Volumn 44, Issue 12, 2018, Pages 2213-2215

Non-invasive arterial pressure monitoring revisited

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; ARTERY WALL; ARTICLE; BLOOD PRESSURE MONITORING; CRITICALLY ILL PATIENT; DIASTOLIC BLOOD PRESSURE; DIGITAL ARTERY; HUMAN; HYPERTENSIVE PATIENT; MEAN ARTERIAL PRESSURE; NON INVASIVE MEASUREMENT; PULSE WAVE; PULSE WAVE TRANSIT TIME; TONOMETRY; VALIDATION PROCESS; BLOOD PRESSURE MEASUREMENT; DEVICES; INTENSIVE CARE; PROCEDURES;

EID: 85042919786     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-018-5108-x     Document Type: Article
Times cited : (26)

References (17)
  • 1
    • 84948720097 scopus 로고    scopus 로고
    • The accuracy of the CNAP device compared with invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: a method-comparison study
    • Smolle KH, Schmid M, Prettenthaler H, Weger C (2015) The accuracy of the CNAP device compared with invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: a method-comparison study. Anesth Analg 121:1508–1516
    • (2015) Anesth Analg , vol.121 , pp. 1508-1516
    • Smolle, K.H.1    Schmid, M.2    Prettenthaler, H.3    Weger, C.4
  • 2
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with Nexfin
    • COI: 1:CAS:528:DC%2BC38Xmt1Ghur8%3D
    • Martina JR, Westerhof BE, van Goudoever J et al (2012) Noninvasive continuous arterial blood pressure monitoring with Nexfin. Anesthesiology 116:1092–1103
    • (2012) Anesthesiology , vol.116 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    van Goudoever, J.3
  • 3
    • 84969802049 scopus 로고    scopus 로고
    • Blood pressure monitoring for the anesthesiologist: a practical review
    • COI: 1:CAS:528:DC%2BC28XotF2htb0%3D
    • Bartels K, Esper SA, Thiele RH (2016) Blood pressure monitoring for the anesthesiologist: a practical review. Anesthesiology 122:1866–1879
    • (2016) Anesthesiology , vol.122 , pp. 1866-1879
    • Bartels, K.1    Esper, S.A.2    Thiele, R.H.3
  • 4
    • 84903974142 scopus 로고    scopus 로고
    • Use of the Nexfin device to detect acute arterial pressure variations during anaesthesia induction
    • COI: 1:STN:280:DC%2BC2cnntFOlsQ%3D%3D
    • Weiss E, Gayat E, Duman-Nizard V, Le Guen M, Fischler M (2014) Use of the Nexfin device to detect acute arterial pressure variations during anaesthesia induction. Br J Anaesth 113:52–60
    • (2014) Br J Anaesth , vol.113 , pp. 52-60
    • Weiss, E.1    Gayat, E.2    Duman-Nizard, V.3    Le Guen, M.4    Fischler, M.5
  • 5
    • 84899489146 scopus 로고    scopus 로고
    • Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis
    • Kim SH, Lilot M, Sidhu KS et al (2014) Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology 120:1080–1097
    • (2014) Anesthesiology , vol.120 , pp. 1080-1097
    • Kim, S.H.1    Lilot, M.2    Sidhu, K.S.3
  • 6
    • 85015853219 scopus 로고    scopus 로고
    • Continuous non-invasive finger cuff CareTaker comparable to invasive intra-arteiral pressure in patients undergoing major intra-abdominal surgery
    • Gratz I, Deal E, Spitz F et al (2017) Continuous non-invasive finger cuff CareTaker comparable to invasive intra-arteiral pressure in patients undergoing major intra-abdominal surgery. BMC Anesthesiol 17:48
    • (2017) BMC Anesthesiol , vol.17 , pp. 48
    • Gratz, I.1    Deal, E.2    Spitz, F.3
  • 7
    • 84863085965 scopus 로고    scopus 로고
    • Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    • Dueck R, Goedje O, Clopton P (2012) Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry. J Clin Monit Comput 26:75–83
    • (2012) J Clin Monit Comput , vol.26 , pp. 75-83
    • Dueck, R.1    Goedje, O.2    Clopton, P.3
  • 8
    • 84880550339 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device
    • COI: 1:CAS:528:DC%2BC3sXhtFOgsbjN
    • Saugel B, Meidert AS, Hapfelmeier A et al (2013) Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Br J Anaesth 111:185–190
    • (2013) Br J Anaesth , vol.111 , pp. 185-190
