메뉴 건너뛰기




Volumn 56, Issue 5, 2018, Pages 776-788

Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers

Author keywords

analytical verification; hemolysis; icteria; interference; lipemia; preanalytical phase; serum indices

Indexed keywords

ARTICLE; ASSESSMENT OF HUMANS; BLOOD BIOCHEMISTRY; BLOOD SAMPLING; CLINICAL CHEMISTRY; CONTROLLED STUDY; CROSS REACTION; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DILUTION; HEMOLYSIS; HUMAN; HYPERLIPIDEMIA; MAJOR CLINICAL STUDY; MEASUREMENT; PREDICTIVE VALUE; PRIORITY JOURNAL; REFERENCE VALUE; SERUM; THEORETICAL SAMPLE; BLOOD; BLOOD ANALYSIS; COMPARATIVE STUDY; HEALTH CARE QUALITY;

EID: 85040904744     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2017-0889     Document Type: Article
Times cited : (44)

References (31)
  • 1
    • 85007504676 scopus 로고    scopus 로고
    • Current methods of haemolysis detection and reporting as a source of risk to patient safety: A narrative review
    • McCaughey EJ, Vecellio E, Lake R, Li L, Burnett L, Chesher D, et al. Current methods of haemolysis detection and reporting as a source of risk to patient safety: a narrative review. Clin Biochem Rev 2016;37:143-51.
    • (2016) Clin Biochem Rev , vol.37 , pp. 143-151
    • McCaughey, E.J.1    Vecellio, E.2    Lake, R.3    Li, L.4    Burnett, L.5    Chesher, D.6
  • 2
    • 73349087188 scopus 로고    scopus 로고
    • Comparison of visual versus automated detection of lipemic, icteric and hemolyzed specimens: Can we rely on a human eye?
    • Simundic AM, Nikolac N, Ivankovic V, Ferenec-Ruzic D, Magdic B, Kvaternik M, et al. Comparison of visual versus automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye? Clin Chem Lab Med 2009;47:1361-5.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 1361-1365
    • Simundic, A.M.1    Nikolac, N.2    Ivankovic, V.3    Ferenec-Ruzic, D.4    Magdic, B.5    Kvaternik, M.6
  • 3
    • 84945457358 scopus 로고    scopus 로고
    • Systematic assessment of the hemolysis index: Pros and cons
    • Lippi G. Systematic assessment of the hemolysis index: pros and cons. Adv Clin Chem 2015;71:157-70.
    • (2015) Adv Clin Chem , vol.71 , pp. 157-170
    • Lippi, G.1
  • 4
    • 84983260740 scopus 로고    scopus 로고
    • Serum indices: Managing assay interference
    • Farrell CJ, Carter AC. Serum indices: managing assay interference. Ann Clin Biochem 2016;53(Pt 5):527-38.
    • (2016) Ann Clin Biochem , vol.53 , pp. 527-538
    • Farrell, C.J.1    Carter, A.C.2
  • 5
    • 84878332967 scopus 로고    scopus 로고
    • Continuous-flow automation and hemolysis index: A crucial combination
    • Lippi G, Plebani M. Continuous-flow automation and hemolysis index: a crucial combination. J Lab Autom 2013;18:184-8.
    • (2013) J Lab Autom , vol.18 , pp. 184-188
    • Lippi, G.1    Plebani, M.2
  • 6
    • 84882861196 scopus 로고    scopus 로고
    • Systematical assessment of serum indices does not impair efficiency of clinical chemistry testing: A multicenter study
    • Lippi G, Avanzini P, Campioli D, Da Rin G, Dipalo M, Aloe R, et al. Systematical assessment of serum indices does not impair efficiency of clinical chemistry testing: a multicenter study. Clin Biochem 2013;46:1281-4.
    • (2013) Clin Biochem , vol.46 , pp. 1281-1284
    • Lippi, G.1    Avanzini, P.2    Campioli, D.3    Da-Rin, G.4    Dipalo, M.5    Aloe, R.6
  • 8
    • 84901587186 scopus 로고    scopus 로고
    • Harmonization of automated hemolysis index assessment and use: Is it possible?
