메뉴 건너뛰기




Volumn 26, Issue 2, 2000, Pages 76-80

Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; EPOXY RESIN; NICKEL; STAINLESS STEEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0034139365     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004770-200002000-00004     Document Type: Article
Times cited : (39)

References (19)
  • 1
    • 0020713589 scopus 로고
    • The effect of autoclave sterilization on endodontic files
    • Mitchell BF, James MS, Nelson RC. The effect of autoclave sterilization on endodontic files. Oral Surg 1983;55:204-7.
    • (1983) Oral Surg , vol.55 , pp. 204-207
    • Mitchell, B.F.1    James, M.S.2    Nelson, R.C.3
  • 2
    • 1942483565 scopus 로고
    • Revised American National Standards Institute/American Dental Association Specification No. 28 for root canal files and reamers, type K revised
    • Council on Dental Materials. Instrument and Equipment, Revised American National Standards Institute/American Dental Association Specification No. 28 for root canal files and reamers, type K (revised 1988).
    • (1988) Instrument and Equipment
  • 3
    • 0022074302 scopus 로고
    • The effects of various sterilization methods on the torsional strength of endodontic files
    • Iverson GW, Von Fraunhofer VA, Herman JW. The effects of various sterilization methods on the torsional strength of endodontic files. J Endodon 1983;11:266-8.
    • (1983) J Endodon , vol.11 , pp. 266-268
    • Iverson, G.W.1    Von Fraunhofer, V.A.2    Herman, J.W.3
  • 5
    • 0030622442 scopus 로고    scopus 로고
    • Effects of cleaning, chemical disinfection, and sterilization procedures on the mechanical properties of endodontic instruments
    • Haikel Y, Serfaty R, Bleicher P, Lwin TT, Allemann C. Effects of cleaning, chemical disinfection, and sterilization procedures on the mechanical properties of endodontic instruments. J Endodon 1997;23:5-8.
    • (1997) J Endodon , vol.23 , pp. 5-8
    • Haikel, Y.1    Serfaty, R.2    Bleicher, P.3    Lwin, T.T.4    Allemann, C.5
  • 6
    • 0016662355 scopus 로고
    • Potential applications of certain nickel-titanium alloys
    • Civian S, Huget EF, DeSimon LB. Potential applications of certain nickel-titanium alloys. J Dent Res 1975;54:89-96.
    • (1975) J Dent Res , vol.54 , pp. 89-96
    • Civian, S.1    Huget, E.F.2    DeSimon, L.B.3
  • 7
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia H, Brantely WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endodon 1988;14:346-51.
    • (1988) J Endodon , vol.14 , pp. 346-351
    • Walia, H.1    Brantely, W.A.2    Gerstein, H.3
  • 9
    • 0031296835 scopus 로고    scopus 로고
    • Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    • Silvaggio J, Hicks ML. Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files. J Endodon 1997;23:731-4.
    • (1997) J Endodon , vol.23 , pp. 731-734
    • Silvaggio, J.1    Hicks, M.L.2
  • 10
    • 0025405676 scopus 로고
    • A systematic approach to preventing intracanal breakage of endodontic files
    • Sotokawa T. A systematic approach to preventing intracanal breakage of endodontic files. Endod Dent Traumatol 1990;6:60-2.
    • (1990) Endod Dent Traumatol , vol.6 , pp. 60-62
    • Sotokawa, T.1
  • 12
    • 0026166609 scopus 로고
    • Dynamic fracture of hybrid endodontic hand instruments compared with traditional files
    • Haikel Y, Gasser D, Allemann C. Dynamic fracture of hybrid endodontic hand instruments compared with traditional files. J Endodon 1991;17:217-20.
    • (1991) J Endodon , vol.17 , pp. 217-220
    • Haikel, Y.1    Gasser, D.2    Allemann, C.3
  • 13
    • 0028724897 scopus 로고
    • Relationship between file size and stiffness of stainless steel instruments
    • Camps JJ, Pertot WJ. Relationship between file size and stiffness of stainless steel instruments. Endod Dent Traumatol 1994;10:260-3.
    • (1994) Endod Dent Traumatol , vol.10 , pp. 260-263
    • Camps, J.J.1    Pertot, W.J.2
  • 14
    • 0025475372 scopus 로고
    • Torsional properties of twisted and machined endodontic files
    • Seto BG, Nicholls JI, Harrington GW. Torsional properties of twisted and machined endodontic files. J Endodon 1990;16:355-60.
    • (1990) J Endodon , vol.16 , pp. 355-360
    • Seto, B.G.1    Nicholls, J.I.2    Harrington, G.W.3
  • 15
    • 0020147860 scopus 로고
    • Bending and torsion of endodontic files with rhombus cross sections
    • Dolan D, Craig R. Bending and torsion of endodontic files with rhombus cross sections. J Endodon 1982;8:160-4.
    • (1982) J Endodon , vol.8 , pp. 160-164
    • Dolan, D.1    Craig, R.2
  • 16
    • 0018477052 scopus 로고
    • A study of torsional and angular deflection of endodontic files and reamers
    • Lentine FN. A study of torsional and angular deflection of endodontic files and reamers. J Endodon 1979;5:181-91.
    • (1979) J Endodon , vol.5 , pp. 181-191
    • Lentine, F.N.1
  • 18
    • 0023958647 scopus 로고
    • An analysis of clinical breakage of root canal instruments
    • Sotokawa T. An analysis of clinical breakage of root canal instruments. J Endodon 1988;14:75-82.
    • (1988) J Endodon , vol.14 , pp. 75-82
    • Sotokawa, T.1
  • 19
    • 0030325526 scopus 로고    scopus 로고
    • Effects of cleaning, disinfection, and sterilization procedures on the cutting efficiency of endodontic files
    • Haikel Y, Serfaty R, Bleicher P, Lwin TT, Allemann C. Effects of cleaning, disinfection, and sterilization procedures on the cutting efficiency of endodontic files. J Endodon 1996;22:657-61.
    • (1996) J Endodon , vol.22 , pp. 657-661
    • Haikel, Y.1    Serfaty, R.2    Bleicher, P.3    Lwin, T.T.4    Allemann, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.