Volumn 29, Issue 8, 2002, Pages 1847-1858

IMRT verification by three-dimensional dose reconstruction from portal beam measurements

Author keywords

Electronic portal imaging; IMRT verification; Megavoltage CT

Indexed keywords

ITERATIVE METHODS; PHANTOMS;

EID: 0036703540     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1494988     Document Type: Article
Times cited : (83)

References (44)
  • 2
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • M. Essers and B. J. Heijmen, "In vivo dosimetry during external photon beam radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 43, 245-259 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , pp. 245-259
    • Essers, M.1    Heijmen, B.J.2
  • 5
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • C. Burman, C.-S. Chui, G. Kutcher, S. Leibel, M. Zelefsky, T. LoSasso, S. Spirou, Q. Wu, J. Yang, J. Stein, R. Mohan, Z. Fuks, and C. Ling, "Planning, delivery and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate," Int. J. Radiat. Oncol., Biol., Phys. 39, 863-873 (1997).
    • (1997) Int. J. Radiat. Oncol., Biol., Phys. , vol.39 , pp. 863-873
    • Burman, C.1    Chui, C.-S.2    Kutcher, G.3    Leibel, S.4    Zelefsky, M.5    LoSasso, T.6    Spirou, S.7    Wu, Q.8    Yang, J.9    Stein, J.10    Mohan, R.11    Fuks, Z.12    Ling, C.13
  • 7
    • 0031854569 scopus 로고    scopus 로고
    • Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation
    • K. L. Pasma, M. Kroonwijk, J. C. J. de Boer, A. G. Visser, and B. J. M. Heijmen, "Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation," Phys. Med. Biol. 43, 2047-2060 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2047-2060
    • Pasma, K.L.1    Kroonwijk, M.2    De Boer, J.C.J.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 8
    • 0033976918 scopus 로고    scopus 로고
    • Characterisation of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry
    • J. C. J. de Boer, B. J. M. Heijmen, K. L. Pasma, and A. G. Visser, "Characterisation of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry," Phys. Med. Biol. 45, 197-216 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 197-216
    • De Boer, J.C.J.1    Heijmen, B.J.M.2    Pasma, K.L.3    Visser, A.G.4
  • 9
    • 0029153633 scopus 로고
    • Portal dosimetry using a liquid ion chamber matrix: Dose response studies
    • Y. Zhu, X.-Q. Jiang, and J. Van Dyk, "Portal dosimetry using a liquid ion chamber matrix: Dose response studies," Med. Phys. 22, 1101-1106 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1101-1106
    • Zhu, Y.1    Jiang, X.-Q.2    Van Dyk, J.3
  • 10
    • 0031789184 scopus 로고    scopus 로고
    • The use of an electronic portal imager to measure portal dose and portal dose profiles
    • H. Parsaei, E. El-Khatib, and R. Rajapakshe, "The use of an electronic portal imager to measure portal dose and portal dose profiles," Med. Phys. 25, 1903-1909 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1903-1909
    • Parsaei, H.1    El-Khatib, E.2    Rajapakshe, R.3
  • 11
    • 0031732798 scopus 로고    scopus 로고
    • Calibration of a portal imaging device for high-precision dosimetry: A Monte Carlo study
    • H. Keller, M. Fix, and P. Rüegsegger, "Calibration of a portal imaging device for high-precision dosimetry: A Monte Carlo study," Med. Phys. 25, 1891-1902 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1891-1902
    • Keller, H.1    Fix, M.2    Rüegsegger, P.3
  • 12
    • 0030786466 scopus 로고    scopus 로고
    • Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model
    • R. Boellaard, M. van Herk, H. Uiterwaal, and B. Mijnheer, "Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model," Radiother. Oncol. 44, 149-157 (1997).
    • (1997) Radiother. Oncol. , vol.44 , pp. 149-157
    • Boellaard, R.1    Van Herk, M.2    Uiterwaal, H.3    Mijnheer, B.4
  • 14
    • 0034977377 scopus 로고    scopus 로고
    • Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    • B. C. McCurdy, K. Luchka, and S. Pistorius, "Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device," Med. Phys. 28, 911-924 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 911-924
    • McCurdy, B.C.1    Luchka, K.2    Pistorius, S.3
  • 15
    • 0030767978 scopus 로고    scopus 로고
    • Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system
    • L. Ma, P. B. Geis, and A. L. Boyer, "Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system," Med. Phys. 24, 1213-1220 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1213-1220
    • Ma, L.1    Geis, P.B.2    Boyer, A.L.3
  • 16
    • 0032717807 scopus 로고    scopus 로고
    • Dosimetric verification of intensity-modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    • K. L. Pasma, M. L. P. Dirkx, M. Kroonwijk, A. G. Visser, and B. J. M. Heijmen, "Dosimetric verification of intensity-modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device," Med. Phys. 26, 2373-2378 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2373-2378
    • Pasma, K.L.1    Dirkx, M.L.P.2    Kroonwijk, M.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 17
    • 0032934417 scopus 로고    scopus 로고
    • Verification of segmented beam delivery using a commercial electronic portal imaging device
    • A. J. Curtin-Savard and E. B. Podgorsak, "Verification of segmented beam delivery using a commercial electronic portal imaging device," Med. Phys. 26, 737-742 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 737-742
    • Curtin-Savard, A.J.1    Podgorsak, E.B.2
  • 18
    • 33744692928 scopus 로고    scopus 로고
    • Investigations on absolute portal dosimetry for the verification of static and dynamic dose delivery in radiotherapy
    • H. Keller, "Investigations on absolute portal dosimetry for the verification of static and dynamic dose delivery in radiotherapy," Med. Phys. 26, 2043 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2043
    • Keller, H.1
  • 19
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • M. Kirby and P. C. Williams, "The use of an electronic portal imaging device for exit dosimetry and quality control measurements," Int. J. Radiat. Oncol., Biol., Phys. 31, 593-603 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.31 , pp. 593-603
    • Kirby, M.1    Williams, P.C.2
  • 20
    • 0029790894 scopus 로고    scopus 로고
    • Modelling dose distributions from portal dose images using the convolution/superposition method
    • T. R. McNutt, T. R. Mackie, P. Reckwerdt, and B. R. Paliwal, "Modelling dose distributions from portal dose images using the convolution/superposition method," Med. Phys. 23. 1381-1392 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1381-1392
    • McNutt, T.R.1    Mackie, T.R.2    Reckwerdt, P.3    Paliwal, B.R.4
  • 22
    • 0031744989 scopus 로고    scopus 로고
    • First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose
    • R. Boellaard, M. van Herk, H. Uiterwaal, and B. Mijnheer, "First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose," Radiother. Oncol. 47, 303-312 (1998).
    • (1998) Radiother. Oncol. , vol.47 , pp. 303-312
    • Boellaard, R.1    Van Herk, M.2    Uiterwaal, H.3    Mijnheer, B.4
  • 24
    • 0032433905 scopus 로고    scopus 로고
    • In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion
    • M. Kroonwijk, K. L. Pasma, S. Quint, P. C. M. Koper, A. G. Visser, and B. J. M. Heijmen, "In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion," Radiother. Oncol. 49, 125-132 (1998).
    • (1998) Radiother. Oncol. , vol.49 , pp. 125-132
    • Kroonwijk, M.1    Pasma, K.L.2    Quint, S.3    Koper, P.C.M.4    Visser, A.G.5    Heijmen, B.J.M.6
  • 25
    • 0034535976 scopus 로고    scopus 로고
    • IMRT verification with a camera-based electronic portal imaging system
    • M. Partridge, J. R. N. Symonds-Tayler, and P. M. Evans, "IMRT verification with a camera-based electronic portal imaging system," Phys. Med. Biol. 45, N183-196 (2000).
