메뉴 건너뛰기




Volumn 39, Issue 4, 1997, Pages 863-873

Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate

Author keywords

DMLC; Dynamic multileaf collimator; Intensity modulation; Prostate cancer; Radiotherapy

Indexed keywords

ARTICLE; CANCER CONTROL; CANCER RADIOTHERAPY; COLLIMATOR; DOSIMETRY; HUMAN; HUMAN TISSUE; PRIORITY JOURNAL; PROSTATE CANCER; QUALITY CONTROL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SAFETY; TREATMENT PLANNING;

EID: 0030661596     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(97)00458-6     Document Type: Article
Times cited : (257)

References (30)
  • 2
    • 0025103658 scopus 로고
    • Methods of image reconstruction from projections applied to conformation radiotherapy
    • Bortfeld, T.; Burkelbach, J.; Boeseck, R.; Schlegel, W. Methods of image reconstruction from projections applied to conformation radiotherapy. Phys. Med. Biol. 35:1423-1434; 1990.
    • (1990) Phys. Med. Biol. , vol.35 , pp. 1423-1434
    • Bortfeld, T.1    Burkelbach, J.2    Boeseck, R.3    Schlegel, W.4
  • 6
    • 0028880490 scopus 로고
    • The influence of scatter on design of optimized intensity modulation
    • Chen, Z.; Wang, X.; Bortfeld, T.; Mohan, R.; Reinstein, L. The influence of scatter on design of optimized intensity modulation. Med. Phys. 22:1727-1733; 1995.
    • (1995) Med. Phys. , vol.22 , pp. 1727-1733
    • Chen, Z.1    Wang, X.2    Bortfeld, T.3    Mohan, R.4    Reinstein, L.5
  • 7
    • 0022515715 scopus 로고
    • Off-center ratios for three dimensional dose calculations
    • Chui, C.; Mohan, R. Off-center ratios for three dimensional dose calculations. Med. Phys. 13:409-412; 1986.
    • (1986) Med. Phys. , vol.13 , pp. 409-412
    • Chui, C.1    Mohan, R.2
  • 10
    • 0003639045 scopus 로고
    • International commission on radiation units and measurements
    • Bethesda, MD: International Commission on Radiation Units and Measurements
    • International Commission on Radiation Units and measurements. ICRU Report 50: Prescribing, recording, and reporting photon beam therapy. Bethesda, MD: International Commission on Radiation Units and Measurements; 1993:3-16.
    • (1993) ICRU Report 50: Prescribing, Recording, and Reporting Photon Beam Therapy , pp. 3-16
  • 11
    • 0024317128 scopus 로고
    • Calculation of complication probability factors for nonuniform normal tissue irradiation: The effective volume method
    • Kutcher, G. J.; Burman, C. Calculation of complication probability factors for nonuniform normal tissue irradiation: The effective volume method. Int. J. Radiat. Oncol. Biol. Phys. 16:1623-1630; 1989.
    • (1989) Int. J. Radiat. Oncol. Biol. Phys. , vol.16 , pp. 1623-1630
    • Kutcher, G.J.1    Burman, C.2
  • 12
    • 0029941575 scopus 로고    scopus 로고
    • Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: Further evidence for a significant dose effect
    • Lee, W. R.; Hanks, G. E.; Hanlon, A. L.; Schultheiss, T. E.; Hunt, M. A. Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: Further evidence for a significant dose effect. Int. J. Radiat. Oncol. Biol. Phys. 35:251-257; 1996.
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 251-257
    • Lee, W.R.1    Hanks, G.E.2    Hanlon, A.L.3    Schultheiss, T.E.4    Hunt, M.A.5
  • 17
    • 0022323855 scopus 로고
    • Complication probability as assessed from dose-volume histograms
    • Lyman, J. T. Complication probability as assessed from dose-volume histograms. Radiat. Res. 104:S13-S19; 1985.
    • (1985) Radiat. Res. , vol.104
    • Lyman, J.T.1
  • 19
    • 0023118553 scopus 로고
