메뉴 건너뛰기




Volumn 9, Issue 4, 1998, Pages 409-414

Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate

Author keywords

Catheter ablation; Cooled tip electrode; Radiofrequency ablation; Ventricular arrhythmias

Indexed keywords

SODIUM CHLORIDE;

EID: 0031895674     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8167.1998.tb00928.x     Document Type: Article
Times cited : (60)

References (26)
  • 1
    • 0027295050 scopus 로고
    • Temperature-guided radiofrequency catheter ablation with very large distal electrodes
    • Langberg JJ, Gallugher M, Strickberger SA, et al: Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993;88: 245-249.
    • (1993) Circulation , vol.88 , pp. 245-249
    • Langberg, J.J.1    Gallugher, M.2    Strickberger, S.A.3
  • 2
    • 0003302270 scopus 로고
    • The biophysics and pathophysiology of lesion formation during radiofrequency catheter ablation
    • Zipes DP. Julife J, eds: WB Saunders, Philadelphia
    • Haines DE: The biophysics and pathophysiology of lesion formation during radiofrequency catheter ablation. In Zipes DP. Julife J, eds: Cardiac Electrophysiology: From Cell to Bedside. Second Edition. WB Saunders, Philadelphia, 1995, pp. 1442-1452.
    • (1995) Cardiac Electrophysiology: From Cell to Bedside. Second Edition , pp. 1442-1452
    • Haines, D.E.1
  • 3
    • 0026605085 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart diseuse
    • Klein LS, Shih HT, Hackett FK, et al: Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart diseuse. Circulation 1992;85:1666-1674.
    • (1992) Circulation , vol.85 , pp. 1666-1674
    • Klein, L.S.1    Shih, H.T.2    Hackett, F.K.3
  • 4
    • 0027395909 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease
    • Morady F, Harvey M, Kalbfleisch SJ, et al: Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease. Circulation 1993;87:363-372.
    • (1993) Circulation , vol.87 , pp. 363-372
    • Morady, F.1    Harvey, M.2    Kalbfleisch, S.J.3
  • 5
    • 0028859230 scopus 로고
    • Catheter ablation of ventricular tachycardia
    • Daoud E, Morady F: Catheter ablation of ventricular tachycardia. Curr Opin Cardiol 1995;10:21-25.
    • (1995) Curr Opin Cardiol , vol.10 , pp. 21-25
    • Daoud, E.1    Morady, F.2
  • 6
    • 0342632854 scopus 로고
    • NASPE survey on catheter ablation
    • Scheinman MM: NASPE survey on catheter ablation. PACE 1995;18:1474-1478.
    • (1995) PACE , vol.18 , pp. 1474-1478
    • Scheinman, M.M.1
  • 7
    • 9544220610 scopus 로고
    • Treatment of ventricular tachycardia by transcatheter radiofrequency ablation in patients with ischemic heart disease
    • Kim YH, Sosa-Suarez G, Trouton TG, et al: Treatment of ventricular tachycardia by transcatheter radiofrequency ablation in patients with ischemic heart disease. Circulation 1994;89:1094-1102.
    • (1994) Circulation , vol.89 , pp. 1094-1102
    • Kim, Y.H.1    Sosa-Suarez, G.2    Trouton, T.G.3
  • 9
    • 0002543312 scopus 로고
    • The pathophysiology of radiofrequency lesion formation
    • Zipes DP, ed. Futura Publishing Co., Inc., Amonk, NY
    • Haines DE: The pathophysiology of radiofrequency lesion formation. In Zipes DP, ed. Catheter Ablation of Arrhythmias. Futura Publishing Co., Inc., Amonk, NY, 1994, pp. 105-126.
    • (1994) Catheter Ablation of Arrhythmias , pp. 105-126
    • Haines, D.E.1
  • 10
    • 0028877525 scopus 로고
    • Biophysics and pathology of catheter energy delivery systems
    • Nuth S, Haines DE: Biophysics and pathology of catheter energy delivery systems. Prog Cardiovase Dis 1995;37:185-204.
    • (1995) Prog Cardiovase Dis , vol.37 , pp. 185-204
    • Nuth, S.1    Haines, D.E.2
  • 11
    • 0000467442 scopus 로고    scopus 로고
    • Impact of ablation locution on impedance pop occurrence with irrigated tip energy delivery in dogs
    • Packer DL, Johnson SB: Impact of ablation locution on impedance pop occurrence with irrigated tip energy delivery in dogs. (Abstract) PACE 1997;20:1565.
    • (1997) PACE , vol.20 , pp. 1565
    • Packer, D.L.1    Johnson, S.B.2
  • 12
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV, et al: Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995;91:2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 13
    • 0028814037 scopus 로고
    • Myocardial temperature response during rudiofrequency catheter ablation
    • Wittkampf FH, Simmers TA, Hauer RN, et al: Myocardial temperature response during rudiofrequency catheter ablation. PACE 1995;18:307-317.
    • (1995) PACE , vol.18 , pp. 307-317
    • Wittkampf, F.H.1    Simmers, T.A.2    Hauer, R.N.3
  • 14
    • 0024364286 scopus 로고
    • Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
    • Haines DE, Watson DD: Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. PACE 1989;12:962-976.
    • (1989) PACE , vol.12 , pp. 962-976
    • Haines, D.E.1    Watson, D.D.2
  • 15
    • 0024319513 scopus 로고
    • Coagulation of ventricular myocardium using radiofrequency alternating current: Bio-physical aspects and experimental findings
