  • 7
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel-titanium endodontic instruments
    • Pruett J.P., Clement D.J., and Carnes Jr. D.L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23 (1997) 77-85
    • (1997) J Endod , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes Jr., D.L.3
  • 8
    • 0031151519 scopus 로고    scopus 로고
    • Instrument deterioration with usage: nickel-titanium versus stainless steel
    • Zuolo M.L., and Walton R.E. Instrument deterioration with usage: nickel-titanium versus stainless steel. Quint Int 28 (1997) 397-402
    • (1997) Quint Int , vol.28 , pp. 397-402
    • Zuolo, M.L.1    Walton, R.E.2
  • 9
    • 0033219289 scopus 로고    scopus 로고
    • Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage
    • Mandel E., Adib-Yazdi M., Benhamou L.-M., Lachkar T., Mesgouez C., and Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J 32 (1999) 436-443
    • (1999) Int Endod J , vol.32 , pp. 436-443
    • Mandel, E.1    Adib-Yazdi, M.2    Benhamou, L.-M.3    Lachkar, T.4    Mesgouez, C.5    Sobel, M.6
  • 10
    • 1542570495 scopus 로고    scopus 로고
    • Evaluation of single-use rotary nickel-titanium instruments
    • Arens F.C., Hoen M.M., Steiman H.R., and Dietz Jr. G.C. Evaluation of single-use rotary nickel-titanium instruments. J Endod 29 (2003) 664-666
    • (2003) J Endod , vol.29 , pp. 664-666
    • Arens, F.C.1    Hoen, M.M.2    Steiman, H.R.3    Dietz Jr., G.C.4
  • 11
    • 0033222799 scopus 로고    scopus 로고
    • Effect of rotational speed on nickel-titanium file distortion
    • Gabel W.P., Hoen M., Steiman H.R., Pink F.E., and Dietz R. Effect of rotational speed on nickel-titanium file distortion. J Endod 25 (1999) 752-754
    • (1999) J Endod , vol.25 , pp. 752-754
    • Gabel, W.P.1    Hoen, M.2    Steiman, H.R.3    Pink, F.E.4    Dietz, R.5
  • 12
    • 0034189130 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after clinical use
    • Yared G.M., Bou Dagher F.E., and Machtou P. Cyclic fatigue of ProFile rotary instruments after clinical use. Int Endod J 33 (2000) 204-207
    • (2000) Int Endod J , vol.33 , pp. 204-207
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3
  • 13
    • 5444247733 scopus 로고    scopus 로고
    • Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use
    • Parashos P., Gordon I., and Messer H.H. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. J Endod 30 (2004) 722-725
    • (2004) J Endod , vol.30 , pp. 722-725
    • Parashos, P.1    Gordon, I.2    Messer, H.H.3
  • 14
    • 1542786387 scopus 로고    scopus 로고
    • Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study
    • Ward J.R., Parashos P., and Messer H.H. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study. J Endod 29 (2003) 756-763
    • (2003) J Endod , vol.29 , pp. 756-763
    • Ward, J.R.1    Parashos, P.2    Messer, H.H.3
  • 15
    • 1542786390 scopus 로고    scopus 로고
    • Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases
    • Ward J.R., Parashos P., and Messer H.H. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases. J Endod 29 (2003) 764-767
    • (2003) J Endod , vol.29 , pp. 764-767
    • Ward, J.R.1    Parashos, P.2    Messer, H.H.3
  • 16
    • 33644536464 scopus 로고    scopus 로고
    • The diffusion of innovation in dentistry: a review using rotary nickel-titanium technology as an example
    • Parashos P., and Messer H.H. The diffusion of innovation in dentistry: a review using rotary nickel-titanium technology as an example. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101 (2006) 395-401
    • (2006) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.101 , pp. 395-401
    • Parashos, P.1    Messer, H.H.2
  • 17
    • 17144448593 scopus 로고    scopus 로고
    • Comparative study of root-canal preparation using Lightspeed and Quantec SC rotary NiTi instruments
    • Hülsmann M., Herbst U., and Schäfers F. Comparative study of root-canal preparation using Lightspeed and Quantec SC rotary NiTi instruments. Int Endod J 36 (2003) 748-756
    • (2003) Int Endod J , vol.36 , pp. 748-756
    • Hülsmann, M.1    Herbst, U.2    Schäfers, F.3
  • 18
    • 0034157078 scopus 로고    scopus 로고
    • Defects in rotary nickel-titanium files after clinical use
    • Sattapan B., Nervo G.J., Palamara J.E.A., and Messer H.H. Defects in rotary nickel-titanium files after clinical use. J Endod 26 (2000) 161-165
    • (2000) J Endod , vol.26 , pp. 161-165
    • Sattapan, B.1    Nervo, G.J.2    Palamara, J.E.A.3    Messer, H.H.4
  • 19
    • 12344257590 scopus 로고    scopus 로고
    • SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31 (2005) 40-43
    • (2005) J Endod , vol.31 , pp. 40-43
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 20
    • 0011894636 scopus 로고
    • The dependence of the results of pulp therapy on certain factors. An analytic study based on radiographic and clinical follow-up examinations
    • Strindberg L.Z. The dependence of the results of pulp therapy on certain factors. An analytic study based on radiographic and clinical follow-up examinations. Acta Odontol Scand 14 (1956) 1-175
    • (1956) Acta Odontol Scand , vol.14 , pp. 1-175
    • Strindberg, L.Z.1
  • 21
    • 0040868678 scopus 로고
    • Correlation of positive cultures with the prognosis for root canal treatment
    • Engström B., Hård L., Segerstad A.F., Ramström G., and Frostell G. Correlation of positive cultures with the prognosis for root canal treatment. Odontol Revy 15 (1964) 257-270
    • (1964) Odontol Revy , vol.15 , pp. 257-270
    • Engström, B.1    Hård, L.2    Segerstad, A.F.3    Ramström, G.4    Frostell, G.5
  • 22
    • 0013832352 scopus 로고
    • Correlation between positive culture and the prognosis of root canal therapy after pulpectomy
    • Engström B., and Lundberg M. Correlation between positive culture and the prognosis of root canal therapy after pulpectomy. Odontol Revy 16 (1965) 193-203
    • (1965) Odontol Revy , vol.16 , pp. 193-203
    • Engström, B.1    Lundberg, M.2
  • 24
    • 0018439391 scopus 로고
    • Long-term results of endodontic treatment performed with a standardized technique
    • Kerekes K., and Tronstad L. Long-term results of endodontic treatment performed with a standardized technique. J Endod 5 (1979) 83-90
    • (1979) J Endod , vol.5 , pp. 83-90
    • Kerekes, K.1    Tronstad, L.2
  • 25
    • 0020018102 scopus 로고
    • Failures and healing in endodontically treated non-vital anterior teeth with posttraumatically reduced pulpal lumen
    • Cvek M., Granath L., and Lundberg M. Failures and healing in endodontically treated non-vital anterior teeth with posttraumatically reduced pulpal lumen. Acta Odontol Scand 40 (1982) 223-228
    • (1982) Acta Odontol Scand , vol.40 , pp. 223-228
    • Cvek, M.1    Granath, L.2    Lundberg, M.3
  • 26
    • 0025504897 scopus 로고
    • Factors affecting the long-term results of endodontic treatment
    • Sjögren U., Häggeland B., Sundqvist G., and Wing K. Factors affecting the long-term results of endodontic treatment. J Endod 16 (1990) 498-504
    • (1990) J Endod , vol.16 , pp. 498-504
    • Sjögren, U.1    Häggeland, B.2    Sundqvist, G.3    Wing, K.4
  • 27
    • 0025405676 scopus 로고
    • A systematic approach to preventing intracanal breakage of endodontic files
    • Sotokawa T. A systematic approach to preventing intracanal breakage of endodontic files. Endod Dent Traumatol 6 (1990) 60-62
    • (1990) Endod Dent Traumatol , vol.6 , pp. 60-62
    • Sotokawa, T.1
  • 28
    • 28144444315 scopus 로고    scopus 로고
    • Procedural errors with the use of nickel-titanium rotary instruments in undergraduate endodontics
    • [abstract PR 24]
    • Pettiette M.T., Conner D., and Trope M. Procedural errors with the use of nickel-titanium rotary instruments in undergraduate endodontics. J Endod 28 (2002) 259 [abstract PR 24]
    • (2002) J Endod , vol.28 , pp. 259
    • Pettiette, M.T.1    Conner, D.2    Trope, M.3
  • 29
    • 0036519309 scopus 로고    scopus 로고
    • Radiographic evaluation of the prevalence and technical quality of root canal treatment in a French subpopulation
    • Boucher Y., Matossian L., Rilliard F., and Machtou P. Radiographic evaluation of the prevalence and technical quality of root canal treatment in a French subpopulation. Int Endod J 35 (2002) 229-238
    • (2002) Int Endod J , vol.35 , pp. 229-238
    • Boucher, Y.1    Matossian, L.2    Rilliard, F.3    Machtou, P.4
  • 30
    • 33644523499 scopus 로고    scopus 로고
    • A retrospective clinical study of incidence of root canal instrument separation in an endodontic graduate program
    • [abstract OR 29].
