Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery
-
1. Haines DE. Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol 1991; 2:509-515.
-
(1991)
J Cardiovasc Electrophysiol
, vol.2
, pp. 509-515
-
-
Haines, D.E.1
-
2
-
-
0032483049
-
Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling
-
2. Nakagawa H, Wittkampf FH, Yamanashi WS, et al. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. Circulation 1998; 98: 458-465.
-
(1998)
Circulation
, vol.98
, pp. 458-465
-
-
Nakagawa, H.1
Wittkampf, F.H.2
Yamanashi, W.S.3
-
3
-
-
0032977933
-
Temperature response following nontraumatic low power radiofrequency application
-
3. Schumacher B, Eick O, Wittkampf F, et al. Temperature response following nontraumatic low power radiofrequency application. PACE 1999; 22:339-343.
-
(1999)
PACE
, vol.22
, pp. 339-343
-
-
Schumacher, B.1
Eick, O.2
Wittkampf, F.3
-
4
-
-
0031770673
-
The LETR-principle: A novel method to assess electrode-tissue contact in radiofrequency ablation
-
4. Eick OJ, Wittkampf FH, Bronneberg T, et al. The LETR-Principle: A novel method to assess electrode-tissue contact in radiofrequency ablation. J Cardiovasc Electrophysiol 1998; 9:1180-1185.
-
(1998)
J Cardiovasc Electrophysiol
, vol.9
, pp. 1180-1185
-
-
Eick, O.J.1
Wittkampf, F.H.2
Bronneberg, T.3
-
5
-
-
0024991053
-
Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium
-
5. Haines DE, Verow AF. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Circulation 1990; 82: 1034-1038.
-
(1990)
Circulation
, vol.82
, pp. 1034-1038
-
-
Haines, D.E.1
Verow, A.F.2
-
6
-
-
0003331682
-
Intracardiac explosions during radiofrequency ablation: Histopathology in the acute and chronic dog model
-
6. Avitall B, Morgan M, Hare J, et al. Intracardiac explosions during radiofrequency ablation: Histopathology in the acute and chronic dog model. (Abstract) Circulation 1992; 86.
-
(1992)
Circulation
, vol.86
-
-
Avitall, B.1
Morgan, M.2
Hare, J.3
-
7
-
-
0032903237
-
Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium
-
7. Petersen HH, Chen X, Pietersen A, et al. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium. Circulation 1999; 99:319-325.
-
(1999)
Circulation
, vol.99
, pp. 319-325
-
-
Petersen, H.H.1
Chen, X.2
Pietersen, A.3
-
8
-
-
0031436188
-
The effects of electrode-tissue contact on radiofrequency lesion generation
-
8. Avitall B, Mughal K, Hare J, et al. The effects of electrode-tissue contact on radiofrequency lesion generation. PACE 1997; 20:2899-2910.
-
(1997)
PACE
, vol.20
, pp. 2899-2910
-
-
Avitall, B.1
Mughal, K.2
Hare, J.3
-
9
-
-
0026560571
-
Importance of physical parameters for the effectiveness of radiofrequency catheter ablation
-
Berl
-
9. Hoffmann E, Dorwarth U, Pulter R, et al. [Importance of physical parameters for the effectiveness of radiofrequency catheter ablation]. Biomed Tech (Berl) 1992; 37:62-68.
-
(1992)
Biomed Tech
, vol.37
, pp. 62-68
-
-
Hoffmann, E.1
Dorwarth, U.2
Pulter, R.3
-
10
-
-
0026458157
-
Biophysical parameters of radiofrequency catheter ablation
-
10. Hoffmann E, Haberl R, Pulter R, et al. Biophysical parameters of radiofrequency catheter ablation. Int J Cardiol 1992; 37:213-222.
-
(1992)
Int J Cardiol
, vol.37
, pp. 213-222
-
-
Hoffmann, E.1
Haberl, R.2
Pulter, R.3
-
11
-
-
0031933716
-
Radiofrequency current ablation of porcine right atrium: Increased lesion size with bipolar two catheter technique compared to unipolar application in vitro and in vivo
-
11. Anfinsen OG, Kongsgaard E, Foerster A, et al. Radiofrequency current ablation of porcine right atrium: Increased lesion size with bipolar two catheter technique compared to unipolar application in vitro and in vivo. PACE 1998; 21:69-78.
-
(1998)
PACE
, vol.21
, pp. 69-78
-
-
Anfinsen, O.G.1
Kongsgaard, E.2
Foerster, A.3
-
12
-
-
0029054772
-
Effects of combined radiofrequency and direct current energy catheter ablation on ventricular myocardium in pigs
-
12. Kongsgaard E, Foerster A, Aass H, et al. Effects of combined radiofrequency and direct current energy catheter ablation on ventricular myocardium in pigs. Eur Heart J 1995;16:514-520.
-
(1995)
Eur Heart J
, vol.16
, pp. 514-520
-
-
Kongsgaard, E.1
Foerster, A.2
Aass, H.3
|