-
1
-
-
0034865723
-
Myocardial contrast echocardiography: Basic principles
-
Kaul S. Myocardial contrast echocardiography: basic principles. Prog. Cardiovasc. Dis. 44(1):2001;1-11
-
(2001)
Prog. Cardiovasc. Dis.
, vol.44
, Issue.1
, pp. 1-11
-
-
Kaul, S.1
-
2
-
-
0032855188
-
Imaging of myocardial perfusion with SonoVue in patients with prior myocardial infarction
-
Lindner J.R., Wei K., Kaul S. Imaging of myocardial perfusion with SonoVue in patients with prior myocardial infarction. Echocardiography. 16(7 pt 2):1999;753-760
-
(1999)
Echocardiography
, vol.16
, Issue.7 PART 2
, pp. 753-760
-
-
Lindner, J.R.1
Wei, K.2
Kaul, S.3
-
3
-
-
0030274319
-
Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection
-
Skyba D.M., Camarano G., Goodman N.C., Price R.J., Skalak T.C., Kaul S. Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection. J. Am. Coll. Cardiol. 28(5):1996;1292-1300
-
(1996)
J. Am. Coll. Cardiol.
, vol.28
, Issue.5
, pp. 1292-1300
-
-
Skyba, D.M.1
Camarano, G.2
Goodman, N.C.3
Price, R.J.4
Skalak, T.C.5
Kaul, S.6
-
4
-
-
0034286309
-
Imaging techniques for the myocardial contrast echocardiography
-
Vannan M.A., Kuersten B. Imaging techniques for the myocardial contrast echocardiography. Eur. J. Echocardiog. 1(3):2000;224-226
-
(2000)
Eur. J. Echocardiog.
, vol.1
, Issue.3
, pp. 224-226
-
-
Vannan, M.A.1
Kuersten, B.2
-
5
-
-
0037117659
-
Noninvasive imaging of myocardial reperfusion injury using leukocyte-targeted contrast echocardiography
-
Christiansen J.P., Leong-Poi H., Klibanov A.L., Kaul S., Lindner J.R. Noninvasive imaging of myocardial reperfusion injury using leukocyte-targeted contrast echocardiography. Circulation. 105(15):2002;1764-1767
-
(2002)
Circulation
, vol.105
, Issue.15
, pp. 1764-1767
-
-
Christiansen, J.P.1
Leong-Poi, H.2
Klibanov, A.L.3
Kaul, S.4
Lindner, J.R.5
-
6
-
-
0034727704
-
Noninvasive ultrasound imaging of inflammation using microbubbles targeted to activated leukocytes
-
Lindner J.R., Song J., Klibanov A.L., Singbartl K., Ley K., Kaul S. Noninvasive ultrasound imaging of inflammation using microbubbles targeted to activated leukocytes. Circulation. 102(22):2000;2745-2750
-
(2000)
Circulation
, vol.102
, Issue.22
, pp. 2745-2750
-
-
Lindner, J.R.1
Song, J.2
Klibanov, A.L.3
Singbartl, K.4
Ley, K.5
Kaul, S.6
-
7
-
-
0035940372
-
Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin
-
Lindner J.R., Song J., Christiansen J.P., Klibanov A.L., Xu F., Ley K. Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin. Circulation. 104(17):2001;2107-2112
-
(2001)
Circulation
, vol.104
, Issue.17
, pp. 2107-2112
-
-
Lindner, J.R.1
Song, J.2
Christiansen, J.P.3
Klibanov, A.L.4
Xu, F.5
Ley, K.6
-
8
-
-
0032764702
-
Enhanced visualization of intravascular and left atrial appendage thrombus with the use of a thrombus-targeting ultrasonographic contrast agent (MRX-408A1): In vivo experimental echocardiographic studies
-
Takeuchi M., Ogunyankin K., Panian N.G., McCreery T.P., Sweitzer R.H., Caldwell V.E., Unger E.C., Avelar E., Sheahan M., Connolly R. Enhanced visualization of intravascular and left atrial appendage thrombus with the use of a thrombus-targeting ultrasonographic contrast agent (MRX-408A1): in vivo experimental echocardiographic studies. J. Am. Soc. Echocardiogr. 12(12):1999;1015-1021
-
(1999)
J. Am. Soc. Echocardiogr.
, vol.12
, Issue.12
, pp. 1015-1021
-
-
Takeuchi, M.1
Ogunyankin, K.2
Panian, N.G.3
McCreery, T.P.4
Sweitzer, R.H.5
Caldwell, V.E.6
Unger, E.C.7
Avelar, E.8
Sheahan, M.9
Connolly, R.10
-
9
-
-
0032470386
-
Acoustically active lipospheres containing paclitaxel: A new therapeutic ultrasound contrast agent
-
Unger E.C., McCreery T.P., Sweitzer R.H., Caldwell V.E., Wu Y. Acoustically active lipospheres containing paclitaxel: a new therapeutic ultrasound contrast agent. Invest. Radiol. 33(12):1998;886-892
-
(1998)
Invest. Radiol.
