메뉴 건너뛰기




Volumn 25, Issue 10, 1998, Pages 1903-1909

The use of an electronic portal imaging system to measure portal dose and portal dose profiles

Author keywords

Portal dose profiles; Portal dosimetry; Portal imaging

Indexed keywords

DOSIMETRY; IMAGING SYSTEMS; IONIZATION OF LIQUIDS; SENSITIVITY ANALYSIS;

EID: 0031789184     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598379     Document Type: Article
Times cited : (32)

References (36)
  • 1
    • 0015968195 scopus 로고
    • Anatomic and geometric precision in radiotherapy
    • J. E Marks, M. D. Davis, and A. G. Haus, "Anatomic and geometric precision in radiotherapy," Radiol. Clin. Biol. 43, 1-20 (1974).
    • (1974) Radiol. Clin. Biol. , vol.43 , pp. 1-20
    • Marks, J.E.1    Davis, M.D.2    Haus, A.G.3
  • 2
    • 0017133803 scopus 로고
    • The value of frequent verification films in reducing localization error m the irradiation of complex fields
    • J. E. Marks, A. G. Haus, H. G. Sutton, and M. L. Griem, "The value of frequent verification films in reducing localization error m the irradiation of complex fields," Cancer 37, 2755-2761 (1976).
    • (1976) Cancer , vol.37 , pp. 2755-2761
    • Marks, J.E.1    Haus, A.G.2    Sutton, H.G.3    Griem, M.L.4
  • 7
    • 0026652358 scopus 로고
    • Assessment of geometric treatment accuracy using time lapse display of electronic portal imaging
    • L. E. Reinstem, S. Pai, and A. G. Meek, "Assessment of geometric treatment accuracy using time lapse display of electronic portal imaging," Int. J. Radiat. Oncol., Biol., Phys. 22, 1139-1146 (1992).
    • (1992) Int. J. Radiat. Oncol., Biol., Phys. , vol.22 , pp. 1139-1146
    • Reinstem, L.E.1    Pai, S.2    Meek, A.G.3
  • 9
    • 36149040555 scopus 로고
    • A liquid ionization detector for digital radiography of therapeutic megavoltage photon beams
    • H. Meertens, M. van Herk, and J. Weeda, "A liquid ionization detector for digital radiography of therapeutic megavoltage photon beams," Phys. Med. Biol. 30, 313-321 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 313-321
    • Meertens, H.1    Van Herk, M.2    Weeda, J.3
  • 10
    • 0023885087 scopus 로고
    • A matrix ionization chamber imaging device for on-line patient setup verification during radiotherapy
    • M. van Herk and H. Meertens, "A matrix ionization chamber imaging device for on-line patient setup verification during radiotherapy," Radiother. Oncol 11, 369-378 (1988).
    • (1988) Radiother. Oncol , vol.11 , pp. 369-378
    • Van Herk, M.1    Meertens, H.2
  • 11
    • 0025107872 scopus 로고
    • Therapy imaging: A signal to noise analysis of a fluoroscopic imaging system for radiotherapy localization
    • P. Munro, J A. Rawlinson, and A. Fenster, "Therapy imaging: A signal to noise analysis of a fluoroscopic imaging system for radiotherapy localization," Med. Phys. 17, 763-772 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 763-772
    • Munro, P.1    Rawlinson, J.A.2    Fenster, A.3
  • 14
    • 0025813557 scopus 로고
    • A linear array, scintillation crystal-photodiode detector for megavoltage imaging
    • E. J. Morton, W Swindell, D. G. Lewis, and P. M. Evans, "A linear array, scintillation crystal-photodiode detector for megavoltage imaging," Med Phys. 18, 681-691 (1991).
    • (1991) Med Phys. , vol.18 , pp. 681-691
    • Morton, E.J.1    Swindell, W.2    Lewis, D.G.3    Evans, P.M.4
  • 16
    • 0025895695 scopus 로고
    • Physical aspects of liquid-filled ionization chamber with pulsed polarizing voltage
    • M. van Herk, "Physical aspects of liquid-filled ionization chamber with pulsed polarizing voltage," Med. Phys. 18, 692-702 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 692-702
    • Van Herk, M.1
  • 20
    • 0028145651 scopus 로고
    • Input/output characteristics of a matrix ion-chamber electronic portal imaging device
    • F. F. Yin, M. C. Schell, and P. Rubin, "Input/output characteristics of a matrix ion-chamber electronic portal imaging device," Med. Phys. 21, 1447-1454 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1447-1454
