메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages

A study of the spectral response of portal imaging detectors

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; IMAGING SYSTEMS; MONTE CARLO METHODS; PHOTONS; RADIOTHERAPY;

EID: 0034593868     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (8)
  • 1
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • VN Hansen, PM Evans and W Swindell, "The application of transit dosimetry to precision radiotherapy" Med. Phys. 23 713-21 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 2
    • 0032717807 scopus 로고    scopus 로고
    • Dosimetric verification of intensity modulated beams produced by dynamic multileaf collimation using an electronic portal imaging device
    • KL Pasma, MLP Dirx, M Kroonwijk, AG Visser and BJM Heijmen, "Dosimetric verification of intensity modulated beams produced by dynamic multileaf collimation using an electronic portal imaging device" Med. Phys. 26 2373-8 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2373-2378
    • Pasma, K.L.1    Dirx, M.L.P.2    Kroonwijk, M.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 3
    • 0030047716 scopus 로고    scopus 로고
    • Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    • W Swindell and PM Evans, "Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model" Med. Phys. 23 63-73 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 63-73
    • Swindell, W.1    Evans, P.M.2
  • 4
    • 0033739848 scopus 로고    scopus 로고
    • Scatter rejection methods in megavoltage imaging with an amorphous silicon flat panel array
    • BA Groh, L Spies, BM Hesse, T Bortfeld, "Scatter rejection methods in megavoltage imaging with an amorphous silicon flat panel array" Proc. Medical Imaging 2000 SPIE vol. 3977 pp.601-8 (2000).
    • (2000) Proc. Medical Imaging 2000 SPIE , vol.3977 , pp. 601-608
    • Groh, B.A.1    Spies, L.2    Hesse, B.M.3    Bortfeld, T.4
  • 5
    • 0034023788 scopus 로고    scopus 로고
    • Direct measurement and analytical modeling of scatter in portal imaging
    • L Spies, PM Evans, M Partridge, VN Hansen and T Bortfeld, "Direct measurement and analytical modeling of scatter in portal imaging" Med. Phys. 27 462-71 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 462-471
    • Spies, L.1    Evans, P.M.2    Partridge, M.3    Hansen, V.N.4    Bortfeld, T.5
  • 6
    • 0003640959 scopus 로고
    • GEANT - Detector description simulation tool
    • CERN; CERN Program Library Long Writeup W5013
    • CERN. GEANT - Detector description simulation tool. CERN Program Library Long Writeup W5013 (1994).
    • (1994)
  • 7
    • 0034005794 scopus 로고    scopus 로고
    • Monte Carlo studies of the exit photon spectra and dose to a metal/phosphor portal imaging screen
    • C Yeboah and S Pistorius, "Monte Carlo studies of the exit photon spectra and dose to a metal/phosphor portal imaging screen" Med. Phys. 27 330-9 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 330-339
    • Yeboah, C.1    Pistorius, S.2
  • 8
    • 0029144630 scopus 로고
    • Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography
    • DA Jaffray, JJ Battista, A Fenster and P Munro, "Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography" Med. Phys. 22 1077-88 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1077-1088
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.