Preclinical usability study of multiple augmented reality concepts for K-wire placement

Author keywords

Interventional imaging; Orthopedic and Trauma surgery; Usability study

Indexed keywords

ARTICLE; CLINICAL EVALUATION; CONE BEAM COMPUTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY SCANNER; DIGITAL RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; IMAGING PHANTOM; KIRSCHNER WIRE; MEASUREMENT ACCURACY; ORTHOPEDIC SURGERY; PRIORITY JOURNAL; SURGEON; THREE DIMENSIONAL IMAGING; X RAY ANALYSIS; X RAY CAMERA; BONE WIRE; DIAGNOSTIC IMAGING; FRACTURES, BONE; INJURIES; INTERVENTIONAL RADIOLOGY; OSTEOSYNTHESIS; PELVIC GIRDLE; PROCEDURES; X-RAY COMPUTED TOMOGRAPHY;

EID: 84961209289     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-016-1363-x     Document Type: Article
Times cited : (50)

References (36)
  • 2
    • 0029249334 scopus 로고
    • The retrograde medullary superior public ramus screw for the treatment of anterior pelvic ring disruptions: a new technique
    • PID: 7714652
    • Routt ML Jr, Simonian PT, Grujic L (1995) The retrograde medullary superior public ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma 9(1):35–44
    • (1995) J Orthop Trauma , vol.9 , Issue.1 , pp. 35-44
    • Routt, M.L.1    Simonian, P.T.2    Grujic, L.3
  • 4
    • 0001837148 scopus 로고
    • A comparison of alternative tests of significance for the problem of m rankings
    • Friedman M (1940) A comparison of alternative tests of significance for the problem of m rankings. Ann Math Stat 11(1):86–92
    • (1940) Ann Math Stat , vol.11 , Issue.1 , pp. 86-92
    • Friedman, M.1
  • 5
    • 0026589215 scopus 로고
    • Percutaneous screw fixation of acetabular fractures with ct guidance: preliminary results of a new technique
    • COI: 1:STN:280:DyaK387ovVymtQ%3D%3D, PID: 1546599
    • Gay SB, Sistrom C, Wang GJ, Kahler DA, Boman T, McHugh N, Goitz HT (1992) Percutaneous screw fixation of acetabular fractures with ct guidance: preliminary results of a new technique. AJR Am J Roentgenol 158(4):819–822
    • (1992) AJR Am J Roentgenol , vol.158 , Issue.4 , pp. 819-822
    • Gay, S.B.1    Sistrom, C.2    Wang, G.J.3    Kahler, D.A.4    Boman, T.5    McHugh, N.6    Goitz, H.T.7
  • 6
    • 33748079472 scopus 로고    scopus 로고
    • Does computer-assisted spine surgery reduce intraoperative radiation doses?
    • PID: 16924222
    • Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31(17):2024–2027
    • (2006) Spine , vol.31 , Issue.17 , pp. 2024-2027
    • Gebhard, F.T.1    Kraus, M.D.2    Schneider, E.3    Liener, U.C.4    Kinzl, L.5    Arand, M.6
  • 7
    • 84864367875 scopus 로고    scopus 로고
    • Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study
    • PID: 22357092
    • Gras F, Marintschev I, Klos K, Mückley T, Hofmann GO, Kahler DM (2012) Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study. J Orthop Trauma 26(8):466–473
    • (2012) J Orthop Trauma , vol.26 , Issue.8 , pp. 466-473
    • Gras, F.1    Marintschev, I.2    Klos, K.3    Mückley, T.4    Hofmann, G.O.5    Kahler, D.M.6
  • 8
    • 77951787510 scopus 로고    scopus 로고
    • The “safe zone” for extra-articular screw placement during intra-pelvic acetabular surgery
    • PID: 20418732
    • Guy P, Al-Otaibi M, Harvey EJ, Helmy N (2010) The “safe zone” for extra-articular screw placement during intra-pelvic acetabular surgery. J Orthop Trauma 24(5):279–283
    • (2010) J Orthop Trauma , vol.24 , Issue.5 , pp. 279-283
    • Guy, P.1    Al-Otaibi, M.2    Harvey, E.J.3    Helmy, N.4
  • 9
    • 84962322478 scopus 로고    scopus 로고
    • Navab N (2015) Rgbdx: first design and experimental validation of a mirror-based rgbd x-ray imaging system
    • IEEE, Fukuoka
    • Habert S, Gardiazabal J, Fallavollita P, Navab N (2015) Rgbdx: first design and experimental validation of a mirror-based rgbd x-ray imaging system. In: International symposium on Mixed and Augmented Reality (ISMAR), IEEE, Fukuoka, pp 13–18. doi:10.1109/ISMAR.2015.17
    • International symposium on Mixed and Augmented Reality (ISMAR) , pp. 13-18
    • Habert, S.1    Gardiazabal, J.2    Fallavollita, P.3
  • 13
    • 84885310951 scopus 로고    scopus 로고
    • Integration of fluoroscopy-based guidance in orthopaedic trauma surgery—a prospective cohort study