    • Yin, F.F.1    Schell, M.C.2    Rubin, P.3
  • 23
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • M. C. Kirby and P. C. Williams, "The use of an electronic portal imaging device for exit dosimetry and quality control measurements," Int. J. Radiat. Oncol., Biol., Phys. 31, 593-603 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 24
    • 0029153633 scopus 로고
    • Portal dosimetry using a liquid ion chamber matrix: Dose response studies
    • Y. Zhu, X. Jiang, and J. Van Dyk, "Portal dosimetry using a liquid ion chamber matrix: Dose response studies," Med. Phys. 22, 1101-1106 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1101-1106
    • Zhu, Y.1    Jiang, X.2    Van Dyk, J.3
  • 25
    • 0028149975 scopus 로고
    • A technique of automating compensator design for lung correction using an electron portal imaging device
    • F. F. Yin, M. C. Schell, and P. Rubin, "A technique of automating compensator design for lung correction using an electron portal imaging device," Med. Phys. 21, 1729-1732 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1729-1732
    • Yin, F.F.1    Schell, M.C.2    Rubin, P.3
  • 26
    • 0029929964 scopus 로고    scopus 로고
    • Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
    • D. A. Low, Z. Li, and E. E. Klein, "Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device," Med. Phys. 23, 929-938 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 929-938
    • Low, D.A.1    Li, Z.2    Klein, E.E.3
  • 28
    • 0027141513 scopus 로고
    • Measurement possibilities using an electronic portal imaging device
    • M. C. Kirby and P. C. Williams, "Measurement possibilities using an electronic portal imaging device," Radiother. Oncol. 29, 237-243 (1993).
    • (1993) Radiother. Oncol. , vol.29 , pp. 237-243
    • Kirby, M.C.1    Williams, P.C.2
  • 29
    • 0025960367 scopus 로고
    • Comparison of entrance and exit dose measurements using ionization chambers and diodes
    • S. Heukelom, J. H. Lanson, and B. J. Mijnheer, "Comparison of entrance and exit dose measurements using ionization chambers and diodes," Phys. Med. Biol. 36, 47-59 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 47-59
    • Heukelom, S.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 30
    • 0029790894 scopus 로고    scopus 로고
    • Modeling dose distributions from portal dose images using the convolution/ superposition method
    • J. R. McNutt, T. R. Mackie, P. Reckwerdt, and B. R. Paliwal, "Modeling dose distributions from portal dose images using the convolution/ superposition method," Med. Phys. 23, 1381-1392 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1381-1392
    • McNutt, J.R.1    Mackie, T.R.2    Reckwerdt, P.3    Paliwal, B.R.4
  • 31
    • 0029814510 scopus 로고    scopus 로고
    • The dose response relationship of a liquid-filled electronic portal imaging device
    • R. Boellaard, M. van Herk, and B. J. Mijnheer, "The dose response relationship of a liquid-filled electronic portal imaging device," Med Phys. 23, 1601-1611 (1996).
    • (1996) Med Phys. , vol.23 , pp. 1601-1611
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 33
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high energy photon and electron beams
    • Amencan Association of Physicists in Medicine, RTC Task Group 21, "A protocol for the determination of absorbed dose from high energy photon and electron beams," Med. Phys. 10, 741-769 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 741-769
  • 36
    • 0028233920 scopus 로고
    • Midplane dose determination using in vivo dose measurements in combination with portal imaging
    • D. Huyskens, J. Van Dam, and A. Dutreix, "Midplane dose determination using in vivo dose measurements in combination with portal imaging," Phys. Med. Biol. 39, 1089-1101 (1194).
    • (1194) Phys. Med. Biol. , vol.39 , pp. 1089-1101
    • Huyskens, D.1    Van Dam, J.2    Dutreix, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.