메뉴 건너뛰기




Volumn 27, Issue 6, 2005, Pages 770-778

Development and validation of a high-throughput assay for quantification of the proliferation inhibitor ABT-578 using LC/LC-MS/MS in blood and tissue samples

Author keywords

Automated sample preparation; Column switching; Drug eluting stents; LC MS; Sirolimus derivatives; Tissue concentrations

Indexed keywords

ABT 578; DRUG DERIVATIVE; GROWTH INHIBITOR; RAPAMYCIN;

EID: 33646829641     PISSN: 01634356     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ftd.0000185766.52126.bd     Document Type: Conference Paper
Times cited : (21)

References (28)
  • 1
    • 0036912410 scopus 로고    scopus 로고
    • Review of the proliferation inhibitor everolimus
    • Nashan B. Review of the proliferation inhibitor everolimus. Expert Opin Investig Drugs. 2002;11:1845-1857.
    • (2002) Expert Opin Investig Drugs , vol.11 , pp. 1845-1857
    • Nashan, B.1
  • 2
    • 0035166897 scopus 로고    scopus 로고
    • Sirolimus: A comprehensive review
    • Kahan BD. Sirolimus: a comprehensive review. Expert Opin Pharmacother. 2001;2:1903-1917.
    • (2001) Expert Opin Pharmacother , vol.2 , pp. 1903-1917
    • Kahan, B.D.1
  • 3
    • 0027301130 scopus 로고
    • Rapamycin inhibits arterial intima thickening caused by both alloimmune and mechanical injury. Its effect on cellular, growth factors and cytokine response in injured vessels
    • Gregory CR, Huie P, Billingham ME, et al. Rapamycin inhibits arterial intima thickening caused by both alloimmune and mechanical injury. Its effect on cellular, growth factors and cytokine response in injured vessels. Transplantation. 1993;55:1409-1418.
    • (1993) Transplantation , vol.55 , pp. 1409-1418
    • Gregory, C.R.1    Huie, P.2    Billingham, M.E.3
  • 5
    • 0037452233 scopus 로고    scopus 로고
    • Drug-eluting stents in vascular intervention
    • Fattori R, Piva T. Drug-eluting stents in vascular intervention. Lancet. 2003;361:247-249.
    • (2003) Lancet , vol.361 , pp. 247-249
    • Fattori, R.1    Piva, T.2
  • 7
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, for the RAVEL study group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 8
    • 9144226193 scopus 로고    scopus 로고
    • Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients. Insights from the RAVEL trial
    • Abizaid A, Costa M, Blannchard D, et al. Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients. Insights from the RAVEL trial. Eur Heart J. 2004;25:107-112.
    • (2004) Eur Heart J , vol.25 , pp. 107-112
    • Abizaid, A.1    Costa, M.2    Blannchard, D.3
  • 9
    • 15244351130 scopus 로고    scopus 로고
    • 13C assignments for rapamycin
    • 13C assignments for rapamycin. Magn Reson Chem. 2005;43:174-175.
    • (2005) Magn Reson Chem , vol.43 , pp. 174-175
    • Pagano, T.G.1
  • 10
    • 1942424154 scopus 로고    scopus 로고
    • ABT-578-eluting stents. The promising successor of sirolimus- and paclitaxel-eluting stent concepts?
    • Buellesfeld L, Grube E. ABT-578-eluting stents. The promising successor of sirolimus- and paclitaxel-eluting stent concepts? Herz. 2004;29:167-170.
    • (2004) Herz , vol.29 , pp. 167-170
    • Buellesfeld, L.1    Grube, E.2
  • 11
    • 3042526124 scopus 로고    scopus 로고
    • Optimal stent design for drug delivery
    • Rogers CD. Optimal stent design for drug delivery. Rev Cardiovasc Med. 2004;4(Suppl. 2):S9-S15.
    • (2004) Rev Cardiovasc Med , vol.4 , Issue.2 SUPPL.
    • Rogers, C.D.1
  • 12
    • 2042441795 scopus 로고    scopus 로고
    • 96-Well liquid-liquid extraction liquid chromatography-tandem mass spectrometry method for the quantitative determination of ABT-578 in human blood samples
    • Ji QC, Reimer TM, El-Shourbagy TA. 96-Well liquid-liquid extraction liquid chromatography-tandem mass spectrometry method for the quantitative determination of ABT-578 in human blood samples. J Chromatogr B Analyt Technol Biomed Life Sci. 2004;805:67-75.
    • (2004) J Chromatogr B Analyt Technol Biomed Life Sci , vol.805 , pp. 67-75
    • Ji, Q.C.1    Reimer, T.M.2    El-Shourbagy, T.A.3
  • 13
    • 4644335582 scopus 로고    scopus 로고
    • Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometry detection
    • Ji QC, Zhang J, Rodila R, et al. Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometry detection. Rapid Commun Mass Spectrom. 2004;18:2293-2298.
    • (2004) Rapid Commun Mass Spectrom , vol.18 , pp. 2293-2298
    • Ji, Q.C.1    Zhang, J.2    Rodila, R.3
  • 14
    • 0030476603 scopus 로고    scopus 로고
    • Structural identification of four metabolites of the macrolide immunosuppressant sirolimus after in vitro metabolism by electrospray-MS/MS
    • Streit F, Christians U, Schiebel HM, et al. Structural identification of four metabolites of the macrolide immunosuppressant sirolimus after in vitro metabolism by electrospray-MS/MS. Drug Metab Dispos. 1996;24:1272-1278.
    • (1996) Drug Metab Dispos , vol.24 , pp. 1272-1278
    • Streit, F.1    Christians, U.2    Schiebel, H.M.3
  • 15
    • 0034477611 scopus 로고    scopus 로고
    • Identification of a new metabolite of macrolide immunosuppressants, like rapamycin and SDZ-RAD, using high-performance liquid chromatography and electrospray tandem mass spectrometry
    • Hallensleben K, Raida M, Habermehl G. Identification of a new metabolite of macrolide immunosuppressants, like rapamycin and SDZ-RAD, using high-performance liquid chromatography and electrospray tandem mass spectrometry. J Am Soc Mass Spectrom. 2000;11:516-525.
    • (2000) J Am Soc Mass Spectrom , vol.11 , pp. 516-525
    • Hallensleben, K.1    Raida, M.2    Habermehl, G.3
  • 16
    • 0037097063 scopus 로고    scopus 로고
    • Ion suppression effects in liquid chromatrography-electrospray-ionization transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries
    • Müller C, Schäfer P, Störtzel M, et al. Ion suppression effects in liquid chromatrography-electrospray-ionization transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries. J Chromatogr B. 2002;773:47-52.
    • (2002) J Chromatogr B , vol.773 , pp. 47-52
    • Müller, C.1    Schäfer, P.2    Störtzel, M.3
  • 17
    • 25444464785 scopus 로고    scopus 로고
    • Mass interferences in quantification of cyclosporine using tandem mass spectrometry without chromatography
    • Streit F, Armstrong VW, Oellerich M. Mass interferences in quantification of cyclosporine using tandem mass spectrometry without chromatography. Ther Drug Monit. 2003;25:506.
    • (2003) Ther Drug Monit , vol.25 , pp. 506
    • Streit, F.1    Armstrong, V.W.2    Oellerich, M.3
  • 18
    • 0042554198 scopus 로고
    • Determination of drugs and their metabolites in biological samples by fully automated HPLC with on-line extraction and pre-column switching
    • Frei RW, Zech K, eds. Selective Sample Handling and Detection in High-Performance Liquid Chromatography. Amsterdam: Elsevier
    • Huber R, Zech K. Determination of drugs and their metabolites in biological samples by fully automated HPLC with on-line extraction and pre-column switching. In: Frei RW, Zech K, eds. Selective Sample Handling and Detection in High-Performance Liquid Chromatography. Journal of Chromatography Library, vol 39A. Amsterdam: Elsevier; 1988, pp 81-144.
    • (1988) Journal of Chromatography Library , vol.39 A , pp. 81-144
    • Huber, R.1    Zech, K.2
  • 19
    • 0034306732 scopus 로고    scopus 로고
    • Automated, fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: Immunosuppressants
    • Christians U, Jacobsen W, Serkova N, et al. Automated, fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: immunosuppressants. J Chromatogr B. 2000;748:41-53.
    • (2000) J Chromatogr B , vol.748 , pp. 41-53
    • Christians, U.1    Jacobsen, W.2    Serkova, N.3
  • 20
    • 0036267333 scopus 로고    scopus 로고
    • Rapid liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of sirolimus, everolimus, tacrolimus, and cyclosporine in whole blood
    • Streit F, Armstrong VW, Oellerich M. Rapid liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of sirolimus, everolimus, tacrolimus, and cyclosporine in whole blood. Clin Chem. 2002;48:955-958.
    • (2002) Clin Chem , vol.48 , pp. 955-958
    • Streit, F.1    Armstrong, V.W.2    Oellerich, M.3
  • 21
