메뉴 건너뛰기




Volumn 5, Issue , 2014, Pages

Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring

Author keywords

[No Author keywords available]

Indexed keywords

ELASTOMER; SILICONE; TITANIUM DERIVATIVE; UNCLASSIFIED DRUG; ZIRCONATE TITANATE; ZIRCONIUM DERIVATIVE; LEAD; LEAD TITANATE ZIRCONATE; SILICON; TITANIUM; ZIRCONIUM;

EID: 84907362165     PISSN: None     EISSN: 20411723     Source Type: Journal    
DOI: 10.1038/ncomms5496     Document Type: Article
Times cited : (774)

References (47)
  • 1
    • 80755189431 scopus 로고    scopus 로고
    • Thiocyanate-capped PbS nanocubes: Ambipolar transport enables quantum dot based circuits on a flexible substrate
    • Koh, W., Saudari, S. R., Fafarman, A. T., Kagan, C. R. & Murray, C. B. Thiocyanate-capped PbS nanocubes: Ambipolar transport enables quantum dot based circuits on a flexible substrate. Nano Lett. 11, 4764-4767 (2011
    • (2011) Nano Lett. , vol.11 , pp. 4764-4767
    • Koh, W.1    Saudari, S.R.2    Fafarman, A.T.3    Kagan, C.R.4    Murray, C.B.5
  • 2
    • 84879227608 scopus 로고    scopus 로고
    • Magnet-in-thesemiconductor nanomaterials: High electron mobility in all-inorganic arrays of FePt/CdSe and FePt/CdS core-shell heterostructures
    • Son, J. S., Lee, J. S., Shevchenko, E. V. & Talapin, D. V. Magnet-in-thesemiconductor nanomaterials: High electron mobility in all-inorganic arrays of FePt/CdSe and FePt/CdS core-shell heterostructures. J. Phys. Chem. Lett. 4, 1918-1923 (2013
    • (2013) J. Phys. Chem. Lett. , vol.4 , pp. 1918-1923
    • Son, J.S.1    Lee, J.S.2    Shevchenko, E.V.3    Talapin, D.V.4
  • 3
    • 84879688165 scopus 로고    scopus 로고
    • Surface modification of inorganic nanoparticles for development of organic-inorganic nanocomposites-A review
    • Kango, S. et al. Surface modification of inorganic nanoparticles for development of organic-inorganic nanocomposites-A review. Prog. Polym. Sci. 38, 1232-1261 (2013
    • (2013) Prog. Polym. Sci. , vol.38 , pp. 1232-1261
    • Kango, S.1
  • 4
    • 84877283007 scopus 로고    scopus 로고
    • Nanowire nanoelectronics: Building interfaces with tissue and cells at the natural scale of biology
    • Cohen-Karni, T. & Lieber, C. M. Nanowire nanoelectronics: Building interfaces with tissue and cells at the natural scale of biology. Pure Appl. Chem. 85, 883-901 (2013
    • (2013) Pure Appl. Chem. , vol.85 , pp. 883-901
    • Cohen-Karni, T.1    Lieber, C.M.2
  • 5
    • 0037448573 scopus 로고    scopus 로고
    • Single-nanowire electrically drive lasers
    • Duan, X., Huang, Y., Agarwal, R. & Lieber, C. M. Single-nanowire electrically drive lasers. Nature 421, 241-245 (2001
    • (2001) Nature , vol.421 , pp. 241-245
    • Duan, X.1    Huang, Y.2    Agarwal, R.3    Lieber, C.M.4
  • 7
    • 80052413216 scopus 로고    scopus 로고
    • Synthesis assembly and applications of semiconductor nanomembranes
    • Rogers, J. A., Lagally, M. G. & Nuzzo, R. G. Synthesis, assembly and applications of semiconductor nanomembranes. Nature 477, 45-53 (2011
    • (2011) Nature , vol.477 , pp. 45-53
    • Rogers, J.A.1    Lagally, M.G.2    Nuzzo, R.G.3
  • 8
    • 77950214388 scopus 로고    scopus 로고
    • Materials and mechanics for stretchable electronics
    • Rogers, J. A., Someya, T. & Huang, Y. Materials and mechanics for stretchable electronics. Science 327, 1603-1607 (2010
    • (2010) Science , vol.327 , pp. 1603-1607
    • Rogers, J.A.1    Someya, T.2    Huang, Y.3
  • 10
    • 84878534867 scopus 로고    scopus 로고
    • Micromachined ultrasonic transducers based on lead zirconate titanate (PZT) films
    • Li, J., Wang, C., Ma, J. & Liu, M. Micromachined ultrasonic transducers based on lead zirconate titanate (PZT) films. Microsyst. Technol. 19, 211-218 (2013