    • Kohli M., Kim J., Iqbal M., and Kim S. A retrospective clinical study of incidence of root canal instrument separation in an endodontic graduate program. J Endod 31 (2005) 223 [abstract OR 29].
    • (2005) J Endod , vol.31 , pp. 223
    • Kohli, M.1    Kim, J.2    Iqbal, M.3    Kim, S.4
  • 31
    • 28144462444 scopus 로고    scopus 로고
    • The impact of instrument fracture on outcome of endodontic treatment
    • Spili P., Parashos P., and Messer H.H. The impact of instrument fracture on outcome of endodontic treatment. J Endod 31 (2005) 845-850
    • (2005) J Endod , vol.31 , pp. 845-850
    • Spili, P.1    Parashos, P.2    Messer, H.H.3
  • 33
    • 3042563899 scopus 로고    scopus 로고
    • Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study
    • Schäfer E., Schulz-Bongert U., and Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. J Endod 30 (2004) 432-435
    • (2004) J Endod , vol.30 , pp. 432-435
    • Schäfer, E.1    Schulz-Bongert, U.2    Tulus, G.3
  • 34
    • 33750025004 scopus 로고    scopus 로고
    • Clinical incidence of endodontically treated teeth with non-retrievable rotary files
    • (Spec Iss A):abstract 1564
    • Leseberg D.A., Knowles K., and Hammond N. Clinical incidence of endodontically treated teeth with non-retrievable rotary files. J Dent Res 84 (2005) (Spec Iss A):abstract 1564
    • (2005) J Dent Res , vol.84
    • Leseberg, D.A.1    Knowles, K.2    Hammond, N.3
  • 35
    • 0030621990 scopus 로고    scopus 로고
    • The Lightspeed preparation technique evaluated by Swiss clinicians after attending continuing education courses
    • Barbakow F., and Lutz F. The Lightspeed preparation technique evaluated by Swiss clinicians after attending continuing education courses. Int Endod J 30 (1997) 46-50
    • (1997) Int Endod J , vol.30 , pp. 46-50
    • Barbakow, F.1    Lutz, F.2
  • 36
    • 0036366281 scopus 로고    scopus 로고
    • Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files
    • Yared G.M., Bou Dagher F.E., Machtou P., and Kulkarni G.K. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. Int Endod J 35 (2002) 7-12
    • (2002) Int Endod J , vol.35 , pp. 7-12
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3    Kulkarni, G.K.4
  • 37
    • 0242636753 scopus 로고    scopus 로고
    • Root-canal shaping with manual and rotary Ni-Ti files performed by students
    • Sonntag D., Delschen S., and Stachniss V. Root-canal shaping with manual and rotary Ni-Ti files performed by students. Int Endod J 36 (2003) 715-723
    • (2003) Int Endod J , vol.36 , pp. 715-723
    • Sonntag, D.1    Delschen, S.2    Stachniss, V.3
  • 38
    • 0037711260 scopus 로고    scopus 로고
    • Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals
    • Mesgouez C., Rilliard F., Matossian L., Nassiri K., and Mandel E. Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals. Int Endod J 36 (2003) 161-165
    • (2003) Int Endod J , vol.36 , pp. 161-165
    • Mesgouez, C.1    Rilliard, F.2    Matossian, L.3    Nassiri, K.4    Mandel, E.5
  • 39
    • 2442718800 scopus 로고    scopus 로고
    • Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments
    • Berutti E., Negro A.R., Lendini M., and Pasqualini D. Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod 30 (2004) 228-230
    • (2004) J Endod , vol.30 , pp. 228-230
    • Berutti, E.1    Negro, A.R.2    Lendini, M.3    Pasqualini, D.4
  • 40
    • 33645101292 scopus 로고    scopus 로고
    • Mechanical preparation of root canals: shaping goals, techniques and means
    • Hülsmann M., Peters O.A., and Dummer P.M.H. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 10 (2005) 30-76
    • (2005) Endod Topics , vol.10 , pp. 30-76
    • Hülsmann, M.1    Peters, O.A.2    Dummer, P.M.H.3
  • 43
    • 0034231421 scopus 로고    scopus 로고
    • An overview of nickel-titanium alloys used in dentistry
    • Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 (2000) 297-310
    • (2000) Int Endod J , vol.33 , pp. 297-310
    • Thompson, S.A.1
  • 47
    • 33750018846 scopus 로고    scopus 로고
    • Fractographic analysis of experimentally separated NiTi rotary files
    • (Abs OR15)
    • Karn T.A., Kelly J.R., and Spångberg L. Fractographic analysis of experimentally separated NiTi rotary files. J Endod 29 (2003) 288 (Abs OR15)
    • (2003) J Endod , vol.29 , pp. 288
    • Karn, T.A.1    Kelly, J.R.2    Spångberg, L.3
  • 48
    • 0346156362 scopus 로고
    • Failure mechanisms and metallography: a review
    • McCall J., and French P. (Eds), Plenum Press, New York
    • LeMay I. Failure mechanisms and metallography: a review. In: McCall J., and French P. (Eds). Metallography in failure analysis (1978), Plenum Press, New York 1-31
    • (1978) Metallography in failure analysis , pp. 1-31
    • LeMay, I.1
  • 49
    • 0030320541 scopus 로고    scopus 로고
    • Torsional testing of the Lightspeed nickel-titanium instrument system
    • Marsicovetere E.S., Burgess J.O., Clement D.J., and del Rio C.E. Torsional testing of the Lightspeed nickel-titanium instrument system. J Endod 22 (1996) 681-684
    • (1996) J Endod , vol.22 , pp. 681-684
    • Marsicovetere, E.S.1    Burgess, J.O.2    Clement, D.J.3    del Rio, C.E.4
  • 50
    • 0034296268 scopus 로고    scopus 로고
    • A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsion and bending tests
    • Kazemi R.B., Stenman E., and Spångberg L.S. A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsion and bending tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 90 (2000) 500-506
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.90 , pp. 500-506
    • Kazemi, R.B.1    Stenman, E.2    Spångberg, L.S.3
  • 52
    • 0036835346 scopus 로고    scopus 로고
    • Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments
    • Chaves Craveiro de Melo M., Guiomar de Azevedo Bahia M., and Buono V. Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments. J Endod 28 (2002) 765-769
    • (2002) J Endod , vol.28 , pp. 765-769
    • Chaves Craveiro de Melo, M.1    Guiomar de Azevedo Bahia, M.2    Buono, V.3
  • 53
    • 22544455071 scopus 로고    scopus 로고
    • Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals
    • Bahia M., and Buono V. Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 100 (2005) 249-255
    • (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.100 , pp. 249-255
    • Bahia, M.1    Buono, V.2
  • 54
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haïkel Y., Serfaty R., Bateman G., Senger B., and Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haïkel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allemann, C.5