, vol.33
, Issue.12
, pp. 886-892
-
-
Unger, E.C.1
McCreery, T.P.2
Sweitzer, R.H.3
Caldwell, V.E.4
Wu, Y.5
-
10
-
-
0041857832
-
Ultrasound-targeted microbubble destruction can repeatedly direct highly specific plasmid expression to the heart
-
Bekeredjian R., Chen S., Frenkel P.A., Grayburn P.A., Shohet R.V. Ultrasound-targeted microbubble destruction can repeatedly direct highly specific plasmid expression to the heart. Circulation. 108(8):2003;1022-1026
-
(2003)
Circulation
, vol.108
, Issue.8
, pp. 1022-1026
-
-
Bekeredjian, R.1
Chen, S.2
Frenkel, P.A.3
Grayburn, P.A.4
Shohet, R.V.5
-
11
-
-
0038826285
-
Optimization of ultrasound parameters for cardiac gene delivery of adenoviral or plasmid deoxyribonucleic acid by ultrasound-targeted microbubble destruction
-
Chen S., Shohet R.V., Bekeredjian R., Frenkel P., Grayburn P.A. Optimization of ultrasound parameters for cardiac gene delivery of adenoviral or plasmid deoxyribonucleic acid by ultrasound-targeted microbubble destruction. J. Am. Coll. Cardiol. 42(2):2003;301-308
-
(2003)
J. Am. Coll. Cardiol.
, vol.42
, Issue.2
, pp. 301-308
-
-
Chen, S.1
Shohet, R.V.2
Bekeredjian, R.3
Frenkel, P.4
Grayburn, P.A.5
-
12
-
-
0032493267
-
Microbubbles targeted to intercellular adhesion molecule-1 bind to activated coronary artery endothelial cells
-
Villanueva F.S., Jankowski R.J., Klibanov S., Pina M.L., Alber S.M., Watkins S.C., Brandenburger G.H., Wagner W.R. Microbubbles targeted to intercellular adhesion molecule-1 bind to activated coronary artery endothelial cells. Circulation. 98(1):1998;1-5
-
(1998)
Circulation
, vol.98
, Issue.1
, pp. 1-5
-
-
Villanueva, F.S.1
Jankowski, R.J.2
Klibanov, S.3
Pina, M.L.4
Alber, S.M.5
Watkins, S.C.6
Brandenburger, G.H.7
Wagner, W.R.8
-
13
-
-
0032836212
-
Targeting and ultrasound imaging of microbubble-based contrast agents
-
Klibanov A.L., Hughes M.S., Villanueva F.S., Jankowski R.J., Wagner W.R., Wojdyla J.K., Wible J.H., Brandenburger G.H. Targeting and ultrasound imaging of microbubble-based contrast agents. Magn. Res. Mater. Phys., Biol. Med. 8(3):1999;177-184
-
(1999)
Magn. Res. Mater. Phys., Biol. Med.
, vol.8
, Issue.3
, pp. 177-184
-
-
Klibanov, A.L.1
Hughes, M.S.2
Villanueva, F.S.3
Jankowski, R.J.4
Wagner, W.R.5
Wojdyla, J.K.6
Wible, J.H.7
Brandenburger, G.H.8
-
14
-
-
1842869919
-
Modulating targeted adhesion of an ultrasound contrast agent to dysfunctional endothelium
-
Weller G.E., Villanueva F.S., Klibanov A.L., Wagner W.R. Modulating targeted adhesion of an ultrasound contrast agent to dysfunctional endothelium. Ann. Biomed. Eng. 30(8):2002;1012-1019
-
(2002)
Ann. Biomed. Eng.
, vol.30
, Issue.8
, pp. 1012-1019
-
-
Weller, G.E.1
Villanueva, F.S.2
Klibanov, A.L.3
Wagner, W.R.4
-
15
-
-
0028834456
-
Neutrophils use both shared and distinct mechanisms to adhere to selectins under static and flow conditions
-
Patel K.D., Moore K.L., Nollert M.U., McEver R.P. Neutrophils use both shared and distinct mechanisms to adhere to selectins under static and flow conditions. J. Clin. Invest. 96(4):1995;1887-1896
-
(1995)
J. Clin. Invest.
, vol.96
, Issue.4
, pp. 1887-1896
-
-
Patel, K.D.1
Moore, K.L.2
Nollert, M.U.3
McEver, R.P.4
-
17
-
-
0030890791
-
Isolated P-selectin glycoprotein ligand-1 dynamic adhesion to P- and E-selectin
-
Goetz D.J., Greif D.M., Ding H., Camphausen R.T., Howes S., Comess K.M., Snapp K.R., Kansas G.S., Luscinskas F.W. Isolated P-selectin glycoprotein ligand-1 dynamic adhesion to P- and E-selectin. J. Cell Biol. 137(2):1997;509-519
-
(1997)
