메뉴 건너뛰기




Volumn 86, Issue 1, 2005, Pages 29-35

Understanding CAD in mammography;Comprendre et utiliser le CAD (aide informatisée au diagnostic) en mammographie

Author keywords

Breast cancer; Breast screening programs; CAD; Double reading; Mammography; Neural networks

Indexed keywords

BREAST CANCER; CANCER SCREENING; COMPUTER AIDED DETECTION; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; DIAGNOSTIC VALUE; IMAGE ANALYSIS; MAMMOGRAPHY; REVIEW; TECHNIQUE; VALIDATION PROCESS;

EID: 14744277152     PISSN: 02210363     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0221-0363(05)81319-8     Document Type: Review
Times cited : (10)

References (56)
  • 1
    • 0038798093 scopus 로고    scopus 로고
    • Cancer incidence and mortality in France over the period 1978-2000
    • Remontet L, Esteve J, Bouvier AM, et al. Cancer incidence and mortality in France over the period 1978-2000. Rev Epidemiol Sante Publique 2003;51:3-30.
    • (2003) Rev Epidemiol Sante Publique , vol.51 , pp. 3-30
    • Remontet, L.1    Esteve, J.2    Bouvier, A.M.3
  • 2
    • 0030280661 scopus 로고    scopus 로고
    • Effect of human variability on independent double reading in screening mammography
    • Beam CA, Sullivan DC, Layde PM. Effect of human variability on independent double reading in screening mammography. Acad Radiol 1996;3:891-97.
    • (1996) Acad Radiol , vol.3 , pp. 891-897
    • Beam, C.A.1    Sullivan, D.C.2    Layde, P.M.3
  • 4
    • 0026655955 scopus 로고
    • Analysis of cancers missed at screening mammography
    • Bird RE, Wallace TW, Yankaskas BC. Analysis of cancers missed at screening mammography. Radiology 1992;184:613-17.
    • (1992) Radiology , vol.184 , pp. 613-617
    • Bird, R.E.1    Wallace, T.W.2    Yankaskas, B.C.3
  • 5
    • 0031092288 scopus 로고    scopus 로고
    • Opinions about mammographic double reading
    • Hall FM. Opinions about mammographic double reading. AJR Am J Roentgenol 1997;168:846.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 846
    • Hall, F.M.1
  • 6
    • 0018838201 scopus 로고
    • Mammography training in diagnostic radiology residency programs
    • Homer MJ. Mammography training in diagnostic radiology residency programs. Radiology 1980;135:529-31.
    • (1980) Radiology , vol.135 , pp. 529-531
    • Homer, M.J.1
  • 8
    • 0034025882 scopus 로고    scopus 로고
    • Improving the detection of cancer in the screening of mammograms
    • Laming D, Warren R. Improving the detection of cancer in the screening of mammograms. J Med Screen 2000;7:24-30.
    • (2000) J Med Screen , vol.7 , pp. 24-30
    • Laming, D.1    Warren, R.2
  • 10
    • 0029442326 scopus 로고
    • Independent double reading of screening mammograms
    • Ciatto S, Del Turco MR, Morrone D, et al. Independent double reading of screening mammograms. J Med Screen 1995;2:99-101.
    • (1995) J Med Screen , vol.2 , pp. 99-101
    • Ciatto, S.1    Del Turco, M.R.2    Morrone, D.3
  • 11
    • 0028230453 scopus 로고
    • Benefit of independent double reading in a population-based mammography screening program
    • Thurfjell EL, Lernevall KA, Taube AA. Benefit of independent double reading in a population-based mammography screening program. Radiology 1994;191:241-44.
    • (1994) Radiology , vol.191 , pp. 241-244
    • Thurfjell, E.L.1    Lernevall, K.A.2    Taube, A.A.3
  • 13
    • 0033277542 scopus 로고    scopus 로고
    • How experience and training influence mammography expertise
    • Nodine CF, Kundel HL, Mello-Thoms C, et al. How experience and training influence mammography expertise. Acad Radiol 1999;6:575-85.
