메뉴 건너뛰기




Volumn 27, Issue 5, 2005, Pages 240-248

Mineral content changes in bone associated with damage induced by the electron beam

Author keywords

Backscattered electron imaging; Bone; Bone mineralization; Energy dispersive x ray spectroscopy; Osteon

Indexed keywords

ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ELECTRON BEAMS; ENERGY DISPERSIVE SPECTROSCOPY; IMAGING TECHNIQUES; POLYMETHYL METHACRYLATES; TISSUE;

EID: 27344447285     PISSN: 01610457     EISSN: None     Source Type: Journal    
DOI: 10.1002/sca.4950270504     Document Type: Article
Times cited : (20)

References (32)
  • 2
    • 0025458865 scopus 로고
    • Backscattered electron imaging: The role in calcified tissue and implant analysis
    • Bloebaum RD, Bachus KN, Boyce TM: Backscattered electron imaging: The role in calcified tissue and implant analysis. J Biomater Appl 5, 56-85 (1990)
    • (1990) J Biomater Appl , vol.5 , pp. 56-85
    • Bloebaum, R.D.1    Bachus, K.N.2    Boyce, T.M.3
  • 3
    • 0030969087 scopus 로고    scopus 로고
    • Determining mineral content variations in bone using backscattered electron imaging
    • Bloebaum RD, Skedros JG, Vajda EG, Bachus KN, Constantz BR: Determining mineral content variations in bone using backscattered electron imaging. Bone 20, 485-490 (1997)
    • (1997) Bone , vol.20 , pp. 485-490
    • Bloebaum, R.D.1    Skedros, J.G.2    Vajda, E.G.3    Bachus, K.N.4    Constantz, B.R.5
  • 4
    • 0025490365 scopus 로고
    • Reproducible methods for calibrating the backscattered electron signal for quantitative assessment of mineral content in bone
    • discussion 600-603
    • Boyce TM, Bloebaum RD, Bachus KN and Skedros JG: Reproducible methods for calibrating the backscattered electron signal for quantitative assessment of mineral content in bone. Scanning Microsc 4, 591-600, discussion 600-603 (1990)
    • (1990) Scanning Microsc , vol.4 , pp. 591-600
    • Boyce, T.M.1    Bloebaum, R.D.2    Bachus, K.N.3    Skedros, J.G.4
  • 5
    • 0007506435 scopus 로고    scopus 로고
    • Scanning electron microscopy of bone: Instrument, specimen, and issues
    • Boyde A, Jones SJ: Scanning electron microscopy of bone: instrument, specimen, and issues. Microsc Res Tech 33, 92-120 (1996)
    • (1996) Microsc Res Tech , vol.33 , pp. 92-120
    • Boyde, A.1    Jones, S.J.2
  • 6
    • 0032032059 scopus 로고    scopus 로고
    • Effect of estrogen suppression on the mineralization density of iliac crest biopsies in young women as assessed by backscattered electron imaging
    • Boyde A, Compston JE, Reeve J, Bell KL, Noble BS, Jones SJ, Loveridge N: Effect of estrogen suppression on the mineralization density of iliac crest biopsies in young women as assessed by backscattered electron imaging. Bone 22, 241-250 (1998)
    • (1998) Bone , vol.22 , pp. 241-250
    • Boyde, A.1    Compston, J.E.2    Reeve, J.3    Bell, K.L.4    Noble, B.S.5    Jones, S.J.6    Loveridge, N.7
  • 7
    • 0029152999 scopus 로고
    • Mineral density quantitation of the human cortical iliac crest by backscattered electron image analysis: Variations with age, sex, and degree of osteoarthritis
    • Boyde A, Jones SJ, Aerssens J, Dequeker J: Mineral density quantitation of the human cortical iliac crest by backscattered electron image analysis: Variations with age, sex, and degree of osteoarthritis. Bone 16, 619-627 (1995)
    • (1995) Bone , vol.16 , pp. 619-627
    • Boyde, A.1    Jones, S.J.2    Aerssens, J.3    Dequeker, J.4
  • 9
    • 0026816519 scopus 로고
    • Effect of temperature on radiation damage to aromatic organic molecules
    • Fryer JR, McConnell CH: Effect of temperature on radiation damage to aromatic organic molecules. Ultramicroscopy 40, 163-169 (1992)
    • (1992) Ultramicroscopy , vol.40 , pp. 163-169
    • Fryer, J.R.1    McConnell, C.H.2
  • 11
    • 0034485799 scopus 로고    scopus 로고
    • Thermal effects of the electron beam and implications of surface damage in the analysis of bone tissue
    • Holmes JL, Bachus KN, Bloebaum RD: Thermal effects of the electron beam and implications of surface damage in the analysis of bone tissue. Scanning 22, 243-248 (2000)
