Volumn 20, Issue 12 I, 1997, Pages 2899-2910

The effects of electrode-tissue contact on radiofrequency lesion generation

Author keywords

Ablation; Contact; Impedance; Radiofrequency; Temperature

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CATHETER ABLATION; DEFIBRILLATION; DOG; HEART ARRHYTHMIA; IMPEDANCE; MICROELECTRODE; NONHUMAN; RADIOFREQUENCY; TEMPERATURE DEPENDENCE;

EID: 0031436188     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1997.tb05458.x     Document Type: Article
Times cited : (143)

References (22)
  • 1
    • 0027316390 scopus 로고
    • The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring
    • Haines D. The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring. PACE 1993; 16:587-591.
    • (1993) PACE , vol.16 , pp. 587-591
    • Haines, D.1
  • 2
    • 0024805617 scopus 로고
    • Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature
    • Hindricks G, Haverkamp W, Gulker H, et al. Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature. Eur Heart J 1989; 10:972-984.
    • (1989) Eur Heart J , vol.10 , pp. 972-984
    • Hindricks, G.1    Haverkamp, W.2    Gulker, H.3
  • 3
    • 0027503526 scopus 로고
    • Temperature-controlled radiofrequency catheter ablation of AV conduction: First clinical experience
    • Hoffmann E, Mattke JS, Dorwarth U, et al. Temperature-controlled radiofrequency catheter ablation of AV conduction: First clinical experience. Eur Heart J 1993; 14:57-64.
    • (1993) Eur Heart J , vol.14 , pp. 57-64
    • Hoffmann, E.1    Mattke, J.S.2    Dorwarth, U.3
  • 4
    • 0024433306 scopus 로고
    • Determinants of impedance rise during catheter ablation of bovine myocardium with radiofrequency energy
    • Ring M, Huang S, Gorman G, et al. Determinants of impedance rise during catheter ablation of bovine myocardium with radiofrequency energy. PACE 1989; 12:1502-1513.
    • (1989) PACE , vol.12 , pp. 1502-1513
    • Ring, M.1    Huang, S.2    Gorman, G.3
  • 5
    • 0027503526 scopus 로고
    • Temperature-controlled radiofrequency catheter ablation of AV conduction: First clinical experience
    • Hoffmann E, Mattke S, Dorwarth U, et al. Temperature-controlled radiofrequency catheter ablation of AV conduction: First clinical experience. Eur Heart J 1993; 14(1):57-64.
    • (1993) Eur Heart J , vol.14 , Issue.1 , pp. 57-64
    • Hoffmann, E.1    Mattke, S.2    Dorwarth, U.3
  • 6
    • 0024386794 scopus 로고
    • Radiofrequency ablation of ventricular myocardium using active fixation and passive contact catheter delivery systems
    • An H, Saksena S, Janssen M, et al. Radiofrequency ablation of ventricular myocardium using active fixation and passive contact catheter delivery systems. Am Heart J 1989; 118:69-77.
    • (1989) Am Heart J , vol.118 , pp. 69-77
    • An, H.1    Saksena, S.2    Janssen, M.3
  • 7
    • 0026487862 scopus 로고
    • Temperature response in radiofrequency catheter ablation
    • Wittkampf F. Temperature response in radiofrequency catheter ablation. Circulation 1992; 86: 1648-1650.
    • (1992) Circulation , vol.86 , pp. 1648-1650
    • Wittkampf, F.1
  • 8
    • 0024991053 scopus 로고
    • Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium
    • Haines D, Verow A. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Circulation 1990; 82: 1034-1038.
    • (1990) Circulation , vol.82 , pp. 1034-1038
    • Haines, D.1    Verow, A.2
  • 9
    • 0022875997 scopus 로고
    • Factors influencing trans-catheter radiofrequency ablation of the myocardium
    • Hoyt R, Huang S, Marcus F, et al. Factors influencing trans-catheter radiofrequency ablation of the myocardium. J App Cardiol 1986; 1:469-486.
    • (1986) J App Cardiol , vol.1 , pp. 469-486
    • Hoyt, R.1    Huang, S.2    Marcus, F.3
  • 10
    • 0024363035 scopus 로고
    • The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro
    • Blouin L, Marcus F. The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro. PACE 1989; 12:136-143.
    • (1989) PACE , vol.12 , pp. 136-143
    • Blouin, L.1    Marcus, F.2
  • 11
    • 0025284557 scopus 로고
    • Radio-frequency ablation: Effect of voltage and pulse duration on canine myocardium
    • Bardy G, Sawyer P, Johnson G, et al. Radio-frequency ablation: Effect of voltage and pulse duration on canine myocardium. Am J Physiol 1990; 258:H1899-H1905.