    • (1999) Acad Radiol , vol.6 , pp. 575-585
    • Nodine, C.F.1    Kundel, H.L.2    Mello-Thoms, C.3
  • 15
    • 0027600022 scopus 로고
    • An "intelligent" workstation for computer-aided diagnosis
    • Giger ML, Doi K, MacMahon H, et al. An "intelligent" workstation for computer-aided diagnosis. Radiographics 1993; 13:647-56.
    • (1993) Radiographics , vol.13 , pp. 647-656
    • Giger, M.L.1    Doi, K.2    MacMahon, H.3
  • 17
    • 0037654653 scopus 로고    scopus 로고
    • Breast cancer screening: Potential role of computer-aided detection (CAD)
    • Feig SA. Breast cancer screening: potential role of computer-aided detection (CAD). Technol Cancer Res Treat 2002;1:127-31.
    • (2002) Technol Cancer Res Treat , vol.1 , pp. 127-131
    • Feig, S.A.1
  • 18
    • 0034860859 scopus 로고    scopus 로고
    • Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    • Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology 2001;220:781-86.
    • (2001) Radiology , vol.220 , pp. 781-786
    • Freer, T.W.1    Ulissey, M.J.2
  • 19
    • 0032808791 scopus 로고    scopus 로고
    • The promise of computer aided detection in digital mammography
    • Roehrig J, Castellino RA. The promise of computer aided detection in digital mammography. Eur J Radiol 1999;31:35-9.
    • (1999) Eur J Radiol , vol.31 , pp. 35-39
    • Roehrig, J.1    Castellino, R.A.2
  • 20
    • 0038148322 scopus 로고    scopus 로고
    • Le CAD en mammographie: Un futur à évaluer
    • Boyer B, Troufleau P, Henrot P, Gaucher F, J S. Le CAD en mammographie: un futur à évaluer. Le Sein 2003;13:227-33.
    • (2003) Le Sein , vol.13 , pp. 227-233
    • Boyer, B.1    Troufleau, P.2    Henrot, P.3    Gaucher, F.4
  • 21
    • 0031205275 scopus 로고    scopus 로고
    • Computer-assisted evaluation of mammography images. Initial clinical experiences
    • Sittek H, Herrmann K, Perlet C, Kunzer I, Kessler M, Reiser M. Computer-assisted evaluation of mammography images. Initial clinical experiences. Radiologe 1997;37:610-16.
    • (1997) Radiologe , vol.37 , pp. 610-616
    • Sittek, H.1    Herrmann, K.2    Perlet, C.3    Kunzer, I.4    Kessler, M.5    Reiser, M.6
  • 22
    • 0036885749 scopus 로고    scopus 로고
    • Computer-aided detection in direct digital full-field mammography: Initial results
    • Baum F, Fischer U, Obenauer S, Grabbe E. Computer-aided detection in direct digital full-field mammography: initial results. Eur Radiol 2002;12:3015-17.
    • (2002) Eur Radiol , vol.12 , pp. 3015-3017
    • Baum, F.1    Fischer, U.2    Obenauer, S.3    Grabbe, E.4
  • 23
    • 0033764801 scopus 로고    scopus 로고
    • Digital and computer-aided mammography
    • Bassett LW. Digital and Computer-Aided Mammography. Breast J 2000; 6:291-93.
    • (2000) Breast J , vol.6 , pp. 291-293
    • Bassett, L.W.1
  • 24
    • 0029894991 scopus 로고    scopus 로고
    • Image processing and computer-aided diagnosis
    • Giger M, MacMahon H. Image processing and computer-aided diagnosis. Radiol Clin North Am 1996;34:565-96.
    • (1996) Radiol Clin North Am , vol.34 , pp. 565-596
    • Giger, M.1    MacMahon, H.2
  • 25
    • 0033624996 scopus 로고    scopus 로고
    • A CAD system for the automatic detection of clustered microcalcifications in digitized mammogram films
    • Yu S, Guan L. A CAD system for the automatic detection of clustered microcalcifications in digitized mammogram films. IEEE Trans Med Imaging 2000;19:115-26.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 115-126
    • Yu, S.1    Guan, L.2
  • 26
    • 0032872797 scopus 로고    scopus 로고
    • Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: An ROC study
    • Chan HP, Sahiner B, Helvie MA, et al. Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: an ROC study. Radiology 1999;212:817-27.