    • Dolci A, Panteghini M. Harmonization of automated hemolysis index assessment and use: is it possible? Clin Chim Acta 2014;432:38-43.
    • (2014) Clin Chim Acta , vol.432 , pp. 38-43
    • Dolci, A.1    Panteghini, M.2
  • 10
    • 84938723672 scopus 로고    scopus 로고
    • Developing optimized automated rule sets for reporting hemolysis, icterus and lipemia based on a priori outcomes analysis
    • Boyd JM, Krause R, Waite G, Hui W, Yazdi E, Wilmink D, et al. Developing optimized automated rule sets for reporting hemolysis, icterus and lipemia based on a priori outcomes analysis. Clin Chim Acta 2015;450:31-8.
    • (2015) Clin Chim Acta , vol.450 , pp. 31-38
    • Boyd, J.M.1    Krause, R.2    Waite, G.3    Hui, W.4    Yazdi, E.5    Wilmink, D.6
  • 11
    • 84904443327 scopus 로고    scopus 로고
    • Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results
    • Shin DH, Kim J, Uh Y, Lee SI, Seo DM, Kim KS, et al. Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results. Ann Lab Med 2014;34:307-12.
    • (2014) Ann Lab Med , vol.34 , pp. 307-312
    • Shin, D.H.1    Kim, J.2    Uh, Y.3    Lee, S.I.4    Seo, D.M.5    Kim, K.S.6
  • 12
    • 16244379294 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute. Second edition; EP5-A2. Wayne, PA, USA: Clinical and Laboratory Standards Institute
    • Clinical and Laboratory Standards Institute. Evaluation of Precision Performance of Quantitative measurement Methods; Approved Guideline, Second edition; EP5-A2. Wayne, PA, USA: Clinical and Laboratory Standards Institute, 2004.
    • (2004) Evaluation of Precision Performance of Quantitative Measurement Methods; Approved Guideline
  • 13
    • 84867276477 scopus 로고    scopus 로고
    • Interrater reliability: The kappa statistic
    • McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb) 2012;22:276-82.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 276-282
    • McHugh, M.L.1
  • 14
    • 84958740355 scopus 로고    scopus 로고
    • Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples
    • Nikolac N, Celap I, Filipi P, Hemar M, Kocijancic M, Miler M, et al. Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Clin Chem Lab Med 2016;54:419-25.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 419-425
    • Nikolac, N.1    Celap, I.2    Filipi, P.3    Hemar, M.4    Kocijancic, M.5    Miler, M.6
  • 17
    • 84859812541 scopus 로고    scopus 로고
    • Interference studies: Focus on blood cell lysates preparation and testing
    • Lippi G. Interference studies: focus on blood cell lysates preparation and testing. Clin Lab 2012;58:351-5.
    • (2012) Clin Lab , vol.58 , pp. 351-355
    • Lippi, G.1
  • 19
    • 74549190056 scopus 로고    scopus 로고
    • A comparative study of common techniques used to measure haemolysis in stored red cell concentrates
    • Han V, Serrano K, Devine DV. A comparative study of common techniques used to measure haemolysis in stored red cell concentrates. Vox Sang 2010;98:116-23.
    • (2010) Vox Sang , vol.98 , pp. 116-123
    • Han, V.1    Serrano, K.2    Devine, D.V.3
  • 20
    • 84908091770 scopus 로고    scopus 로고
    • Harmonization in hemolysis detection and prevention. A working group of the catalonian health institute (ICS) experience
    • Fernandez P, Llopis MA, Perich C, Alsina MJ, Alvarez V, Biosca C, et al. Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience. Clin Chem Lab Med 2014;52:1557-68.
    • (2014) Clin Chem Lab Med , vol.52 , pp. 1557-1568
    • Fernandez, P.1    Llopis, M.A.2    Perich, C.3    Alsina, M.J.4    Alvarez, V.5    Biosca, C.6
