메뉴 건너뛰기




Volumn 11, Issue 2, 2006, Pages

Bioenzymatic detection of troponin C using micro-optoelectro-mechanical systems

Author keywords

Bioenzyme; Cantilever beams; Microelectro mechanical systems; Myocardial infarction; Troponin C

Indexed keywords

TROPONIN C;

EID: 33746411165     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.2186326     Document Type: Article
Times cited : (13)

References (21)
  • 1
    • 12244301558 scopus 로고    scopus 로고
    • Determination of affinities and antigenic epitopes of bovine cardiac troponin I (cTnI) with monoclonal antibodies by surface plasmon resonance biosensor
    • DOI 10.1016/S0003-2697(02)00696-6
    • X. Liu and J. Wei, "Determination of affinities and antigen epitopes of bovine cardiac troponin I (cTnl) with monoclonal antibodies by surface plasmon resonance biosensor", Anal. Biochem. 314, 301-309 (2003). (Pubitemid 36315912)
    • (2003) Analytical Biochemistry , vol.314 , Issue.2 , pp. 301-309
    • Liu, X.1    Wei, J.2    Song, D.3    Zhang, Z.4    Zhang, H.5    Luo, G.6
  • 2
    • 0031907424 scopus 로고    scopus 로고
    • Early detection of cardiac damage with heart fatty acid-binding protein after cardiac operations
    • K. Suzuki and Y. Sawa, "Early detection of cardiac damage with heart fatty acid-binding protein after cardiac operations", Ann. Thorac. Surg. 65, 54-58 (1997).
    • (1997) Ann. Thorac. Surg. , vol.65 , pp. 54-58
    • Suzuki, K.1    Sawa, Y.2
  • 3
    • 0021012476 scopus 로고
    • Diagnostic criteria and prognosis of perioperative myocardial infarction following coronary bypass
    • V. P. Guiteras, L. C. Pelletier, M. G. Hernandez, J. M. Jais, B. R. Caitman, G. Dupres, and B. CG. Solymass, "Diagnostic criteria and prognosis of preoperative myocardial infarction following coronary bypass", J. Thorac. Cardiovasc. Surg. 86, 878-886 (1983). (Pubitemid 14209271)
    • (1983) Journal of Thoracic and Cardiovascular Surgery , vol.86 , Issue.6 , pp. 878-886
    • Val, P.G.1    Pelletier, L.C.2    Hernandez, M.G.3
  • 4
    • 0033037025 scopus 로고    scopus 로고
    • The lack of standardization of cardiac troponin I assay systems
    • DOI 10.1016/S0009-8981(99)00076-5, PII S0009898199000765
    • J. R. Tate, D. Heathcote, J. Rayfield, and P. E. Hickman, "The lack of standardization of cardiac troponin I assay systems", Clin. Chim. Acta 284, 141-149 (1999). (Pubitemid 29299398)
    • (1999) Clinica Chimica Acta , vol.284 , Issue.2 , pp. 141-149
    • Tate, J.R.1    Heathcote, D.2    Rayfield, J.3    Hickman, P.E.4
  • 6
    • 0001135883 scopus 로고    scopus 로고
    • Electrocatalysis and Measurements of Hydrazine Compounds at Glassy Carbon Electrodes Coated with Electropolymerized 3,4-Dihydroxybenzaldehyde Films
    • P. V. A. Pamidi and J. Wang, "Electroanalysis and measurement of hydrazine compounds at glassy carbon electrodes coated with electropolymerized 3, 4'-dihydroxybenaldehyde films", Electroanalysis 8, 244-247 (1996). (Pubitemid 126419517)
    • (1996) Electroanalysis , vol.8 , Issue.3 , pp. 244-247
    • Pamidi, P.V.A.1    Wang, J.2
  • 9
    • 0030014940 scopus 로고    scopus 로고
    • A sensitive method to measure changes in the surface stress of solids
    • R. Raiteri, H. J. Butt, and M. Grattarola, "A sensitive method to measure changes in the surface stress of solids", J. Colloid Interface Sci. 180, 251-260 (1996).
    • (1996) J. Colloid Interface Sci. , vol.180 , pp. 251-260
    • Raiteri, R.1    Butt, H.J.2    Grattarola, M.3
  • 11
    • 0034874270 scopus 로고    scopus 로고
    • Bioassay of prostate-specific antigen (PSA) using microcantilevers
    • DOI 10.1038/nbt0901-856
    • W. Guanghua, R. H. Datar, K. M. Hansen, T. Thundat, R. J. Cote, and A. Majumdar, "Bioassay of prostate-specific antigen (PSA) using micro-cantilever", Nat. Biotechnol. 19, 856-860 (2001). (Pubitemid 32816756)
    • (2001) Nature Biotechnology , vol.19 , Issue.9 , pp. 856-860
    • Wu, G.1    Datar, R.H.2    Hansen, K.M.3    Thundat, T.4    Cote, R.J.5    Majumdar, A.6
  • 13
    • 0041413204 scopus 로고    scopus 로고
    • Fourier transform infrared studies of peptides: Potentials and pitfalls
    • P. I. Harris, "Fourier transform infrared studies of peptides: Potentials and pitfalls", ACS Symp. Ser. 750, 54-95 (2000).
    • (2000) ACS Symp. Ser. , vol.750 , pp. 54-95
    • Harris, P.I.1
  • 14
    • 0022146915 scopus 로고
    • Natural frequencies of rectangular plates using characterization orthogonal polynomials in Rayleigh-Ritz method
    • R. B. Bhat, "Natural frequencies of rectangular plates using characterization orthogonal polynomials in Rayleigh-Ritz method", J. Sound Vib. 102, 493-497 (1985).
    • (1985) J. Sound Vib. , vol.102 , pp. 493-497
    • Bhat, R.B.1
  • 15
    • 8844244894 scopus 로고    scopus 로고
    • Experimental investigation on the dynamics of MEMS structures
    • G. Rinaldi, M. Packirisamy, and I. G. Stiharu, "Experimental investigation on the dynamics of MEMS structures", Proc. SPIE 5455, 66-73 (2004).
    • (2004) Proc. SPIE , vol.5455 , pp. 66-73
    • Rinaldi, G.1    Packirisamy, M.2    Stiharu, I.G.3
  • 18
    • 8844281665 scopus 로고    scopus 로고
    • Micro electro mechanical systems (MEMS) for enzymatic detection
    • J. Amritsar, I. Stiharu, and M. Packirisamy, "Micro electro mechanical systems (MEMS) for enzymatic detection", Proc. SPIE 5455, 101-109 (2004).
    • (2004) Proc. SPIE , vol.5455 , pp. 101-109
    • Amritsar, J.1    Stiharu, I.2    Packirisamy, M.3
  • 19
    • 0033554758 scopus 로고    scopus 로고
    • Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers
    • DOI 10.1016/S0925-4005(99)00251-8
    • P. G. Datskos and I. Sauers, "Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers", Sens. Actuators B B61, 75-82 (1999). (Pubitemid 30526202)
    • (1999) Sensors and Actuators, B: Chemical , vol.61 , Issue.1 , pp. 75-82
    • Datskos, P.G.1    Sauers, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.