    • (1999) Radiology , vol.212 , pp. 817-827
    • Chan, H.P.1    Sahiner, B.2    Helvie, M.A.3
  • 27
    • 0034010317 scopus 로고    scopus 로고
    • Improved mammographic interpretation of masses using computer-aided diagnosis
    • Leichter I, Fields S, Nirel R, et al. Improved mammographic interpretation of masses using computer-aided diagnosis. Eur Radiol 2000;10:377-83.
    • (2000) Eur Radiol , vol.10 , pp. 377-383
    • Leichter, I.1    Fields, S.2    Nirel, R.3
  • 28
    • 0032089172 scopus 로고    scopus 로고
    • Computer-aided diagnosis in the detection of simulated clustered microcalcifications on mammography
    • Horino K. Computer-aided diagnosis in the detection of simulated clustered microcalcifications on mammography. Nippon Igaku Hoshasen Gakkai Zasshi 1998;58:343-48.
    • (1998) Nippon Igaku Hoshasen Gakkai Zasshi , vol.58 , pp. 343-348
    • Horino, K.1
  • 29
    • 0033400367 scopus 로고    scopus 로고
    • Lésions infra-cliniques: L'aide informatisée au diagnostic. Une réalité virtuelle?
    • Gilles R. Lésions infra-cliniques: l'aide informatisée au diagnostic. Une réalité virtuelle? Le Sein 2000;9:259-62.
    • (2000) Le Sein , vol.9 , pp. 259-262
    • Gilles, R.1
  • 30
    • 0027512684 scopus 로고
    • Artificial neural networks in mammography: Application to decision making in the diagnosis of breast cancer
    • Wu Y, Giger ML, Doi K, Vyborny CJ, Schmidt RA, Metz CE. Artificial neural networks in mammography: application to decision making in the diagnosis of breast cancer. Radiology 1993;187:81-7.
    • (1993) Radiology , vol.187 , pp. 81-87
    • Wu, Y.1    Giger, M.L.2    Doi, K.3    Vyborny, C.J.4    Schmidt, R.A.5    Metz, C.E.6
  • 31
    • 0032110235 scopus 로고    scopus 로고
    • Sensitivity and specificity of computer-assisted breast cancer detection in mammography screening
    • Thurfjell E, Thurfjell MG, Egge E, Bjurstam N. Sensitivity and specificity of computer-assisted breast cancer detection in mammography screening. Acta Radiol 1998;39:384-88.
    • (1998) Acta Radiol , vol.39 , pp. 384-388
    • Thurfjell, E.1    Thurfjell, M.G.2    Egge, E.3    Bjurstam, N.4
  • 32
    • 0031714538 scopus 로고    scopus 로고
    • Computer-assisted diagnosis in mammography: The R2 ImageChecker System in detection of spiculated lesions
    • Funovics M, Schamp S, Lackner B, Wunderbaldinger P, Lechner G, Wolf G. Computer-assisted diagnosis in mammography: the R2 ImageChecker System in detection of spiculated lesions. Wien Med Wochenschr 1998;148:321-24.
    • (1998) Wien Med Wochenschr , vol.148 , pp. 321-324
    • Funovics, M.1    Schamp, S.2    Lackner, B.3    Wunderbaldinger, P.4    Lechner, G.5    Wolf, G.6
  • 37
  • 38
    • 0029810535 scopus 로고    scopus 로고
    • Computer-aided detection of mammographie calcifications: Pattern recognition with an artificial neural network
    • Chan HP, Lo S.C., Sahiner B, Lam K.L, Helvie M.A. Computer-aided detection of mammographie calcifications: pattern recognition with an artificial neural network. Med Phys 1996;23:1325-36.
    • (1996) Med Phys , vol.23 , pp. 1325-1336
    • Chan, H.P.1    Lo, S.C.2    Sahiner, B.3    Lam, K.L.4    Helvie, M.A.5
  • 39
    • 0035248053 scopus 로고    scopus 로고
    • Radiologist detection of microcalcifications with and without computer-aided detection: A comparative study
    • Brem RF, Schoonjans JM. Radiologist detection of microcalcifications with and without computer-aided detection: a comparative study. Clin Radiol 2001;56:150-54.
