메뉴 건너뛰기




Volumn 26, Issue 3, 2003, Pages 725-730

Tissue temperature-controlled radiofrequency ablation

Author keywords

Catheter ablation; Electrode contact; Flow; Radiofrequency; Tissue temperature

Indexed keywords

ISOTONIC SOLUTION; SODIUM CHLORIDE;

EID: 0037357279     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.00123.x     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 0026325244 scopus 로고
    • Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery
    • Haines DE. Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol 1991; 2:509-515.
    • (1991) J Cardiovasc Electrophysiol , vol.2 , pp. 509-515
    • Haines, D.E.1
  • 2
    • 0031770673 scopus 로고    scopus 로고
    • The LETR-Principle: A novel method to assess electrode-tissue contact in radiofrequency ablation
    • Eick OJ, Wittkampf FH, Bronneberg T, et al. The LETR-Principle: A novel method to assess electrode-tissue contact in radiofrequency ablation. J Cardiovasc Electrophysiol 1998; 9:1180-1185.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1180-1185
    • Eick, O.J.1    Wittkampf, F.H.2    Bronneberg, T.3
  • 3
    • 0032483049 scopus 로고    scopus 로고
    • Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling
    • Nakagawa H, Wittkampf FH, Yamanashi WS, et al. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. Circulation 1998; 98:458-465.
    • (1998) Circulation , vol.98 , pp. 458-465
    • Nakagawa, H.1    Wittkampf, F.H.2    Yamanashi, W.S.3
  • 4
    • 0030953697 scopus 로고    scopus 로고
    • Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro
    • Kongsgaard E, Steen T, Jensen O, et al. Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro. PACE 1997; 20:1252-1260.
    • (1997) PACE , vol.20 , pp. 1252-1260
    • Kongsgaard, E.1    Steen, T.2    Jensen, O.3
  • 5
    • 0024991053 scopus 로고
    • Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium
    • Haines DE, Verow AF. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Circulation 1990; 82:1034-1038.
    • (1990) Circulation , vol.82 , pp. 1034-1038
    • Haines, D.E.1    Verow, A.F.2
  • 6
    • 0033956518 scopus 로고    scopus 로고
    • Popping phenomena in temperature controlled radiofrequency ablation: When and why do they occur?
    • Eick OJ, Gerritse B, Schumacher B. Popping phenomena in temperature controlled radiofrequency ablation: When and why do they occur? PACE 2000; 23:253-258.
    • (2000) PACE , vol.23 , pp. 253-258
    • Eick, O.J.1    Gerritse, B.2    Schumacher, B.3
  • 7
    • 0031930039 scopus 로고    scopus 로고
    • Lesion size in relation to ablation site during radiofrequency ablation
    • Petersen HH, Chen X, Pietersen A, et al. Lesion size in relation to ablation site during radiofrequency ablation. PACE 1998; 21:322-326.
    • (1998) PACE , vol.21 , pp. 322-326
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 8
    • 0031436188 scopus 로고    scopus 로고
    • The effects of electrode-tissue contact on radiofrequency lesion generation
    • Avitall B, Mughal K, Hare J, et al. The effects of electrode-tissue contact on radiofrequency lesion generation. PACE 1997; 20:2899-2910.
    • (1997) PACE , vol.20 , pp. 2899-2910
    • Avitall, B.1    Mughal, K.2    Hare, J.3
  • 9
    • 0031793610 scopus 로고    scopus 로고
    • Comparison of standard and irrigated radiofrequency ablation in the canine ventricle
    • Skrumeda LL, Mehra R. Comparison of standard and irrigated radiofrequency ablation in the canine ventricle. J Cardiovasc Electrophysiol 1998; 9:1196-1205.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1196-1205
    • Skrumeda, L.L.1    Mehra, R.2
  • 10
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation
    • Petersen HH, Chen X, Pietersen A, et al. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation. PACE 2000; 23:8-17.
    • (2000) PACE , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 11
    • 0027295050 scopus 로고
    • Temperature-guided radiofrequency catheter ablation with very large distal electrodes
    • Langberg JJ, Gallagher M, Strickberger SA, et al. Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993; 88:245-249.
    • (1993) Circulation , vol.88 , pp. 245-249
    • Langberg, J.J.1    Gallagher, M.2    Strickberger, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.