Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model

Author keywords

Convolution model; Electronic portal imaging device; Exit dosimetry; In viva dosimetry; Portal imaging

Indexed keywords

ARTICLE; DEVICE; DIODE; DOSIMETRY; ELECTRONICS; IMAGING SYSTEM; NONHUMAN; PHANTOM; PRIORITY JOURNAL;

EID: 0030786466     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(97)00073-X     Document Type: Article
Times cited : (55)

References (26)
  • 1
    • 0027138281 scopus 로고
    • A verification procedure to improve patient setup accuracy using portal imaging
    • Bel, A., van Herk, M., Bartelink, H. and Lebesque, J.V. A verification procedure to improve patient setup accuracy using portal imaging. Radiother. Oncol. 29: 253-260, 1993.
    • (1993) Radiother. Oncol. , vol.29 , pp. 253-260
    • Bel, A.1    Van Herk, M.2    Bartelink, H.3    Lebesque, J.V.4
  • 2
    • 0025932046 scopus 로고
    • Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images
    • Bijhold, J., van Herk, M., Vijlbrief, R. and Lebesque, J.V. Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images. Phys. Med. Biol. 36:1665-1679, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1665-1679
    • Bijhold, J.1    Van Herk, M.2    Vijlbrief, R.3    Lebesque, J.V.4
  • 3
    • 0023847882 scopus 로고
    • Description of the scatter component in photon-beam data
    • Bjärngard, B.E. and Petti, P.L. Description of the scatter component in photon-beam data. Phys. Med. Biol. 33: 21-32, 1988.
    • (1988) Phys. Med. Biol. , vol.33 , pp. 21-32
    • Bjärngard, B.E.1    Petti, P.L.2
  • 4
    • 0031045088 scopus 로고    scopus 로고
    • A convolution model to convert transmission dose images to exit dose distributions
    • Boellaard, R., van Herk, M. and Mijnheer, B.J. A convolution model to convert transmission dose images to exit dose distributions. Med. Phys. 24: 189-199, 1997.
    • (1997) Med. Phys. , vol.24 , pp. 189-199
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 5
    • 0029814510 scopus 로고    scopus 로고
    • The dose response relationship of a liquid-filled electronic portal imaging device
    • Boellaard, R., van Herk, M. and Mijnheer, B.J. The dose response relationship of a liquid-filled electronic portal imaging device. Med. Phys. 23: 1601-1611, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1601-1611
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 6
    • 0001944192 scopus 로고
    • Accuracy requirements and quality assurance of external beam therapy with photons and electrons
    • Brahme, A., Chavaudra, J., Landberg, T. et al. Accuracy requirements and quality assurance of external beam therapy with photons and electrons. Acta Oncol. Suppl. 1, 1988.
    • (1988) Acta Oncol. Suppl. , vol.1
    • Brahme, A.1    Chavaudra, J.2    Landberg, T.3
  • 7
    • 0027145156 scopus 로고
    • In vivo dosimetry during conformal therapy of prostate cancer
    • Essers, M., Lanson, J.H. and Mijnheer, B.J. In vivo dosimetry during conformal therapy of prostate cancer. Radiother. Oncol. 29: 271-279, 1993.
    • (1993) Radiother. Oncol. , vol.29 , pp. 271-279
    • Essers, M.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 11
  • 12
    • 0029902253 scopus 로고    scopus 로고
    • On-line exit dose profile measurements by a diode linear array
    • Fiorino, C., Uleri, C., Cattaneo, G.M. and Calandrino, R. On-line exit dose profile measurements by a diode linear array. Phys. Med. Biol. 41: 1291-1304, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1291-1304
    • Fiorino, C.1    Uleri, C.2    Cattaneo, G.M.3    Calandrino, R.4
  • 13
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • Hansen, V.N., Evans, P.M. and Swindell, W. The application of transit dosimetry to precision radiotherapy. Med. Phys. 23: 713-721, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 15
    • 0003954913 scopus 로고
    • A system of dosimetric calculations
    • Editors: W.M. Passano III and C.B. Levy. Williams and Wilkins, Baltimore, MD
    • Khan, F.M. A system of dosimetric calculations. In: The Physics of Radiation Therapy, 2nd edn., pp. 200-225. Editors: W.M. Passano III and C.B. Levy. Williams and Wilkins, Baltimore, MD, 1994.
    • (1994) The Physics of Radiation Therapy, 2nd Edn. , pp. 200-225
    • Khan, F.M.1
  • 16
    • 0027141513 scopus 로고
    • Measurement possibilities using an electronic portal imaging device
    • Kirby, M.C. and Williams, P.C. Measurement possibilities using an electronic portal imaging device. Radiother. Oncol. 29: 237-243, 1993.
    • (1993) Radiother. Oncol. , vol.29 , pp. 237-243
    • Kirby, M.C.1    Williams, P.C.2
  • 17
    • 0026050773 scopus 로고
    • The simultaneous boost technique; the concept of relative normalised total dose
    • Lebesque, J.V. and Keus, R. The simultaneous boost technique; the concept of relative normalised total dose. Radiother. Oncol. 22: 45-55, 1991.
    • (1991) Radiother. Oncol. , vol.22 , pp. 45-55
    • Lebesque, J.V.1    Keus, R.2
  • 19
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy?
    • Mijnheer, B.J., Battermann, J.J. and Wambersie, A. What degree of accuracy is required and can be achieved in photon and neutron therapy? Radiother. Oncol. 8: 237-252, 1987.
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Battermann, J.J.2    Wambersie, A.3
  • 20
    • 0030047716 scopus 로고    scopus 로고
    • Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    • Swindell, W. and Evans, P.M. Scattered radiation in portal images: a Monte Carlo simulation and a simple physical model. Med. Phys. 23: 63-73, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 63-73
    • Swindell, W.1    Evans, P.M.2
  • 22
    • 0025895695 scopus 로고
    • Physical aspects of a liquid-filled ionization chamber with pulsed polarizing voltage
    • van Herk, M. Physical aspects of a liquid-filled ionization chamber with pulsed polarizing voltage. Med. Phys. 18: 692-702, 1991.
    • (1991) Med. Phys. , vol.18 , pp. 692-702
    • Van Herk, M.1
  • 23
    • 0023885087 scopus 로고
    • A matrix ionization chamber for online patient setup verification during radiotherapy
    • van Herk, M. and Meertens, H. A matrix ionization chamber for online patient setup verification during radiotherapy. Radiother. Oncol. 11: 369-378, 1988.
    • (1988) Radiother. Oncol. , vol.11 , pp. 369-378
    • Van Herk, M.1    Meertens, H.2
  • 24
    • 0028145651 scopus 로고
    • Input/output characteristics of a matrix ion-chamber portal imaging device
    • Yin, F.-F., Schell, M.C. and Rubin, P. Input/output characteristics of a matrix ion-chamber portal imaging device. Med. Phys. 21: 1447-1454, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1447-1454
    • Yin, F.-F.1    Schell, M.C.2    Rubin, P.3
  • 26
    • 0029153633 scopus 로고
    • Portal dosimetry using a liquid ion chamber matrix: Dose response studies
    • Zhu, Y., Jiang, X.Q. and Van Dyk, J. Portal dosimetry using a liquid ion chamber matrix: dose response studies. Med. Phys. 22: 1101-1106, 1995.
    • (1995) Med. Phys. , vol.22 , pp. 1101-1106
    • Zhu, Y.1    Jiang, X.Q.2    Van Dyk, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.