J. Cell Biol.
, vol.137
, Issue.2
, pp. 509-519
-
-
Goetz, D.J.1
Greif, D.M.2
Ding, H.3
Camphausen, R.T.4
Howes, S.5
Comess, K.M.6
Snapp, K.R.7
Kansas, G.S.8
Luscinskas, F.W.9
-
18
-
-
0034743316
-
Ligand coated nanosphere adhesion to E- and P-selectin under static and flow conditions
-
Blackwell J.E., Dagia N.M., Dickerson J.B., Berg E.L., Goetz D.J. Ligand coated nanosphere adhesion to E- and P-selectin under static and flow conditions. Ann. Biomed. Eng. 29(6):2001;523-533
-
(2001)
Ann. Biomed. Eng.
, vol.29
, Issue.6
, pp. 523-533
-
-
Blackwell, J.E.1
Dagia, N.M.2
Dickerson, J.B.3
Berg, E.L.4
Goetz, D.J.5
-
19
-
-
0028605282
-
Only simultaneous blocking of the L- and P-selectin completely inhibits neutrophil migration into mouse peritoneum
-
Bosse R., Vestweber D. Only simultaneous blocking of the L- and P-selectin completely inhibits neutrophil migration into mouse peritoneum. Eur. J. Immunol. 24(12):1994;3019-3024
-
(1994)
Eur. J. Immunol.
, vol.24
, Issue.12
, pp. 3019-3024
-
-
Bosse, R.1
Vestweber, D.2
-
21
-
-
78651196598
-
A spectrophotometric assay for avidin and biotin based on binding of dyes by avidin
-
Green N.M. A spectrophotometric assay for avidin and biotin based on binding of dyes by avidin. Biochem. J. 94:1965;23c-24c
-
(1965)
Biochem. J.
, vol.94
-
-
Green, N.M.1
-
22
-
-
0026611812
-
Eu-labeled streptavidin as a universal label. Indirect time-resolved immunofluorometry of FSH and LH
-
Suonpaa M., Markella E., Stahlberg T., Hemmila I. Eu-labeled streptavidin as a universal label. Indirect time-resolved immunofluorometry of FSH and LH. J. Immunol. Methods. 149(2):1992;247-253
-
(1992)
J. Immunol. Methods
, vol.149
, Issue.2
, pp. 247-253
-
-
Suonpaa, M.1
Markella, E.2
Stahlberg, T.3
Hemmila, I.4
-
23
-
-
0032758446
-
Attachment of ligands to gas-filled microbubbles via PEG spacer and lipid residues anchored at the interface
-
Boston, MA: Controlled Release Society
-
Klibanov A.L., Gu H., Wojdyla J.K., Wible J.H., Kim D.H., Needham D., Villanueva F.S., Brandenburger G.H. Attachment of ligands to gas-filled microbubbles via PEG spacer and lipid residues anchored at the interface. Proceedings of the 26th International Symposium on Controlled Release of Bioactive Materials. 1999;124-125 Controlled Release Society, Boston, MA
-
(1999)
Proceedings of the 26th International Symposium on Controlled Release of Bioactive Materials
, pp. 124-125
-
-
Klibanov, A.L.1
Gu, H.2
Wojdyla, J.K.3
Wible, J.H.4
Kim, D.H.5
Needham, D.6
Villanueva, F.S.7
Brandenburger, G.H.8
-
24
-
-
0025854524
-
Leukocytes roll a selectin at physiologic flow rates: Distinction from and prerequisite for adhesion through integrins
-
Lawrence M.B., Springer T.A. Leukocytes roll a selectin at physiologic flow rates: distinction from and prerequisite for adhesion through integrins. Cell. 65(5):1991;859-873
-
(1991)
Cell
, vol.65
, Issue.5
, pp. 859-873
-
-
Lawrence, M.B.1
Springer, T.A.2
-
25
-
-
0033618074
-
Versatile functionalization of polylysine: Synthesis, characterization, and use of neoglycoconjugates
-
Thoma G., Patton J.T., Magnani J.L., Ernst B., Ohrlein R., Duthaler R.O. Versatile functionalization of polylysine: synthesis, characterization, and use of neoglycoconjugates. J. Am. Chem. Soc. 121(25):1999;5919-5929
-
(1999)
