메뉴 건너뛰기




Volumn 8, Issue 4, 2003, Pages 410-420

Miniaturization of fluorescence polarization receptor-binding assays using CyDye-labeled ligands

Author keywords

CyDye labeled nonpeptide and peptide ligands; Fluorescence polarization; High throughput screening; Miniaturization of FP receptor assays

Indexed keywords

ATROPINE; BETA 2 ADRENERGIC RECEPTOR; DYE; LIGAND; REAGENT; RECEPTOR; SEROTONIN 3 RECEPTOR; SUBSTANCE P DERIVATIVE; TELENZEPINE; CARBOCYANINE; CELL SURFACE RECEPTOR; CYANINE DYE 3; DRUG DERIVATIVE; FLUORESCENT DYE; MUSCARINIC RECEPTOR; NEUROKININ 1 RECEPTOR; NEUROKININ A; PEPTIDE; PIRENZEPINE; SUBSTANCE P;

EID: 1842775922     PISSN: 10870571     EISSN: None     Source Type: Journal    
DOI: 10.1177/1087057103256319     Document Type: Article
Times cited : (38)

References (20)
  • 2
    • 0030826420 scopus 로고    scopus 로고
    • Characterization of non-peptide antagonist and peptide agonist binding sites of the NK1 receptor with fluorescent ligands
    • Turcatti G, Zoffmann S, Lowe JA, Drozda SE, Chassaing G, Schwartz TW, et al: Characterization of non-peptide antagonist and peptide agonist binding sites of the NK1 receptor with fluorescent ligands. J Biol Chem 1997;272(34):21167- 21175.
    • (1997) J Biol Chem , vol.272 , Issue.34 , pp. 21167-21175
    • Turcatti, G.1    Zoffmann, S.2    Lowe, J.A.3    Drozda, S.E.4    Chassaing, G.5    Schwartz, T.W.6
  • 3
    • 0008190079 scopus 로고    scopus 로고
    • Development of high throughput screening assays using fluorescence polarization: Nuclear receptor-ligand-binding and kinase/phosphatase assays
    • Parker GJ, Law TL, Lenoch FJ, Bolger RE: Development of high throughput screening assays using fluorescence polarization: nuclear receptor-ligand- binding and kinase/phosphatase assays. J Biomol Screen 2000;5(2):77-88.
    • (2000) J Biomol Screen , vol.5 , Issue.2 , pp. 77-88
    • Parker, G.J.1    Law, T.L.2    Lenoch, F.J.3    Bolger, R.E.4
  • 4
    • 0034054237 scopus 로고    scopus 로고
    • High throughput fluorescence polarization: A homogeneous alternative to radioligand binding for cell surface receptors
    • Allen M, Reeves J, Mellor G: High throughput fluorescence polarization: a homogeneous alternative to radioligand binding for cell surface receptors. J Biomol Screen 2000;5(2):63-69.
    • (2000) J Biomol Screen , vol.5 , Issue.2 , pp. 63-69
    • Allen, M.1    Reeves, J.2    Mellor, G.3
  • 5
    • 0033945739 scopus 로고    scopus 로고
    • Fluorescence polarization assays for high throughput screening of G protein-coupled receptors
    • Banks P, Gosselin M, Prystay L: Fluorescence polarization assays for high throughput screening of G protein-coupled receptors. J Biomol Screen 2000;5(3):159-167.
    • (2000) J Biomol Screen , vol.5 , Issue.3 , pp. 159-167
    • Banks, P.1    Gosselin, M.2    Prystay, L.3
  • 6
    • 0033778265 scopus 로고    scopus 로고
    • Impact of a red-shifted dye label for high throughput fluorescence polarization assays of G protein-coupled receptors
    • Banks P, Gosselin M, Prystay L: Impact of a red-shifted dye label for high throughput fluorescence polarization assays of G protein-coupled receptors. J Biomol Screen 2000;5(5):329-334.
    • (2000) J Biomol Screen , vol.5 , Issue.5 , pp. 329-334
    • Banks, P.1    Gosselin, M.2    Prystay, L.3
  • 7