  • 55
    • 22544487199 scopus 로고    scopus 로고
    • Defects in ProTaper S1 instruments after clinical use: longitudinal examination
    • Peng B., Shen Y., Cheung G.S., and Xia T.J. Defects in ProTaper S1 instruments after clinical use: longitudinal examination. Int Endod J 38 (2005) 550-557
    • (2005) Int Endod J , vol.38 , pp. 550-557
    • Peng, B.1    Shen, Y.2    Cheung, G.S.3    Xia, T.J.4
  • 56
    • 22544438540 scopus 로고    scopus 로고
    • Defects in ProTaper S1 instruments after clinical use: fractographic examination
    • Cheung G.S.P., Peng B., Bian Z., Shen Y., and Darvell B.W. Defects in ProTaper S1 instruments after clinical use: fractographic examination. Int Endod J 38 (2005) 802-809
    • (2005) Int Endod J , vol.38 , pp. 802-809
    • Cheung, G.S.P.1    Peng, B.2    Bian, Z.3    Shen, Y.4    Darvell, B.W.5
  • 57
    • 33644645409 scopus 로고    scopus 로고
    • Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: fractographic analysis
    • Spanaki-Voreadi A., Kerezoudis N., and Zinelis S. Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: fractographic analysis. Int Endod J 39 (2006) 171-178
    • (2006) Int Endod J , vol.39 , pp. 171-178
    • Spanaki-Voreadi, A.1    Kerezoudis, N.2    Zinelis, S.3
  • 58
    • 0034157104 scopus 로고    scopus 로고
    • Torque during canal instrumentation using rotary nickel-titanium files
    • Sattapan B., Palamara J.E.A., and Messer H.H. Torque during canal instrumentation using rotary nickel-titanium files. J Endod 26 (2000) 156-160
    • (2000) J Endod , vol.26 , pp. 156-160
    • Sattapan, B.1    Palamara, J.E.A.2    Messer, H.H.3
  • 59
    • 14944376564 scopus 로고    scopus 로고
    • Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
    • Ullmann C.J., and Peters O.A. Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments. J Endod 31 (2005) 183-186
    • (2005) J Endod , vol.31 , pp. 183-186
    • Ullmann, C.J.1    Peters, O.A.2
  • 60
    • 33645104462 scopus 로고    scopus 로고
    • Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments
    • Miyai K., Ebihara A., Hayashi Y., Doi H., Suda H., and Yoneyama T. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments. Int Endod J 39 (2006) 119-126
    • (2006) Int Endod J , vol.39 , pp. 119-126
    • Miyai, K.1    Ebihara, A.2    Hayashi, Y.3    Doi, H.4    Suda, H.5    Yoneyama, T.6
  • 61
    • 0242551960 scopus 로고    scopus 로고
    • An in vitro study of the torsional properties of new and used K3 instruments
    • Yared G., Kulkarni G.K., and Ghossayn F. An in vitro study of the torsional properties of new and used K3 instruments. Int Endod J 36 (2003) 764-769
    • (2003) Int Endod J , vol.36 , pp. 764-769
    • Yared, G.1    Kulkarni, G.K.2    Ghossayn, F.3
  • 62
    • 20444489249 scopus 로고    scopus 로고
    • A comparison of torque required to fracture rotary files with tips bound in simulated curved canal
    • Guilford W.L., Lemons J.E., and Eleazer P.D. A comparison of torque required to fracture rotary files with tips bound in simulated curved canal. J Endod 31 (2005) 468-470
    • (2005) J Endod , vol.31 , pp. 468-470
    • Guilford, W.L.1    Lemons, J.E.2    Eleazer, P.D.3
  • 63
    • 0034230985 scopus 로고    scopus 로고
    • Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models
    • Turpin Y.L., Chagneau F., and Vulcain J.M. Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models. J Endod 26 (2000) 414-417
    • (2000) J Endod , vol.26 , pp. 414-417
    • Turpin, Y.L.1    Chagneau, F.2    Vulcain, J.M.3
  • 64
    • 0038137043 scopus 로고    scopus 로고
    • Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary models: ProTaper versus ProFile
    • Berutti E., Chiandussi G., Gaviglio I., and Ibba A. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary models: ProTaper versus ProFile. J Endod 29 (2003) 15-19
    • (2003) J Endod , vol.29 , pp. 15-19
    • Berutti, E.1    Chiandussi, G.2    Gaviglio, I.3    Ibba, A.4
  • 66
    • 5444255471 scopus 로고    scopus 로고
    • Effect of pitch length on the behavior of rotary triple helix root canal instruments
    • Diemer F., and Calas P. Effect of pitch length on the behavior of rotary triple helix root canal instruments. J Endod 30 (2004) 716-718
    • (2004) J Endod , vol.30 , pp. 716-718
    • Diemer, F.1    Calas, P.2
  • 67
    • 3042566864 scopus 로고    scopus 로고
    • Morphometric analysis of shank-to-flute ratio in rotary nickel-titanium files
    • Biz M.T., and Figueiredo J.A.P. Morphometric analysis of shank-to-flute ratio in rotary nickel-titanium files. Int Endod J 37 (2004) 353-358
    • (2004) Int Endod J , vol.37 , pp. 353-358
    • Biz, M.T.1    Figueiredo, J.A.P.2
  • 69
    • 0030138445 scopus 로고    scopus 로고
    • Morphometric video analysis of the engine-driven nickel-titanium Lightspeed instrument system
    • Marsicovetere E.S., Clement D.J., and Del Rio C.E. Morphometric video analysis of the engine-driven nickel-titanium Lightspeed instrument system. J Endod 22 (1996) 231-235
    • (1996) J Endod , vol.22 , pp. 231-235
    • Marsicovetere, E.S.1    Clement, D.J.2    Del Rio, C.E.3
  • 70
    • 10644241579 scopus 로고    scopus 로고
    • Factors affecting the outcome of orthograde root canal therapy in a general dentistry hospital practice
    • Marending M., Peters O.A., and Zehnder M. Factors affecting the outcome of orthograde root canal therapy in a general dentistry hospital practice. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 99 (2005) 119-124
    • (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.99 , pp. 119-124
    • Marending, M.1    Peters, O.A.2    Zehnder, M.3
  • 71
    • 0033154787 scopus 로고    scopus 로고
    • Wear of nickel-titanium Lightspeed instruments evaluated by scanning electron microscopy
    • Eggert C., Peters O., and Barbakow F. Wear of nickel-titanium Lightspeed instruments evaluated by scanning electron microscopy. J Endod 25 (1999) 494-497
    • (1999) J Endod , vol.25 , pp. 494-497
    • Eggert, C.1    Peters, O.2    Barbakow, F.3
  • 72
    • 0035432084 scopus 로고    scopus 로고
    • Influence of structure on nickel-titanium endodontic instruments failure
    • Kuhn G., Tavernier B., and Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endod 27 (2001) 516-520
    • (2001) J Endod , vol.27 , pp. 516-520
    • Kuhn, G.1    Tavernier, B.2    Jordan, L.3
  • 74
    • 1542465898 scopus 로고    scopus 로고
    • Scanning electron microscope observations of new and used nickel-titanium rotary files