    • (2000) Phys. Med. Biol. , vol.45
    • Partridge, M.1    Symonds-Tayler, J.R.N.2    Evans, P.M.3
  • 28
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • V. N. Hansen, P. M. Evans, and W. Swindell, "The application of transit dosimetry to precision radiotherapy," Med. Phys. 23. 713-721 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 29
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • D. A. Jaffray and J. H. Siewerdsen, "Cone-beam computed tomography with a flat-panel imager: Initial performance characterization," Med. Phys. 27, 1311-1323 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 31
  • 34
    • 0030866641 scopus 로고    scopus 로고
    • Extraction of primary signal from EPIDs using only forward convolution
    • V. N. Hansen, W. Swindell, and P. M. Evans, "Extraction of primary signal from EPIDs using only forward convolution," Med. Phys. 24, 1477-1484 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1477-1484
    • Hansen, V.N.1    Swindell, W.2    Evans, P.M.3
  • 35
    • 0021907462 scopus 로고
    • A convolution method of calculating dose for 15-MV x rays
    • T. R. Mackie, J. W. Scrimger, and J. J. Battista, "A convolution method of calculating dose for 15-MV x rays," Med. Phys. 12, 188-196 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 188-196
    • Mackie, T.R.1    Scrimger, J.W.2    Battista, J.J.3
  • 36
    • 74549190368 scopus 로고
    • GEANT - Detector description simulation tool
    • CERN, GEANT - Detector description simulation tool, CERN Program Library Long Writeup W5013, 1994.
    • (1994) CERN Program Library Long Writeup W5013
  • 38
    • 0037150138 scopus 로고    scopus 로고
    • A performance comparison of direct and indirect-detection flat-panel imagers
    • M. Partridge, B-M. Hesse, and L. Müller, "A performance comparison of direct and indirect-detection flat-panel imagers," Nucl. Instrum. Methods A 484, 351-363 (2002).
    • (2002) Nucl. Instrum. Methods A , vol.484 , pp. 351-363
    • Partridge, M.1    Hesse, B.-M.2    Müller, L.3
  • 39
    • 0025813557 scopus 로고
    • A linear diode scintillation crystal-photodiode detector for megavoltage imaging
    • E. J. Morton, W. Swindell, D. G. Lewis, and P. M. Evans, "A linear diode scintillation crystal-photodiode detector for megavoltage imaging," Med. Phys. 18, 681 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 681
    • Morton, E.J.1    Swindell, W.2    Lewis, D.G.3    Evans, P.M.4
  • 40
    • 0034879549 scopus 로고    scopus 로고
    • An iterative algorithm for reconstructing incident beam distributions from transmission measurements using electronic portal imaging
    • L. Spies, M. Partridge, B. A. Groh, and T. Bortfeld, "An iterative algorithm for reconstructing incident beam distributions from transmission measurements using electronic portal imaging," Phys. Med. Biol. 46, N203-211 (2001).
    • (2001) Phys. Med. Biol. , vol.46
    • Spies, L.1    Partridge, M.2    Groh, B.A.3    Bortfeld, T.4
  • 41
    • 0027719512 scopus 로고
    • Geometrical calibration for 3D x-ray imaging
    • A. Roguèe, C. Picard, Y. Trausset, and C. Ponchut, "Geometrical calibration for 3D x-ray imaging," Proc. SPIE 1897, 161-169 (1993).
    • (1993) Proc. SPIE , vol.1897 , pp. 161-169
    • Roguèe, A.1    Picard, C.2    Trausset, Y.3    Ponchut, C.4
  • 43
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • D. Low, W. B. Harms, S. Mutic, and J. A. Purdy, "A technique for the quantitative evaluation of dose distributions," Med. Phys. 25, 656-661 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 44
    • 0032706348 scopus 로고    scopus 로고
    • Dose calculations for external photon beams in radiotherapy
    • A. Ahnesjö and M. M. Aspradakis, "Dose calculations for external photon beams in radiotherapy," Phys. Med. Biol. 44, R99-R155 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Ahnesjö, A.1    Aspradakis, M.M.2