    • PID: 23507528
    • Kraus M, von dem Berge S, Schöll H, Krischak G, Gebhard F (2013) Integration of fluoroscopy-based guidance in orthopaedic trauma surgery—a prospective cohort study. Injury 44(11):1486–1492
    • (2013) Injury , vol.44 , Issue.11 , pp. 1486-1492
    • Kraus, M.1    von dem Berge, S.2    Schöll, H.3    Krischak, G.4    Gebhard, F.5
  • 14
    • 84986544938 scopus 로고    scopus 로고
    • Computer-aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center
    • PID: 25844281
    • Kraus M, Weiskopf J, Dreyhaupt J, Krischak G, Gebhard F (2015) Computer-aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center. Global Spine J 5(2):93
    • (2015) Global Spine J , vol.5 , Issue.2 , pp. 93
    • Kraus, M.1    Weiskopf, J.2    Dreyhaupt, J.3    Krischak, G.4    Gebhard, F.5
  • 15
    • 84975665361 scopus 로고    scopus 로고
    • Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization. Manuscript submitted for publication
    • Lee SC, Fuerst B, Fotouhi J, Fischer M, Osgood G, Navab N (2016) Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization. Manuscript submitted for publication. Draft attached for reviewers
    • (2016) Draft attached for reviewers
    • Lee, S.C.1    Fuerst, B.2    Fotouhi, J.3    Fischer, M.4    Osgood, G.5    Navab, N.6
  • 17
    • 0033094213 scopus 로고    scopus 로고
    • Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone
    • COI: 1:STN:280:DyaK1M3jsFygug%3D%3D, PID: 10217820
    • Mears DC (1999) Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone. J Am Acad Orthop Surg 7(2):128–141
    • (1999) J Am Acad Orthop Surg , vol.7 , Issue.2 , pp. 128-141
    • Mears, D.C.1
  • 18
    • 84863505460 scopus 로고    scopus 로고
    • First deployments of augmented reality in operating rooms
    • Navab N, Blum T, Wang L, Okur A, Wendler T (2012) First deployments of augmented reality in operating rooms. Computer 7:48–55
    • (2012) Computer , vol.7 , pp. 48-55
    • Navab, N.1    Blum, T.2    Wang, L.3    Okur, A.4    Wendler, T.5
  • 19
    • 77954224040 scopus 로고    scopus 로고
    • Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications
    • PID: 20659830
    • Navab N, Heining SM, Traub J (2010) Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications. IEEE Trans Med Imaging 29(7):1412–1423
    • (2010) IEEE Trans Med Imaging , vol.29 , Issue.7 , pp. 1412-1423
    • Navab, N.1    Heining, S.M.2    Traub, J.3
  • 20
    • 84957077730 scopus 로고    scopus 로고
    • Camera-augmented mobile c-arm (camc) application: 3d reconstruction using a low-cost mobile c-arm. In: Medical Image Computing and Computer-Assisted Intervention–MICCAI99, Springer
    • Navab N, Mitschke M, Schütz O (1999) Camera-augmented mobile c-arm (camc) application: 3d reconstruction using a low-cost mobile c-arm. In: Medical Image Computing and Computer-Assisted Intervention–MICCAI99, Springer, pp 688–697
    • (1999) pp 688–697
    • Navab, N.1    Mitschke, M.2    Schütz, O.3
  • 22
    • 84975628064 scopus 로고    scopus 로고
    • Fusion of C-arm X-ray image on video view to reduce radiation exposure and improve orthopedic surgery planning: first in-vivo evaluation. In: Proceedings of 15th annual conference of the international society for computer aided surgery
    • Nicolau S, Lee P, Wu H, Huang M, Lukang R, Soler L, Marescaux J (2011) Fusion of C-arm X-ray image on video view to reduce radiation exposure and improve orthopedic surgery planning: first in-vivo evaluation. In: Proceedings of 15th annual conference of the international society for computer aided surgery. Computer assisted radiology and surgery
    • (2011) Computer assisted radiology and surgery
    • Nicolau, S.1    Lee, P.2    Wu, H.3    Huang, M.4    Lukang, R.5    Soler, L.6    Marescaux, J.7
  • 23
    • 84894384066 scopus 로고    scopus 로고
    • Statistical errors
    • COI: 1:CAS:528:DC%2BC2cXisVanurY%3D, PID: 24522584
    • Nuzzo R (2014) Statistical errors. Nature 506(7487):150–152
    • (2014) Nature , vol.506 , Issue.7487 , pp. 150-152
    • Nuzzo, R.1
  • 26
    • 0343239081 scopus 로고    scopus 로고
    • Percutaneous fixation of pelvic ring disruptions
    • PID: 10853150
    • Routt MC Jr, Nork SE, Mills WJ (2000) Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res 375:15–29