    • (2000) Scanning , vol.22 , pp. 243-248
    • Holmes, J.L.1    Bachus, K.N.2    Bloebaum, R.D.3
  • 12
    • 0002251039 scopus 로고
    • Specimen damage in the electron microscope
    • Van Nostrand Reinhold Company, New York
    • Isaacson M: Specimen damage in the electron microscope. Principles and Techniques of Electron Microscopy. Van Nostrand Reinhold Company, New York, (1977) 1-78
    • (1977) Principles and Techniques of Electron Microscopy , pp. 1-78
    • Isaacson, M.1
  • 13
    • 0031777488 scopus 로고    scopus 로고
    • Mineralisation density of human mandibular bone: Quantitative backscattered electron image analysis
    • Kingsmill VJ, Boyde A: Mineralisation density of human mandibular bone: Quantitative backscattered electron image analysis. J Anat 192 (Pt. 2), 245-256 (1998)
    • (1998) J Anat , vol.192 , Issue.PART 2 , pp. 245-256
    • Kingsmill, V.J.1    Boyde, A.2
  • 14
    • 0032486508 scopus 로고    scopus 로고
    • Comparison of human, primate, and canine femora: Implications for biomaterials testing in total hip replacement
    • Kuo TY, Skedros JG, Bloebaum RD: Comparison of human, primate, and canine femora: Implications for biomaterials testing in total hip replacement. J Biomed Mater Res 40, 3, 475-489 (1998)
    • (1998) J Biomed Mater Res , vol.40 , Issue.3 , pp. 475-489
    • Kuo, T.Y.1    Skedros, J.G.2    Bloebaum, R.D.3
  • 15
    • 5344266050 scopus 로고    scopus 로고
    • Bone mineralization density and femoral neck fragility
    • Loveridge N, Power J, Reeve J, Boyde A: Bone mineralization density and femoral neck fragility. Bone 35, 929-941 (2004)
    • (2004) Bone , vol.35 , pp. 929-941
    • Loveridge, N.1    Power, J.2    Reeve, J.3    Boyde, A.4
  • 17
    • 0018814812 scopus 로고
    • Aspects of microprobe analysis of mineralized tissues
    • Nicholson WA, Dempster DW: Aspects of microprobe analysis of mineralized tissues. Scan Electron Microsc 517-533 (1980)
    • (1980) Scan Electron Microsc , pp. 517-533
    • Nicholson, W.A.1    Dempster, D.W.2
  • 18
    • 0028882234 scopus 로고
    • A new scanning electron microscopy approach to the quantification of bone mineral distribution: Backscattered electron image grey-levels correlated to calcium Kα-line intensities
    • Roschger P, Plenk H, Jr., Klaushofer K, Eschberger J: A new scanning electron microscopy approach to the quantification of bone mineral distribution: Backscattered electron image grey-levels correlated to calcium Kα-line intensities. Scan Microsc 9, 75-88 (1995)
    • (1995) Scan Microsc , vol.9 , pp. 75-88
    • Roschger, P.1    Plenk Jr., H.2    Klaushofer, K.3    Eschberger, J.4
  • 19
    • 0031006173 scopus 로고    scopus 로고
    • Mineralization of cancellous bone after alendronate and sodium fluoride treatment: A quantitative backscattered electron imaging study on minipig ribs
    • Roschger P, Fratzl P, Klaushofer K, Rodan G: Mineralization of cancellous bone after alendronate and sodium fluoride treatment: a quantitative backscattered electron imaging study on minipig ribs. Bone 20, 393-397 (1997)
    • (1997) Bone , vol.20 , pp. 393-397
    • Roschger, P.1    Fratzl, P.2    Klaushofer, K.3    Rodan, G.4
  • 20
    • 17644445505 scopus 로고    scopus 로고
    • Validation of quantitative backscattered electron imaging for the measurement of mineral density distribution in human bone biopsies
    • Roschger P, Fratzl P, Eschberger J, Klaushofer K: Validation of quantitative backscattered electron imaging for the measurement of mineral density distribution in human bone biopsies. Bone 23, 319-326 (1998)
    • (1998) Bone , vol.23 , pp. 319-326
    • Roschger, P.1    Fratzl, P.2    Eschberger, J.3    Klaushofer, K.4
  • 21
    • 0020615624 scopus 로고
    • Cross-sectional geometry of Pecos Pueblo femora and tibiae - A biomechanical investigation: I. Method and general patterns of variation
    • Ruff CB and Hayes WC: Cross-sectional geometry of Pecos Pueblo femora and tibiae - A biomechanical investigation: I. Method and general patterns of variation. Am J Phys Anthrop 60, 359-381 (1983)