    • Use of fast Fourier transforms in calculating dose distributions for irregularly shaped fields for three-dimensional treatment planning
    • Mohan, R.; Chui, C. Use of fast Fourier transforms in calculating dose distributions for irregularly shaped fields for three-dimensional treatment planning. Med Phys. 14:70-77; 1987.
    • (1987) Med Phys. , vol.14 , pp. 70-77
    • Mohan, R.1    Chui, C.2
  • 20
    • 0021849353 scopus 로고
    • Energy and angular distributions of photons from medical linear accelerators
    • Mohan, R.; Chui, C.; Lidofsky, L. Energy and angular distributions of photons from medical linear accelerators. Med. Phys. 12:592-597; 1985.
    • (1985) Med. Phys. , vol.12 , pp. 592-597
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3
  • 25
    • 0029704069 scopus 로고    scopus 로고
    • 3-D conformal radiotherapy for prostate cancer
    • Mayers, J. L.; Purdy, J. A. eds. Basel: Karger
    • Sandler, H. M. 3-D conformal radiotherapy for prostate cancer. In: Mayers, J. L.; Purdy, J. A. eds. 3D conformal Radiotherapy. Frontiers in Radiation Therapy and Oncology. Basel: Karger; Vol 29. 1996:238-243.
    • (1996) 3D Conformal Radiotherapy. Frontiers in Radiation Therapy and Oncology , vol.29 , pp. 238-243
    • Sandler, H.M.1
  • 26
    • 0026580119 scopus 로고
    • Dose eescaltion for stage C (T3) prostate cancer: Minimal rectal toxicity observed using conformal therapy
    • Sandler, H. M.; Perez-Tamayo, C.: Ten Haken, R. K.; Lichter, A. S. Dose eescaltion for stage C (T3) prostate cancer: Minimal rectal toxicity observed using conformal therapy. Radiother. Oncol. 23:53-54; 1992.
    • (1992) Radiother Oncol. , vol.23 , pp. 53-54
    • Sandler, H.M.1    Perez-Tamayo, C.2    Ten Haken, R.K.3    Lichter, A.S.4
  • 27
    • 0028144837 scopus 로고
    • Generation of arbitrary fluence profiles by dynamic jaws or multileaf collimators
    • Spirou, S. V.; Chui, C. S. Generation of arbitrary fluence profiles by dynamic jaws or multileaf collimators. Med. Phys. 21:1031-1041; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1031-1041
    • Spirou, S.V.1    Chui, C.S.2
  • 28
    • 0029865277 scopus 로고    scopus 로고
    • Dosimetric verification of an intensity modulated treatment
    • Wang, X.; Spirou, S.; LoSasso, T.; Chui, C. S.; Mohan, R. Dosimetric verification of an intensity modulated treatment. Med. Phys. 23:317-327; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 317-327
    • Wang, X.1    Spirou, S.2    LoSasso, T.3    Chui, C.S.4    Mohan, R.5
  • 29
    • 0342499535 scopus 로고    scopus 로고
    • The choice of inverse technique parameters for optimizing intensity-modulated 3D conformal prostate treatment
    • Yang, J.; Wu, Q.; Stein, J.; Mohan, R. The choice of inverse technique parameters for optimizing intensity-modulated 3D conformal prostate treatment (Abstr.). Med. Phys. 23:1075; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1075
    • Yang, J.1    Wu, Q.2    Stein, J.3    Mohan, R.4
  • 30
    • 33750105636 scopus 로고
    • The feasibility of dose escalation with tree-dimensional conformal radiotherapy with patients with prostatic carcinoma
    • Zelefsky, M. J.; Leibel, S. A.; Kutcher, G. J.; Kelson, S.; Ling, C. C.; Fuks, Z. The feasibility of dose escalation with tree-dimensional conformal radiotherapy with patients with prostatic carcinoma. Cancer J. 1:142-150; 1995.
    • (1995) Cancer J. , vol.1 , pp. 142-150
    • Zelefsky, M.J.1    Leibel, S.A.2    Kutcher, G.J.3    Kelson, S.4    Ling, C.C.5    Fuks, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.