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., and Mitchell J.C. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod 29 (2003) 667-669
    • (2003) J Endod , vol.29 , pp. 667-669
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Mitchell, J.C.5
  • 75
    • 2442680173 scopus 로고    scopus 로고
    • Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments. J Endod 30 (2004) 339-341
    • (2004) J Endod , vol.30 , pp. 339-341
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 76
    • 28144457998 scopus 로고    scopus 로고
    • Atomic force microscopy study of stainless steel and nickel-titanium files
    • Valois C.R.A., Silva L.P., and Azevedo R.B. Atomic force microscopy study of stainless steel and nickel-titanium files. J Endod 31 (2005) 882-885
    • (2005) J Endod , vol.31 , pp. 882-885
    • Valois, C.R.A.1    Silva, L.P.2    Azevedo, R.B.3
  • 77
    • 0029313146 scopus 로고
    • Effectiveness of ultrasonic cleaning of dental instruments
    • Cafruny W., Brunick A., Nelson D.M., and Nelson R.F. Effectiveness of ultrasonic cleaning of dental instruments. Am J Dent 8 (1995) 152-156
    • (1995) Am J Dent , vol.8 , pp. 152-156
    • Cafruny, W.1    Brunick, A.2    Nelson, D.M.3    Nelson, R.F.4
  • 78
    • 4944238010 scopus 로고    scopus 로고
    • An SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures
    • Van Eldik D.A., Zilm P.S., Rogers A.H., and Marin P.D. An SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures. Aust Dent J 49 (2004) 128-135
    • (2004) Aust Dent J , vol.49 , pp. 128-135
    • Van Eldik, D.A.1    Zilm, P.S.2    Rogers, A.H.3    Marin, P.D.4
  • 79
    • 0842333861 scopus 로고    scopus 로고
    • Cleaning of rotary nickel-titanium endodontic instruments
    • Linsuwanont P., Parashos P., and Messer H.H. Cleaning of rotary nickel-titanium endodontic instruments. Int Endod J 37 (2004) 19-28
    • (2004) Int Endod J , vol.37 , pp. 19-28
    • Linsuwanont, P.1    Parashos, P.2    Messer, H.H.3
  • 80
    • 1842633762 scopus 로고    scopus 로고
    • A cleaning protocol for rotary nickel-titanium endodontic instruments
    • Parashos P., Linsuwanont P., and Messer H.H. A cleaning protocol for rotary nickel-titanium endodontic instruments. Aust Dent J 49 (2004) 20-27
    • (2004) Aust Dent J , vol.49 , pp. 20-27
    • Parashos, P.1    Linsuwanont, P.2    Messer, H.H.3
  • 81
    • 0036777233 scopus 로고    scopus 로고
    • Surface analysis of ProFile instruments by scanning electron microscopy and X-ray energy-dispersive spectroscopy: a preliminary study
    • Martins R., Bahia M., and Buono V. Surface analysis of ProFile instruments by scanning electron microscopy and X-ray energy-dispersive spectroscopy: a preliminary study. Int Endod J 35 (2002) 848-853
    • (2002) Int Endod J , vol.35 , pp. 848-853
    • Martins, R.1    Bahia, M.2    Buono, V.3
  • 82
    • 0036777866 scopus 로고    scopus 로고
    • Fatigue and mechanical properties of nickel-titanium endodontic instruments
    • Kuhn G., and Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endod 28 (2002) 716-720
    • (2002) J Endod , vol.28 , pp. 716-720
    • Kuhn, G.1    Jordan, L.2
  • 83
    • 33750025281 scopus 로고    scopus 로고
    • Surface integrity
    • Crookall J., Shaw M., and Suh N. (Eds), Oxford University Press, New York
    • Shaw M. Surface integrity. In: Crookall J., Shaw M., and Suh N. (Eds). Metal cutting principles. 2nd ed. (2005), Oxford University Press, New York 472-478
    • (2005) Metal cutting principles. 2nd ed. , pp. 472-478
    • Shaw, M.1
  • 84
    • 0035458398 scopus 로고    scopus 로고
    • Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation
    • Rapisarda E., Bonaccorso A., Tripi T.R., Condorelli G.G., and Torrisi L. Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. J Endod 27 (2001) 588-592
    • (2001) J Endod , vol.27 , pp. 588-592
    • Rapisarda, E.1    Bonaccorso, A.2    Tripi, T.R.3    Condorelli, G.G.4    Torrisi, L.5
  • 85
    • 0030253003 scopus 로고    scopus 로고
    • Enhanced surface hardness by boron implantation in Nitinol alloy
    • Lee D.H., Park B., Saxena A., and Serene T.P. Enhanced surface hardness by boron implantation in Nitinol alloy. J Endod 22 (1996) 543-546
    • (1996) J Endod , vol.22 , pp. 543-546
    • Lee, D.H.1    Park, B.2    Saxena, A.3    Serene, T.P.4
  • 86
    • 0036885793 scopus 로고    scopus 로고
    • Effect of physical vapor deposition on cutting efficiency of nickel-titanium files
    • Schäfer E. Effect of physical vapor deposition on cutting efficiency of nickel-titanium files. J Endod 28 (2002) 800-802
    • (2002) J Endod , vol.28 , pp. 800-802
    • Schäfer, E.1
  • 87
    • 0036778212 scopus 로고    scopus 로고
    • Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments
    • Schäfer E. Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments. Int Endod J 35 (2002) 867-872
    • (2002) Int Endod J , vol.35 , pp. 867-872
    • Schäfer, E.1
  • 88
    • 0038147283 scopus 로고    scopus 로고
    • Fabrication of hard coatings on NiTi instruments
    • Tripi T.R., Bonaccorso A., and Condorelli G.G. Fabrication of hard coatings on NiTi instruments. J Endod 29 (2003) 132-134
    • (2003) J Endod , vol.29 , pp. 132-134
    • Tripi, T.R.1    Bonaccorso, A.2    Condorelli, G.G.3
  • 89
    • 21044432502 scopus 로고    scopus 로고
    • Effect of cryogenic treatment on nickel-titanium endodontic instruments
    • Kim J.W., Griggs J.A., Regan J.D., Ellis R.A., and Cai Z. Effect of cryogenic treatment on nickel-titanium endodontic instruments. Int Endod J 38 (2005) 364-371
    • (2005) Int Endod J , vol.38 , pp. 364-371
    • Kim, J.W.1    Griggs, J.A.2    Regan, J.D.3    Ellis, R.A.4    Cai, Z.5
  • 90
    • 0042910422 scopus 로고    scopus 로고
    • Mechanical, thermal, chemical and electrochemical surface treatment of titanium
    • Brunette D.M., Tengvall P., Textor M., and Thomsen P. (Eds), Springer, Berlin
    • Lausmaa J. Mechanical, thermal, chemical and electrochemical surface treatment of titanium. In: Brunette D.M., Tengvall P., Textor M., and Thomsen P. (Eds). Titanium in medicine. 1st ed. (2001), Springer, Berlin 247-248
    • (2001) Titanium in medicine. 1st ed. , pp. 247-248
    • Lausmaa, J.1
  • 91
    • 3042785502 scopus 로고    scopus 로고
    • Electrolytic processing of NiTi shape memory alloys
    • Pohl M., Heβing C., and Frenzal J. Electrolytic processing of NiTi shape memory alloys. Mater Sci Engineer 378 (2004) 191-199
    • (2004) Mater Sci Engineer , vol.378 , pp. 191-199
    • Pohl, M.1    Heßing, C.2    Frenzal, J.3
  • 92