J. Am. Chem. Soc.
, vol.121
, Issue.25
, pp. 5919-5929
-
-
Thoma, G.1
Patton, J.T.2
Magnani, J.L.3
Ernst, B.4
Ohrlein, R.5
Duthaler, R.O.6
-
26
-
-
0031458014
-
Prevention of late renal changes after initial ischemia/reperfusion injury by blocking early selectin binding
-
Takada M., Nadeau K.C., Shaw G.D., Tilney N.L. Prevention of late renal changes after initial ischemia/reperfusion injury by blocking early selectin binding. Transplantation. 64(11):1997;1520-1525
-
(1997)
Transplantation
, vol.64
, Issue.11
, pp. 1520-1525
-
-
Takada, M.1
Nadeau, K.C.2
Shaw, G.D.3
Tilney, N.L.4
-
27
-
-
0027218496
-
Structural and functional characterization of monomeric soluble P-selectin and comparison with membrane P-selectin
-
Ushiyama S., Laue T.M., Moore K.L., Erickson H.P., McEver R.P. Structural and functional characterization of monomeric soluble P-selectin and comparison with membrane P-selectin. J. Biol. Chem. 268(20):1993;15229-15237
-
(1993)
J. Biol. Chem.
, vol.268
, Issue.20
, pp. 15229-15237
-
-
Ushiyama, S.1
Laue, T.M.2
Moore, K.L.3
Erickson, H.P.4
McEver, R.P.5
-
28
-
-
0027496605
-
Relationship between receptor/ligand binding affinity and adhesion strength
-
Kuo S.C., Lauffenburger D.A. Relationship between receptor/ligand binding affinity and adhesion strength. Biophys. J. 65(5):1993;2191-2200
-
(1993)
Biophys. J.
, vol.65
, Issue.5
, pp. 2191-2200
-
-
Kuo, S.C.1
Lauffenburger, D.A.2
-
29
-
-
0036212383
-
Comparison of PSGL-1 microbead and neutrophil rolling: Microvillus elongation stabilizes P-selectin bond clusters
-
Park E.Y., Smith M.J., Stropp E.S., Snapp K.R., DiVietro J.A., Walker W.F., Schmidtke D.W., Diamond S.L., Lawrence M.B. Comparison of PSGL-1 microbead and neutrophil rolling: microvillus elongation stabilizes P-selectin bond clusters. Biophys. J. 82(4):2002;1835-1847
-
(2002)
Biophys. J.
, vol.82
, Issue.4
, pp. 1835-1847
-
-
Park, E.Y.1
Smith, M.J.2
Stropp, E.S.3
Snapp, K.R.4
Divietro, J.A.5
Walker, W.F.6
Schmidtke, D.W.7
Diamond, S.L.8
Lawrence, M.B.9
-
30
-
-
0037653696
-
Direct observation of catch bonds involving cell-adhesion molecules
-
Marshall B.T., Long M., Piper J.W., Yago T., McEver R.P., Zhu C. Direct observation of catch bonds involving cell-adhesion molecules. Nature. 423(6936):2003;190-193
-
(2003)
Nature
, vol.423
, Issue.6936
, pp. 190-193
-
-
Marshall, B.T.1
Long, M.2
Piper, J.W.3
Yago, T.4
McEver, R.P.5
Zhu, C.6
-
31
-
-
0026014586
-
Endothelial, not hemodynamic, differences are responsible for preferential leukocyte rolling in rat mesenteric venules
-
Ley K., Gaehtgens P. Endothelial, not hemodynamic, differences are responsible for preferential leukocyte rolling in rat mesenteric venules. Circ. Res. 69(4):1991;1034-1041
-
(1991)
Circ. Res.
, vol.69
, Issue.4
, pp. 1034-1041
-
-
Ley, K.1
Gaehtgens, P.2
-
32
-
-
0029724374
-
Surface treatments of polymers for biocompatibility
-
Elbert D.L., Hubbell J.L. Surface treatments of polymers for biocompatibility. Annu. Rev. Mater. Sci. 26:1996;365-394
-
(1996)
Annu. Rev. Mater. Sci.
, vol.26
, pp. 365-394
-
-
Elbert, D.L.1
Hubbell, J.L.2
-
33
-
-
0023897592
-
Photon correlation spectroscopy of human IgG
-
Jossang T., Feder J., Rosenqvist E. Photon correlation spectroscopy of human IgG. J. Protein Chem. 7(2):1988;165-171
-
(1988)
J. Protein Chem.
, vol.7
, Issue.2
, pp. 165-171
-
-
Jossang, T.1
Feder, J.2
Rosenqvist, E.3
-
34
-
-
0024392826
-
The behavior of sonicated albumin microbubbles within the microcirculation: A basis for their use during myocardial contrast echocardiography
-
Keller M.W., Segal S.S., Kaul S., Duling B. The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography. Circ. Res. 65(2):1989;458-467
-
(1989)
Circ. Res.
, vol.65
, Issue.2
, pp. 458-467
-
-
Keller, M.W.1
Segal, S.S.2
Kaul, S.3
Duling, B.4
|