    • Saugel, B.1    Meidert, A.S.2    Hapfelmeier, A.3
  • 9
    • 85030539712 scopus 로고    scopus 로고
    • A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry
    • (epub ahead of print
    • Foldi S, Horvath T, Zieger F et al (2017) A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry. J Clin Monit Comput. 10.1007/s10877-017-0070-7 (epub ahead of print)
    • (2017) J Clin Monit Comput
    • Foldi, S.1    Horvath, T.2    Zieger, F.3
  • 10
    • 84942109475 scopus 로고    scopus 로고
    • Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    • Bilo G, Zorzi C, Ochoa Munera JE et al (2015) Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 20:291–294
    • (2015) Blood Press Monit , vol.20 , pp. 291-294
    • Bilo, G.1    Zorzi, C.2    Ochoa Munera, J.E.3
  • 11
    • 85048521171 scopus 로고    scopus 로고
    • Continuous monitoring of vital signs using wearable devices on the general ward: pilot study
    • Weenk M, van Goor H, Frietman B et al (2017) Continuous monitoring of vital signs using wearable devices on the general ward: pilot study. JMIR Mhealth Uhealth 5:e91
    • (2017) JMIR Mhealth Uhealth , vol.5
    • Weenk, M.1    van Goor, H.2    Frietman, B.3
  • 12
    • 85047268872 scopus 로고    scopus 로고
    • Period-dependent associations between hypotension during and for 4 days after noncardiac surgery and a composite of myocardial infarction and death: a substudy of the POISE-2 trial
    • (epub ahead of print
    • Sessler DI, Meyhoff CS, Zimmerman NM et al (2017) Period-dependent associations between hypotension during and for 4 days after noncardiac surgery and a composite of myocardial infarction and death: a substudy of the POISE-2 trial. Anesthesiology. 10.1097/aln.0000000000001985 (epub ahead of print)
    • (2017) Anesthesiology
    • Sessler, D.I.1    Meyhoff, C.S.2    Zimmerman, N.M.3
  • 13
    • 85051810305 scopus 로고    scopus 로고
    • Error grid analysis for arterial pressure method comparison studies
    • (epub ahead of print
    • Saugel B, Grothe O, Nicklas JY (2017) Error grid analysis for arterial pressure method comparison studies. Anesth Analg. 10.1213/ane.0000000000002585 (epub ahead of print)
    • (2017) Anesth Analg
    • Saugel, B.1    Grothe, O.2    Nicklas, J.Y.3
  • 14
    • 84907362165 scopus 로고    scopus 로고
    • Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring
    • COI: 1:CAS:528:DC%2BC2cXitVWgsLjP
    • Dagdeviren C, Su Y, Joe P et al (2014) Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring. Nat Commun 5:4496
    • (2014) Nat Commun , vol.5 , pp. 4496
    • Dagdeviren, C.1    Su, Y.2    Joe, P.3
  • 15
    • 84958818159 scopus 로고    scopus 로고
    • Monitoring of vital signs with flexible and wearable medical devices
    • COI: 1:CAS:528:DC%2BC28XisVejtL0%3D
    • Khan Y, Ostfeld AE, Lochner CM et al (2016) Monitoring of vital signs with flexible and wearable medical devices. Adv Mater 28:4373–4395
    • (2016) Adv Mater , vol.28 , pp. 4373-4395
    • Khan, Y.1    Ostfeld, A.E.2    Lochner, C.M.3
  • 16
    • 85002853016 scopus 로고    scopus 로고
    • Sensitive electromechanical sensors using viscoelastic graphene-polymer nanocomposites
    • COI: 1:CAS:528:DC%2BC28XitVSrs7jM
    • Boland CS, Khan U, Ryan G et al (2016) Sensitive electromechanical sensors using viscoelastic graphene-polymer nanocomposites. Science 354:1257–1260
    • (2016) Science , vol.354 , pp. 1257-1260
    • Boland, C.S.1    Khan, U.2    Ryan, G.3
  • 17
    • 85026668178 scopus 로고    scopus 로고
    • Digital innovations and emerging technologies for enhanced recovery programmes
    • COI: 1:STN:280:DC%2BC1cnnsVSktw%3D%3D
    • Michard F, Gan TJ, Kehlet H (2017) Digital innovations and emerging technologies for enhanced recovery programmes. Br J Anaesth 119:31–39
    • (2017) Br J Anaesth , vol.119 , pp. 31-39
    • Michard, F.1    Gan, T.J.2    Kehlet, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.