    • 0036597338 scopus 로고    scopus 로고
    • Cyclic fatigue of endodontic nickel-titanium rotary instruments: static and dynamic tests
    • Li U.M., Lee B.S., Shih C.T., Lan W.H., and Lin C.P. Cyclic fatigue of endodontic nickel-titanium rotary instruments: static and dynamic tests. J Endod 28 (2002) 448-451
    • (2002) J Endod , vol.28 , pp. 448-451
    • Li, U.M.1    Lee, B.S.2    Shih, C.T.3    Lan, W.H.4    Lin, C.P.5
  • 93
    • 0036635798 scopus 로고    scopus 로고
    • The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments
    • Zelada G., Varela P., Martín B., Bahíllo J.G., Magán F., and Ahn S. The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. J Endod 28 (2002) 540-542
    • (2002) J Endod , vol.28 , pp. 540-542
    • Zelada, G.1    Varela, P.2    Martín, B.3    Bahíllo, J.G.4    Magán, F.5    Ahn, S.6
  • 94
    • 0042730176 scopus 로고    scopus 로고
    • Factors influencing the fracture of nickel-titanium rotary instruments
    • Martín B., Zelada G., Varela P., et al. Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J 36 (2003) 262-266
    • (2003) Int Endod J , vol.36 , pp. 262-266
    • Martín, B.1    Zelada, G.2    Varela, P.3
  • 95
    • 0029439707 scopus 로고
    • Effect of nickel-titanium engine driven instrument rotational speed on root canal morphology
    • Poulsen W.B., Dove S.B., and Del Rio C.E. Effect of nickel-titanium engine driven instrument rotational speed on root canal morphology. J Endod 21 (1995) 609-612
    • (1995) J Endod , vol.21 , pp. 609-612
    • Poulsen, W.B.1    Dove, S.B.2    Del Rio, C.E.3
  • 96
    • 0034139354 scopus 로고    scopus 로고
    • Effect of rotational speed on the breakage of nickel-titanium rotary files
    • Dietz D.B., Di Fiore P.M., Bahcall J.K., and Lautenschlager E.P. Effect of rotational speed on the breakage of nickel-titanium rotary files. J Endod 26 (1998) 68-71
    • (1998) J Endod , vol.26 , pp. 68-71
    • Dietz, D.B.1    Di Fiore, P.M.2    Bahcall, J.K.3    Lautenschlager, E.P.4
  • 97
    • 0035221977 scopus 로고    scopus 로고
    • Influence of rotational speed, torque, and operator's proficiency on ProFile failures
    • Yared G., Bou Dagher F., and Machtou P. Influence of rotational speed, torque, and operator's proficiency on ProFile failures. Int Endod J 34 (2001) 47-53
    • (2001) Int Endod J , vol.34 , pp. 47-53
    • Yared, G.1    Bou Dagher, F.2    Machtou, P.3
  • 98
    • 0035236243 scopus 로고    scopus 로고
    • Comparison of nickel-titanium file distortion using electric and air-driven handpieces
    • Bortnick K.L., Steiman H.R., and Ruskin A. Comparison of nickel-titanium file distortion using electric and air-driven handpieces. J Endod 27 (2001) 57-59
    • (2001) J Endod , vol.27 , pp. 57-59
    • Bortnick, K.L.1    Steiman, H.R.2    Ruskin, A.3
  • 99
    • 0035656334 scopus 로고    scopus 로고
    • Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors
    • Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 27 (2001) 772-774
    • (2001) J Endod , vol.27 , pp. 772-774
    • Gambarini, G.1
  • 100
    • 27644531935 scopus 로고    scopus 로고
    • Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments
    • Bahia M.G.A., Martins R.C., Gonzalez B.M., and Buono V.T.L. Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments. Int Endod J 38 (2005) 795-801
    • (2005) Int Endod J , vol.38 , pp. 795-801
    • Bahia, M.G.A.1    Martins, R.C.2    Gonzalez, B.M.3    Buono, V.T.L.4
  • 101
    • 0036363074 scopus 로고    scopus 로고
    • Failure of ProFile instruments used with air, high torque control, and low torque control motors
    • Yared G., and Sleiman P. Failure of ProFile instruments used with air, high torque control, and low torque control motors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 93 (2002) 92-96
    • (2002) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.93 , pp. 92-96
    • Yared, G.1    Sleiman, P.2
  • 102
    • 1942485356 scopus 로고    scopus 로고
    • Accuracy of the Nouvag torque control motor for nickel-titanium rotary instruments
    • Yared G., and Kulkarni G.K. Accuracy of the Nouvag torque control motor for nickel-titanium rotary instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 97 (2004) 499-501
    • (2004) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.97 , pp. 499-501
    • Yared, G.1    Kulkarni, G.K.2
  • 103
    • 3042660033 scopus 로고    scopus 로고
    • Accuracy of the DTC torque control motor for nickel-titanium rotary instruments
    • Yared G., and Kulkarni G.K. Accuracy of the DTC torque control motor for nickel-titanium rotary instruments. Int Endod J 37 (2004) 399-402
    • (2004) Int Endod J , vol.37 , pp. 399-402
    • Yared, G.1    Kulkarni, G.K.2
  • 104
    • 4544229686 scopus 로고    scopus 로고
    • Accuracy of the TCM Endo III torque-control motor for nickel-titanium rotary instruments
    • Yared G., and Kulkarni G.K. Accuracy of the TCM Endo III torque-control motor for nickel-titanium rotary instruments. J Endod 30 (2004) 644-645
    • (2004) J Endod , vol.30 , pp. 644-645
    • Yared, G.1    Kulkarni, G.K.2
  • 105
    • 0037799338 scopus 로고    scopus 로고
    • A comparison of torque required to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip
    • Booth J.R., Scheetz J.P., Lemons J.E., and Eleazer P.D. A comparison of torque required to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip. J Endod 29 (2003) 55-57
    • (2003) J Endod , vol.29 , pp. 55-57
    • Booth, J.R.1    Scheetz, J.P.2    Lemons, J.E.3    Eleazer, P.D.4
  • 106
    • 3042658179 scopus 로고    scopus 로고
    • Torsional fatigue and endurance limit of a size 30 .06 ProFile rotary instrument
    • Best S., Watson P., Pilliar R., Kulkarni G.G.K., and Yared G. Torsional fatigue and endurance limit of a size 30 .06 ProFile rotary instrument. Int Endod J 37 (2004) 370-373
    • (2004) Int Endod J , vol.37 , pp. 370-373
    • Best, S.1    Watson, P.2    Pilliar, R.3    Kulkarni, G.G.K.4    Yared, G.5
  • 107
    • 0038146983 scopus 로고    scopus 로고
    • ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy
    • Peters O.A., Peters C.I., Schönenberger K., and Barbakow F. ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy. Int Endod J 36 (2003) 93-99
    • (2003) Int Endod J , vol.36 , pp. 93-99
    • Peters, O.A.1    Peters, C.I.2    Schönenberger, K.3    Barbakow, F.4
  • 108
    • 33745835366 scopus 로고    scopus 로고
    • Root canal morphology and its relationship to endodontic procedures
    • Vertucci F.J. Root canal morphology and its relationship to endodontic procedures. Endod Topics 10 (2005) 3-29