    • (2001) Clin Radiol , vol.56 , pp. 150-154
    • Brem, R.F.1    Schoonjans, J.M.2
  • 41
    • 0030048533 scopus 로고    scopus 로고
    • Artificial neural network: Improving the quality of breast biopsy recommendations
    • Baker JA, Kornguth PJ, Lo JY, Floyd CE, Jr. Artificial neural network: improving the quality of breast biopsy recommendations. Radiology 1996;198:131-35.
    • (1996) Radiology , vol.198 , pp. 131-135
    • Baker, J.A.1    Kornguth, P.J.2    Lo, J.Y.3    Floyd Jr., C.E.4
  • 42
    • 0034120957 scopus 로고    scopus 로고
    • Quantitative characterization of mass lesions on digitized mammograms for computer-assisted diagnosis
    • Leichter I, Buchbinder S, Bamberger P, Novak B, Fields S, Lederman R. Quantitative characterization of mass lesions on digitized mammograms for computer-assisted diagnosis. Invest Radiol 2000;35:366-72.
    • (2000) Invest Radiol , vol.35 , pp. 366-372
    • Leichter, I.1    Buchbinder, S.2    Bamberger, P.3    Novak, B.4    Fields, S.5    Lederman, R.6
  • 43
    • 0042931349 scopus 로고    scopus 로고
    • Influence of breast lesion size and histologic findings on tumor detection rate of a computer-aided detection system
    • Malich A, Sauner D, Marx C, et al. Influence of breast lesion size and histologic findings on tumor detection rate of a computer-aided detection system. Radiology 2003;228:851-56.
    • (2003) Radiology , vol.228 , pp. 851-856
    • Malich, A.1    Sauner, D.2    Marx, C.3
  • 44
    • 0035195332 scopus 로고    scopus 로고
    • Tumour detection rate of a new commercially available computer-aided detection system
    • Malich A, Marx C, Facius M, Boehm T, Fleck M, Kaiser WA. Tumour detection rate of a new commercially available computer-aided detection system. Eur Radiol 2001;11:2454-59.
    • (2001) Eur Radiol , vol.11 , pp. 2454-2459
    • Malich, A.1    Marx, C.2    Facius, M.3    Boehm, T.4    Fleck, M.5    Kaiser, W.A.6
  • 45
    • 0036189717 scopus 로고    scopus 로고
    • Computer-aided diagnosis of masses with full-field digital mammography
    • Li L, Clark RA, Thomas JA. Computer-aided diagnosis of masses with full-field digital mammography. Acad Radiol 2002;9:4-12.
    • (2002) Acad Radiol , vol.9 , pp. 4-12
    • Li, L.1    Clark, R.A.2    Thomas, J.A.3
  • 46
    • 0036311184 scopus 로고    scopus 로고
    • Computer-aided diagnosis of breast tumors with different US systems
    • Kuo WJ, Chang RF, Moon WK, Lee CC, Chen DR. Computer-aided diagnosis of breast tumors with different US systems. Acad Radiol 2002;9:793-99.
    • (2002) Acad Radiol , vol.9 , pp. 793-799
    • Kuo, W.J.1    Chang, R.F.2    Moon, W.K.3    Lee, C.C.4    Chen, D.R.5
  • 47
    • 0036174154 scopus 로고    scopus 로고
    • Improvement of computerized mass detection on mammograms: Fusion of two-view information
    • Paquerault S, Petrick N, Chan HP, Sahiner B, Helvie MA. Improvement of computerized mass detection on mammograms: fusion of two-view information. Med Phys 2002;29:238-47.
    • (2002) Med Phys , vol.29 , pp. 238-247
    • Paquerault, S.1    Petrick, N.2    Chan, H.P.3    Sahiner, B.4    Helvie, M.A.5
  • 48
    • 0141520403 scopus 로고    scopus 로고
    • Computer-aided detection (CAD) in screening mammography: Sensitivity of commercial CAD systems for detecting architectural distortion
    • Baker JA, Rosen EL, Lo JY, Gimenez EI, Walsh R, Soo MS. Computer-aided detection (CAD) in screening mammography: sensitivity of commercial CAD systems for detecting architectural distortion. AJR Am J Roentgenol 2003;181:1083-88.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 1083-1088
    • Baker, J.A.1    Rosen, E.L.2    Lo, J.Y.3    Gimenez, E.I.4    Walsh, R.5    Soo, M.S.6
  • 49
    • 0035088227 scopus 로고    scopus 로고
    • Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection
    • Birdwell RL, Ikeda DM, O'Shaughnessy KF, Sickles EA. Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection. Radiology 2001;219:192-202.
