메뉴 건너뛰기




Volumn 22, Issue 3, 1999, Pages 413-420

Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle

Author keywords

Intracardiac ultrasound; Orientation; Radiofrequency ablation; Ventricle; Ventricular tachycardia

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CATHETER ABLATION; DOG; ECHOCARDIOGRAPHY; FEMALE; FLUOROSCOPY; HEART CATHETERIZATION; HEART LEFT VENTRICLE; MALE; NONHUMAN; RADIOFREQUENCY; STATISTICAL ANALYSIS;

EID: 0033063965     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb00469.x     Document Type: Article
Times cited : (43)

References (15)
  • 1
    • 0024364286 scopus 로고
    • Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
    • 1. Haines DE, Watson DD. Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. PACE 1989; 12:962-976.
    • (1989) PACE , vol.12 , pp. 962-976
    • Haines, D.E.1    Watson, D.D.2
  • 2
    • 0025293526 scopus 로고
    • Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
    • 2. Haines DE, Watson DD, Verow AF. Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. Circ Res 1990; 67:124-129.
    • (1990) Circ Res , vol.67 , pp. 124-129
    • Haines, D.E.1    Watson, D.D.2    Verow, A.F.3
  • 3
    • 0024363035 scopus 로고
    • The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro
    • 3. Blouin LT, Marcus FI. The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro. PACE 1989; 12(Pt. II):136-143.
    • (1989) PACE , vol.12 , Issue.PT. II , pp. 136-143
    • Blouin, L.T.1    Marcus, F.I.2
  • 4
    • 0027295050 scopus 로고
    • Temperature-guided radiofrequency catheter ablation with very large distal electrodes
    • 4. Langberg JJ, Gallagher M, Strickberger SA, et al. Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993; 88:245-249.
    • (1993) Circulation , vol.88 , pp. 245-249
    • Langberg, J.J.1    Gallagher, M.2    Strickberger, S.A.3
  • 5
    • 0028355690 scopus 로고
    • Advanced radiofrequency catheter ablation in canine myocardium
    • 5. Rosenbaum R, Greenspon AJ, Smith M, et al. Advanced radiofrequency catheter ablation in canine myocardium. Am Heart J 1994; 127:851-857.
    • (1994) Am Heart J , vol.127 , pp. 851-857
    • Rosenbaum, R.1    Greenspon, A.J.2    Smith, M.3
  • 6
    • 0024511761 scopus 로고
    • Electrocardiographic localization of the site of origin of ventricular tachycardia in patients with prior myocardial infarction
    • 6. Kuchar DL, Ruskin JN, Garan H. Electrocardiographic localization of the site of origin of ventricular tachycardia in patients with prior myocardial infarction. J Am Coll Cardiol 1989; 13:893-903.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 893-903
    • Kuchar, D.L.1    Ruskin, J.N.2    Garan, H.3
  • 7
    • 0024805617 scopus 로고
    • Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature
    • 7. Hindricks G, Haverkamp W, Gulker H, et al. Radiofrequency coagulation of ventricular myocardium: Improved prediction of lesion size by monitoring catheter tip temperature. Eur Heart J 1989; 10:972-984.
    • (1989) Eur Heart J , vol.10 , pp. 972-984
    • Hindricks, G.1    Haverkamp, W.2    Gulker, H.3
  • 8
    • 0025095887 scopus 로고
    • Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
    • 8. Langberg JJ, Lee MA, Chin MC, et al. Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo [see comments]. PACE 1990; 13:1242-1248.
    • (1990) PACE , vol.13 , pp. 1242-1248
    • Langberg, J.J.1    Lee, M.A.2    Chin, M.C.3
  • 9
    • 0022875997 scopus 로고
    • Factors influencing transcatheter radiofrequency ablation of the myocardium
    • 9. Hoyt RH, Huang SKS, Marcus FL, et al. Factors influencing transcatheter radiofrequency ablation of the myocardium. J Appl Cardiol 1986; 1:469-486.
    • (1986) J Appl Cardiol , vol.1 , pp. 469-486
    • Hoyt, R.H.1    Huang, S.K.S.2    Marcus, F.L.3
  • 10
    • 15444359497 scopus 로고    scopus 로고
    • Why a large tip electrode makes a deeper radiofrequency lesion - Effects of increase in electrode cooling and electrode-tissue interface area
    • 10. Otomo K, Yamanashi WS, Tondo C, et al. Why a large tip electrode makes a deeper radiofrequency lesion - effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophysio 1998; 9:47-54.
    • (1998) J Cardiovasc Electrophysio , vol.9 , pp. 47-54
    • Otomo, K.1    Yamanashi, W.S.2    Tondo, C.3
  • 11
    • 0000988310 scopus 로고    scopus 로고
    • Voltage and duration dependence of radiofrequency lesion generation in the canine ventricle with an irrigation tip catheter
    • 11. Packer D, Johnson S. Voltage and duration dependence of radiofrequency lesion generation in the canine ventricle with an irrigation tip catheter. (Abstract) PACE 1996; 19:710.
    • (1996) PACE , vol.19 , pp. 710
    • Packer, D.1    Johnson, S.2
  • 12
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • 12. Nakagawa H, Yamanashi WS, Pitha JV, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 13
    • 0028227764 scopus 로고
    • Late enlargement of radiofrequency lesions in infant lambs. Implications for ablation procedures in small children
    • 13. Saul JP, Hulse JE, Papagiannis J, et al. Late enlargement of radiofrequency lesions in infant lambs. Implications for ablation procedures in small children [see comments]. Circulation 1994; 90:492-499.
    • (1994) Circulation , vol.90 , pp. 492-499
    • Saul, J.P.1    Hulse, J.E.2    Papagiannis, J.3
  • 14
    • 0023745244 scopus 로고
    • Radiofrequency current directed across the mitral anulus with a bipolar epicardial-endocardial catheter electrode configuration in dogs
    • 14. Jackman WM, Kuck KH, Naccarelli GV, et al. Radiofrequency current directed across the mitral anulus with a bipolar epicardial-endocardial catheter electrode configuration in dogs. Circulation 1988; 78:1288-1298.
    • (1988) Circulation , vol.78 , pp. 1288-1298
    • Jackman, W.M.1    Kuck, K.H.2    Naccarelli, G.V.3
  • 15
    • 0028859230 scopus 로고
    • Catheter ablation of ventricular tachycardia
    • 15. Daoud E, Morady F. Catheter ablation of ventricular tachycardia. [Review] [19 refs]. Curr Opin Cardiol 1995; 10:21-25.
    • (1995) Curr Opin Cardiol , vol.10 , pp. 21-25
    • Daoud, E.1    Morady, F.2