Indication of the radiofrequency induced lesion size by pre-ablation measurements

Author keywords

Catheter ablation; Electrode contact; External cooling; Impedance; Irrigated tip; Power controlled ablation; Radiofrequency ablation; Temperature controlled ablation

Indexed keywords

ANIMAL TISSUE; ARTICLE; COOLING; CORRELATION ANALYSIS; ELECTRODE; ELECTRODERMAL RESPONSE; HEART ARRHYTHMIA; HEART LEFT VENTRICLE; HEART MUSCLE; IMPEDANCE; IN VITRO STUDY; NONHUMAN; PREDICTION; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; TEMPERATURE SENSITIVITY;

EID: 27144496975     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1016/j.eupc.2005.05.016     Document Type: Article
Times cited : (25)

References (41)
  • 1
    • 0027395909 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease
    • F. Morady M. Harvey S.J. Kalbfleisch R. El-Atassi H. Calkins J.J. Langberg Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease Circulation 87 1993 363-372
    • (1993) Circulation , vol.87 , pp. 363-372
    • Morady, F.1    Harvey, M.2    Kalbfleisch, S.J.3    El-Atassi, R.4    Calkins, H.5    Langberg, J.J.6
  • 2
    • 0026605085 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease
    • L.S. Klein H.T. Shih F.K. Hackett D.P. Zipes W.M. Miles Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease Circulation 85 1992 1666-1674
    • (1992) Circulation , vol.85 , pp. 1666-1674
    • Klein, L.S.1    Shih, H.T.2    Hackett, F.K.3    Zipes, D.P.4    Miles, W.M.5
  • 3
    • 0029422273 scopus 로고
    • The ablative techniques from surgery to catheter ablation in the treatment of cardiac arrhythmias: A 20 year experience
    • G. Fontaine The ablative techniques from surgery to catheter ablation in the treatment of cardiac arrhythmias: A 20 year experience Acta Cardiol 50 1995 467-468
    • (1995) Acta Cardiol. , vol.50 , pp. 467-468
    • Fontaine, G.1
  • 4
    • 0028909117 scopus 로고
    • Temperature-guided radiofreqeuncy catheter ablation of slow pathway in atrioventricular nodal reentrant tachycardia
    • Y.S. Choi K.S. Sohn D.W. Sohn B.H. Oh M.M. Lee Y.B. Park et al. Temperature-guided radiofreqeuncy catheter ablation of slow pathway in atrioventricular nodal reentrant tachycardia Am Heart J 129 1995 392-394
    • (1995) Am. Heart J. , vol.129 , pp. 392-394
    • Choi, Y.S.1    Sohn, K.S.2    Sohn, D.W.3    Oh, B.H.4    Lee, M.M.5    Park, Y.B.6
  • 5
    • 0029875913 scopus 로고    scopus 로고
    • Temperature-controlled radiofrequency catheter ablation of manifest accessory pathways
    • S. Willems X. Chen H. Kottkamp G. Hindricks W. Haverkamp B. Rotman et al. Temperature-controlled radiofrequency catheter ablation of manifest accessory pathways Eur Heart J 17 1996 445-452
    • (1996) Eur. Heart J. , vol.17 , pp. 445-452
    • Willems, S.1    Chen, X.2    Kottkamp, H.3    Hindricks, G.4    Haverkamp, W.5    Rotman, B.6
  • 6
    • 0033956518 scopus 로고    scopus 로고
    • Popping phenomena in temperature-controlled radiofrequency ablation: When and why do they occur?
    • O. Eick B. Gerritse B. Schumacher Popping phenomena in temperature-controlled radiofrequency ablation: When and why do they occur? Pacing Clin Electrophysiol 23 2000 253-258
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 253-258
    • Eick, O.1    Gerritse, B.2    Schumacher, B.3
  • 7
    • 0025293526 scopus 로고
    • Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
    • D.E. Haines D.D. Watson A.F. Verow Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model Circ Res 67 1990 124-129
    • (1990) Circ. Res. , vol.67 , pp. 124-129
    • Haines, D.E.1    Watson, D.D.2    Verow, A.F.3
  • 8
    • 0025095887 scopus 로고
    • Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
    • J.J. Langberg M.A. Lee M.C. Chin M. Rosenqvist Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo Pacing Clin Electrophysiol 13 1990 1242-1248
    • (1990) Pacing Clin. Electrophysiol. , vol.13 , pp. 1242-1248
    • Langberg, J.J.1    Lee, M.A.2    Chin, M.C.3    Rosenqvist, M.4
  • 9
    • 0027295050 scopus 로고
    • Temperature-guided radiofrequency catheter ablation with very large distal electrodes