    • (2013) Microsyst. Technol. , vol.19 , pp. 211-218
    • Li, J.1    Wang, C.2    Ma, J.3    Liu, M.4
  • 12
    • 58149485447 scopus 로고    scopus 로고
    • Feasibility study of a thick-film PZT resonant pressure sensor made on a prefired 3D LTCC structure
    • Zarnik, M. S., Belavic?, D., Mac?ek, S. & Holc, J. Feasibility study of a thick-film PZT resonant pressure sensor made on a prefired 3D LTCC structure. Int. J. Appl. Ceram. Technol. 6, 9-17 (2009
    • (2009) Int. J. Appl. Ceram. Technol. , vol.6 , pp. 9-17
    • Zarnik, M.S.1    Belavic, D.2    Macek, S.3    Holc, J.4
  • 13
    • 78149264286 scopus 로고    scopus 로고
    • Fabrication and testing of a PZT strain sensor for soil applications
    • Soman, J. & O'Neal, C. B. Fabrication and testing of a PZT strain sensor for soil applications. IEEE Sens. J. 11, 78-85 (2011
    • (2011) IEEE Sens. J. , vol.11 , pp. 78-85
    • Soman, J.1    O'Neal, C.B.2
  • 14
    • 0000195589 scopus 로고    scopus 로고
    • Ferroelectric dielectric and piezoelectric properties of ferroelectric thin films and ceramics
    • Damjanovic, D. Ferroelectric, dielectric and piezoelectric properties of ferroelectric thin films and ceramics. Rep. Prog. Phys. 61, 1267-1324 (1998
    • (1998) Rep. Prog. Phys. , vol.61 , pp. 1267-1324
    • Damjanovic, D.1
  • 15
    • 84866103813 scopus 로고    scopus 로고
    • Piezoelectric nanoribbons for monitoring cellular deformations
    • Nguyen, T. D. et al. Piezoelectric nanoribbons for monitoring cellular deformations. Nat. Nanotech. 7, 587-593 (2012
    • (2012) Nat. Nanotech. , vol.7 , pp. 587-593
    • Nguyen, T.D.1
  • 16
    • 84893477161 scopus 로고    scopus 로고
    • Conformal, multilayer piezoelectric energy harvesting and storage from motions of the heart, lung and diaphragm
    • Dagdeviren, C. et al. Conformal, multilayer piezoelectric energy harvesting and storage from motions of the heart, lung and diaphragm. Proc. Natl Acad. Sci. USA 111, 1927-1932 (2014
    • (2014) Proc. Natl Acad. Sci. USA , vol.111 , pp. 1927-1932
    • Dagdeviren, C.1
  • 17
    • 84861832877 scopus 로고    scopus 로고
    • Flexible nanocomposite generator made of BaTiO3 nanoparticles and graphitic carbons
    • Park, K. I. et al. Flexible nanocomposite generator made of BaTiO3 nanoparticles and graphitic carbons. Adv. Mater. 24, 2999-3004 (2012
    • (2012) Adv. Mater. , vol.24 , pp. 2999-3004
    • Park, K.I.1
  • 18
    • 84885970958 scopus 로고    scopus 로고
    • Transient, biocompatible electronics and energy harvesters based on ZnO
    • Dagdeviren, C. et al. Transient, biocompatible electronics and energy harvesters based on ZnO. Small 9, 3398-3404 (2013
    • (2013) Small , vol.9 , pp. 3398-3404
    • Dagdeviren, C.1
  • 19
    • 80955144235 scopus 로고    scopus 로고
    • One-dimensional ZnO nanostructures: Solution growth and functional properties
    • Xu, S. & Wang, Z. L. One-dimensional ZnO nanostructures: Solution growth and functional properties. Nano Res. 4, 1013-1098 (2011
    • (2011) Nano Res. , vol.4 , pp. 1013-1098
    • Xu, S.1    Wang, Z.L.2
  • 20
    • 75449092277 scopus 로고    scopus 로고
    • Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment
    • Avolio, A. P., Butlin, M. & Walsh, A. Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment. Physiol. Meas. 31, R1-R47 (2010
    • (2010) Physiol. Meas. , vol.31 , pp. 1-47
    • Avolio, A.P.1    Butlin, M.2    Walsh, A.3
  • 21
    • 77951721505 scopus 로고    scopus 로고
    • Noninvasive measurement of central vascular pressures with arterial tonometry: Clinical revival of the pulse pressure waveform?
