메뉴 건너뛰기




Volumn 11, Issue 5, 1996, Pages 602-608

Wear of the polyethylene liner-metallic shell interface in modular acetabular components: An in vitro analysis

Author keywords

acetabular components; polyethylene; total hip arthroplasty; wear modularity

Indexed keywords

CHROMIUM; COBALT; GOLD; METAL; POLYETHYLENE; TITANIUM;

EID: 0029829977     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80116-1     Document Type: Article
Times cited : (35)

References (12)
  • 1
    • 0025649634 scopus 로고
    • Disassociation of acetabular components after total hip arthroplasty
    • Brien WW, Salvati EA, Wright TM et al: Disassociation of acetabular components after total hip arthroplasty. J Bone Joint Surg 72A:1548, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 1548
    • Brien, W.W.1    Salvati, E.A.2    Wright, T.M.3
  • 2
    • 0024551056 scopus 로고
    • Disassociation of a metal-backed polyethylene acetabular component
    • Bueche MJ, Herzenberg JE, Stubbs BT: Disassociation of a metal-backed polyethylene acetabular component. J Arthroplasty 4:39, 1989
    • (1989) J Arthroplasty , vol.4 , pp. 39
    • Bueche, M.J.1    Herzenberg, J.E.2    Stubbs, B.T.3
  • 3
    • 0025319780 scopus 로고
    • Disassembly of a modular acetabular component of a total hip arthroplasty
    • Kitziner KJ, DeLee J, Evans JA: Disassembly of a modular acetabular component of a total hip arthroplasty. J Bone Joint Surg 72A:621, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 621
    • Kitziner, K.J.1    DeLee, J.2    Evans, J.A.3
  • 4
    • 0027380702 scopus 로고
    • A comparison of the disassociation strength of modular acetabular components
    • Tradonsky S, Postak PD, Froimson AL, Greenwald AS: A comparison of the disassociation strength of modular acetabular components. Clin Orthop 296:154, 1993
    • (1993) Clin Orthop , vol.296 , pp. 154
    • Tradonsky, S.1    Postak, P.D.2    Froimson, A.L.3    Greenwald, A.S.4
  • 5
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material on stresses on ultra-high molecular weight components for total joint replacement
    • Bartel DL, Bidinell VL, Wright TM: The effect of conformity, thickness and material on stresses on ultra-high molecular weight components for total joint replacement. J Bone Joint Surg 68A:1041, 1986
    • (1986) J Bone Joint Surg , vol.68 A , pp. 1041
    • Bartel, D.L.1    Bidinell, V.L.2    Wright, T.M.3
  • 6
    • 0025678867 scopus 로고
    • The biomechanical problems of polyethylene as a bearing surface
    • Collier JP, Mayor MD, Suprenant VA et al: The biomechanical problems of polyethylene as a bearing surface. Clin Orthop 261:107, 1990
    • (1990) Clin Orthop , vol.261 , pp. 107
    • Collier, J.P.1    Mayor, M.D.2    Suprenant, V.A.3
  • 7
    • 0026443513 scopus 로고
    • Mechanisms of failure of modular prostheses
    • Collier JP, Mayor MB, Jensen RE et al: Mechanisms of failure of modular prostheses. Clin Orthop 285:129, 1992
    • (1992) Clin Orthop , vol.285 , pp. 129
    • Collier, J.P.1    Mayor, M.B.2    Jensen, R.E.3
  • 8
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OL, Bansal M, Betts F et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg 76B:568, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 568
    • Huk, O.L.1    Bansal, M.2    Betts, F.3
  • 9
    • 0020623582 scopus 로고
    • Frictional torque in surface and conventional hip replacement
    • Ma SM, Kabo JM, Amstutz HC: Frictional torque in surface and conventional hip replacement. J Bone Joint Surg 65A:366, 1983
    • (1983) J Bone Joint Surg , vol.65 A , pp. 366
    • Ma, S.M.1    Kabo, J.M.2    Amstutz, H.C.3
  • 10
    • 0022219799 scopus 로고
    • Direction and role of socket wear in Charnley low-friction arthroplasty
    • Wroblewski BM: Direction and role of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg 67B:757, 1985
    • (1985) J Bone Joint Surg , vol.67 B , pp. 757
    • Wroblewski, B.M.1
  • 12
    • 0000398089 scopus 로고
    • Wear of acetabular cups of conventional and modified UHMW polyethylenes compared on a hip joint simulator
    • Washington, DC, February
    • McKellop H, Lu B, Li S: Wear of acetabular cups of conventional and modified UHMW polyethylenes compared on a hip joint simulator. Presented at 38th Annual Meeting of the Orthopaedic Research Society, Washington, DC, February 1992
    • (1992) 38th Annual Meeting of the Orthopaedic Research Society
    • McKellop, H.1    Lu, B.2    Li, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.