메뉴 건너뛰기




Volumn 12, Issue 1, 1997, Pages 25-31

Fixation of ultrahigh-molecular-weight polyethylene liners to metal- backed acetabular cups

Author keywords

acetabulum; implant design; polyethylene; total hip arthroplasty; wear

Indexed keywords

POLYETHYLENE;

EID: 0031059184     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(97)90043-7     Document Type: Article
Times cited : (43)

References (14)
  • 1
    • 0025678867 scopus 로고
    • The biomechanical problems of polyethylene as a bearing surface
    • Collier P, Mayor MB, Supprenant BA et al: The biomechanical problems of polyethylene as a bearing surface. Clin Orthop 261:107, 1990
    • (1990) Clin Orthop , vol.261 , pp. 107
    • Collier, P.1    Mayor, M.B.2    Supprenant, B.A.3
  • 3
    • 0026605414 scopus 로고
    • Mechanisms and clinical significance of wear debrisinduced osteolysis
    • Amstutz HC, Campbell P, Kossovsky N, Clarke IC: Mechanisms and clinical significance of wear debrisinduced osteolysis. Clin Orthop 276:7, 1992
    • (1992) Clin Orthop , vol.276 , pp. 7
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.C.4
  • 4
    • 0026470190 scopus 로고
    • Systemic distribution of wear debris after hip replacement
    • Langkamer VG, Case CP, Heap P et al: Systemic distribution of wear debris after hip replacement. J Bone Joint Surg 74B:831, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 831
    • Langkamer, V.G.1    Case, C.P.2    Heap, P.3
  • 5
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty
    • Schmalzried TP, Kwong LM, Jasty M et al: The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Clin Orthop 274:60, 1992
    • (1992) Clin Orthop , vol.274 , pp. 60
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 7
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OL, Bansal M, Betts F et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg 76B:568, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 568
    • Huk, O.L.1    Bansal, M.2    Betts, F.3
  • 9
    • 0024000543 scopus 로고
    • Wear, creep, and frictional heating of femoral implant articulating surfaces and the effect on long-term performance. Part II. Friction, heating, and torque
    • Davidson JA, Schwartz G, Lynch G, Gir S: Wear, creep, and frictional heating of femoral implant articulating surfaces and the effect on long-term performance. Part II. Friction, heating, and torque. J Biomed Mater Res 22:69, 1988
    • (1988) J Biomed Mater Res , vol.22 , pp. 69
    • Davidson, J.A.1    Schwartz, G.2    Lynch, G.3    Gir, S.4
  • 10
    • 0029027099 scopus 로고
    • Effect of polyethylene quality on wear in total knee arthroplasty
    • Tanner MG, Whiteside LA, White SE: Effect of polyethylene quality on wear in total knee arthroplasty. Clin Orthop 317:83, 1995
    • (1995) Clin Orthop , vol.317 , pp. 83
    • Tanner, M.G.1    Whiteside, L.A.2    White, S.E.3
  • 11
    • 85030288198 scopus 로고
    • The effect of cup design on particulate penetration of the acetabular interface
    • Boston, MA, April
    • Goldberg BA, Noble PC: The effect of cup design on particulate penetration of the acetabular interface. Presented at the 20th Annual Meeting of the Society for Biomaterials, Boston, MA, April 1994
    • (1994) 20th Annual Meeting of the Society for Biomaterials
    • Goldberg, B.A.1    Noble, P.C.2
  • 13
    • 0028121040 scopus 로고
    • Concerns with modularity in total hip arthroplasty
    • Bobyn JD, Tanzer M, Krygier JJ et al: Concerns with modularity in total hip arthroplasty. Clin Orthop 298:27, 1994
    • (1994) Clin Orthop , vol.298 , pp. 27
    • Bobyn, J.D.1    Tanzer, M.2    Krygier, J.J.3
  • 14
    • 0028243267 scopus 로고
    • Catastrophic failure of the polyethylene liner of uncemented acetabular components
    • Berry DJ, Barnes CL, Scott RD et al: Catastrophic failure of the polyethylene liner of uncemented acetabular components. J Bone Joint Surg 76B:575, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 575
    • Berry, D.J.1    Barnes, C.L.2    Scott, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.