    • 0031777929 scopus 로고    scopus 로고
    • Automated simultaneous quantification of the immunosuppressant 40-O-(2-hydroxyethyl) rapamycin and cyclosporine in blood with electrospray-mass spectrometric detection
    • Vidal C, Kirchner GI, Wuensch G, et al. Automated simultaneous quantification of the immunosuppressant 40-O-(2-hydroxyethyl) rapamycin and cyclosporine in blood with electrospray-mass spectrometric detection. Clin Chem. 1998;44:1275-1282.
    • (1998) Clin Chem , vol.44 , pp. 1275-1282
    • Vidal, C.1    Kirchner, G.I.2    Wuensch, G.3
  • 22
    • 0033039186 scopus 로고    scopus 로고
    • Simultaneous on-line extraction and analysis of sirolimus (rapamycin) and ciclosporin in blood by liquid chromatography-electrospray mass spectrometry
    • Kirchner GI, Vidal C, Jacobsen W, et al. Simultaneous on-line extraction and analysis of sirolimus (rapamycin) and ciclosporin in blood by liquid chromatography-electrospray mass spectrometry. J Chromatogr B. 1999;721:285-294.
    • (1999) J Chromatogr B , vol.721 , pp. 285-294
    • Kirchner, G.I.1    Vidal, C.2    Jacobsen, W.3
  • 23
    • 0033060549 scopus 로고    scopus 로고
    • LC/ESI-MS allows simultaneous and specific quantification of SDZ-RAD and cyclosporine, including groups of their metabolites in human blood
    • Kirchner GI, Vidal C, Winkler M, et al. LC/ESI-MS allows simultaneous and specific quantification of SDZ-RAD and cyclosporine, including groups of their metabolites in human blood. Ther Drug Monit. 1999;21:116-122.
    • (1999) Ther Drug Monit , vol.21 , pp. 116-122
    • Kirchner, G.I.1    Vidal, C.2    Winkler, M.3
  • 24
    • 0036238215 scopus 로고    scopus 로고
    • Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS)
    • Deters M, Resch K, Kaever V. Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS). Clin Chem Lab Med. 2002;40:285-292.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 285-292
    • Deters, M.1    Resch, K.2    Kaever, V.3
  • 25
    • 0037181426 scopus 로고    scopus 로고
    • Exposure-response relationships for everolimus in de novo kidney transplantation: Defining a therapeutic range
    • Kovarik JM, Kaplan B, Tedesco Silva H, et al. Exposure-response relationships for everolimus in de novo kidney transplantation: defining a therapeutic range. Transplantation. 2002;73:920-925.
    • (2002) Transplantation , vol.73 , pp. 920-925
    • Kovarik, J.M.1    Kaplan, B.2    Tedesco Silva, H.3
  • 26
    • 33748712150 scopus 로고    scopus 로고
    • Consensus guidelines for therapeutic drug monitoring of rapamycin: Report of the consensus panel
    • Yatscoff RW, Boeckx R, Holt DW, et al. Consensus guidelines for therapeutic drug monitoring of rapamycin: report of the consensus panel. Ther Drug Monit. 1996;29:43-49.
    • (1996) Ther Drug Monit , vol.29 , pp. 43-49
    • Yatscoff, R.W.1    Boeckx, R.2    Holt, D.W.3
  • 27
    • 0033932343 scopus 로고    scopus 로고
    • Tissue distribution and clinical monitoring of the novel macrolide immunosuppressant SDZ-RAD and its metabolites in monkey lung transplant recipients: Interaction with cyclosporine
    • Serkova N, Hausen B, Berry GJ, et al. Tissue distribution and clinical monitoring of the novel macrolide immunosuppressant SDZ-RAD and its metabolites in monkey lung transplant recipients: interaction with cyclosporine. J Pharmacol Exp Ther. 2000;294:323-332.
    • (2000) J Pharmacol Exp Ther , vol.294 , pp. 323-332
    • Serkova, N.1    Hausen, B.2    Berry, G.J.3
  • 28
    • 0028500440 scopus 로고
    • High-performance liquid chromatographic isolation, spectroscopic characterization, and immunosuppressive activities of two rapamycin degradation products
    • Wang PC. Chan KW, Schiksnis RA, Scatina J, Sisenwine SF. High-performance liquid chromatographic isolation, spectroscopic characterization, and immunosuppressive activities of two rapamycin degradation products. J Liq Chromatogr. 1994;17:3383-3392.
    • (1994) J Liq Chromatogr , vol.17 , pp. 3383-3392
    • Wang, P.C.1    Chan, K.W.2    Schiksnis, R.A.3    Scatina, J.4    Sisenwine, S.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.