    • (2005) Endod Topics , vol.10 , pp. 3-29
    • Vertucci, F.J.1
  • 109
    • 33750008365 scopus 로고    scopus 로고
    • ProSystem GT design, technique, and advantages
    • Buchanan L.S. ProSystem GT design, technique, and advantages. Endod Topics 10 (2005) 168-175
    • (2005) Endod Topics , vol.10 , pp. 168-175
    • Buchanan, L.S.1
  • 110
    • 0032610007 scopus 로고    scopus 로고
    • Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments
    • Blum J.Y., Cohen A., Machtou P., and Micallef J.P. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments. Int Endod J 32 (1999) 24-31
    • (1999) Int Endod J , vol.32 , pp. 24-31
    • Blum, J.Y.1    Cohen, A.2    Machtou, P.3    Micallef, J.P.4
  • 111
    • 13544267420 scopus 로고    scopus 로고
    • Analysis of torque and force with differently tapered rotary endodontic instruments in vitro
    • Schrader C., and Peters O.A. Analysis of torque and force with differently tapered rotary endodontic instruments in vitro. J Endod 31 (2005) 120-123
    • (2005) J Endod , vol.31 , pp. 120-123
    • Schrader, C.1    Peters, O.A.2
  • 112
    • 0034189555 scopus 로고    scopus 로고
    • Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: part 1
    • Thompson S.A., and Dummer P.M. Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: part 1. Int Endod J 33 (2000) 248-254
    • (2000) Int Endod J , vol.33 , pp. 248-254
    • Thompson, S.A.1    Dummer, P.M.2
  • 113
    • 0034189723 scopus 로고    scopus 로고
    • Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: part 2
    • Thompson S.A., and Dummer P.M. Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: part 2. Int Endod J 33 (2000) 255-261
    • (2000) Int Endod J , vol.33 , pp. 255-261
    • Thompson, S.A.1    Dummer, P.M.2
  • 114
    • 12144272582 scopus 로고    scopus 로고
    • Analysis of forces developed during mechanical preparation of extracted teeth using RaCe rotary instruments and ProFiles
    • da Silva F.M., Kobayashi C., and Suda H. Analysis of forces developed during mechanical preparation of extracted teeth using RaCe rotary instruments and ProFiles. Int Endod J 38 (2005) 17-21
    • (2005) Int Endod J , vol.38 , pp. 17-21
    • da Silva, F.M.1    Kobayashi, C.2    Suda, H.3
  • 115
    • 0036715745 scopus 로고    scopus 로고
    • The effect of instrument type and preflaring on apical file size determination
    • Tan B.T., and Messer H.H. The effect of instrument type and preflaring on apical file size determination. Int Endod J 35 (2002) 752-758
    • (2002) Int Endod J , vol.35 , pp. 752-758
    • Tan, B.T.1    Messer, H.H.2
  • 116
    • 0036632661 scopus 로고    scopus 로고
    • The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments
    • Roland D.D., Andelin W.E., Browning D.F., Hsu G.-H.R., and Torabinejad M. The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. J Endod 28 (2002) 543-545
    • (2002) J Endod , vol.28 , pp. 543-545
    • Roland, D.D.1    Andelin, W.E.2    Browning, D.F.3    Hsu, G.-H.R.4    Torabinejad, M.5
  • 117
    • 13544259558 scopus 로고    scopus 로고
    • The influence of manual glide path on the separation rate of NiTi rotary instruments
    • Varela Patinõ P.V., Biedma B.M., Liébana C.R., Cantatore G., and Bahillo J.G. The influence of manual glide path on the separation rate of NiTi rotary instruments. J Endod 31 (2005) 114-116
    • (2005) J Endod , vol.31 , pp. 114-116
    • Varela Patinõ, P.V.1    Biedma, B.M.2    Liébana, C.R.3    Cantatore, G.4    Bahillo, J.G.5
  • 118
    • 3042653630 scopus 로고    scopus 로고
    • In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files
    • Yared G. In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files. J Endod 30 (2004) 410-412
    • (2004) J Endod , vol.30 , pp. 410-412
    • Yared, G.1
  • 120
    • 0036480111 scopus 로고    scopus 로고
    • The deterioration of rotary nickel-titanium files under controlled conditions
    • Svec T.A., and Powers J.M. The deterioration of rotary nickel-titanium files under controlled conditions. J Endod 28 (2002) 105-107
    • (2002) J Endod , vol.28 , pp. 105-107
    • Svec, T.A.1    Powers, J.M.2
  • 121
    • 0033090305 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after simulated clinical use
    • Yared G., Bou Dagher F.E., and Machtou P. Cyclic fatigue of ProFile rotary instruments after simulated clinical use. Int Endod J 32 (1999) 115-119
    • (1999) Int Endod J , vol.32 , pp. 115-119
    • Yared, G.1    Bou Dagher, F.E.2    Machtou, P.3
  • 122
    • 0036528158 scopus 로고    scopus 로고
    • Dynamic torque and apical forces of ProFile. 04 rotary instruments during preparation of curved canals
    • Peters O.A., and Barbakow F. Dynamic torque and apical forces of ProFile. 04 rotary instruments during preparation of curved canals. Int Endod J 35 (2002) 379-389
    • (2002) Int Endod J , vol.35 , pp. 379-389
    • Peters, O.A.1    Barbakow, F.2
  • 123
    • 33644906685 scopus 로고    scopus 로고
    • A comparative study of root canal preparation with NiTi-TEE and K3 rotary NiTi instruments
    • Jodway B., and Hülsmann M. A comparative study of root canal preparation with NiTi-TEE and K3 rotary NiTi instruments. Int Endod J 39 (2006) 71-80
    • (2006) Int Endod J , vol.39 , pp. 71-80
    • Jodway, B.1    Hülsmann, M.2
  • 125
    • 0031296835 scopus 로고    scopus 로고
    • Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    • Silvaggio J., and Hicks M.L. Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files. J Endod 23 (1997) 731-734
    • (1997) J Endod , vol.23 , pp. 731-734
    • Silvaggio, J.1    Hicks, M.L.2
  • 126
    • 0032241088 scopus 로고    scopus 로고
    • Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    • Mize S.B., Clement D.J., Pruett J.P., and Carnes Jr. D.L. Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 24 (1998) 843-847
    • (1998) J Endod , vol.24 , pp. 843-847
    • Mize, S.B.1    Clement, D.J.2    Pruett, J.P.3    Carnes Jr., D.L.4
  • 128
    • 0034139365 scopus 로고    scopus 로고
    • Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations
    • Hilt B.R., Cunningham C.J., Shen C., and Richards N. Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations. J Endod 26 (2000) 76-80
    • (2000) J Endod , vol.26 , pp. 76-80
    • Hilt, B.R.1    Cunningham, C.J.2    Shen, C.3    Richards, N.4
  • 129
    • 0242721011 scopus 로고    scopus 로고
    • The effect of cleaning procedures on fracture properties and corrosion of NiTi files
