-
1
-
-
0031033642
-
Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip
-
Barrack R.L., Folgueras A., Munn B., Tvetden D., Sharkey P. Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip. Clinical Orthopaedics. 335:1997;211-217.
-
(1997)
Clinical Orthopaedics
, vol.335
, pp. 211-217
-
-
Barrack, R.L.1
Folgueras, A.2
Munn, B.3
Tvetden, D.4
Sharkey, P.5
-
3
-
-
0030878106
-
Postmortem analysis of bone growth into porous-coated acetabular components
-
Bloebaum R.D., Mihalopoulus N.L., Jensen J.W., Dorr L.D. Postmortem analysis of bone growth into porous-coated acetabular components. Journal of Bone and Joint Surgery, American. 79:1997;1013-1022.
-
(1997)
Journal of Bone and Joint Surgery, American
, vol.79
, pp. 1013-1022
-
-
Bloebaum, R.D.1
Mihalopoulus, N.L.2
Jensen, J.W.3
Dorr, L.D.4
-
4
-
-
0029024044
-
Polyethylene wear debris in modular acetabular prostheses
-
Chen, P.C., Mead, E.H., Pinto, J.G., Colwell, C.W., Jr., 1995. Polyethylene wear debris in modular acetabular prostheses. Clinical Orthopaedics, 44-56.
-
(1995)
Clinical Orthopaedics
, pp. 44-56
-
-
Chen, P.C.1
Mead, E.H.2
Pinto, J.G.3
Colwell C.W., Jr.4
-
5
-
-
0026443513
-
Mechanisms of failure of modular prostheses
-
Collier J.P., Mayor M.B., Jensen R.E., Surprenant V.A., Surprenant H.P., McNamar J.L., Belec L. Mechanisms of failure of modular prostheses. Clinical Orthopaedics. 285:1992;129-139.
-
(1992)
Clinical Orthopaedics
, vol.285
, pp. 129-139
-
-
Collier, J.P.1
Mayor, M.B.2
Jensen, R.E.3
Surprenant, V.A.4
Surprenant, H.P.5
McNamar, J.L.6
Belec, L.7
-
6
-
-
0025678867
-
The biomechanical problems of polyethylene as a bearing surface
-
Collier J.P., Mayor M.B., Surprenant V.A., Surprenant H.P., Dauphinais L.A., Jensen R.E. The biomechanical problems of polyethylene as a bearing surface. Clinical Orthopaedics. 261:1990;107-113.
-
(1990)
Clinical Orthopaedics
, vol.261
, pp. 107-113
-
-
Collier, J.P.1
Mayor, M.B.2
Surprenant, V.A.3
Surprenant, H.P.4
Dauphinais, L.A.5
Jensen, R.E.6
-
7
-
-
0344052275
-
Relative motion at the backside of a metal-backed acetabular component under quasistatic and dynamic loading
-
Cournoyer J.R., Ochoa J.A., Kurtz S.M. Relative motion at the backside of a metal-backed acetabular component under quasistatic and dynamic loading. Transactions of Orthopaedics Research Society. 22:1997;839.
-
(1997)
Transactions of Orthopaedics Research Society
, vol.22
, pp. 839
-
-
Cournoyer, J.R.1
Ochoa, J.A.2
Kurtz, S.M.3
-
10
-
-
0031443897
-
Uncemented total hip arthroplasty in patients 50 years of age or younger
-
Dowdy P.A., Rorabeck C.H., Bourne R.B. Uncemented total hip arthroplasty in patients 50 years of age or younger. Journal of Arthroplasty. 12:1997;853-862.
-
(1997)
Journal of Arthroplasty
, vol.12
, pp. 853-862
-
-
Dowdy, P.A.1
Rorabeck, C.H.2
Bourne, R.B.3
-
11
-
-
0030684911
-
Wear coefficient for reference UHMWPE in a biaxial rocking hip simulator
-
1997
-
Estupiñán, J.A., Furman, B.D., Li, S., Bartel, D.L., 1997. Wear coefficient for reference UHMWPE in a biaxial rocking hip simulator. 1997 Bioengineering Conference (ASME) 35, 159-160.