  • 22
    • 0027503865 scopus 로고
    • Conjugated, but not unconjugated, bilirubin negatively interferes in hitachi 747 assay of inorganic phosphorus
    • Alvarez F, Whalen K, Scott MG. Conjugated, but not unconjugated, bilirubin negatively interferes in Hitachi 747 assay of inorganic phosphorus. Clin Chem USA 1993;39:2345-6.
    • (1993) Clin Chem USA , vol.39 , pp. 2345-2346
    • Alvarez, F.1    Whalen, K.2    Scott, M.G.3
  • 23
    • 85029350634 scopus 로고    scopus 로고
    • I index is not an accurate indicator of icteria in conjugated hyperbilirubinemia
    • Nikolac Gabaj N, Miler M, Mihic R. I index is not an accurate indicator of icteria in conjugated hyperbilirubinemia. Clin Chim Acta 2017;473:32-4.
    • (2017) Clin Chim Acta , vol.473 , pp. 32-34
    • Nikolac-Gabaj, N.1    Miler, M.2    Mihic, R.3
  • 25
    • 85017476837 scopus 로고    scopus 로고
    • Icteric human samples: Icterus index and method of estimating an interferencefree value for 16 biochemical analyses
    • [Epub ahead of print]
    • Nicolay A, Lorec AM, Gomez G, Portugal H. Icteric human samples: icterus index and method of estimating an interferencefree value for 16 biochemical analyses. J Clin Lab Anal 2017. doi: 10.1002/jcla.22229. [Epub ahead of print].
    • (2017) J Clin Lab Anal
    • Nicolay, A.1    Lorec, A.M.2    Gomez, G.3    Portugal, H.4
  • 26
    • 84884298434 scopus 로고    scopus 로고
    • Heterogeneity of manufacturers' declarations for lipemia interference - urgent call for standardization
    • Nikolac N, Simundic AM, Miksa M, Lima-Oliveira G, Salvagno GL, Caruso B, et al. Heterogeneity of manufacturers' declarations for lipemia interference - urgent call for standardization. Clin Chim Acta 2013;426:33-40.
    • (2013) Clin Chim Acta , vol.426 , pp. 33-40
    • Nikolac, N.1    Simundic, A.M.2    Miksa, M.3    Lima-Oliveira, G.4    Salvagno, G.L.5    Caruso, B.6
  • 28
    • 84893618127 scopus 로고    scopus 로고
    • Lipemia: Causes, interference mechanisms, detection and management
    • Nikolac N. Lipemia: causes, interference mechanisms, detection and management. Biochem Med (Zagreb) 2014;24:57-67.
    • (2014) Biochem Med (Zagreb) , vol.24 , pp. 57-67
    • Nikolac, N.1
  • 29
    • 0242659853 scopus 로고    scopus 로고
    • Unreliability of triglyceride measurement to predict turbidity induced interference
    • Twomey PJ, Don-Wauchope AC, McCullough D. Unreliability of triglyceride measurement to predict turbidity induced interference. J Clin Pathol 2003;56:861-2.
    • (2003) J Clin Pathol , vol.56 , pp. 861-862
    • Twomey, P.J.1    Don-Wauchope, A.C.2    McCullough, D.3
  • 30
    • 84891139171 scopus 로고    scopus 로고
    • Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients
    • Lippi G, Giavarina D, Gelati M, Salvagno GL. Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients. Clin Chim Acta 2014;429:143-6.
    • (2014) Clin Chim Acta , vol.429 , pp. 143-146
    • Lippi, G.1    Giavarina, D.2    Gelati, M.3    Salvagno, G.L.4
  • 31
    • 84882817380 scopus 로고    scopus 로고
    • Can the roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays
    • Petrova DT, Cocisiu GA, Eberle C, Rhode KH, Brandhorst G, Walson PD, et al. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays. Clin Biochem 2013;46:1298-301.
    • (2013) Clin Biochem , vol.46 , pp. 1298-1301
    • Petrova, D.T.1    Cocisiu, G.A.2    Eberle, C.3    Rhode, K.H.4    Brandhorst, G.5    Walson, P.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.