    • (1990) Am J Physiol , vol.258
    • Bardy, G.1    Sawyer, P.2    Johnson, G.3
  • 12
    • 0024433096 scopus 로고
    • Control of radiofrequency lesion size by power regulation
    • Wittkampf F, Hauer R, Robles de Medina E. Control of radiofrequency lesion size by power regulation. Circulation 1989; 80:962-968.
    • (1989) Circulation , vol.80 , pp. 962-968
    • Wittkampf, F.1    Hauer, R.2    Robles De Medina, E.3
  • 13
    • 0026458157 scopus 로고
    • Biophysical parameters of radiofrequency catheter ablation
    • Hoffman E, Haberl R, Pulter R, et al. Biophysical parameters of radiofrequency catheter ablation. International J Cardiol 1992; 13:213-222.
    • (1992) International J Cardiol , vol.13 , pp. 213-222
    • Hoffman, E.1    Haberl, R.2    Pulter, R.3
  • 14
    • 0026453209 scopus 로고
    • Temperature monitoring during radiofrequency catheter ablation of accessory pathways
    • Langberg J, Calkins H, El-Atassi R, et al. Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation 1992; 86:1469-1474.
    • (1992) Circulation , vol.86 , pp. 1469-1474
    • Langberg, J.1    Calkins, H.2    El-Atassi, R.3
  • 15
    • 28144445271 scopus 로고
    • Impedance changes during catheter ablation by radiofrequency energy: A potential method for monitoring efficacy of lesion generation
    • Grogan EW, Nellis SH, Subramanian R. Impedance changes during catheter ablation by radiofrequency energy: A potential method for monitoring efficacy of lesion generation. J Am Coll Cardiol 1987;9:95A.
    • (1987) J Am Coll Cardiol , vol.9
    • Grogan, E.W.1    Nellis, S.H.2    Subramanian, R.3
  • 16
    • 0026543004 scopus 로고
    • Impedance monitoring during radiofrequency catheter ablation in humans
    • Harvey M, Kim Y, Sousa J, et al. Impedance monitoring during radiofrequency catheter ablation in humans. PACE 1992; 15:22-27.
    • (1992) PACE , vol.15 , pp. 22-27
    • Harvey, M.1    Kim, Y.2    Sousa, J.3
  • 17
    • 0000368429 scopus 로고
    • Does impedance monitoring during radiofrequency catheter ablation reduce the risk of impedance rise?
    • Hoffman E, Remp T, Gerth A, et al. Does impedance monitoring during radiofrequency catheter ablation reduce the risk of impedance rise? (abstract) Circulation 1993; 88(Suppl.):I165.
    • (1993) Circulation , vol.88 , Issue.SUPPL.
    • Hoffman, E.1    Remp, T.2    Gerth, A.3
  • 18
    • 9244247338 scopus 로고
    • A randomized comparison of impedance and temperature monitoring during accessory pathway ab-lation
    • Strickberger S, Hummel J, Vorperian V, et al. A randomized comparison of impedance and temperature monitoring during accessory pathway ab-lation. Circulation 1993; 88(4):I-295.
    • (1993) Circulation , vol.88 , Issue.4
    • Strickberger, S.1    Hummel, J.2    Vorperian, V.3
  • 19
    • 0027197548 scopus 로고
    • Physics and engineering of transcatheter cardiac tissue ablation
    • Avitall B, Khan M, Krum D, et al. Physics and engineering of transcatheter cardiac tissue ablation. J Am Coll Cardiol 1993; 22:921-932.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 921-932
    • Avitall, B.1    Khan, M.2    Krum, D.3
  • 20
    • 0028329880 scopus 로고
    • In vivo ventricular lesion growth in radiofrequency catheter ablation
    • Simmers T, Wittkampf F, Hauer R, et al. In vivo ventricular lesion growth in radiofrequency catheter ablation. PACE 1994; 17-II:523-31.
    • (1994) PACE , vol.17 , Issue.2 , pp. 523-531
    • Simmers, T.1    Wittkampf, F.2    Hauer, R.3
  • 21
    • 0028812669 scopus 로고
    • Estimation of temperature during radiofrequency catheter ablation using impedance measurements
    • Hartung W, Burton M, Deam A, et al. Estimation of temperature during radiofrequency catheter ablation using impedance measurements. PACE 1995; 18:2017-2021.
    • (1995) PACE , vol.18 , pp. 2017-2021
    • Hartung, W.1    Burton, M.2    Deam, A.3
  • 22
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi W, Pitha J, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature in a canine thigh muscle preparation. Circulation 1995; 91(8):2264-2273.
    • (1995) Circulation , vol.91 , Issue.8 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.2    Pitha, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.