메뉴 건너뛰기




Volumn 25, Issue 2, 2004, Pages 107-112

Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients: Insights from the RAVEL Trial

(14)  Abizaid, Alexandre a,k   Costa, Marco A b   Bianchard, Didier c   Albertal, Mariano a   Eltchaninoff, Hélèn d   Guagliumi, Giulio e   Geert Jan, Laarman f   Abizaid, Andrea S a   Sousa, Amanda G M R a   Wuelfert, Egon g   Wietze, Lindeboom h   Sousa, J Eduardo a   Serruys, Patrick W i   Morice, Marie Claude j  


Author keywords

Diabetes; Drug eluting stents; Restenosis; Sirolimus

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; FIBRINOGEN RECEPTOR ANTAGONIST; RAPAMYCIN; TICLOPIDINE;

EID: 9144226193     PISSN: 0195668X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ehj.2003.11.002     Document Type: Article
Times cited : (111)

References (16)
  • 1
    • 0027479588 scopus 로고
    • Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus
    • Carrozza JP Jr, Kuntz RE, Fishman RF et al. Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus. Ann Intern Med 1993;118:344-9.
    • (1993) Ann Intern Med , vol.118 , pp. 344-349
    • Carrozza Jr., J.P.1    Kuntz, R.E.2    Fishman, R.F.3
  • 2
    • 0028918473 scopus 로고
    • Influence of diabetes mellitus on early and late outcome after percutaneous transluminal coronary angioplasty
    • Stein B, Weintraub WS, Gebhart SP et al. Influence of diabetes mellitus on early and late outcome after percutaneous transluminal coronary angioplasty. Circulation 1995;91:979-89.
    • (1995) Circulation , vol.91 , pp. 979-989
    • Stein, B.1    Weintraub, W.S.2    Gebhart, S.P.3
  • 3
    • 0033537467 scopus 로고    scopus 로고
    • Coronary revascularization in diabetic patients: A comparison of the randomized and observational components of the Bypass Angioplasty Revascularization Investigation (BARI)
    • Detre KM, Guo P, Holubkov R et al. Coronary revascularization in diabetic patients: a comparison of the randomized and observational components of the Bypass Angioplasty Revascularization Investigation (BARI). Circulation 1999;99:633-40.
    • (1999) Circulation , vol.99 , pp. 633-640
    • Detre, K.M.1    Guo, P.2    Holubkov, R.3
  • 4
    • 0032406132 scopus 로고    scopus 로고
    • Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
    • Elezi S, Kastrati A, Pache J et al. Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement. J Am Coll Cardiol 1998;32:1866-73.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1866-1873
    • Elezi, S.1    Kastrati, A.2    Pache, J.3
  • 5
    • 0031670506 scopus 로고    scopus 로고
    • The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation
    • Abizaid A, Kornowski R, Mintz GS et al. The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation. J Am Coll Cardiol 1998;32:584-9.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 584-589
    • Abizaid, A.1    Kornowski, R.2    Mintz, G.S.3
  • 6
    • 0037036837 scopus 로고    scopus 로고
    • Effects of coronary stenting on vessel patency and long-term clinical outcome after percutaneous coronary revascularization in diabetic patients
    • Van Bette E, Perie M, Braune D et al. Effects of coronary stenting on vessel patency and long-term clinical outcome after percutaneous coronary revascularization in diabetic patients. J Am Coll Cardiol 2002;40:410-7.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 410-417
    • Van Bette, E.1    Perie, M.2    Braune, D.3
  • 7
    • 14344271133 scopus 로고    scopus 로고
    • Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    • Sousa JE, Costa MA, Abizaid A et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation 2001;103:192-5.
    • (2001) Circulation , vol.103 , pp. 192-195
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.3
  • 8
    • 0035940374 scopus 로고    scopus 로고
    • Sustained suppression of neointimat proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up
    • Sousa JE, Costa MA, Abizaid AC et al. Sustained suppression of neointimat proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation 2001;104:2007-11.
    • (2001) Circulation , vol.104 , pp. 2007-2011
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.C.3
  • 9
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-80.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 10
    • 1642478750 scopus 로고
    • Estimation of a common effect parameter from sparse follow-up data
    • Greenland S, Robins JM. Estimation of a common effect parameter from sparse follow-up data. Biometrics 1985;312:932-6.
    • (1985) Biometrics , vol.312 , pp. 932-936
    • Greenland, S.1    Robins, J.M.2
  • 11
    • 0030895089 scopus 로고    scopus 로고
    • Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study
    • Kornowski R, Mintz GS, Kent KM et al. Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study. Circulation 1997;95:1366-9.
    • (1997) Circulation , vol.95 , pp. 1366-1369
    • Kornowski, R.1    Mintz, G.S.2    Kent, K.M.3
  • 12
    • 0037062662 scopus 로고    scopus 로고
    • Impact of different platelet glycoprotein iib/iiia receptor inhibitors among diabetic patients undergoing percutaneous coronary intervention. Do Tirofiban and ReoPro Give Similar Efficacy Outcomes Trial (TARGET) 1-Year Follow-Up
    • Roffi M, Moliterno DJ, Meier B et al. Impact of different platelet glycoprotein iib/iiia receptor inhibitors among diabetic patients undergoing percutaneous coronary intervention. Do Tirofiban and ReoPro Give Similar Efficacy Outcomes Trial (TARGET) 1-Year Follow-Up. Circulation 2002;105:2730-6.
    • (2002) Circulation , vol.105 , pp. 2730-2736
    • Roffi, M.1    Moliterno, D.J.2    Meier, B.3
  • 13
    • 0034127394 scopus 로고    scopus 로고
    • Eight-year mortality in the Emory Angioplasty versus Surgery Trial (EAST)
    • King SB 3rd, Kosinski AS, Guyton RA et al. Eight-year mortality in the Emory Angioplasty versus Surgery Trial (EAST). J Am Coll Cardiol 2000;35:1116-21.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1116-1121
    • King III, S.B.1    Kosinski, A.S.2    Guyton, R.A.3
  • 14
    • 0035806921 scopus 로고    scopus 로고
    • Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model
    • Suzuki T, Kopia G, Hayashi S et al. Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model. Circulation 2001;104:1188-93.
    • (2001) Circulation , vol.104 , pp. 1188-1193
    • Suzuki, T.1    Kopia, G.2    Hayashi, S.3
  • 15
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses J W, Leon MB, Popma JJ et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 16
    • 0033613541 scopus 로고    scopus 로고
    • Optimizing the percutaneous interventional outcomes for patients with diabetes mellitus: Results of the EPISTENT (Evaluation of platelet IIb/IIa inhibitor for stenting trial) diabetic substudy
    • Marso SP, Lincoff AM, Ellis SG et al. Optimizing the percutaneous interventional outcomes for patients with diabetes mellitus: results of the EPISTENT (Evaluation of platelet IIb/IIa inhibitor for stenting trial) diabetic substudy. Circulation 1999;100:2477-84.
    • (1999) Circulation , vol.100 , pp. 2477-2484
    • Marso, S.P.1    Lincoff, A.M.2    Ellis, S.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.