메뉴 건너뛰기




Volumn 4, Issue 5, 2017, Pages 168-173

Multi-modal imaging, model-based tracking, and mixed reality visualisation for orthopaedic surgery

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DATA FUSION; IMAGE REGISTRATION; ITERATIVE METHODS; MIXED REALITY; MODAL ANALYSIS; ORTHOPEDICS; SCREWS; THREE DIMENSIONAL COMPUTER GRAPHICS; TRANSPLANTATION (SURGICAL);

EID: 85056225324     PISSN: None     EISSN: 20533713     Source Type: Journal    
DOI: 10.1049/htl.2017.0066     Document Type: Conference Paper
Times cited : (50)

References (24)
  • 1
    • 0031278144 scopus 로고    scopus 로고
    • Percutaneous fluoroscopic screw fixation of acetabular fractures
    • Parker P.J., Copeland C.: 'Percutaneous fluoroscopic screw fixation of acetabular fractures', Injury, 1997, 28, (9), pp. 597-600
    • (1997) Injury , vol.28 , Issue.9 , pp. 597-600
    • Parker, P.J.1    Copeland, C.2
  • 2
    • 0342854153 scopus 로고    scopus 로고
    • Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulum
    • Starr A., Jones A., Reinert C., et al.: 'Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulum', Injury, 2001, 32, pp. 45-50
    • (2001) Injury , vol.32 , pp. 45-50
    • Starr, A.1    Jones, A.2    Reinert, C.3
  • 3
    • 35948991068 scopus 로고    scopus 로고
    • Navigating the fluoro-scope's C-arm back into position: An accurate and practicable solution to cut radiation and optimize intraoperative workflow
    • Matthews F., Hoigne D., Weiser M., et al.: 'Navigating the fluoro-scope's C-arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow', J. Orthop. Trauma, 2007, 21, pp. 687-692
    • (2007) J. Orthop. Trauma , vol.21 , pp. 687-692
    • Matthews, F.1    Hoigne, D.2    Weiser, M.3
  • 5
    • 33644660012 scopus 로고    scopus 로고
    • Fluoroscopic radiation exposure of the kyphoplasty patient
    • Boszczyk B.M., Bierschneider M., Panzer S., et al.: 'Fluoroscopic radiation exposure of the kyphoplasty patient', Eur. Spine J., 2006, 15, (3), pp. 347-355
    • (2006) Eur. Spine J. , vol.15 , Issue.3 , pp. 347-355
    • Boszczyk, B.M.1    Bierschneider, M.2    Panzer, S.3
  • 6
    • 33644904046 scopus 로고    scopus 로고
    • Surgeon's radiation exposure during percutaneous vertebroplasty
    • Synowitz M., Kiwit J.: 'Surgeon's radiation exposure during percutaneous vertebroplasty', J. Neurosurg., Spine, 2006, 4, (2), pp. 106-109
    • (2006) J. Neurosurg., Spine , vol.4 , Issue.2 , pp. 106-109
    • Synowitz, M.1    Kiwit, J.2
  • 7
    • 77954224040 scopus 로고    scopus 로고
    • Camera augmented mobile C-arm (CAMC): Calibration, accuracy study, and clinical applications
    • Navab N, Heining S.M., Traub J.: 'Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications', IEEE Trans. Med. Imaging, 2010, 29, pp. 1412-1423
    • (2010) IEEE Trans. Med. Imaging , vol.29 , pp. 1412-1423
    • Navab, N.1    Heining, S.M.2    Traub, J.3
  • 8
    • 84863505460 scopus 로고    scopus 로고
    • First deployments of augmented reality in operating rooms
    • Navab N, Blum T., Wang L., et al.: 'First deployments of augmented reality in operating rooms', Computer, 2012, 45, pp. 48-55
    • (2012) Computer , vol.45 , pp. 48-55
    • Navab, N.1    Blum, T.2    Wang, L.3
  • 11
    • 84867650904 scopus 로고    scopus 로고
    • An on-board surgical tracking and video augmentation system for C-arm image guidance
