메뉴 건너뛰기




Volumn 18, Issue 3, 2002, Pages 408-418

Analysis of 42 major and trace elements in glass standard reference materials by 193nm LA-ICPMS;193nm LA-ICPMS对国际地质标准参考物质中42种主量和微量元素的分析

Author keywords

Excimer laser; Glass standard reference materials; ICP MS; Laser ablation; Trace elements

Indexed keywords


EID: 85168633408     PISSN: 10000569     EISSN: 20958927     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (85)

References (19)
  • 1
    • 0032475564 scopus 로고    scopus 로고
    • Inorganic trace analysis by mass spectrometry
    • Becker J S, Dietze H-J. 1998. Inorganic trace analysis by mass spectrometry. Spectrochimica Acta Part B : 1475— 1506
    • (1998) Spectrochimica Acta Part B , pp. 1475-1506
    • Becker, J S1    Dietze, H-J.2
  • 2
    • 0001774301 scopus 로고    scopus 로고
    • Reference materials for geochemical studies : New analytical data by ICP-MS and critical discussion of reference values
    • Dulski P. 2001. Reference materials for geochemical studies : New analytical data by ICP-MS and critical discussion of reference values. Geostandards Newsletter, 25: 87— 125
    • (2001) Geostandards Newsletter , vol.25 , pp. 87-125
    • Dulski, P.1
  • 3
    • 0030740097 scopus 로고    scopus 로고
    • A simple method for the precise determination of ≥ 40 trace elements in geological samples by ICPMS using enriched isotope internal standardisation
    • Eggins S M, Woodhead J D, Kinsley L P J, Mortimer G E, Sylvester P, McCulloch M T, Hert J M and Handler M R. 1997. A simple method for the precise determination of ≥ 40 trace elements in geological samples by ICPMS using enriched isotope internal standardisation. Chemical Geology, 134, 311—326
    • (1997) Chemical Geology , vol.134 , pp. 311-326
    • Eggins, S M1    Woodhead, J D2    Kinsley, L P J3    Mortimer, G E4    Sylvester, P5    McCulloch, M T6    Hert, J M7    Handler, M R.8
  • 4
    • 0012112201 scopus 로고    scopus 로고
    • Analysis of forty-two major and trace elements of USGS and NIST S R M Glasses by LA-ICPMS
    • (in press)
    • Gao S, Liu X M, Yuan H L, Harttendorf B, G ünther D, Hu SH. 2002. Analysis of forty-two major and trace elements of USGS and NIST S R M Glasses by LA-ICPMS. Geostandard Newsletters (in press)
    • (2002) Geostandard Newsletters
    • Gao, S1    Liu, X M2    Yuan, H L3    Harttendorf, B4    G ünther, D5    Hu, SH.6
  • 5
    • 0031233821 scopus 로고    scopus 로고
    • Capabilities of an Argon Fluoride 193 nm Excimer Laser Ablation Coupled Plasma mass Spectrometry Microanalysis of Geological Materials
    • Günther D, Frischknecht R, Heinrich C A. 1997. Capabilities of an Argon Fluoride 193 nm Excimer Laser Ablation Coupled Plasma mass Spectrometry Microanalysis of Geological Materials. J. Anal. At. Spectrom., 12: 939—944
    • (1997) J. Anal. At. Spectrom , vol.12 , pp. 939-944
    • Günther, D1    Frischknecht, R2    Heinrich, C A.3
  • 6
    • 0345237256 scopus 로고    scopus 로고
    • Laser ablation and arc/sparc solid sample introduction into inductively coupled plasma mass spectrometers
    • Günther D, Jackson S E and Longerich H P. 1999. Laser ablation and arc/sparc solid sample introduction into inductively coupled plasma mass spectrometers. Spectrochimica Acta Part B, 54:381-409
    • (1999) Spectrochimica Acta Part B , vol.54 , pp. 381-409
    • Günther, D1    Jackson, S E2    Longerich, H P.3
  • 7
    • 0041912444 scopus 로고    scopus 로고
    • Enhanced sensitivity in laser ablation— ICP mass spectrometry using helium-argon mixtures as aerosol carrier
    • Günther D, Heinrich C A. 1999. Enhanced sensitivity in laser ablation— ICP mass spectrometry using helium-argon mixtures as aerosol carrier. J. Anal. At. Spectrom., 14: 1363— 1368
    • (1999) J. Anal. At. Spectrom , vol.14 , pp. 1363-1368
    • Günther, D1    Heinrich, C A.2
  • 8
    • 0043216512 scopus 로고    scopus 로고
    • Comparision of the ablation behavior of 266 nm Nd: Y A G and 193 nm ArF excimer laser for LA-ICP-MS analysis
    • Günther D, Heinrich C A. 1999. Comparision of the ablation behavior of 266 nm Nd: Y A G and 193 nm ArF excimer laser for LA-ICP-MS analysis. J. Anal. At. Spectrom., 14: 1369— 1374
    • (1999) J. Anal. At. Spectrom , vol.14 , pp. 1369-1374
    • Günther, D1    Heinrich, C A.2
  • 9
    • 0001651269 scopus 로고    scopus 로고
    • Ultratrace element analysis of NIST S R M 616 and 614 using laser ablation microprobe-inductively coupled plasma mass spectrometry (LAM-ICP-MS): a comparison with secondary ion mass spectrometry (SIMS)
    • Horn I, Hinton R W, Jackson S E, Longerich H P. 1997. Ultratrace element analysis of NIST S R M 616 and 614 using laser ablation microprobe-inductively coupled plasma mass spectrometry (LAM-ICP-MS): a comparison with secondary ion mass spectrometry (SIMS). Geostandards Newsletters, 21: 191— 203