    • Nelson, M. R. et al. Noninvasive measurement of central vascular pressures with arterial tonometry: Clinical revival of the pulse pressure waveform? Mayo Clin. Proc. 85, 460-472 (2010
    • (2010) Mayo Clin. Proc. , vol.85 , pp. 460-472
    • Nelson, M.R.1
  • 24
    • 33747487059 scopus 로고    scopus 로고
    • Flexible ferroelectret field-effect transistor for large-area sensor skins and microphones
    • Graz, I. et al. Flexible ferroelectret field-effect transistor for large-area sensor skins and microphones. Appl. Phys. Lett. 89, 073501 (2006
    • (2006) Appl. Phys. Lett. , vol.89 , pp. 073501
    • Graz, I.1
  • 28
    • 84878731954 scopus 로고    scopus 로고
    • Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring
    • Schwartz, G. et al. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring. Nat. Commun. 4, 1859 (2013
    • (2013) Nat. Commun. , vol.4 , pp. 1859
    • Schwartz, G.1
  • 29
    • 84875880834 scopus 로고    scopus 로고
    • High performance piezoelectric devices based on aligned arrays of nanofibers of poly(vinyldenefluoride-co-trifluoroethylene
    • Persano, L. et al. High performance piezoelectric devices based on aligned arrays of nanofibers of poly(vinyldenefluoride-co-trifluoroethylene). Nat. Commun. 4, 1633 (2013
    • (2013) Nat. Commun. , vol.4 , pp. 1633
    • Persano, L.1
  • 30
    • 77957132246 scopus 로고    scopus 로고
    • Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
    • Takei, K. et al. Nanowire active-matrix circuitry for low-voltage macroscale artificial skin. Nat. Mater. 9, 821-826 (2010
    • (2010) Nat. Mater. , vol.9 , pp. 821-826
    • Takei, K.1
  • 31
    • 83555165175 scopus 로고    scopus 로고
    • Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
    • Lipomi, D. J. et al. Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes. Nat. Nanotech. 6, 788-792 (2011
    • (2011) Nat. Nanotech. , vol.6 , pp. 788-792
    • Lipomi, D.J.1
  • 32
    • 84862289254 scopus 로고    scopus 로고
    • Transparent triboelectric nanogenerators and self-powered pressure sensors based on micropatterned plastic films
    • Fan, F. R. et al. Transparent triboelectric nanogenerators and self-powered pressure sensors based on micropatterned plastic films. Nano. Lett. 12, 3109-3114 (2012
    • (2012) Nano. Lett. , vol.12 , pp. 3109-3114
    • Fan, F.R.1
  • 33
    • 77957125682 scopus 로고    scopus 로고
    • Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
    • Mannsfeld, S. C. B. et al. Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nat. Mater. 9, 859-864(2010
    • (2010) Nat. Mater. , vol.9 , pp. 859-864
    • Mannsfeld, S.C.B.1
  • 34
    • 80054812483 scopus 로고    scopus 로고
    • Dassault Systèmes Dassault Systèmes Simulia Corp.
    • Dassault Systèmes. Abaqus Analysis User's Manual V.6.10 (Dassault Systèmes Simulia Corp., 2010
    • (2010) Abaqus Analysis User's Manual V.6.10
  • 36
    • 0030052319 scopus 로고    scopus 로고
    • Validation of carotid artery tonometry as a means of estimating augmentation index of ascending aortic pressure
    • Chen, C. H. et al. Validation of carotid artery tonometry as a means of estimating augmentation index of ascending aortic pressure. Hypertension 27, 168-175 (1996
    • (1996) Hypertension , vol.27 , pp. 168-175
    • Chen, C.H.1
  • 37
    • 15744372765 scopus 로고    scopus 로고
    • Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
    • Nichols, W. Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. Am. J. Hypertens 18, 3S-10S (2005
    • (2005) Am. J. Hypertens , vol.18 , pp. 3-10
    • Nichols, W.1
  • 38
    • 0037658999 scopus 로고    scopus 로고
    • Pressure wave reflection assessed from the peripheral pulse: Is a transfer function necessary?