    • O'Hoy P.Y.Z., Messer H.H., and Palamara J.E.A. The effect of cleaning procedures on fracture properties and corrosion of NiTi files. Int Endod J 36 (2003) 724-732
    • (2003) Int Endod J , vol.36 , pp. 724-732
    • O'Hoy, P.Y.Z.1    Messer, H.H.2    Palamara, J.E.A.3
  • 130
    • 4644257082 scopus 로고    scopus 로고
    • Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions
    • Darabara M., Bourithis L., Zinelis S., and Papadimitriou G.D. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J 37 (2004) 705-710
    • (2004) Int Endod J , vol.37 , pp. 705-710
    • Darabara, M.1    Bourithis, L.2    Zinelis, S.3    Papadimitriou, G.D.4
  • 131
    • 0032214962 scopus 로고    scopus 로고
    • Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment
    • Haïkel Y., Serfaty R., Wilson P., Speisser J.M., and Allemann C. Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24 (1998) 731-735
    • (1998) J Endod , vol.24 , pp. 731-735
    • Haïkel, Y.1    Serfaty, R.2    Wilson, P.3    Speisser, J.M.4    Allemann, C.5
  • 132
    • 0032214289 scopus 로고    scopus 로고
    • Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment
    • Haïkel Y., Serfaty R., Wilson P., Speisser J.M., and Allemann C. Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24 (1998) 736-739
    • (1998) J Endod , vol.24 , pp. 736-739
    • Haïkel, Y.1    Serfaty, R.2    Wilson, P.3    Speisser, J.M.4    Allemann, C.5
  • 134
    • 33749987978 scopus 로고    scopus 로고
    • The LightSpeed root canal instrumentation system
    • Senia E.S., and Wildey W.L. The LightSpeed root canal instrumentation system. Endod Topics 10 (2005) 148-150
    • (2005) Endod Topics , vol.10 , pp. 148-150
    • Senia, E.S.1    Wildey, W.L.2
  • 135
    • 33750023903 scopus 로고    scopus 로고
    • Root canal instrumentation with ProFile instruments
    • Lloyd A. Root canal instrumentation with ProFile instruments. Endod Topics 10 (2005) 151-154
    • (2005) Endod Topics , vol.10 , pp. 151-154
    • Lloyd, A.1
  • 136
    • 33750026914 scopus 로고    scopus 로고
    • HEROShapers: the adapted pitch concept
    • Calas P. HEROShapers: the adapted pitch concept. Endod Topics 10 (2005) 155-162
    • (2005) Endod Topics , vol.10 , pp. 155-162
    • Calas, P.1
  • 137
    • 33749987979 scopus 로고    scopus 로고
    • Reamer with alternating cutting edges - concept and clinical application
    • Baumann M.A. Reamer with alternating cutting edges - concept and clinical application. Endod Topics 10 (2005) 176-178
    • (2005) Endod Topics , vol.10 , pp. 176-178
    • Baumann, M.A.1
  • 138
    • 33750023108 scopus 로고    scopus 로고
    • The K3 rotary nickel titanium instrument system
    • Gambarini G. The K3 rotary nickel titanium instrument system. Endod Topics 10 (2005) 179-182
    • (2005) Endod Topics , vol.10 , pp. 179-182
    • Gambarini, G.1
  • 139
    • 33750002897 scopus 로고    scopus 로고
    • FlexMaster: a universal system
    • Sonntag D. FlexMaster: a universal system. Endod Topics 10 (2005) 183-186
    • (2005) Endod Topics , vol.10 , pp. 183-186
    • Sonntag, D.1
  • 140
    • 33646710822 scopus 로고    scopus 로고
    • The ProTaper technique
    • Ruddle C.J. The ProTaper technique. Endod Topics 10 (2005) 187-190
    • (2005) Endod Topics , vol.10 , pp. 187-190
    • Ruddle, C.J.1
  • 141
    • 0039692111 scopus 로고
    • The prognosis of pulp and root canal therapy
    • Grahnén H., and Hansson L. The prognosis of pulp and root canal therapy. Odontol Revy 12 (1961) 146-165
    • (1961) Odontol Revy , vol.12 , pp. 146-165
    • Grahnén, H.1    Hansson, L.2
  • 142
    • 0041429667 scopus 로고
    • Endodontic success and failure
    • Ingle J.I. (Ed), Lea & Febiger, Philadelphia
    • Ingle J.I., and Glick D.H. Endodontic success and failure. In: Ingle J.I. (Ed). Endodontics. 1st ed. (1965), Lea & Febiger, Philadelphia 54-76
    • (1965) Endodontics. 1st ed. , pp. 54-76
    • Ingle, J.I.1    Glick, D.H.2
  • 144
    • 0034702175 scopus 로고    scopus 로고
    • Randomized controlled trials, observational studies, and the hierarchy of research designs
    • Concato J., Shah H., and Horwitz R. Randomized controlled trials, observational studies, and the hierarchy of research designs. New Engl J Med 342 (2000) 1887-1892
    • (2000) New Engl J Med , vol.342 , pp. 1887-1892
    • Concato, J.1    Shah, H.2    Horwitz, R.3
  • 145
    • 0014610165 scopus 로고
    • Guidelines for the prevention of fracture of root canal instruments
    • Grossman L.I. Guidelines for the prevention of fracture of root canal instruments. Oral Surg Oral Med Oral Pathol 28 (1969) 746-752
    • (1969) Oral Surg Oral Med Oral Pathol , vol.28 , pp. 746-752
    • Grossman, L.I.1
  • 146
    • 0015302568 scopus 로고
    • Filling root canals with files: radiographic evaluation of 304 cases
    • Fox J., Moodnik R.M., Greenfield E., and Atkinson J.S. Filling root canals with files: radiographic evaluation of 304 cases. NY State Dent J 38 (1972) 154-157
    • (1972) NY State Dent J , vol.38 , pp. 154-157
    • Fox, J.1    Moodnik, R.M.2    Greenfield, E.3    Atkinson, J.S.4
  • 147
    • 28144463349 scopus 로고
    • Clinical study on the prognosis of endodontic treatment of teeth with broken instruments
    • (In Greek). Data cited in: Risk Management of Root Canal Treatment Lambrianidis I, ed. Thessaloniki: University Studio Press, 2001: 199-247
    • Molyvdas I., Lambrianidis T., Zervas P., and Veis A. Clinical study on the prognosis of endodontic treatment of teeth with broken instruments. Stoma 20 (1992) 63 (In Greek). Data cited in: Risk Management of Root Canal Treatment Lambrianidis I, ed. Thessaloniki: University Studio Press, 2001: 199-247
    • (1992) Stoma , vol.20 , pp. 63
    • Molyvdas, I.1    Lambrianidis, T.2    Zervas, P.3    Veis, A.4
  • 148
    • 33750002896 scopus 로고    scopus 로고
    • Advances in the study of endodontic infections: introduction
    • Bergenholtz G., and Dahlén G. Advances in the study of endodontic infections: introduction. Endod Topics 9 (2004) 1-4
    • (2004) Endod Topics , vol.9 , pp. 1-4
    • Bergenholtz, G.1    Dahlén, G.2
  • 149
    • 0025581128 scopus 로고
    • Removal of silver cones and fractured instruments using the Canal Finder System
    • Hülsmann M. Removal of silver cones and fractured instruments using the Canal Finder System. J Endod 16 (1990) 596-600
    • (1990) J Endod , vol.16 , pp. 596-600
    • Hülsmann, M.1
  • 150
    • 0027830421 scopus 로고
    • Methods for removing metal obstructions from the root canal
    • Hülsmann M. Methods for removing metal obstructions from the root canal. Endod Dent Traumatol 9 (1993) 223-237