    • J.J. Langberg M. Gallagher S.A. Strickberger O. Amirana Temperature-guided radiofrequency catheter ablation with very large distal electrodes Circulation 88 1993 245-249
    • (1993) Circulation , vol.88 , pp. 245-249
    • Langberg, J.J.1    Gallagher, M.2    Strickberger, S.A.3    Amirana, O.4
  • 10
    • 15444359497 scopus 로고    scopus 로고
    • Why a large tip electrode makes a deeper radiofrequency lesion: Effects of increase in electrode cooling and electrode-tissue interface area
    • K. Otomo W.S. Yamanashi C. Tondo M. Antz J. Bussey J.V. Pitha et al. Why a large tip electrode makes a deeper radiofrequency lesion: Effects of increase in electrode cooling and electrode-tissue interface area J Cardiovasc Electrophysiol 9 1998 47-54
    • (1998) J. Cardiovasc. Electrophysiol. , vol.9 , pp. 47-54
    • Otomo, K.1    Yamanashi, W.S.2    Tondo, C.3    Antz, M.4    Bussey, J.5    Pitha, J.V.6
  • 11
    • 0032903237 scopus 로고    scopus 로고
    • Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium. Impact of ablation site, electrode size and convective cooling
    • H.H. Petersen X. Chen A. Pietersen J.H. Svendsen S. Haunsø Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium. Impact of ablation site, electrode size and convective cooling Circulation 99 1999 319-325
    • (1999) Circulation , vol.99 , pp. 319-325
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunsø, S.5
  • 12
    • 0026325244 scopus 로고
    • Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery
    • D.E. Haines Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery J Cardiovasc Electrophysiol 2 1991 509-515
    • (1991) J. Cardiovasc. Electrophysiol. , vol.2 , pp. 509-515
    • Haines, D.E.1
  • 13
    • 0031793610 scopus 로고    scopus 로고
    • Comparison of standard and irrigated radiofrequency ablation in the canine ventricle
    • L. Skrumeda R. Mehra Comparison of standard and irrigated radiofrequency ablation in the canine ventricle J Cardiovasc Electrophysiol 9 1998 1196-1205
    • (1998) J. Cardiovasc. Electrophysiol. , vol.9 , pp. 1196-1205
    • Skrumeda, L.1    Mehra, R.2
  • 14
    • 0036224441 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation using cooled electrode: Impact of irrigation flow rate and catheter contact pressure on lesion dimensions
    • C. Weiss M. Antz O. Eick K. Eshagzaiy T. Meinertz S. Willems Radiofrequency catheter ablation using cooled electrode: Impact of irrigation flow rate and catheter contact pressure on lesion dimensions Pacing Clin Electrophysiol 25 2002 463-469
    • (2002) Pacing Clin. Electrophysiol. , vol.25 , pp. 463-469
    • Weiss, C.1    Antz, M.2    Eick, O.3    Eshagzaiy, K.4    Meinertz, T.5    Willems, S.6
  • 15
    • 0029559129 scopus 로고
    • Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart
    • R. Ruffy M.A. Imran D.J. Santel J.M. Wharton Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart J Cardiovasc Electrophysiol 6 1995 1089-1096
    • (1995) J. Cardiovasc. Electrophysiol. , vol.6 , pp. 1089-1096
    • Ruffy, R.1    Imran, M.A.2    Santel, D.J.3    Wharton, J.M.4
  • 16
    • 0031895674 scopus 로고    scopus 로고
    • Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate
    • H.H. Petersen X. Chen A. Pietersen J.H. Svendsen S. Haunsø Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate J Cardiovasc Electrophysiol 9 1998 409-414
    • (1998) J. Cardiovasc. Electrophysiol. , vol.9 , pp. 409-414
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunsø, S.5
  • 17
    • 0024319513 scopus 로고
    • Coagulation of ventricular myocardium using radiofrequency alternating current: Bio-physical aspects and experimental findings
    • W. Haverkamp G. Hindricks H. Gülker U. Rissel W. Pfennings M. Borggrefe et al. Coagulation of ventricular myocardium using radiofrequency alternating current: Bio-physical aspects and experimental findings Pacing Clin Electrophysiol 12 1989 187-195
    • (1989) Pacing Clin. Electrophysiol. , vol.12 , pp. 187-195
    • Haverkamp, W.1    Hindricks, G.2    Gülker, H.3    Rissel, U.4    Pfennings, W.5    Borggrefe, M.6
  • 18
    • 0027316390 scopus 로고
    • The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring
    • D.E. Haines The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring Pacing Clin Electrophysiol 16 1993 586-591
    • (1993) Pacing Clin. Electrophysiol. , vol.16 , pp. 586-591
    • Haines, D.E.1
  • 19
    • 0024805617 scopus 로고
    • Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature
    • G. Hindricks W. Haverkamp H. Gülker U. Rissel T. Budde K.D. Richter et al. Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature Eur Heart J 10 1989 972-984
    • (1989) Eur. Heart J. , vol.10 , pp. 972-984
    • Hindricks, G.1    Haverkamp, W.2    Gülker, H.3    Rissel, U.4    Budde, T.5    Richter, K.D.6
  • 20
  • 21
    • 0030953697 scopus 로고    scopus 로고
    • Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro
    • E. Kongsgaard T. Steen Ø. Jensen H. Aass J.P. Amlie Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro Pacing Clin Electrophysiol 20 1997 1252-1260
    • (1997) Pacing Clin. Electrophysiol. , vol.20 , pp. 1252-1260
    • Kongsgaard, E.1    Steen, T.2    Jensen, Ø.3    Aass, H.4    Amlie, J.P.5
  • 22
    • 0030425347 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor
    • O.G. Anfinsen E. Kongsgaard H. Aass J.P. Amlie Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor Eur J Cardiac Pacing Electrophysiol 6 1996 195-203
    • (1996) Eur. J. Cardiac. Pacing Electrophysiol. , vol.6 , pp. 195-203
    • Anfinsen, O.G.1    Kongsgaard, E.2    Aass, H.3    Amlie, J.P.4
  • 23
    • 0043202575 scopus 로고    scopus 로고
    • Can lesion size during radiofrequency ablation be predicted by the temperature rise to a low power test pulse in vitro
    • H.H. Petersen J.H. Svendsen Can lesion size during radiofrequency ablation be predicted by the temperature rise to a low power test pulse in vitro Pacing Clin Electrophysiol 26 2003 1653-1659
    • (2003) Pacing Clin. Electrophysiol. , vol.26 , pp. 1653-1659
    • Petersen, H.H.1    Svendsen, J.H.2
  • 24
    • 0033208610 scopus 로고    scopus 로고
    • Temperature-controlled radiofrequency ablation of cardiac tissue: An in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling
    • H.H. Petersen X. Chen A. Pietersen J.H. Svendsen S. Haunsø Temperature-controlled radiofrequency ablation of cardiac tissue: An in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling J Interv Card Electrophysiol 3 2000 257-262
    • (2000) J. Interv. Card. Electrophysiol. , vol.3 , pp. 257-262
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunsø, S.5
  • 26
    • 0031770673 scopus 로고    scopus 로고
    • The LETR-principle: A novel method to assess electrode-tissue contact in radiofrequency ablation
    • O. Eick F.H. Wittkampf T. Bronneberg B. Schumacher The LETR-principle: A novel method to assess electrode-tissue contact in radiofrequency ablation J Cardiovasc Electrophysiol 9 1998 1180-1185
    • (1998) J. Cardiovasc. Electrophysiol. , vol.9 , pp. 1180-1185
    • Eick, O.1    Wittkampf, F.H.2    Bronneberg, T.3    Schumacher, B.4
  • 27
    • 0022875997 scopus 로고
    • Factors influencing trans-catheter radiofrequency ablation of the myocardium
    • R.H. Hoyt S.K.S. Huang F.I. Marcus R.C. Odell Factors influencing trans-catheter radiofrequency ablation of the myocardium J Appl Cardiol 1 1986 469-486
    • (1986) J. Appl. Cardiol. , vol.1 , pp. 469-486
    • Hoyt, R.H.1    Huang, S.K.S.2    Marcus, F.I.3    Odell, R.C.4
  • 28
    • 0033963508 scopus 로고    scopus 로고
    • Microwave ablation using a spiral antenna in a porcine thigh muscle preparation: In vivo assessment of temperature profile and lesion geometry
    • 3d
    • B. Vanderbrink Z. Gu V. Rodriguez M. Link M. Homoud M3d Estes et al. Microwave ablation using a spiral antenna in a porcine thigh muscle preparation: In vivo assessment of temperature profile and lesion geometry J Cardiovasc Electrophysiol 11 2000 193-198
    • (2000) J. Cardiovasc. Electrophysiol. , vol.11 , pp. 193-198
    • Vanderbrink, B.1    Gu, Z.2    Rodriguez, V.3    Link, M.4    Homoud, M.5    Estes, M.6
  • 29
    • 0033063965 scopus 로고    scopus 로고
    • Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle
    • S. Chugh R.C. Chan S.B. Johnson D.L. Packer Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle Pacing Clin Electrophysiol 22 1999 413-420
    • (1999) Pacing Clin. Electrophysiol. , vol.22 , pp. 413-420
    • Chugh, S.1    Chan, R.C.2    Johnson, S.B.3    Packer, D.L.4
  • 30
    • 0036162048 scopus 로고    scopus 로고
    • The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium
    • R.C. Chan S.B. Johnson J.B. Seward D.L. Packer The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium Pacing Clin Electrophysiol 25 2002 4-13
    • (2002) Pacing Clin. Electrophysiol. , vol.25 , pp. 4-13
    • Chan, R.C.1    Johnson, S.B.2    Seward, J.B.3    Packer, D.L.4
  • 32
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation and standard temperature-controlled ablation
    • H.H. Petersen X. Chen A. Pietersen J.H. Svendsen S. Haunsø Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation and standard temperature-controlled ablation Pacing Clin Electrophysiol 23 2000 8-17
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunsø, S.5
  • 33
    • 0037357279 scopus 로고    scopus 로고
    • Tissue temperature-controlled radiofrequency ablation
    • O. Eick D. Bierbaum Tissue temperature-controlled radiofrequency ablation Pacing Clin Electrophysiol 26 2003 725-730
    • (2003) Pacing Clin. Electrophysiol. , vol.26 , pp. 725-730
    • Eick, O.1    Bierbaum, D.2
  • 34
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • H. Nakagawa W.S. Yamanashi J.V. Pitha M. Arruda X. Wang K. Ohtomo et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation Circulation 91 1995 2264-2273
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3    Arruda, M.4    Wang, X.5    Ohtomo, K.6
  • 36
    • 27144505783 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip ablation in the temperature controlled and the power controlled mode
    • [Abstract]
    • H.H. Petersen X. Chen A. Pietersen J.H. Svendsen S. Haunsø Tissue temperatures and lesion size during irrigated tip ablation in the temperature controlled and the power controlled mode Arch Mal Coeur 91 1998 99 [Abstract]
    • (1998) Arch. Mal. Coeur. , vol.91 , pp. 99
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunsø, S.5
  • 37
    • 27144431714 scopus 로고    scopus 로고
    • Control of lesion size by setting a target temperature determined from a pre-ablation low power test pulse during in vivo radiofrequency ablation
    • [Abstract]
    • N. Stagegaard H.H. Petersen L. Ramlose X. Chen J.H. Svendsen Control of lesion size by setting a target temperature determined from a pre-ablation low power test pulse during in vivo radiofrequency ablation Eur Heart J 24 2003 592 [Abstract]
    • (2003) Eur. Heart J. , vol.24 , pp. 592
    • Stagegaard, N.1    Petersen, H.H.2    Ramlose, L.3    Chen, X.4    Svendsen, J.H.5
  • 38
    • 0034513779 scopus 로고    scopus 로고
    • Electrode impedance: An indicator of electrode-tissue contact and lesion dimensions during linear ablation
    • X. Zheng G. Walcott J. Hall D. Rollins W. Smith G.N. Kay et al. Electrode impedance: An indicator of electrode-tissue contact and lesion dimensions during linear ablation J Interv Card Electrophysiol 4 2000 645-654
    • (2000) J. Interv. Card. Electrophysiol. , vol.4 , pp. 645-654
    • Zheng, X.1    Walcott, G.2    Hall, J.3    Rollins, D.4    Smith, W.5    Kay, G.N.6
  • 39
    • 0036174409 scopus 로고    scopus 로고
    • Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation
    • H. Cao S. Tungjitkusolmun Y. Choy J. Tsai J. Webster Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation IEEE Trans Biomed Eng 49 2002 247-253
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 247-253
    • Cao, H.1    Tungjitkusolmun, S.2    Choy, Y.3    Tsai, J.4    Webster, J.5
  • 40
    • 0029320891 scopus 로고
    • Factors influencing impedance during radiofrequency ablation in humans
    • D. Wang J.E. Hulse E.P. Walsh J.P. Saul Factors influencing impedance during radiofrequency ablation in humans Chin Med J 108 1995 450-455
    • (1995) Chin. Med. J. , vol.108 , pp. 450-455
    • Wang, D.1    Hulse, J.E.2    Walsh, E.P.3    Saul, J.P.4
  • 41


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.