-
(1997)
Bioengineering Conference (ASME)
, vol.35
, pp. 159-160
-
-
Estupiñán, J.A.1
Furman, B.D.2
Li, S.3
Bartel, D.L.4
-
12
-
-
0345482375
-
-
Guttmann, D., Schmalzried, T.P., Kabo, J.M., Amstutz, H.C., 1994. 40th Orthopedic Research Society, p. 178.
-
(1994)
40th Orthopedic Research Society
, pp. 178
-
-
Guttmann, D.1
Schmalzried, T.P.2
Kabo, J.M.3
Amstutz, H.C.4
-
13
-
-
0028245867
-
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
-
Huk O.L., Bansal M., Betts F., Rimnac C.M., Lieberman J.R., Huo M.H., Salvati E.A. Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. Journal of Bone and Joint Surgery, American. 76:1994;568-574.
-
(1994)
Journal of Bone and Joint Surgery, American
, vol.76
, pp. 568-574
-
-
Huk, O.L.1
Bansal, M.2
Betts, F.3
Rimnac, C.M.4
Lieberman, J.R.5
Huo, M.H.6
Salvati, E.A.7
-
14
-
-
0030903723
-
Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
-
Jasty M., Goetz D.D., Bragdon C.R., Lee K.R., Hanson A.E., Elder J.R., Harris W.H. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. Journal of Bone and Joint Surgery, American. 79:1997;349-358.
-
(1997)
Journal of Bone and Joint Surgery, American
, vol.79
, pp. 349-358
-
-
Jasty, M.1
Goetz, D.D.2
Bragdon, C.R.3
Lee, K.R.4
Hanson, A.E.5
Elder, J.R.6
Harris, W.H.7
-
17
-
-
0001440129
-
The effect of non-conformity between metal backing and polyethylene inserts in acetabular components for total hip arthroplasty
-
Kurtz S.M., Gabriel S.M., Bartel D.L. The effect of non-conformity between metal backing and polyethylene inserts in acetabular components for total hip arthroplasty. Transactions of Orthopaedics Research Society. 18:1993;434.
-
(1993)
Transactions of Orthopaedics Research Society
, vol.18
, pp. 434
-
-
Kurtz, S.M.1
Gabriel, S.M.2
Bartel, D.L.3
-
18
-
-
0032071068
-
Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
-
Kurtz S.M., Ochoa J.A., White C.V., Srivastav S., Cournoyer J. Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. Journal of Biomechanics. 31:1998;431-437.
-
(1998)
Journal of Biomechanics
, vol.31
, pp. 431-437
-
-
Kurtz, S.M.1
Ochoa, J.A.2
White, C.V.3
Srivastav, S.4
Cournoyer, J.5
-
19
-
-
0029829977
-
Wear of the polyethylene liner-metallic shell interface in modular acetabular components
-
Lieberman J.R., Kay R.M., Hamlet W.P., Park S.H., Kabo J.M. Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis. Journal of Arthroplasty. 11:1996;602-608.
-
(1996)
An in Vitro Analysis. Journal of Arthroplasty
, vol.11
, pp. 602-608
-
-
Lieberman, J.R.1
Kay, R.M.2
Hamlet, W.P.3
Park, S.H.4
Kabo, J.M.5
-
21
-
-
0030345394
-
The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear
-
Maxian T.A., Brown T.D., Pedersen D.R., Callaghan J.J. The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear. Clinical Orthopaedics. 333:1996;41-50.
-
(1996)
Clinical Orthopaedics
, vol.333
, pp. 41-50
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
22
-
-
0030152744
-
A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty
-
Maxian T.A., Brown T.D., Pedersen D.R., Callaghan J.J. A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. Journal of Biomechanics. 29:1996;687-692.
-
(1996)
Journal of Biomechanics
, vol.29
, pp. 687-692
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
23
-
-
0030698011
-
Finite element analysis of acetabular wear
-
Maxian, T.A., Brown, T.D., Pedersen, D.R., McKellop, H.A., Lu, B., Callaghan, J.J., 1997. Finite element analysis of acetabular wear. Validation, and backing and fixation effects. Clinical Orthopaedics, 111-117.
-
(1997)
Validation, and Backing and Fixation Effects. Clinical Orthopaedics
, pp. 111-117
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
McKellop, H.A.4
Lu, B.5
Callaghan, J.J.6
-
24
-
-
0031943675
-
Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical liners
-
Perez R.E., Rodriguez J.A., Deshmukh R.G., Ranawat C.S. Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical liners. Journal of Arthroplasty. 13:1998;1-7.