    • (1993) Endod Dent Traumatol , vol.9 , pp. 223-237
    • Hülsmann, M.1
  • 151
    • 10044226329 scopus 로고    scopus 로고
    • Nonsurgical retreatment
    • Ruddle C.J. Nonsurgical retreatment. J Endod 30 (2004) 827-845
    • (2004) J Endod , vol.30 , pp. 827-845
    • Ruddle, C.J.1
  • 152
    • 0015525402 scopus 로고
    • New method for extracting metallic fragments from canals
    • Masserann J. New method for extracting metallic fragments from canals. Inform Dent 54 (1972) 3987-4005
    • (1972) Inform Dent , vol.54 , pp. 3987-4005
    • Masserann, J.1
  • 153
  • 154
    • 0031987164 scopus 로고    scopus 로고
    • Retrieval of a broken endodontic instrument using cyanoacrylate adhesive. A case report
    • Filho T.A., Krebs R.L., Berlinck T.C.A., and Galindo R.G.S. Retrieval of a broken endodontic instrument using cyanoacrylate adhesive. A case report. Braz Dent J 9 (1998) 57-60
    • (1998) Braz Dent J , vol.9 , pp. 57-60
    • Filho, T.A.1    Krebs, R.L.2    Berlinck, T.C.A.3    Galindo, R.G.S.4
  • 155
    • 0020739677 scopus 로고
    • A method for the removal of broken endodontic instruments from root canals
    • Fors U.G., and Berg J.O. A method for the removal of broken endodontic instruments from root canals. J Endod 9 (1983) 156-159
    • (1983) J Endod , vol.9 , pp. 156-159
    • Fors, U.G.1    Berg, J.O.2
  • 156
    • 0019569902 scopus 로고
    • Expanded use of the ultrasonic scaler
    • Gaffney J.L., Lehman J.W., and Miles M.J. Expanded use of the ultrasonic scaler. J Endod 7 (1981) 228-229
    • (1981) J Endod , vol.7 , pp. 228-229
    • Gaffney, J.L.1    Lehman, J.W.2    Miles, M.J.3
  • 157
    • 0022428985 scopus 로고
    • Removal of fractured endodontic instruments using ultrasonics
    • Souyave L.C., Inglis A.T., and Alcalay M. Removal of fractured endodontic instruments using ultrasonics. Br Dent J 159 (1985) 251-253
    • (1985) Br Dent J , vol.159 , pp. 251-253
    • Souyave, L.C.1    Inglis, A.T.2    Alcalay, M.3
  • 158
    • 0022819771 scopus 로고
    • Ultrasonic removal of broken instruments in root canals
    • Nagai O., Tani N., Kayaba Y., Kodama S., and Osada T. Ultrasonic removal of broken instruments in root canals. Int Endod J 19 (1986) 298-304
    • (1986) Int Endod J , vol.19 , pp. 298-304
    • Nagai, O.1    Tani, N.2    Kayaba, Y.3    Kodama, S.4    Osada, T.5
  • 159
    • 0028403113 scopus 로고
    • Removal of fractured instruments using a combined automated/ultrasonic technique
    • Hülsmann M. Removal of fractured instruments using a combined automated/ultrasonic technique. J Endod 20 (1994) 144-147
    • (1994) J Endod , vol.20 , pp. 144-147
    • Hülsmann, M.1
  • 160
    • 0022579685 scopus 로고
    • Endodontic treatment of root canals obstructed by foreign objects
    • Fors U.G., and Berg J.O. Endodontic treatment of root canals obstructed by foreign objects. Int Endod J 19 (1986) 2-10
    • (1986) Int Endod J , vol.19 , pp. 2-10
    • Fors, U.G.1    Berg, J.O.2
  • 161
    • 0031178759 scopus 로고    scopus 로고
    • Micro-endodontic nonsurgical retreatment
    • Ruddle C. Micro-endodontic nonsurgical retreatment. Dent Clin North Am 41 (1997)
    • (1997) Dent Clin North Am , vol.41
    • Ruddle, C.1
  • 162
    • 0036654754 scopus 로고    scopus 로고
    • Broken instrument removal. The endodontic challenge
    • 4, 6 passim
    • Ruddle C.J. Broken instrument removal. The endodontic challenge. Dent Today 21 (2002) 70-72 4, 6 passim
    • (2002) Dent Today , vol.21 , pp. 70-72
    • Ruddle, C.J.1
  • 163
    • 0032087367 scopus 로고    scopus 로고
    • A new method for retrieving silver points and separated instruments from root canals
    • Suter B. A new method for retrieving silver points and separated instruments from root canals. J Endod 24 (1998) 446-448
    • (1998) J Endod , vol.24 , pp. 446-448
    • Suter, B.1
  • 164
    • 0033181969 scopus 로고    scopus 로고
    • A new approach for the retrieval of broken instruments
    • Nehme W. A new approach for the retrieval of broken instruments. J Endod 25 (1999) 633-635
    • (1999) J Endod , vol.25 , pp. 633-635
    • Nehme, W.1
  • 165
    • 13544255593 scopus 로고    scopus 로고
    • Probability of removing fractured instruments from root canals
    • Suter B., Lussi A., and Sequeira P. Probability of removing fractured instruments from root canals. Int Endod J 38 (2005) 112-123
    • (2005) Int Endod J , vol.38 , pp. 112-123
    • Suter, B.1    Lussi, A.2    Sequeira, P.3
  • 166
    • 20444492036 scopus 로고    scopus 로고
    • Complications associated with fractured file removal using an ultrasonic technique
    • Souter N.J., and Messer H.H. Complications associated with fractured file removal using an ultrasonic technique. J Endod 31 (2005) 450-452
    • (2005) J Endod , vol.31 , pp. 450-452
    • Souter, N.J.1    Messer, H.H.2
  • 167
    • 0033287877 scopus 로고    scopus 로고
    • Influence of several factors on the success or failure of removal of fractured instruments from the root canal
    • Hülsmann M., and Schinkel I. Influence of several factors on the success or failure of removal of fractured instruments from the root canal. Endod Dent Traumatol 15 (1999) 252-258
    • (1999) Endod Dent Traumatol , vol.15 , pp. 252-258
    • Hülsmann, M.1    Schinkel, I.2
  • 168
    • 2442707655 scopus 로고    scopus 로고
    • Post placement and restoration of endodontically treated teeth: a literature review
    • Schwartz R.S., and Robbins J.W. Post placement and restoration of endodontically treated teeth: a literature review. J Endod 30 (2004) 289-301
    • (2004) J Endod , vol.30 , pp. 289-301
    • Schwartz, R.S.1    Robbins, J.W.2
  • 169
    • 1942529552 scopus 로고    scopus 로고
    • Evaluation of success and failure
    • Walton R.E., and Torabinejad M. (Eds), W.B. Saunders Co, Philadelphia
    • Sigurdsson A. Evaluation of success and failure. In: Walton R.E., and Torabinejad M. (Eds). Principles and practice of endodontics (2002), W.B. Saunders Co, Philadelphia 331-344
    • (2002) Principles and practice of endodontics , pp. 331-344
    • Sigurdsson, A.1
  • 173
    • 4143058933 scopus 로고    scopus 로고
    • Technical aspects of treatment in relation to treatment outcome
    • Kirkevang L.-L., and Hørsted-Bindslev P. Technical aspects of treatment in relation to treatment outcome. Endod Topics 2 (2002) 89-102
    • (2002) Endod Topics , vol.2 , pp. 89-102
    • Kirkevang, L.-L.1    Hørsted-Bindslev, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.