    • Haverkamp W, Hindricks G, Gulker H, et al: Coagulation of ventricular myocardium using radiofrequency alternating current: Bio-physical aspects and experimental findings. PACE 1989;12(Pt II):187-195.
    • (1989) PACE , vol.12 , Issue.2 PART , pp. 187-195
    • Haverkamp, W.1    Hindricks, G.2    Gulker, H.3
  • 16
    • 0024805617 scopus 로고
    • Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature
    • Hindricks G, Haverkamp W, Gülker H, et al: Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature. Eur Heart J 1989;10:972-984.
    • (1989) Eur Heart J , vol.10 , pp. 972-984
    • Hindricks, G.1    Haverkamp, W.2    Gülker, H.3
  • 17
    • 0000029024 scopus 로고    scopus 로고
    • Myocardial heating patterns during radiofrequency energy delivery via an irrigated electrode
    • Demazumder DBS, Kallash HL, Schwartzman D: Myocardial heating patterns during radiofrequency energy delivery via an irrigated electrode. (Abstract) PACE 1997;20(Pt II):1203.
    • (1997) PACE , vol.20 , Issue.2 PART , pp. 1203
    • Demazumder, D.B.S.1    Kallash, H.L.2    Schwartzman, D.3
  • 18
    • 0000160568 scopus 로고    scopus 로고
    • Comparison of different electrodes for radiofrequency ablation of myocardium using saline irrigation
    • Demazumder DBS, Kallash HL, Schwartzman D: Comparison of different electrodes for radiofrequency ablation of myocardium using saline irrigation. (Abstract) PACE 1997;20(Pt II):1076.
    • (1997) PACE , vol.20 , Issue.2 PART , pp. 1076
    • Demazumder, D.B.S.1    Kallash, H.L.2    Schwartzman, D.3
  • 19
    • 0025299994 scopus 로고
    • Experimental verification of bioheat transfer theories: Measurements of temperature profiles around large artificial vessels in perfused tissue
    • Crezee J, Lagendijk JJW: Experimental verification of bioheat transfer theories: Measurements of temperature profiles around large artificial vessels in perfused tissue. Phys Med Biol 1990;35:905-923.
    • (1990) Phys Med Biol , vol.35 , pp. 905-923
    • Crezee, J.1    Lagendijk, J.J.W.2
  • 20
    • 0028240838 scopus 로고
    • Effects of radiofrequency catheter ablation on regional myocardial blood flow. Possible mechanism for late electrophysiological outcome
    • Nath S, Whayne JG, Kaul S, et al: Effects of radiofrequency catheter ablation on regional myocardial blood flow. Possible mechanism for late electrophysiological outcome. Circulation 1994;89:2667-2672.
    • (1994) Circulation , vol.89 , pp. 2667-2672
    • Nath, S.1    Whayne, J.G.2    Kaul, S.3
  • 21
    • 0008943783 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of ventricular myocardium using a cooled catheter system
    • Dorwarth U, Mattke S, Remp T, et al: Radiofrequency catheter ablation of ventricular myocardium using a cooled catheter system. (Abstract) Eur Heart J 1996;17:270.
    • (1996) Eur Heart J , vol.17 , pp. 270
    • Dorwarth, U.1    Mattke, S.2    Remp, T.3
  • 22
    • 0008893193 scopus 로고    scopus 로고
    • Creation of large lesions without craters using irrigated RF ablation
    • Skrumeda L, Mehra R: Creation of large lesions without craters using irrigated RF ablation. (Abstract) PACE 1997;20(Pt II):1206.
    • (1997) PACE , vol.20 , Issue.2 PART , pp. 1206
    • Skrumeda, L.1    Mehra, R.2
  • 23
    • 0029000109 scopus 로고
    • Use of the saline infusion electrode catheter for improved energy delivery and increased lesion size in radiofrequency catheter ablation
    • Mittleman RS, Huang SKS, de Guzman WT, et al: Use of the saline infusion electrode catheter for improved energy delivery and increased lesion size in radiofrequency catheter ablation. PACE 1995;18:1022-1027.
    • (1995) PACE , vol.18 , pp. 1022-1027
    • Mittleman, R.S.1    Huang, S.K.S.2    De Guzman, W.T.3
  • 24
    • 0001713779 scopus 로고    scopus 로고
    • External cooling of ablation catheter using an intravascular sheath increases in-vitro lesion size and applied power
    • Alexander ME, Tanel RE, Hampton DA, et al: External cooling of ablation catheter using an intravascular sheath increases in-vitro lesion size and applied power. (Abstract) Phys Med Biol 1997;20:1087.
    • (1997) Phys Med Biol , vol.20 , pp. 1087
    • Alexander, M.E.1    Tanel, R.E.2    Hampton, D.A.3
  • 25
    • 7144221221 scopus 로고    scopus 로고
    • Voltage and duration dependence of radiofrequency lesion generation in the canine ventricle with an irrigation tip catheter
    • Packer DL, Johnson SB: Voltage and duration dependence of radiofrequency lesion generation in the canine ventricle with an irrigation tip catheter. (Abstract) Eur JCPE 1996;6:71.
    • (1996) Eur JCPE , vol.6 , pp. 71
    • Packer, D.L.1    Johnson, S.B.2
  • 26
    • 0008924495 scopus 로고    scopus 로고
    • Temperature controlled ablation with irrigated electrodes
    • Wittkampf FH, Nakagawa H, Derksen R, et al: Temperature controlled ablation with irrigated electrodes. (Abstract) PACE 1997;20(Pt II):1206.
    • (1997) PACE , vol.20 , Issue.2 PART , pp. 1206
    • Wittkampf, F.H.1    Nakagawa, H.2    Derksen, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.