    • (1997) Geostandards Newsletters , vol.21 , pp. 191-203
    • Horn, I1    Hinton, R W2    Jackson, S E3    Longerich, H P.4
  • 10
    • 0030366786 scopus 로고    scopus 로고
    • Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry
    • Longerich H P, Gunther D, Jackson S E. 1996. Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry. Fresenius J. Anal. Chem., 355:538— 542
    • (1996) Fresenius J. Anal. Chem , vol.355 , pp. 538-542
    • Longerich, H P1    Gunther, D2    Jackson, S E.3
  • 11
    • 33749997285 scopus 로고    scopus 로고
    • Quantitative analysis of trace elements in geological materials by laser ablation ICPMS: instrumental operating conditions and calibration values of NIST glasses
    • Norman M D, Pearson N J, Sharma A, Griffin W L. 1996. Quantitative analysis of trace elements in geological materials by laser ablation ICPMS: instrumental operating conditions and calibration values of NIST glasses. Geostandards Newsletter, 20: 247 -261
    • (1996) Geostandards Newsletter , vol.20 , pp. 247-261
    • Norman, M D1    Pearson, N J2    Sharma, A3    Griffin, W L.4
  • 12
    • 0032072961 scopus 로고    scopus 로고
    • Quantitative analysis of trace element abundances in glasses and minerals: a comparison of laser ablation inductively coupled plasma mass spectrometry, solution inductively coupled plasma mass spectrometry, proton microprobe and electron microprobe data
    • Norman M D, Griffin W L, Pearson N J, Garciac M O, O 'Reilly S Y. 1998. Quantitative analysis of trace element abundances in glasses and minerals: a comparison of laser ablation inductively coupled plasma mass spectrometry, solution inductively coupled plasma mass spectrometry, proton microprobe and electron microprobe data. Journal of Analytical Atomic Spectrometry, 13:477-482
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 477-482
    • Norman, M D1    Griffin, W L2    Pearson, N J3    Garciac, M O4    O 'Reilly, S Y.5
  • 13
    • 0000833990 scopus 로고    scopus 로고
    • A compilation of new and published major and trace element data for NIST SRM610 and NIST S R M 612 glass reference materials
    • Pearce N J G, Perkins W T, Westgate J A, Gorton M P, Jackson S E, Neal C R and Chenery S P. 1997. A compilation of new and published major and trace element data for NIST SRM610 and NIST S R M 612 glass reference materials. Geostandards Newsletters, 20: 247— 261
    • (1997) Geostandards Newsletters , vol.20 , pp. 247-261
    • Pearce, N J G1    Perkins, W T2    Westgate, J A3    Gorton, M P4    Jackson, S E5    Neal, C R6    Chenery, S P.7
  • 14
    • 0002880370 scopus 로고    scopus 로고
    • Major and trace element composition and homogeneity of microbeam reference material: Basalt glass USGS BCR-2G
    • Rocholl A. 1998. Major and trace element composition and homogeneity of microbeam reference material: Basalt glass USGS BCR-2G. Geostandards Newsletter, 22: 33— 45
    • (1998) Geostandards Newsletter , vol.22 , pp. 33-45
    • Rocholl, A.1
  • 15
    • 0001185316 scopus 로고    scopus 로고
    • New ID-TIMS, ICP-MS and SIMS data on the trace element composition and homogeneity of NIST certified reference material S R M 610—611
    • Rocholl A, Duski P, Raczek I. 2000. New ID-TIMS, ICP-MS and SIMS data on the trace element composition and homogeneity of NIST certified reference material S R M 610—611. Geostandards Newsletter, 24: 261— 274
    • (2000) Geostandards Newsletter , vol.24 , pp. 261-274
    • Rocholl, A1    Duski, P2    Raczek, I.3
  • 16
    • 0033968735 scopus 로고    scopus 로고
    • Rutilebearing refractory eclogites; Missing link between continents and depleted mantle
    • Rudnick R L, Barth M, Horn I, McDonough W F. 2000. Rutilebearing refractory eclogites; Missing link between continents and depleted mantle. Science, 287: 278— 281
    • (2000) Science , vol.287 , pp. 278-281
    • Rudnick, R L1    Barth, M2    Horn, I3    McDonough, W F.4
  • 17
    • 85178004695 scopus 로고    scopus 로고
    • Compositions and thermobarometry of peridotite xenoliths from the North China craton
    • (in preparation)
    • Rudnick R L, Gao S, McDonough W F. 2002. Compositions and thermobarometry of peridotite xenoliths from the North China craton. Journal of Petrology (in preparation)
    • (2002) Journal of Petrology
    • Rudnick, R L1    Gao, S2    McDonough, W F.3
  • 18
    • 0000062699 scopus 로고    scopus 로고
    • Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects
    • Steven F D. 1999. Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects. J. Anal. At. Spectrom., 14: 1385— 1403
    • (1999) J. Anal. At. Spectrom , vol.14 , pp. 1385-1403
    • Steven, F D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.