    • 17044380767 scopus 로고    scopus 로고
    • Key to tables: Receptors
    • Key to tables: receptors. Trends Pharmacol Sci 1999;19(Suppl. 1):6-8.
    • (1999) Trends Pharmacol Sci , vol.19 , Issue.SUPPL. 1 , pp. 6-8
  • 8
    • 17044383943 scopus 로고    scopus 로고
    • Key to tables; receptors
    • Key to tables; receptors. Trends Pharmacol Sci 1999;19(Suppl. 1):78-79.
    • (1999) Trends Pharmacol Sci , vol.19 , Issue.SUPPL. 1 , pp. 78-79
  • 10
    • 0036448830 scopus 로고    scopus 로고
    • Neurobiology of substance P and the NK1 receptor
    • Mantyh PW: Neurobiology of substance P and the NK1 receptor. J Clin Psychiatry 2002;63(Suppl. 11):6-10.
    • (2002) J Clin Psychiatry , vol.63 , Issue.SUPPL. 11 , pp. 6-10
    • Mantyh, P.W.1
  • 12
    • 17044397897 scopus 로고    scopus 로고
    • Miniaturization of a homogeneous fluorescence polarization assay for M1 muscarinic acetylcholine receptors using CyDye labelled non-peptide ligands
    • Harris AJ, Cox SL, Norey CG, Burns DD: Miniaturization of a homogeneous fluorescence polarization assay for M1 muscarinic acetylcholine receptors using CyDye labelled non-peptide ligands. In Abstracts of Drug Discovery Technology, 2001.
    • (2001) Abstracts of Drug Discovery Technology
    • Harris, A.J.1    Cox, S.L.2    Norey, C.G.3    Burns, D.D.4
  • 14
    • 0026857961 scopus 로고
    • Molecular probes for muscarinic receptors: Derivatives of the M1-antagonist telenzepine
    • Karton Y, Baumgold J, Handen JS, Jacobson KA: Molecular probes for muscarinic receptors: derivatives of the M1-antagonist telenzepine. Bioconjugate Chem 1992;3:234-240.
    • (1992) Bioconjugate Chem , vol.3 , pp. 234-240
    • Karton, Y.1    Baumgold, J.2    Handen, J.S.3    Jacobson, K.A.4
  • 15
    • 0033003760 scopus 로고    scopus 로고
    • A simple statistical parameter for use in evaluation and validation of high throughput screening assays
    • Zhang J-H, Chung TDY, Oldenburg KR: A simple statistical parameter for use in evaluation and validation of high throughput screening assays. J Biomol Screen 1999;2:67-73.
    • (1999) J Biomol Screen , vol.2 , pp. 67-73
    • Zhang, J.-H.1    Chung, T.D.Y.2    Oldenburg, K.R.3
  • 17
    • 20644440200 scopus 로고    scopus 로고
    • Ligand binding to the seratonin 5HT receptor studied with a novel fluorescent ligand
    • Tairi AP, Hovius R, Pick H, Blasey H, Bernard A, Surprenant A, et al: Ligand binding to the seratonin 5HT receptor studied with a novel fluorescent ligand. Biochemistry 1998;37:15850-15864.
    • (1998) Biochemistry , vol.37 , pp. 15850-15864
    • Tairi, A.P.1    Hovius, R.2    Pick, H.3    Blasey, H.4    Bernard, A.5    Surprenant, A.6
  • 19
    • 0034752150 scopus 로고    scopus 로고
    • Real experiences of uHTS: A prototypic 1536-well fluorescence anisotropy-based uHTS screen and application of well-level quality control procedures
    • Turconi S, Shea K, Ashman S, Fantom K, Eamshaw DL, Bingham RP, et al: Real experiences of uHTS: a prototypic 1536-well fluorescence anisotropy-based uHTS screen and application of well-level quality control procedures. J Biomol Screen 2001;6(5):275-290.
    • (2001) J Biomol Screen , vol.6 , Issue.5 , pp. 275-290
    • Turconi, S.1    Shea, K.2    Ashman, S.3    Fantom, K.4    Eamshaw, D.L.5    Bingham, R.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.