    • (2000) Clin Orthop Relat Res , vol.375 , pp. 15-29
    • Routt, M.C.1    Nork, S.E.2    Mills, W.J.3
  • 27
    • 0031266643 scopus 로고    scopus 로고
    • Iliosacral screw fixation: early complications of the percutaneous technique
    • PID: 9415865
    • Routt MC Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589
    • (1997) J Orthop Trauma , vol.11 , Issue.8 , pp. 584-589
    • Routt, M.C.1    Simonian, P.T.2    Mills, W.J.3
  • 28
    • 47549108427 scopus 로고    scopus 로고
    • Closed reduction and iliosacral percutaneous fixation of unstable pelvic ring fractures
    • PID: 18621370
    • Schweitzer D, Zylberberg A, Córdova M, Gonzalez J (2008) Closed reduction and iliosacral percutaneous fixation of unstable pelvic ring fractures. Injury 39(8):869–874
    • (2008) Injury , vol.39 , Issue.8 , pp. 869-874
    • Schweitzer, D.1    Zylberberg, A.2    Córdova, M.3    Gonzalez, J.4
  • 29
    • 0342854153 scopus 로고    scopus 로고
    • Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulum
    • Starr A, Jones A, Reinert C, Borer D (2001) Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulum. Injury 32:45–50
    • (2001) Injury , vol.32 , pp. 45-50
    • Starr, A.1    Jones, A.2    Reinert, C.3    Borer, D.4
  • 30
    • 0031611421 scopus 로고    scopus 로고
    • Percutaneous fixation of the columns of the acetabulum: a new technique
    • COI: 1:STN:280:DyaK1c7gvVOrsg%3D%3D, PID: 9447519
    • Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12(1):51–58
    • (1998) J Orthop Trauma , vol.12 , Issue.1 , pp. 51-58
    • Starr, A.J.1    Reinert, C.M.2    Jones, A.L.3
  • 31
    • 34247136630 scopus 로고    scopus 로고
    • Image guidance in pelvic and acetabular surgery—expectations, success and limitations
    • Stöckle U, Schaser K, König B (2007) Image guidance in pelvic and acetabular surgery—expectations, success and limitations. Injury 38(4):450–462. doi:10.1016/j.injury.2007.01.024
    • (2007) Injury , vol.38 , Issue.4 , pp. 450-462
    • Stöckle, U.1    Schaser, K.2    König, B.3
  • 32
    • 33644904046 scopus 로고    scopus 로고
    • Surgeon’s radiation exposure during percutaneous vertebroplasty
    • PID: 16506476
    • Synowitz M, Kiwit J (2006) Surgeon’s radiation exposure during percutaneous vertebroplasty. J Neurosurg Spine 4(2):106–109
    • (2006) J Neurosurg Spine , vol.4 , Issue.2 , pp. 106-109
    • Synowitz, M.1    Kiwit, J.2
  • 33
    • 79551680933 scopus 로고    scopus 로고
    • A multi-view opto-Xray imaging system. In: Medical Image Computing and Computer-Assisted Intervention–MICCAI 2007, Springer
    • Traub J, Heibel TH, Dressel P, Heining SM, Graumann R, Navab N (2007) A multi-view opto-Xray imaging system. In: Medical Image Computing and Computer-Assisted Intervention–MICCAI 2007, Springer, pp 18–25
    • (2007) pp 18–25
    • Traub, J.1    Heibel, T.H.2    Dressel, P.3    Heining, S.M.4    Graumann, R.5    Navab, N.6
  • 34
    • 0023397578 scopus 로고
    • A versatile camera calibration technique for high-accuracy 3d machine vision metrology using off-the-shelf tv cameras and lenses
    • Tsai RY (1987) A versatile camera calibration technique for high-accuracy 3d machine vision metrology using off-the-shelf tv cameras and lenses. IEEE J Robot Autom 3(4):323–344
    • (1987) IEEE J Robot Autom , vol.3 , Issue.4 , pp. 323-344
    • Tsai, R.Y.1
  • 35
    • 0001884644 scopus 로고
    • Individual comparisons by ranking methods
    • Wilcoxon F (1945) Individual comparisons by ranking methods. Biometrics Bull 1(6):80–83
    • (1945) Biometrics Bull , vol.1 , Issue.6 , pp. 80-83
    • Wilcoxon, F.1
  • 36
    • 80052273854 scopus 로고    scopus 로고
    • Development and validation of a surgical workload measure: the surgery task load index (surg-tlx)
    • PID: 21597890
    • Wilson MR, Poolton JM, Malhotra N, Ngo K, Bright E, Masters RS (2011) Development and validation of a surgical workload measure: the surgery task load index (surg-tlx). World J Surg 35(9):1961–1969
    • (2011) World J Surg , vol.35 , Issue.9 , pp. 1961-1969
    • Wilson, M.R.1    Poolton, J.M.2    Malhotra, N.3    Ngo, K.4    Bright, E.5    Masters, R.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.