    • (1983) Am J Phys Anthrop , vol.60 , pp. 359-381
    • Ruff, C.B.1    Hayes, W.C.2
  • 22
    • 0028597536 scopus 로고
    • Parallel experience of two different laboratories with the initiator perkadox 16 for polymerization of methylmethacrylates
    • Sanderson C, Kitabayashi LR: Parallel experience of two different laboratories with the initiator perkadox 16 for polymerization of methylmethacrylates. J Histotechnol 17, 343-348 (1994)
    • (1994) J Histotechnol , vol.17 , pp. 343-348
    • Sanderson, C.1    Kitabayashi, L.R.2
  • 24
    • 0027398456 scopus 로고
    • Influence of mineral content and composition of graylevels in backscattered electron images of bone
    • Skedros JG, Bloebaum RD, Bachus KN, Boyce TM, Constantz B: Influence of mineral content and composition of graylevels in backscattered electron images of bone. J Biomed Mater Res 27, 57-64 (1993b)
    • (1993) J Biomed Mater Res , vol.27 , pp. 57-64
    • Skedros, J.G.1    Bloebaum, R.D.2    Bachus, K.N.3    Boyce, T.M.4    Constantz, B.5
  • 25
    • 25144435387 scopus 로고    scopus 로고
    • Cement lines of secondary osteons in human bone are not mineral deficient: New data in a historical perspective
    • in press
    • Skedros JG, Holmes JL, Vajda EG, Bloebaum RD: Cement lines of secondary osteons in human bone are not mineral deficient: New data in a historical perspective. Anatom Rec (in press) (2005)
    • (2005) Anatom Rec
    • Skedros, J.G.1    Holmes, J.L.2    Vajda, E.G.3    Bloebaum, R.D.4
  • 26
    • 0015009897 scopus 로고
    • Damage to biological samples caused by the electron beam during electron microscopy
    • Thach RE, Thach SS: Damage to biological samples caused by the electron beam during electron microscopy. Biophys 711, 204-210 (1971)
    • (1971) Biophys , vol.711 , pp. 204-210
    • Thach, R.E.1    Thach, S.S.2
  • 27
    • 0033143711 scopus 로고    scopus 로고
    • Primary difficulties in quantitative backscattered electron (BSE) imaging
    • Vajda EG, Skedros JG: Primary difficulties in quantitative backscattered electron (BSE) imaging. Bone 24, 619-621 (1999)
    • (1999) Bone , vol.24 , pp. 619-621
    • Vajda, E.G.1    Skedros, J.G.2
  • 28
    • 0030322493 scopus 로고    scopus 로고
    • Validation of energy dispersive x-ray spectrometry as a method to standardized backscattered electron images of bone
    • Vajda EG, Bloebaum RD and Skedros JG: Validation of energy dispersive x-ray spectrometry as a method to standardized backscattered electron images of bone. Cells Mater 6, 79-92 (1996)
    • (1996) Cells Mater , vol.6 , pp. 79-92
    • Vajda, E.G.1    Bloebaum, R.D.2    Skedros, J.G.3
  • 29
    • 0031761914 scopus 로고    scopus 로고
    • Errors in quantitative backscattered electron analysis of bone standardized by energy-dispersive x-ray spectrometry
    • Vajda EG, Skedros JG, Bloebaum RD: Errors in quantitative backscattered electron analysis of bone standardized by energy-dispersive x-ray spectrometry. Scanning 20, 527-535 (1998)
    • (1998) Scanning , vol.20 , pp. 527-535
    • Vajda, E.G.1    Skedros, J.G.2    Bloebaum, R.D.3
  • 30
    • 0033379887 scopus 로고    scopus 로고
    • Influence of topography and specimen preparation on backscattered electron images of bone
    • Vajda EG, Humphrey S, Skedros JG, Bloebaum RD: Influence of topography and specimen preparation on backscattered electron images of bone. Scanning 21, 379-387 (1999)
    • (1999) Scanning , vol.21 , pp. 379-387
    • Vajda, E.G.1    Humphrey, S.2    Skedros, J.G.3    Bloebaum, R.D.4
  • 32
    • 27344451711 scopus 로고
    • The analytical electron microscope, EMMA-4
    • Van Nostrand Reinhold Company, New York
    • Weavers BA: The analytical electron microscope, EMMA-4. In Principles and Techniques of Electron Microscopy. Van Nostrand Reinhold Company, New York, (1975) 174-244
    • (1975) Principles and Techniques of Electron Microscopy , pp. 174-244
    • Weavers, B.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.