Volumn 29, Issue 11, 2003, Pages 764-767
|
Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: Clinical cases
|
Author keywords
[No Author keywords available]
|
Indexed keywords
NICKEL;
TITANIUM;
DENTAL ALLOY;
TITANIUM NICKELIDE;
ADULT;
ARTICLE;
CASE REPORT;
CLINICAL PRACTICE;
DENTAL EQUIPMENT;
ENDODONTICS;
EVALUATION;
FEMALE;
HUMAN;
HUMAN TISSUE;
MALE;
MICROSCOPE;
PERFORATION;
SURGICAL TECHNIQUE;
TOOTH ROOT CANAL;
ULTRASOUND;
EQUIPMENT;
EQUIPMENT DESIGN;
FOREIGN BODY;
INSTRUMENTATION;
MICROSCOPY;
MIDDLE AGED;
PATHOLOGY;
TIME;
TOOTH PULP;
TREATMENT OUTCOME;
ADULT;
DENTAL ALLOYS;
DENTAL PULP CAVITY;
EQUIPMENT DESIGN;
EQUIPMENT FAILURE;
FEMALE;
FOREIGN BODIES;
HUMANS;
MALE;
MICROSCOPY;
MIDDLE AGED;
NICKEL;
ROOT CANAL OBTURATION;
ROOT CANAL PREPARATION;
TIME FACTORS;
TITANIUM;
TREATMENT OUTCOME;
ULTRASONICS;
|
EID: 1542786390
PISSN: 00992399
EISSN: None
Source Type: Journal
DOI: 10.1097/00004770-200311000-00018 Document Type: Article |
Times cited : (70)
|
References (11)
|