    • (2001) Radiology , vol.219 , pp. 192-202
    • Birdwell, R.L.1    Ikeda, D.M.2    O'Shaughnessy, K.F.3    Sickles, E.A.4
  • 50
    • 0037322291 scopus 로고    scopus 로고
    • Clinical performance of computer-assisted detection CAD system in detecting carcinoma in breasts of different densities
    • Ho WT, Lam PW. Clinical performance of computer-assisted detection (CAD system in detecting carcinoma in breasts of different densities. Clin Radiol 2003;58:133-36.
    • (2003) Clin Radiol , vol.58 , pp. 133-136
    • Ho, W.T.1    Lam, P.W.2
  • 51
    • 0036917160 scopus 로고    scopus 로고
    • Contrast enhancement in dense breast images using the modulation transfer function
    • Nunes FL, Schiabel H, Benatti RH. Contrast enhancement in dense breast images using the modulation transfer function. Med Phys 2002;29:2925-36.
    • (2002) Med Phys , vol.29 , pp. 2925-2936
    • Nunes, F.L.1    Schiabel, H.2    Benatti, R.H.3
  • 52
    • 1342266123 scopus 로고    scopus 로고
    • Computer-aided detection output on 172 subtle findings on normal mammograms previously obtained in women with breast cancer detected at follow-up screening mammography
    • Ikeda DM, Birdwell RL, KF OS, Sickles EA, Brenner RJ. Computer-aided Detection Output on 172 Subtle Findings on Normal Mammograms Previously Obtained in Women with Breast Cancer Detected at Follow-Up Screening Mammography. Radiology 2004;230:811-9
    • (2004) Radiology , vol.230 , pp. 811-819
    • Ikeda, D.M.1    Birdwell, R.L.2    Sickles, E.A.3    Brenner, R.J.4
  • 53
    • 0037380362 scopus 로고    scopus 로고
    • Computer-aided detection versus independent double reading of masses on mammograms
    • Karssemeijer N, Otten JDM, Verbeek ALM, et al. Computer-aided Detection versus Independent Double Reading of Masses on Mammograms. Radiology 2003;227:192-200.
    • (2003) Radiology , vol.227 , pp. 192-200
    • Karssemeijer, N.1    Otten, J.D.M.2    Verbeek, A.L.M.3
  • 54
    • 0036986914 scopus 로고    scopus 로고
    • Utilisation d'un système d'aide à la détection par ordinateur dans un programme de dépistage. Analyse rétrospective des mammographies de 49 cancers
    • Lepori D, De Landtsheer JP, Piguet JC, De Geer G, Schnyder P, Y M. Utilisation d'un système d'aide à la détection par ordinateur dans un programme de dépistage. Analyse rétrospective des mammographies de 49 cancers. Le Sein 2002;12:295-303.
    • (2002) Le Sein , vol.12 , pp. 295-303
    • Lepori, D.1    De Landtsheer, J.P.2    Piguet, J.C.3    De Geer, G.4    Schnyder, P.5
  • 55
    • 0013059269 scopus 로고    scopus 로고
    • Apport d'un système d'aide à la détection assistée par ordinateur dans le cadre d'un programme de dépistage
    • Seradour B, Heid P, Pagliuchi C, et al. Apport d'un système d'aide à la détection assistée par ordinateur dans le cadre d'un programme de dépistage. Le Sein 2001;11:13-6.
    • (2001) Le Sein , vol.11 , pp. 13-16
    • Seradour, B.1    Heid, P.2    Pagliuchi, C.3
  • 56
    • 12144287924 scopus 로고    scopus 로고
    • Sensitivity of noncommercial computer-aided detection system for mammographic breast cancer detection: Pilot clinical trial
    • Helvie MA, Hadjiiski L, Makariou E, et al. Sensitivity of Noncommercial Computer-aided Detection System for Mammographic Breast Cancer Detection: Pilot Clinical Trial. Radiology 2004;231:208-14.
    • (2004) Radiology , vol.231 , pp. 208-214
    • Helvie, M.A.1    Hadjiiski, L.2    Makariou, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.