-
(1998)
Journal of Arthroplasty
, vol.13
, pp. 1-7
-
-
Perez, R.E.1
Rodriguez, J.A.2
Deshmukh, R.G.3
Ranawat, C.S.4
-
25
-
-
0008291702
-
Predicting the clinical wear performance of orthopaedic bearing surfaces
-
In: Jacobs J.J., Craig T.L., (Eds.,) ASTM STP 1346, American Society for Testing and Materials, West Conshohoken
-
Sauer, W.L., Anthony, M.E., 1998. Predicting the clinical wear performance of orthopaedic bearing surfaces. In: Jacobs J.J., Craig T.L., (Eds.,) Alternative Bearing Surfaces in Total Joint Replacement. ASTM STP 1346, American Society for Testing and Materials, West Conshohoken.
-
(1998)
Alternative Bearing Surfaces in Total Joint Replacement
-
-
Sauer, W.L.1
Anthony, M.E.2
-
26
-
-
0028198810
-
The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
-
Schmalzried T.P., Guttmann D., Grecula M., Amstutz H.C. The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. Journal of Bone Joint Surgery American. 76:1994;677-688.
-
(1994)
Journal of Bone Joint Surgery American
, vol.76
, pp. 677-688
-
-
Schmalzried, T.P.1
Guttmann, D.2
Grecula, M.3
Amstutz, H.C.4
-
27
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy
-
Schmalzried T.P., Kwong L.M., Jasty M., Sedlacek R.C., Haire T.C., O'Connor D.O., Bragdon C.R., Kabo J.M., Malcolm A.J., Harris W.H. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clinical Orthopaedics. 274:1992;60-78.
-
(1992)
Clinical Orthopaedics
, vol.274
, pp. 60-78
-
-
Schmalzried, T.P.1
Kwong, L.M.2
Jasty, M.3
Sedlacek, R.C.4
Haire, T.C.5
O'Connor, D.O.6
Bragdon, C.R.7
Kabo, J.M.8
Malcolm, A.J.9
Harris, W.H.10
-
28
-
-
0030701661
-
Effect of load angle on mechanical behavior of cemented acetabular cups
-
Schmidt, P.N., Bartel, D.L., 1997. Effect of load angle on mechanical behavior of cemented acetabular cups. 1997 Bioengineering Conference (ASME) 35, 59-60.
-
(1997)
1997 Bioengineering Conference (ASME)
, vol.35
, pp. 59-60
-
-
Schmidt, P.N.1
Bartel, D.L.2
-
29
-
-
0020862459
-
Dynamic relaxation
-
T.J.R. Hughes, & T. Belytschko. Amsterdam: North-Holland
-
Underwood P. Dynamic relaxation. Hughes T.J.R., Belytschko T. Computational Methods for Transient Analysis. 1983;245-267 North-Holland, Amsterdam.
-
(1983)
Computational Methods for Transient Analysis
, pp. 245-267
-
-
Underwood, P.1
-
31
-
-
0006544376
-
Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene
-
230-241
-
Wang, A., Sun, D.C., Yau, S.-S., Edwards, B., Sokol, M., Essner, A., Polineni, V.K., Stark, C., Dumbleton, J.H., 1997. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene. Wear 203-204, 230-241.
-
(1997)
Wear
, pp. 203-204
-
-
Wang, A.1
Sun, D.C.2
Yau, S.-S.3
Edwards, B.4
Sokol, M.5
Essner, A.6
Polineni, V.K.7
Stark, C.8
Dumbleton, J.H.9
-
33
-
-
0029023199
-
Osteolysis around an uncemented cobalt chrome total hip arthroplasty
-
Xenos J.S., Hopkinson W.J., Callaghan J.J., Heekin R.D., Savory C.G. Osteolysis around an uncemented cobalt chrome total hip arthroplasty. Clinical Orthopaedics. 317:1995;29-36.
-
(1995)
Clinical Orthopaedics
, vol.317
, pp. 29-36
-
-
Xenos, J.S.1
Hopkinson, W.J.2
Callaghan, J.J.3
Heekin, R.D.4
Savory, C.G.5
|