    • DOI 10.1161/01.HYP.0000057574.64076.A5
    • Millasseau, S. C., Patel, S. J., Redwood, S. R., Ritter, J. M. & Chowienczyk, P. J. Pressure wave reflection assessed from the peripheral pulse: Is a transfer function necessary? Hypertension 41, 1016-1020 (2003 (Pubitemid 36548597)
    • (2003) Hypertension , vol.41 , Issue.5 , pp. 1016-1020
    • Millasseau, S.C.1    Patel, S.J.2    Redwood, S.R.3    Ritter, J.M.4    Chowienczyk, P.J.5
  • 39
    • 0035724737 scopus 로고    scopus 로고
    • Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform
    • Pauca, A. L., O'Rourke, M. F. & Kon, N. D. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension 38, 932-937 (2001 (Pubitemid 34258696)
    • (2001) Hypertension , vol.38 , Issue.4 , pp. 932-937
    • Pauca, A.L.1    O'Rourke, M.F.2    Kon, N.D.3
  • 40
    • 76549136619 scopus 로고    scopus 로고
    • Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction
    • Denardo, S. J., Nandyala, R., Freeman, G. L., Pierce, G. L. & Nichols, W. Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction. Circulation 3, 149-156 (2010
    • (2010) Circulation , vol.3 , pp. 149-156
    • Denardo, S.J.1    Nandyala, R.2    Freeman, G.L.3    Pierce, G.L.4    Nichols, W.5
  • 41
    • 15744390757 scopus 로고    scopus 로고
    • Radial augmentation index: A useful and easily obtainable parameter for vascular aging
    • Miki, T. et al. Radial Augmentation Index: A useful and easily obtainable parameter for vascular aging. Am. J. Hypertens. 18, 11-14 (2005
    • (2005) Am. J. Hypertens. , vol.18 , pp. 11-14
    • Miki, T.1
  • 42
    • 38149008070 scopus 로고    scopus 로고
    • Increased arterial stiffness and indication of endothelial dysfunction in long-standing rheumatoid arthritis
    • Klintland, N. et al. Increased arterial stiffness and indication of endothelial dysfunction in long-standing rheumatoid arthritis. Scand. J. Rheumatol. 37, 1-5 (2008
    • (2008) Scand. J. Rheumatol. , vol.37 , pp. 1-5
    • Klintland, N.1
  • 43
    • 58449094904 scopus 로고    scopus 로고
    • Arterial stiffness and ventricular stiffness: A couple of diseases or a coupling disease? A review from the cardiologist's point of view
    • Antonini-Canterin, F. et al. Arterial stiffness and ventricular stiffness: A couple of diseases or a coupling disease? A review from the cardiologist's point of view. Eur. J. Echocardiogr. 10, 36-43 (2009
    • (2009) Eur. J. Echocardiogr. , vol.10 , pp. 36-43
    • Antonini-Canterin, F.1
  • 45
    • 38749124791 scopus 로고    scopus 로고
    • Vascular stiffness: Its measurement and significance for epidemiologic and outcome studies
    • DeLoach, S. S. & Townsend, R. R. Vascular stiffness: Its measurement and significance for epidemiologic and outcome studies. Clin. J. Am. Soc. Nephrol. 3, 184-192 (2008
    • (2008) Clin. J. Am. Soc. Nephrol. , vol.3 , pp. 184-192
    • Deloach, S.S.1    Townsend, R.R.2
  • 46
    • 84877941226 scopus 로고    scopus 로고
    • Multifunctional epidermal electronics printed directly onto the skin
    • Yeo, W.-H. et al. Multifunctional epidermal electronics printed directly onto the skin. Adv. Mater. 25, 2773-2778 (2013
    • (2013) Adv. Mater. , vol.25 , pp. 2773-2778
    • Yeo, W.-H.1
  • 47
    • 84888333877 scopus 로고    scopus 로고
    • Effect of annealing process on properties of Pb (Zr0.52 Ti0.48) O3 thin films prepared by sol-gel method
    • Li, J., Wang, C., Liu, M. & Ma, J. Effect of annealing process on properties of Pb (Zr0.52 Ti0.48) O3 thin films prepared by sol-gel method. Ferroelectrics 445, 32-38 (2013).
    • (2013) Ferroelectrics , vol.445 , pp. 32-38
    • Li, J.1    Wang, C.2    Liu, M.3    Ma, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.