    • Reaungamornrat S., Otake Y., Uneri A., et al.: 'An on-board surgical tracking and video augmentation system for C-arm image guidance', Int. J. Comput. Assist. Radiol. Surg., 2012, 7, (5), pp. 647-665
    • (2012) Int. J. Comput. Assist. Radiol. Surg. , vol.7 , Issue.5 , pp. 647-665
    • Reaungamornrat, S.1    Otake, Y.2    Uneri, A.3
  • 12
    • 2942534276 scopus 로고    scopus 로고
    • C-arm based navigation in total hip arthroplasty background and clinical experience
    • Grützner P.A., Zheng G., Langlotz U., et al.: 'C-arm based navigation in total hip arthroplasty background and clinical experience', Injury, 2004, 35, (1), pp. 90-95, supplement
    • (2004) Injury , vol.35 , Issue.1 , pp. 90-95
    • Grützner, P.A.1    Zheng, G.2    Langlotz, U.3
  • 13
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • Siewerdsen J.H., Moseley DJ, Burch S., et al.: 'Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery', Med. Phys., 2005, 32, (1), pp. 241-254
    • (2005) Med. Phys. , vol.32 , Issue.1 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3
  • 15
    • 85019579642 scopus 로고    scopus 로고
    • Pose-aware C-arm for automatic re-initialization of interventional 2d/3d image registration
    • Fotouhi J., Fuerst B., Johnson A., et al.: 'Pose-aware C-arm for automatic re-initialization of interventional 2d/3d image registration', Int. J. Comput. Assist. Radiol. Surg., 2017, 12, (7), pp. 1221-1230
    • (2017) Int. J. Comput. Assist. Radiol. Surg. , vol.12 , Issue.7 , pp. 1221-1230
    • Fotouhi, J.1    Fuerst, B.2    Johnson, A.3
  • 16
    • 85015985237 scopus 로고    scopus 로고
    • Canreal-time RGBD enhance intraoperative cone-beam CT?
    • Fotouhi J., Fuerst B., Wein W., et al.: 'Canreal-time RGBD enhance intraoperative cone-beam CT?', Int. J. Comput. Assist. Radiol. Surg., 2017, 12, (7), pp. 1211-1219
    • (2017) Int. J. Comput. Assist. Radiol. Surg. , vol.12 , Issue.7 , pp. 1211-1219
    • Fotouhi, J.1    Fuerst, B.2    Wein, W.3
  • 17
    • 84964009633 scopus 로고    scopus 로고
    • Calibration of RGBD camera and cone-beam CT for 3d intra-operative mixed reality visualization
    • Lee S.C., Fuerst B., Fotouhi J., et al.: 'Calibration of RGBD camera and cone-beam CT for 3d intra-operative mixed reality visualization', Int. J. Comput. Assist. Radiol. Surg., 2016, 11, (6), pp. 967-975
    • (2016) Int. J. Comput. Assist. Radiol. Surg. , vol.11 , Issue.6 , pp. 967-975
    • Lee, S.C.1    Fuerst, B.2    Fotouhi, J.3
  • 18
    • 84961209289 scopus 로고    scopus 로고
    • Preclinical usability study of multiple augmented reality concepts for k-wire placement
    • Fischer M., Fuerst B., Lee S.C., et al.: 'Preclinical usability study of multiple augmented reality concepts for k-wire placement', Int. J. Comput. Assist. Radiol. Surg., 2016, 11, (6), pp. 1007-1014
    • (2016) Int. J. Comput. Assist. Radiol. Surg. , vol.11 , Issue.6 , pp. 1007-1014
    • Fischer, M.1    Fuerst, B.2    Lee, S.C.3
  • 20
    • 85006414868 scopus 로고    scopus 로고
    • Large scale and long standing simultaneous reconstruction and segmentation
    • Tateno K., Tombari F., Navab N.: 'Large scale and long standing simultaneous reconstruction and segmentation', Comput. Vis. Image Underst., 2017, 157, pp. 138-150
    • (2017) Comput. Vis. Image Underst. , vol.157 , pp. 138-150
    • Tateno, K.1    Tombari, F.2    Navab, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.